Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
User Manual (Instructions for Use and Technical Information) ACURABLE LIMITED // CUSTOMER CONFIDENTIAL AcuPebble TM SA100/Ox100 User Manual AcuPebble Ox100 Release date: 2023-08-31 Issue: 1.1 Page 2 Copyright Acurable ©2017 All Rights Reserved Printed copies of this document are not controlled Acurable Limited Customer Confidential 1. About AcuPebble SA100/Ox100 1.1 Intended Use / Indications for Use AcuPebble SA100 is indicated to sense, record, and interpret a patientâs physiological signals (including respiratory pattern) during sleep for the purpose of prescreening patients for obstructive sleep apnea (OSA) syndrome. The device is designed for use in home-screening of adults with suspected possible sleep breathing disorders (although it can also be used in clinic). Results are used to assist the healthcare professionals in the patient's evaluation. The system is not intended as a substitute for full polysomnography when additional parameters such as sleep stages, limb movements, or EEG activity are required. AcuPebble Ox100 is a wearable device intended for use in the recording, analysis, displaying, exporting, and storage of biophysical parameters to aid in the evaluation of adult patients with, or with suspected, obstructive sleep apnea (OSA).The device is primarily intended for home setting use (although it can also be used in healthcare settings) under the direction of a Healthcare Professional (HCP). Figure 1: AcuPebble sensor (left and middle) and finger sensor (right - Ox100 only) Figure 2: Image illustrating positioning of AcuPebble sensor User Manual AcuPebble Ox100 Release date: 2023-08-31 Issue: 1.1 Page 3 Copyright Acurable ©2017 All Rights Reserved Printed copies of this document are not controlled Acurable Limited Customer Confidential 1.2 Description of the Device The AcuPebble SA100 system consists of a single miniature electronic wireless multi-use wearable device, to be worn during sleep on the neck. The AcuPebble Ox100 system is composed of two devices, one to be worn during sleep on the neck, and another one on the finger. The neck sensor attaches to the body with a single use double coated medical tape. The finger sensor can be slid on. Both sensors are used to extract information during sleep about a variety of physiological processes/channels which are relevant for the diagnosis of obstructive sleep apnoea (OSA). In both cases, the sensors transmit signals to a mobile base station (i.e. mobile phone or tablet), although in the case of the neck worn sensor, transmission occurs continuously, whereas in the finger sensor transmission only occurs after the user takes it off at the end of the study. Transmission in both cases is carried out using a commercial Bluetooth Low Energy (BLE. 2.402- 2.480 GHz frequency band, GFSK modulation and less than 4dBm radiated power) integrated circuit. They both operate with small Li-polymer batteries. In continuous operation, the system can function for over 23 hours (although note that for the intended purpose less than half of this is needed). The devices can be recharged using a standard micro-USB connector. The signals transmitted to the mobile phone can be uploaded to the Cloud, once the user stops the signal acquisition within the app, and there they are fully processed by algorithms that, amongst others, automatically determine diagnostic indexes. The outputs from both sensing devices are displayed in a Web app platform that can be accessed by physicians