Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 12, 2021
Application Purpose
Original Equipment
Date of Application
Jul 12, 2021
Equipment Note
Wireless Router
Frequency Range
2412.00000000 - 2462.00000000
Company
Shenzhen Urant Technology Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

APPENDIXB ShenzhenUrantTechnologyCo.,Ltd [2021-06-25] FederalCommunicationsCommission 44512 th StreetSW Washington,DC20554 Subject:LimitedAgencyAgreement ShenzhenUrantTechnologyCo.,Ltd FCCID:2A2F41200M ToWhomItMayConcern: We,ShenzhenUrantTechnologyCo.,Ltd,herebyauthorizedIntertekTestingServicestoactasourAgentforthepurposeofpreparing applicationforFCCIDnumber2A2F41200MunderallapplicablepartsoftheFCCrulesandregulations. Theeffectivedateofthislimitedagencyagreementis2021-06-25.TheLimitedAgencyAgreementexpireson2023-06-25,unlesssooner terminatedorextendedbywrittennoticetoIntertekTestingServicesandtheFederalCommunicationsCommission. ThisistoadvisethatweareinfullcompliancewiththeAnti-DrugAbuseAct.Theapplicantisnotsubjecttoadenialoffederalbenefits pursuanttoSection5301oftheAnti-DrugActof1988,21U.S.C.862,andnopartytotheapplicationissubjecttoadenialoffederal benefitspursuanttothatsection. Ifyouhaveanyquestionsorcomments,pleasedonothesitatetocontactme. Sincerely, [Signature] [TypeName]HuangXiaohong [TypeTitle]Manager

Cover Letter(s)

APPENDIXE ShenzhenUrantTechnologyCo.,Ltd Attention:Certificationreviewer RE:RequestforConfidentiality FCCID:2A2F41200M ToWhomItMayConcern: PermanentConfidentiality[Completethissectionifpermanentconfidentialityisrequested] RequesttowithholdpermanentlyfrompublicreviewcertainportionsoftheapplicationforequipmentcertificationforthereferencedFCCidentifiers.This requestforconfidentialityismadepursuantto47CFR0.457(d)and0.459oftheFCCRules.Inparticular,thefollowingsectionsoftheapplicationaretobe keptpermanentlyconfidential: [Selectoneormoreofitemsbelow,asappropriate] Schematics BlockDiagrams OperationalDescription Tune-upProcedure PartsList InternalPhotos(seenote) UsersManual(seenote) Note1:InternalPhotosmaybeheldconfidential1)ifthecircuitboardorinternalcomponentsarenotaccessible tousers.Forexample,itisacceptableifthecircuitboardisenclosedinepoxy.2)Also,itisacceptableif thedeviceisnotaccessibletothepublic,forexample,adevicemountedonthetopofalargetower(or inafencedenclosure)suchthatitisonlyserviceablebyprofessionaldesignatedtechniciansundera Non-DisclosureAgreement(NDA).AllsalesforthesedevicesmustbeunderaNDArestrictingthe disclosureoftheproprietyinformation,includinginternalphotos. UsersManualmaybeheldconfidentialonlywhenthemanualcontainsproprietarytechnicalinformation intendedforprofessionaltechniciansobligatedunderaNDA.Allsalesanddistributionoftheuser’s manualmustbeunderaNDAthatrestrictsthedisclosureoftheinformation. Intheapplicationcoverletterrequestingpermanentconfidentialitythefollowingadditionaldescription andtheNDAexhibitisrequired: 1.Describeindetailhowinternalphotosand/orusersmanualinformationarecontrolledtopreventthem frombecomingpublicordisclosedtounauthorizedpersons. 2.Describehowpublicaccessisrestrictedforproductsserviceablebyprofessionaldesignated technicians. 3.Astatementthatallsalesofthenon-consumerdevicewillbeunderaNDAtoincludethirdpartysales andthatthefinaluserofthedeviceissubjecttotheNDA. 4.ProvideanexampleoftheNDAbetweenthegranteeandapurchaser.Therequestforconfidentiality must Note2:Forscanningreceiver,theschematics,blockdiagrams,operationaldescription,tune-upprocedure,partslistandinternalphotosarealwaysheldpermanently confidential. Short-termConfidentiality[Completethissectionifshort-termconfidentialityisrequested] Requesttowithholdfrompublicreviewforaperiodof[pleaseenter1to180]daysfromthedateoftheGrantofEquipmentAuthorizationandpriorto marketing,certainportionsoftheapplicationforequipmentcertificationforthereferencedFCCidentifiers.Thisrequestforconfidentialityismadepursuant to47CFR0.457(d)and0.459oftheFCCRules.Inparticular,thefollowingsectionsoftheapplicationaretobekeptshort-termconfidentialforaperiod abovefromthedateofthegrant [Selectoneormoreofitemsbelowthatarenotselectedinthelistabove,asappropriate] Schematics Blockdiagrams OperationalDescription Tune-upProcedure PartsList TestSetupPhotos ExternalPhotos InternalPhotos UsersManual Rationaleforrequestforconfidentiality: Wehaveinvestedconsiderabletimeandmaterialsinresearchanddevelopmenttoproducethereferencedproduct. Permanentconfidentiality:Disclosureofthepermanentlyconfidentialportionsofthisapplicationtocompetitorswouldnotonlygivethemsignificant competitiveadvantagesindevelopingsimilarproducts,butwouldalsodisclosesuccessfulimplementationofunpublished,leadingedgetechnology developedbyus. Short-termconfidentiality:Disclosureoftheshort-termconfidentialportionsofthisapplicationduringtheperiodofimportationand/ordistribution wouldrevealkeyaspectsofproprietarytechnologytocompetitorsanddiminishthevalueofourinvestmentinresearchanddevelopment. Ifyouhavequestionsorneedfurtherinformation,pleasecontacttheundersigned. Sincerely, _________________ HuangXiaohong Manager 2021-6-25