to aid the diagnosis. The ring sensor is used to measure peripheral oxygen saturation (SpO2). The principle of operation is as follows: two light emitting diodes with different wavelength shine light through the finger. Two photodiodes detect the transmitted light and convert it into an electrical signal. Characteristics of the received infrared and red electrical signals are computed with electronic circuits. Using those measured characteristics, a scientifically well established algorithm based on what is known as the Beer Lambert law is used to calculate the SpO2 value. Illustrative images of the wearable sensors are shown in Figures 1 and 2. User Manual AcuPebble Ox100 Release date: 2023-08-31 Issue: 1.1 Page 4 Copyright Acurable ©2017 All Rights Reserved Printed copies of this document are not controlled Acurable Limited Customer Confidential 2. How to use AcuPebble SA100/Ox100 2.1 Using the AcuPebble mobile application 2.1.1 Set up the mobile application Switch on the mobile receiver device (eg: mobile phone or tablet). Connect the mobile device to a wi-fi or mobile network to access the Internet. The AcuPebble SA100/Ox100 system works together with a mobile application. It is worth noting that most of the instructions contained in this manual do not need to be read if the instructions in the mobile application are followed. Open Google Play (for Android devices) or the App Store (for iOS devices) and search for âAcuPebble SAâ. Alternatively you can open the mobile device web browser and enter the following URL in the navigation bar, then press âEnterâ: https://acurable.com/products/sleep-apnoea/download Press the âDownloadâ button and download the app to the mobile device. After installing the application, a new icon with the text âAcuPebble SAâ will appear on your mobile device main menu. Press it to open the application. The mobile device and application are now ready to conduct sleep studies. The app will not allow the user to proceed unless the sensor is considered to be ready to complete a full night test, and it will guide the user on actions to be taken if this is not the case. 2.1.2 Conduct a sleep study You can conduct a sleep study using their own mobile phone/tablet, or using a mobile receiver already setup. If the sleep study is conducted using a mobile phone or tablet already setup, you can undertake the sleep study directly. If the sleep study is conducted using your own mobile phone or tablet, you need to activate the sleep study using a code before bâŠ
Text truncated - open the document above for the full version.
Acurable Ltd Finsgate, 5-7 Cranwood Street London, EC1V 9E Date: 22/May/2023 DEKRA Testing and Certification, S.A.U. Parque TecnolĂłgico de AndalucĂa C/ Severo Ochoa 2 & 6 29590 Campanillas MĂĄlaga, España Certifications concerning âcoveredâ equipment. Section 2.911(d)(5)(i)- (ii) FCC ID: 2A258-AP100D05 We, Acurable Limited, Finsgate, 5-7 Cranwood Street, London EC1V 9EE, United Kingdom; certify that: - the equipment for which authorization is sought is not âcoveredâ equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. - as of the date of the filing of the application, the applicant is identified on the Covered List as an entity producing âcoveredâ equipment. Sincerely, __________________________ By: Anas Imtiaz Title: Head of Engineering Company: Acurable Limited Telephone: (+44) 0208 1917590 e-mail: [email protected]