Cover Letter(s)

There are two types of this product: FCC and CE. The two products are the same except for the power module and plug. These two products were certified at the same time, resulting in confusion and error in using product photos when submitting FCC certificate. We have corrected the internal and external photos. Please see the comparison figure below for specific corrections. External Photos: Original Corrected Internal Photos: Original Corrected Nov 10, 2021

ID Label/Location Info

50mm*39mm

Internal Photos

5G Antenna 2.4G Antenna

RF Exposure Info

FCC ID: HDC17600021F1 INTERTEK TESTING SERVICES RF Exposure The Equipment Under Test (EUT) is a Wireless Router has WiFi function, and WiFi operating at 2412-2462MHz for 802.11b/g/n-HT20, 11 channels with 5MHz channel spacing; 2422-2452MHz for 802.11n-HT40, 9 channels with 5MHz channel spacing; 5180 MHz - 5240 MHz & 5745MHz – 5825MHz for 802.11a/n/ac-HT20 with 9 channels; 5190 MHz ~ 5230 MHz & 5755MHz – 5795MHz for 802.11n/ac-HT40 with 4 channels and 5210 MHz & 5775MHz for 802.11ac-HT80 with 2 channel. The EUT was powered by AC100~240V, 50/60Hz. 2.4G and 5G can’t operation simultaneous. Details please see user manual. 2.4GHz WiFi: Antenna Type: Integral Antenna. Antenna Gain (Chain 1): 3.0dBi Antenna Gain (Chain 2): 3.0dBi Modulation Type: BPSK, QPSK, 16QAM, 64QAM, CCK, DQPSK, DBPSK and DSSS. The nominal conducted output power specified: 14dBm (Tolerance: ±4dB). 5GHz WiFi: Antenna Gain (Chain 1): 2.0dBi Antenna Gain (Chain 2): 2.0dBi Modulation Type: BPSK, QPSK, 16QAM, 64QAM and OFDM. The nominal conducted output power specified: 15dBm (Tolerance: ±5dB). According to FCC Part 2.1091, this unlicensed transmitting devices is categorically excluded from routine environmental evaluation for RF exposure prior to equipment authorization or use, According to the KDB 447498 and OET 65, the simple calculation as below: For 2.4GHz Band The source-based time averaged maximum radiated power in ANT 4 mode = 14+5+3.0= 22.0dBm = 158.49mW From above data, the exposed power density at a distance (R) of 20cm from the center of radiation of the antenna for 2.4GHz band can be calculated according to OET 65 as follow: = 158.49/ 4πR^2 = 0.03 mW/cm^2 For 5GHz Band The source-based time averaged maximum radiated power in MIMO mode = 15+5+2.0= 22.0dBm = 158.49mW From above data, the exposed power density at a distance (R) of 20cm from the center of radiation of the antenna for 5GHz band can be calculated according to OET 65 as follow: = 158.49/ 4πR^2 = 0.03 mW/cm^2 The MPE limit is 1.0 mW/cm^2 for general population and uncontrolled exposure in the Bluetooth frequency range according to FCC Part 1.1310. As the measured power density at 20cm from the transmitter is lower than the MPE limit, the compliance to the MPE limit can be ensured by indicating the minimum 20cm separation between the transmitter's radiating structure and body of the user or nearby persons. FCC ID: HDC17600021F1 INTERTEK TESTING SERVICES The following RF exposure statement or similar sentence is proposed to be included in the user manual: “FCC RF Radiation Exposure Statement Caution: This Transmitter must be installed to provide a separation distance of at least 20 cm from all persons.”