Acurable Ltd Finsgate, 5-7 Cranwood Street London, EC1V 9E Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 07- 10- 2023 (July 10 th 2023) Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: 2A258-AP100D05 Acurable Limited (âthe applicantâ) certifies that, as of the date of the filing of the application, TianHeng Consulting, LLC is our designated U.S. agent for service of process for the above referenced FCC ID. Acurable Limited accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission- related proceeding involving the equipment. TianHeng Consulting, LLC accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Sincerely, Designated U.S. Agent Information: Name: TianHeng Consulting, LLC FRN: 0033401258 Contact Person: Hualing Dong Address: 392 Andover Street, Wilmington, MA 01887, United States Tel.: +1 617-997- 4010 Email: [email protected] U.S. Agent Signature: Applicant: Company Name: Acurable Limited Grantee Code: 2A258 Applicant FRN: 0031355084 Contact Name: Anas Imtiaz Address: Finsgate, 5-7 Cranwood Street, London EC1V 9EE, United Kingdom Tel.: (+44) 0208 1917590 Email: [email protected] Applicant Signature: Hualing Dong, President
AcurableLtd Finsgate,5-7CranwoodStreet London,EC1V9E Date:22/May/2023 DEKRATestingandCertification,S.A.U. ParqueTecnolĂłgicodeAndalucĂa C/SeveroOchoa2&6 29590Campanillas MĂĄlaga,España Ref:AgentletterforFCCID:2A258-AP100D05 We, AcurableLimited Finsgate,5-7CranwoodStreet,LondonEC1V9EE,UnitedKingdom, herebyauthorize DEKRATestingandCertification,S.A.U, SeveroOchoa,2&6,29590Malaga,Spain Mr./Ms.MartaArrabalViciana, e-mail:[email protected], Phone:+34952619899 toactasouragentinthepreparationofthisapplicationforequipmentcertification,includingthesigningofalldocuments relatingtothesematters. Thepresentauthorizationconsidersthedevelopmentofdocumentsonbehalfoftheclient,writtenunderhisown letterheadandrelatedtothenecessaryinformationtobeprovidedonhisbehalftocompletethecertificationprocess. WealsoherebycertifythatneitherwenoranypartytothisapplicationaresubjecttoadenialofU.S.Federalbenefits, whichincludeFCCbenefits,pursuanttoSection5301oftheAnti-DrugAbuseActof1988,U.S.C.862becauseof convictionforpossessionordistributionofcontrolledsubstance. Forinstanceswhereourauthorizedagentsignstheapplicationforcertificationonourbehalf,Iacknowledgethatall responsibilityforcomplyingwiththetermsandconditionsforCertification,asspecifiedbyDEKRATestingand Certification,S.A.U.,stillresideswithus. Thisagreementexpiresoneyearfromthecurrentdate. Sincerely, __________________________ By:AnasImtiaz Title:HeadofEngineering Company:AcurableLimited Telephone:(+44)02081917590 e-mail:[email protected]
Acurable Ltd Finsgate, 5-7 Cranwood Street London, EC1V 9E Date: 22/May/2023 DEKRA Testing and Certification, S.A.U. Parque TecnolĂłgico de AndalucĂa C/ Severo Ochoa 2 & 6 29590 Campanillas MĂĄlaga, España Ref: Confidentiality request for FCC ID: 2A258-AP100D05 To whom it may concern: Pursuant to §0.457(d)(1)(ii) and §0.459 of the Commissionâs Rules (47 C.F.R.) and §552 (b)(4) of the Freedom of Information Act, Acurable Limited hereby requests that a part of the subject FCC application be held confidential to avoid release of sensitive information of the product to the public. For the product stated above, we request that the following information be withheld from public disclose: Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term External Photos Short Term Internal Photos Short Term Permanent Operation Description Short Term Permanent Parts List & Placement/BOM Short Term Permanent Tune-Up Procedure Short Term Permanent Schematics Short Term Test Setup Photos Short Term Userâs Manual Short Term Permanent SDR software and security information Permanent Confidentiality: The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to us and provide unjustified benefits to our competitors. Short-Term Confidentiality: We hereby request short-term confidentiality for the product stated above to avoid premature release of sensitive information prior to marketing or release of the product to the public. Release date of short term confidentiality is: 45 days from grant date marked 90 days from grant date marked 135 days from grant date marked 180 days from grant date marked Specific date: We are also aware that we are responsible to notify DEKRA in the event information regarding the product or the product is made available to the public. DEKRA will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Sincerely, __________________________ By: Anas Imtiaz Title: Head of Engineering Company: Acurable Limited Telephone: (+44) 0208 1917590 e-mail: [email protected]
Acurable Labelling(US) AcuPebbleOx100sensorandaccompanyingsoftware XIII-1of82 AcuPebbleOx100sensorandaccompanyingsoftware Labeling(US) Notice AcurableLimitedcannotacceptanyfinancialorotherresponsibilitiesthatmaybetheresultofyouruseof information,softwareordevicesprovidedbyAcurable,includingdirect,indirect,specialorconsequential damagesorlossofprofits.Therearenowarrantiesextendedorgrantedbythisdocumentorsoftware material.Youshouldbeverycarefulthattheuseofinformation,softwareanddevicesprovidedby Acurablecomplieswiththelaws,rules,andregulationsofthejurisdictionswithrespecttowhichitisused. Nopartofthisdocumentmaybereproducedortransmittedinanyformorbyanymeans,electronicor mechanical,foranypurpose,withouttheexpresswrittenpermissionofAcurable.Theinformation containedhereinissubjecttochangewithoutnotice.Revisionsmaybeissuedadvisingofsuchchanges and/oradditions. Copyright©2018AcurableLimited Trademarks AcuPebbleisatrademarkofAcurableLimited.Alltradenamesreferencedaretheservicemark, trademark,orregisteredtrademarkoftherespectiveorganisation. RegisteredCompany AcurableLimitedisregisteredinEnglandandWalesNo.10310661 Registeredaddress:Finsgate,5-7CranwoodStreet,LondonEC1V9EE AcurableLtd CompanyConfidential CopyrightAcurable©2022 AllRightsReserved Printedcopiesarenotcontrolled Issue:1.2 ReleaseDate:01-Aug-2023 XIII-2of82 AcuPebbleOx100sensorandaccompanyingsoftware Labeling(US) DocumentControl DocumentInformation DocumentName:Labelling(US) Issue:1.2 PublishedDate:01-Aug-2023 DocumentVersionHistory IssueDateAuthorRoleDescription 0.115-Feb-2022ElizabethDyerOperations Manager Firstversiondraft 1.022-Jul-2022EmilioSanz-PereirasCEOReviewandupdate 1.119-Jul-2023ElizabethGilmoreOperations Manager UpdateFCCIDonpackaging labelsandfinalversionof oximeterlabel 1.201-Aug-2023ElizabethGilmoreOperations Manager Addregulatoryinformationfor Canada DocumentApproval IssueNameRoleApproval Outcome SignatureDate 1.0Emilio Sanz-Pereiras ChiefExecutive Officer Approved22-Jul-2022 1.1Emilio Sanz-Pereiras ChiefExecutive Officer Approved19-Jul-2023 1.2Emilio Sanz-Pereiras ChiefExecutive Officer Approved01-Aug-2023 AcurableLtd CompanyConfidential CopyrightAcurable©2022 AllRightsReserved Printedcopiesarenotcontrolled Issue:1.2 ReleaseDate:01-Aug-2023 XIII-3of82 AcuPebbleOx100sensorandaccompanyingsoftware Labeling(US) TableofContents 1.INTRODUCTION5 2.APPLICABLESTANDARDS5 3.PRODUCTLABELS6 3.1Labelsensorsenclosure8 3.2Labeladhesives10 3.3Labelpackaging(external)10 3.4Labelpackaging(internal)11 3.5Labeltransport12 3.6Labelmobileapp14 