Test Report

Shenzhen Urant Technology Co., Ltd TEST REPORT SCOPE OF WORK FCC TESTING– 1200M REPORT NUMBER 210204040SZN-002 ISSUE DATE [REVISED DATE] 30 June 2021 [---------------------] PAGES 36 DOCUMENT CONTROL NUMBER FCC ID 247_b © 2017 INTERTEK Intertek Report No.: 210204040SZN-002 This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Testing Services Shenzhen Ltd. Longhua Branch 101, 201, Building B, No. 308 Wuhe Avenue, Zhangkengjing Community, GuanHu Subdistrict, LongHua District, Shenzhen, P.R. China. Tel: (86 755) 8601 6288 Fax: (86 755) 8601 6751 Version: 01-November-2017 Page: 1 of 36 FCC ID 247_b TEST REPORT 101, 201, Building B, No. 308 Wuhe Avenue, Zhangkengjing Community, GuanHu Subdistrict, LongHua District, Shenzhen, P.R. China. Tel: (86 755) 8601 6288 Fax: (86 755) 8601 6751 www.intertek.com TEST REPORT Report No. : 210204040SZN-002 Product : Wireless Router Model No. : 1200M FCC ID : 2A2F41200M Applicant: Shenzhen Urant Technology Co., Ltd Room 302, Building 1, Second District, Fumin Industrial Zone, Pinghu Community, Pinghu Street, Longgang District, Shenzhen, China Test Method/ Standard: FCC Part 15 Subpart C; FCC KDB 558074 D01 v05r02 FCC KDB 662911 D01 v02r01 ANSI C63.10-2013 Conclusion: The sample as received complied with the FCC Part 15 Subpart C requirement. Test By: Intertek Testing Services Shenzhen Ltd. Longhua Branch 101, 201, Building B, No. 308 Wuhe Avenue, Zhangkengjing Community, GuanHu Subdistrict, LongHua District, Shenzhen, P.R. China. Sample Receipt Date: 04 Feb 2021 Test Conducted Date: 04 Feb 2021 to 28 June 2021 Issue Date: 30 June 2021 Prepared and Checked by: Approved by: Allen Qin Peter Kang Engineer Senior Technical Supervisor Intertek Report No.: 210204040SZN-002 Version: 01-November-2017 Page: 2 of 36 FCC ID 247_b TEST REPORT MEASUREMENT/TECHNICAL REPORT This report concerns (check one) Original Grant X Class II Change Equipment Type: DTS - Part 15 Digital Transmission Systems (Wi-Fi transmitter portion) Deferred grant requested per 47 CFR 0.457(d)(1)(ii)? Yes No X If yes, defer until : date Company Name agrees to notify the Commission by: date of the intended date of announcement of the product so that the grant can be issued on that date. Transition Rules Request per 15.37? Yes No X If no, assumed Part 15, Subpart C for intentional radiator - the new 47 CFR [10-01- 19] Edition] provision. Report prepared by: Allen Qin Intertek Testing Services Shenzhen Ltd. Longhua Branch 101, 201, Building B, No. 308 Wuhe Avenue, Zhangkengjing Community, GuanHu Subdistrict, LongHua District, Shenzhen, P.R. China. Tel: (86 755) 8614 0684 Fax: (86 755) 8601 6661 Intertek Report No.: 210204040SZN-002 Version: 01-November-2017 Page: 3 of 36 FCC ID 247_b TEST REPORT Table of Contents 1.0 Summary of Test results ............................................................................................... 4 2.0 General Description ...................................................................................................... 5 2.1 Product Description ........................................................................................................... 5 2.2 Related Submittal(s) Grants ............................................................................................... 5 2.3 Test Methodology .............................................................................................................. 5 2.4 Test Facility ........................................................................................................................ 5 3.0 System Test Configuration ............................................................................................ 6 3.1 Justification ........................................................................................................................ 6 3.2 EUT Exercising Software ..................................................................................................... 6 3.3 Special Accessories ............................................................................................................ 6 3.4 Measurement Uncertainty ................................................................................................. 7 3.5 Equipment Modification .................................................................................................... 7 3.6 Support Equipment List and Description .......................................................................... 7 4.0 Measurement Results ................................................................................................... 8 4.1 Maximum Conducted Output Power at Antenna Terminals ................................................. 8 4.2 Minimum 6 dB RF Bandwidth ............................................................................................ 9 4.3 Maximum Power Density Reading ................................................................................... 10 4.4 Out of Band Conducted Emissions ................................................................................... 11 4.5 Out of Band Radiated Emissions ............................................…