3.7Labelwebapp16 AcurableLtd CompanyConfidential CopyrightAcurable©2022 AllRightsReserved Printedcopiesarenotcontrolled Issue:1.2 ReleaseDate:01-Aug-2023 XIII-4of82 AcuPebbleOx100sensorandaccompanyingsoftware Labeling(US) 1.INTRODUCTION TheAcuPebbleOx100medicaldeviceisaccompaniedbylabelingthatprovidestheinformation neededtousethedevicesafelyandproperly,takingaccountofthetrainingandknowledgeof thepotentialusers,andidentifiesthedeviceandthemanufacturer. Thislabelingiscompliantwith: âTheEssentialRequirementsinAnnexIsection13oftheEuropeanMedicalDevice Directive(MDD)93/42/EECwhichprovidesthespecificrequirementsforthecontentof theproductlabeling,andtheEUregulation207/2012fortheonlineversionofthe InstructionsforUseforhealthcareprofessionals. âTheFDArequirementsforlabelingofmedicaldevices,including21CFRpart801,and theFCCrequirementsforRFdevices. 2.APPLICABLESTANDARDS AcuPebbleOx100labelshavebeendesignedincompliancewiththefollowingstandards: âBSENISO15233-1:2016-MedicaldevicesâSymbolstobeusedwithmedicaldevice labels,labelingandinformationtobesupplied. âBSEN60601-1:2006+A12:2014-Medicalelectricalequipment.Generalrequirements forbasicsafetyandessentialperformance. âBSISO7000:2004-Graphicalsymbolsforuseonequipment âBSENISO7010:2012+A7:2017-GraphicalsymbolsâSafetycolorsandsafetysigns âRegisteredsafetysigns. âIEC60878:2015-Graphicalsymbolsforelectricalequipmentinmedicalpractice âBSEN80416-3:2002+A1:2011-Basicprinciplesforgraphicalsymbolsforuseon equipment.Guidelinesfortheapplicationofgraphicalsymbols. âEN50419:2006-Markingofelectricalandelectronicequipmentinaccordancewith article11(2)ofDirective2002/96/EC(WEEE). AcurableLtd CompanyConfidential CopyrightAcurable©2022 AllRightsReserved Printedcopiesarenotcontrolled Issue:1.2 ReleaseDate:01-Aug-2023 XIII-5of82 AcuPebbleOx100sensorandaccompanyingsoftware Labeling(US) 3.PRODUCTLABELS AcuPebbleOx100labelingiscomposedoftheInstructionsforuse(aka:UserManual)and severallabelsdisplayedoneachoneoftheproductcomponentsvisiblebytheuser. TitleComponentKeyVersion Labelnecksensor enclosure AcuPebbleOx100necksensorAP-1441.0 Labelfingersensor enclosure AcuPebbleOx100fingersensorOX-11.1 LabeladhesivesAcuPebbleSA100adhesivesAP-1631.0 Labelpackaging (external) AcuPebbleOx100packagingAP-2571.2 Labelpackaging (internal) AcuPebbleOx100packagingAP-2561.1 LabeltransportShippingouterpackaging(Ox100)AP-1491.1 LabelmobileappAcuPebbleOx100mobileapplicationSAM-2911.1 LabelwebappAcuPebbleOx100webapplicationSAW-4141.0 AcurableLtd CompanyConfidential CopyrightAcurable©2022 AllRightsReserved Printedcopiesarenotcontrolled Issue:1.2 ReleaseDate:01-Aug-2023 XIII-6of82 AcuPebbleOx100sensorandaccompanyingsoftware Labeling(US) 3.1Labelsensorsenclosure AcuPebbleOx100iscomposedoftwofullyindependentsensors,onethatistobeplacedonthe neckandanotheroneonthefinger.Thesensorontheneckisexactlythesameasthe previouslycleareddeviceâAcuPebbleSA100â(K210480),hencethelabelonthesensoris identicaltothisoneandhasbeenpreviouslyclearedbytheFDA.Forcompleteness,however,it isalsopresentedintheparagraphbelow. Necksensorlabel(identicaltopreviouslyclearedK210480) Labeltobedisplayed(ie:printed)atthebottomoftheAcuPebbleOx100sensorenclosure. âNotethatthesensorlabeldoesnothavethefullUDI(GTIN)becausethereisnot enoughspaceduetotheverysmallsizeofthedevice(29mmindiameter).Notethe labelcanonlybeprintedonthesensorenclosurebase,becausetheothersurfaces(ie: sidesandtop)arenotflatandcannotbeprintedon. âThefullUIDandFCCIDaredisplayedonthesensorpackagâŠ
Text truncated - open the document above for the full version.