Text truncated - open the document above for the full version.

Test Report

Appendix of 210204040SZN-002 Appendix A:6dB Emission Bandwidth Test Result TestMode Antenna Channel 6db EBW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 11N4OMIMO Ant1 2422 29.040 2410.600 2439.640 >=0.5 PASS Ant2 2422 35.160 2404.420 2439.580 >=0.5 PASS Ant1 2437 34.020 2420.620 2454.640 >=0.5 PASS Ant2 2437 34.020 2419.360 2453.380 >=0.5 PASS Ant1 2452 35.220 2434.420 2469.640 >=0.5 PASS Ant2 2452 35.160 2434.420 2469.580 >=0.5 PASS 11G Ant1 2412 13.920 2404.440 2418.360 >=0.5 PASS Ant2 2412 13.890 2405.670 2419.560 >=0.5 PASS Ant1 2437 12.900 2430.460 2443.360 >=0.5 PASS Ant2 2437 13.920 2429.410 2443.330 >=0.5 PASS Ant1 2462 13.920 2455.640 2469.560 >=0.5 PASS Ant2 2462 14.430 2455.100 2469.530 >=0.5 PASS 11N20 Ant1 2412 12.720 2405.640 2418.360 >=0.5 PASS Ant2 2412 13.920 2405.640 2419.560 >=0.5 PASS Ant1 2437 14.730 2429.800 2444.530 >=0.5 PASS Ant2 2437 12.690 2430.640 2443.330 >=0.5 PASS Ant1 2462 12.720 2455.640 2468.360 >=0.5 PASS Ant2 2462 14.070 2455.460 2469.530 >=0.5 PASS 11N40 Ant1 2422 35.160 2404.420 2439.580 >=0.5 PASS Ant2 2422 32.640 2404.420 2437.060 >=0.5 PASS Ant1 2437 35.220 2419.420 2454.640 >=0.5 PASS Ant2 2437 33.900 2420.680 2454.580 >=0.5 PASS Ant1 2452 33.900 2435.680 2469.580 >=0.5 PASS Ant2 2452 30.180 2434.420 2464.600 >=0.5 PASS 11B Ant1 2412 12.690 2405.640 2418.330 >=0.5 PASS Ant2 2412 9.810 2406.960 2416.770 >=0.5 PASS Ant1 2437 9.630 2431.960 2441.590 >=0.5 PASS Ant2 2437 9.630 2431.960 2441.590 >=0.5 PASS Ant1 2462 9.840 2456.960 2466.800 >=0.5 PASS Ant2 2462 9.630 2456.960 2466.590 >=0.5 PASS 11N20MIMO Ant1 2412 12.720 2405.640 2418.360 >=0.5 PASS Ant2 2412 15.090 2403.840 2418.930 >=0.5 PASS Ant1 2437 12.720 2430.640 2443.360 >=0.5 PASS Ant2 2437 15.120 2428.840 2443.960 >=0.5 PASS Ant1 2462 12.720 2455.640 2468.360 >=0.5 PASS Ant2 2462 13.860 2455.070 2468.930 >=0.5 PASS Appendix of 210204040SZN-002 Test Graphs 11N4OMIMO_Ant1_2422 11N4OMIMO_Ant2_2422 11N4OMIMO_Ant1_2437 Appendix of 210204040SZN-002 11N4OMIMO_Ant2_2437 11N4OMIMO_Ant1_2452 11N4OMIMO_Ant2_2452 Appendix of 210204040SZN-002 11G_Ant1_2412 11G_Ant2_2412 11G_Ant1_2437 Appendix of 210204040SZN-002 11G_Ant2_2437 11G_Ant1_2462 11G_Ant2_2462 Appendix of 210204040SZN-002 11N20_Ant1_2412 11N20_Ant2_2412 11N20_Ant1_2437 Appendix of 210204040SZN-002 11N20_Ant2_2437 11N20_Ant1_2462 11N20_Ant2_2462 Appendix