DEKRA Testing and Certification, S.A.U. Parque TecnolĂłgico de AndalucĂa, c/ Severo Ochoa nÂș 2 · 29590 Campanillas · MĂĄlaga · España C.I.F. A29 507 456 Report No: (NIE) 75213RAN.001 2023-05-18 Test report No: NIE: 75213RAN.001 Assessment report RF EXPOSURE REPORT ACCORDING TO FCC 47 CFR Part 2.1093 FCC 47 CFR Part 1.1307 (*) Identification of item under evaluation Wearable biosignals monitor (*) Trademark ACUPEBBLE (*) Model and /or type reference ACUPEBBLE 100 (*) Other identification of the product HW version: D05 SW Version: 2.0.0 (*) Features Bluetooth LE (*) Manufacturer Acurable Limited Finsgate, 5-7 Cranwood Street, London EC1V 9EE, United Kingdom Test method requested, standard FCC 47 CFR Part 2.1093. Radiofrequency radiation exposure evaluation: portable devices. FCC 47 CFR Part 1.1307: Actions that may have a significant environmental effect, for which Environmental Assessments (EAs) must be prepared. Summary IN COMPLIANCE Approved by (name / position & signature) Miguel Lacave Antennas Lab Manager Date of issue 2023-05-18 Report template No FAN24_02 (*) âData provided by the clientâ DEKRA Testing and Certification, S.A.U. Parque TecnolĂłgico de AndalucĂa, c/ Severo Ochoa nÂș 2 · 29590 Campanillas · MĂĄlaga · España C.I.F. A29 507 456 Report No: (NIE) 75213RAN.001 Page 2 of 8 2023-05-18 Index Competences and guarantees .................................................................................................... 3 General conditions ...................................................................................................................... 3 Data provided by the client .......................................................................................................... 3 Identification of the client............................................................................................................. 3 Document history ........................................................................................................................ 3 Appendix A: FCC RF Exposure assessment result ..................................................................... 4 General description of the device under evaluation ................................................................ 5 Evaluation Results .................................................................................................................. 5 Appendix B: FCC RF Exposure information ................................................................................ 6 RF Exposure determination of exemption ............................................................................... 7 DEKRA Testing and Certification, S.A.U. Parque TecnolĂłgico de AndalucĂa, c/ Severo Ochoa nÂș 2 · 29590 Campanillas · MĂĄlaga · España C.I.F. A29 507 456 Report No: (NIE) 75213RAN.001 Page 3 of 8 2023-05-18 Competences and guarantees In order to assure the traceability to other national and international laboratories, DEKRA Testing and Certification, S.A.U. has a calibration and maintenance program for its measurement equipment. DEKRA Testing and Certification, S.A.U. guarantees the reliability of the data presented in this report, which is the result of the measurements and the tests performed to the item under test on the date and under the conditions stated on the report and, it is based on the knowledge and technical facilities available at DEKRA Testing and Certification, S.A.U. at the time of performance of the test. DEKRA Testing and Certification, S.A.U. is liable to the client for the maintenance of the confidentiality of all information related to the item under test and the results of the test. The results presented in this Assessment Report apply only to the particular item under test established in this document. IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means, except in full, without the previous written permission of DEKRA Testing and Certification, S.A.U. General conditions 1. This report is only referred to the item that has undergone the assessment. 2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies or competent Authorities. 3. This document is only valid if complete; no partial reproduction can be made without previous written permission of DEKRA Testing and Certification, S.A.U. 4. This test report cannot be used partially or in full for publicity and/or promotional purposes without previous written permission of DEKRA Testing and Certification, S.A.U. and the Accreditation Bodies Data provided by the client The following data has been provided by the client: 1. Information relating to the description of the sample ("Identification of the item under evaluation", "Trademark", "Model and/or type reference", âOther identification of the productâ, âFeaturesâ, âManufacturerâ and âGeneral description of the deviceâ). 2. Maximum antenna gain and use distance information. DEKRA Testing and Certification, S.A.U. declines any responsibility with respect to the information provided by the client and that may affect the validity of results. Identification of the client Company name: Acurable Limited Postal address: Finsgate, 5-7 Cranwood Street, London EC1V 9EE, United Kingdom Contact person: Emilio Sanz Pereiras Telephone / e-mail: +447860657089 / [email protected] Document history Report number Date Description 75213RAN.001 2023-05-18 First release DEKRA Testing and Certification, S.A.U. Parque TecnolĂłgico de AndalucĂa, c/ Severo Ochoa nÂș 2 · 29590 Campanillas · MĂĄlaga · España C.I.F. A29 507 456 Report No: (NIE) 75213RAN.001 Page 4 of 8 2023-05-18 Appendix A: FCC RF Exposure assessment result DEKRA Testing and Certification, S.A.U. Parque TecnolĂłgico de AndalucĂa, c/ Severo Ochoa nÂș 2 · 29590 Campanillas · MĂĄlaga · España C.I.F. A29 507 456 Report No: (NIE) 75213RAN.001 Page 5 of 8 2023-05-18 General description of the device under evaluation The device under evaluation consists of a miniatâŠ
Text truncated - open the document above for the full version.
2450 MHz AntennaP/N 2450AT18B100 Detail Specification: 03/08/2016 Page 1 of 4 Mechanical Dimensions Inmm L±± W±± T a±± Mount these devices with brown mark facing up. Units: mm Line width should be designed to provide 50 ⊠impedance matching characteristics. a) Without Matching Circuits b) With Matching Circuits Johanson Technology, Inc. reserves the right to make design changes without notice. All sales are subject to Johanson Technology, Inc. terms and conditions. Ver.2.1 www.johansontechnology.com 4001 Calle Tecate âą Camarillo, CA 93012 âą TEL 805.389.1166 FAX 805.389.1821 2016 Johanson Technology, Inc. All Rights Reserved NC Termination style 100% Tin 0.020 1.30 0.30 Tin / LeadPlease consult Factory 1.600.200.008 Feeding Point 2 Suffix = None Mounting Considerations Terminal Configuration No. 1 Function 0.012 0.051+.004/-.008+0.1/-0.2 Part Number Explanation BulkSuffix = SEg. 2450AT18B100S T & RSuffix = EEg. 2450AT18B100E Packaging Style P/N Suffix Eg. 2450AT18B100(E or S) General Specifications Input Power Impedance Operating Temperature Reel Quanity Peak Gain Average Gain-0.5 dBi typ. (XZ-V) 9.5 dB min. Part Number Frequency Range 2W max. 50 ⊠-45°C to 125°C 3,000 Return Loss "High Frequency Ceramic Solutions" 0.50 0.1260.0083.200.20 0.063 2450AT18B100 2400 - 2500 Mhz 0.5 dBi typ. (XZ-V) 1 2 L W a T ) Matching Component JTI P/Ns: L-14C2N7JV4 L-14C2N2JV4 * 2.6 4.2 1.6 1.9 0.4 2.7nH 1.2pF 3.3nH JTI P/N for Matching Circuit: Cap (1.2pF): 500R07S1R2BV4T Inductor (2.7nH): L-07C2N7SV6T Inductor (3.3nH): L-07C3N3SV6T 2450 MHz AntennaP/N 2450AT18B100 Detail Specification: 03/08/2016 Page 2 of 4 Test Board: Return Loss a) Without Matching Circuitb) With Matching Circuit Johanson Technology, Inc. reserves the right to make design changes without notice. All sales are subject to Johanson Technology, Inc. terms and conditions. Ver.2.1 www.johansontechnology.com 4001 Calle Tecate âą Camarillo, CA 93012 âą TEL 805.389.1166 FAX 805.389.1821 2016 Johanson Technology, Inc. All Rights Reserved "High Frequency Ceramic Solutions" Typical Electrical Characteristics (T=25 o C) ) ) ) ) ) ) ) ) ) Ground 13.5mm 6.5mm 39.5mm 6.5mm Matching Circuit No Ground 50ï Feed Line Antenna 19mm 4mm 2450 MHz AntennaP/N 2450AT18B100 Detail Specification: 03/08/2016 Page 3 of 4 Johanson Technology, Inc. reserves the right to make design changes without notice. All sales are subject to Johanson Technology, Inc. terms and conditions. Ver.2.1 www.johansontechnology.com 4001 Calle Tecate âą Camarillo, CA 93012 âą TEL 805.389.1166 FAX 805.389.1821 2016 Johanson Technology, Inc. All Rights Reserved "High Frequency Ceramic Solutions" Typical Radiation Patterns at 2.45GHz (+25C) ) ) ) ) ) ) ) ) ) 2450 MHz AntennaP/N 2450AT18B100 Detail Specification: 03/08/2016 Page 4 of 4 Would you like Johanson Technology's RF team to help you design and tune our antenna on your board? Click on the link below: Johanson Technology, Inc. reserves the right to make design changes without notice. All sales are subject to Johanson Technology, Inc. terms