of 210204040SZN-002 11N40_Ant1_2422 11N40_Ant2_2422 11N40_Ant1_2437 Appendix of 210204040SZN-002 11N40_Ant2_2437 11N40_Ant1_2452 11N40_Ant2_2452 Appendix of 210204040SZN-002 11B_Ant1_2412 11B_Ant2_2412 11B_Ant1_2437 Appendix of 210204040SZN-002 11B_Ant2_2437 11B_Ant1_2462 11B_Ant2_2462 Appendix of 210204040SZN-002 11N20MIMO_Ant1_2412 11N20MIMO_Ant2_2412 11N20MIMO_Ant1_2437 Appendix of 210204040SZN-002 11N20MIMO_Ant2_2437 11N20MIMO_Ant1_2462 11N20MIMO_Ant2_2462 Appendix of 210204040SZN-002 Appendix B: Conducted Average Power Test Result SISO Mode Model Channel Frequency (MHz) Average Power(dBm) Limit (dBm) Verdict Ant 1 11b 1 2412 13.5 30 PASS 6 2437 13.39 30 PASS 11 2462 13.42 30 PASS 11g 1 2412 11.98 30 PASS 6 2437 12.1 30 PASS 11 2462 12.01 30 PASS 11n20 1 2412 11.89 30 PASS 6 2437 11.76 30 PASS 11 2462 11.5 30 PASS 11n40 3 2422 10.6 30 PASS 6 2437 10.5 30 PASS 9 2452 10.47 30 PASS Model Channel Frequency (MHz) Average Power(dBm) Limit (dBm) Verdict Ant 2 11b 1 2412 13.12 30 PASS 6 2437 13.02 30 PASS 11 2462 12.89 30 PASS 11g 1 2412 11.68 30 PASS 6 2437 11.75 30 PASS 11 2462 11.54 30 PASS 11n20 1 2412 11.65 30 PASS 6 2437 11.13 30 PASS 11 2462 11.36 30 PASS 11n40 3 2422 10.32 30 PASS 6 2437 10.42 30 PASS 9 2452 10.04 30 PASS Appendix of 210204040SZN-002 MIMO Mode Model Channel Frequency (MHz) Average Power(dBm) Total Average Power (dBm) Power Limit (dBm) Verdict Ant 1 Ant 2 11n20 1 2412 12.23 12.05 15.15 30.00 PASS 6 2437 11.89 12.15 15.04 30.00 PASS 11 2462 12.03 12.23 15.14 30.00 PASS 11n40 3 2422 10.6 10.23 13.50 30.00 PASS 6 2437 10.7 10.33 13.53 30.00 PASS 9 2452 10.68 10.12 13.45 30.00 PASS Appendix of 210204040SZN-002 Appendix C: Maximum power spectral density Test Result TestMode Antenna Channel Result Limit Verdict 11N4OMIMO Ant1 2422 -24.58 <=8 PASS Ant2 2422 -25.29 <=8 PASS total 2422 -21.91 <=8 PASS Ant1 2437 -24.36 <=8 PASS Ant2 2437 -25.2 <=8 PASS total 2437 -21.75 <=8 PASS Ant1 2452 -24.44 <=8 PASS Ant2 2452 -25.02 <=8 PASS total 2452 -21.71 <=8 PASS 11G Ant1 2412 -13.96 <=8 PASS Ant2 2412 -14.39 <=8 PASS Ant1 2437 -15.03 <=8 PASS Ant2 2437 -14.63 <=8 PASS Ant1 2462 -14.35 <=8 PASS Ant2 2462 -13.6 <=8 PASS 11N20 Ant1 2412 -14.27 <=8 PASS Ant2 2412 -15.07 <=8 PASS Ant1 2437 -15 <=8 PASS Ant2 2437 -15.04 <=8 PASS Ant1 2462 -14.01 <=8 PASS Ant2 2462 -14.59 <=8 PASS 11N40 Ant1 2422 -24.4 <=8 PASS Ant2 2422 -24.88 <=8 PASS Ant1 2437 -23.94 <=8 PASS Ant2 2437 -24.61 <=8 PASS Ant1 2452 -24.02 <=8 PASS Ant2 2452 -24.95 <=8 PASS 11B Ant1 2412 -14.65 <=8 PASS Ant2 2412 1.23 <=8 PASS Ant1 2437 1.53 <=8 PASS Ant2 2437 1.23 <=8 PASS Ant1 2462 1.4 <=8 PASS Ant2 2462 1.32 <=8 PASS 11N20MIMO Ant1 2412 -14.02 <=8 PASS Ant2 2412 -15.29 <=8 PASS total 2412 -11.60 <=8 PASS Ant1 2437 -14.05 <=8 PASS Ant2 2437 -14.42 <=8 PASS Appendix of 210204040SZN-002 total 2437 -11.22 <=8 PASS Ant1 2462 -13.74 <=8 PASS Ant2 2462 -14.85 <=8 PASS total 2462 -11.25 <=8 PASS Note:The Duty Cycle Factor is compensated in the graph. Appendix of 210204040SZN-002 Test Graphs 11N4OMIMO_Ant1_2422 11N4OMIMO_Ant2_2422 Appendix of 210204040SZN-002 11N4OMIMO_Ant1_2437 11N4OMIMO_Ant2_2437 Appendix of 210204040SZN-002 11N4OMIMO_Ant1_2452 11N4OMIMO_Ant2_2452 11G_Ant1_2412 Appendix of 210204040SZN-002 11G_Ant2_2412 11G_Ant1_2437 Appendix of 210204040SZN-002 11G_Ant2_2437 11G_Ant1_2462 11G_Ant2_2462 Appendix of 210204040SZN-002 11N20_Ant1_2412 11N20_Ant2_2412 Appendix of 210204040SZN-002 11N20_Ant1_2437 11N20_Ant2_2437 11N20_Ant1_2462 Appendix of 210204040SZN-002 11N20_Ant2_2462 11N40_Ant1_2422 Appendix of 210204040SZN-002 11N40_Ant2_2422 11N40_Ant1_2437 11N40_Ant2_2437 Appendix of 210204040SZN-002 11N40_Ant1_2452 11N40_Ant2_2452 Appen…

Text truncated - open the document above for the full version.

Test Setup Photos

Up to 1GHz Above 1G

Contact Information

Applicant

Xiaohong Huang(manager)
[email protected]13538217375Fax: 075528795016

Test Firm

Intertek Testing Services Shenzhen Ltd. Longhua BrHolly Ou
[email protected]+86 755 86140691

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz32.73 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. This device has 20 MHz and 40 MHz bandwidth mode. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be colocated or operating in conjunction with any other transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Shenzhen Urant Technology Co., Ltd

WIFI repeater - FCC ID 2A2F4-MT02-4 - Shenzhen Urant Technology Co., Ltd
2A2F4-MT02-4

WIFI repeater

Dec 01, 2024

Equipment Class

DTS - Digital Transmission System
U series repeater - FCC ID 2A2F4-U18 - Shenzhen Urant Technology Co., Ltd
2A2F4-U18

U series repeater

Dec 23, 2023

Equipment Class

DTS - Digital Transmission System
WIFI REPEATER - FCC ID 2A2F4-MT02 - Shenzhen Urant Technology Co., Ltd
2A2F4-MT02

WIFI REPEATER

Mar 02, 2022

Equipment Class

DTS - Digital Transmission System