and conditions. Ver.2.1 www.johansontechnology.com 4001 Calle Tecate âą Camarillo, CA 93012 âą TEL 805.389.1166 FAX 805.389.1821 2016 Johanson Technology, Inc. All Rights Reserved www.johansontechnology.com/recommended-storage-conditions www.johansontechnology.com/tape-reel-packaging Soldering Information www.johansontechnology.com/typical-soldering-profile RoHS Compliance www.johansontechnology.com/rohs-compliance MSL Info "High Frequency Ceramic Solutions" Antenna layout review, tuning, and characterization services http://www.johansontechnology.com/ipc-antenna-services Packaging information www.johansontechnology.com/msl-rating.html Recommneded Storage Condition and Max Shelf Life ) ) ) ) ) ) ) ) )
DEKRA Testing and Certification, S.A.U. Parque TecnolĂłgico de AndalucĂa, c/ Severo Ochoa nÂș 2 · 29590 Campanillas · MĂĄlaga · España C.I.F. A29507456 Report No:OFFERRRF.001 2023-05-11 ISED CABid: ES1909 Lab. Company Number: 4621A Test Report No: 75213RRF.001 Test Report USA FCC Part 15.247, 15.209 CANADA RSS-247, RSS-Gen (*) Identification of item tested Wearable biosignals monitor (*) Trademark ACUPEBBLE (*) Model and /or type reference ACUPEBBLE 100 Other identification of the product -- (*) Features FCC ID: 2A258-AP100D05 IC: 30461-AP100D05 Features: Bluetooth LE HW version: D05 SW version: 2.0.0 Applicant Acurable Limited Finsgate, 5-7 Cranwood Street, London EC1V 9EE, United Kingdom Test method requested, standard USA FCC Part 15.247 (10-1-21 Edition): Operation within the bands 902 - 928 MHz, 2400 -2483.5 MHz, and 5725 - 5850 MHz. USA FCC Part 15.209 (10-1-21 Edition): Radiated emission limits; general requirements. CANADA RSS-247 Issue 2 (February 2017). CANADA RSS-Gen Issue 5 amendment 1 (March 2019). Guidance for Performing Compliance Measurements on Digital Transmission System, Frequency Hopping Spread Spectrum System, and Hybrid Systems Devices Operating Under Section 15.247 of the FCC Rules. 558074 D01 Meas Guidance v05r02 dated April 2, 2019. ANSI C63.10-2013: American National Standard for Testing Unlicensed Wireless Devices. Summary IN COMPLIANCE Approved by (name / position & signature) JosĂ© Manuel GĂłmez GalvĂĄn EMC Consumer & RF Lab. Manager Date of issue 2023-05-11 Report template No FDT08_24 (*) âData provided by the clientâ DEKRA Testing and Certification, S.A.U. Parque TecnolĂłgico de AndalucĂa, c/ Severo Ochoa nÂș 2 · 29590 Campanillas · MĂĄlaga · España C.I.F. A29507456 Report No: 75213RRF.001 Page 2 of 54 2023-05-11 Index INDEX ........................................................................................................................................................................... 2 ACRONYMS ................................................................................................................................................................. 3 COMPETENCES AND GUARANTEES ........................................................................................................âŠ
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 502.00 ”W |