FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. XINFENG 2D (FUJIAN)Material Technology Company LTD/
  3. 2A2HR-4E11314G01

2A2HR-4E11314G01Air Purification Device

XINFENG 2D (FUJIAN)Material Technology Company LTD
Air Purification Device - FCC ID 2A2HR-4E11314G01 - XINFENG 2D (FUJIAN)Material Technology Company LTD
Click to zoom

Application Details

Equipment Class
JAV - Other Non-Digital SDoC Devices
Date of Grant
Jul 12, 2021
Application Purpose
Original Equipment
Date of Application
Jul 12, 2021
Equipment Note
Air Purification Device
Company
XINFENG 2D (FUJIAN)Material Technology Company LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

2. Unique technology: Graphene-enhanced Photocatalytic Oxidation 1. Description Graph ene-enhanced photocatalytic oxidation process produces high volume of hydroxyl groups that have been proven to degrade VOC (volatile organic compounds) and kill airborne bacteria and viruses. Air Purification Device 4E11314G01 FCC ID:2A2HR-4E11314G01 Graphene-enhanced photocatalytic composite material Photocatalyst Components LED light board Connector 3. Exploded view of Module A 4. Specification Air Purification Device 4E11314G01 Length 534mm x Width 165mm x Depth 25.4mm Max 35V Typ 24V Min 20V Condition DC Max 2.4A Typ 2.1A Min 1.9A Condition 24V Max 58W Typ 51W Min 44W Condition 24V N.W 1450g Description Part Number Size Voltage Current Power Weight The temperature of the te st environment is 28 degrees Celsius, and the equipment is ventilated normally. FCC statements: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications or changes to this equipment. Such modifications or changes could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ‐ Reorient or relocate the receiving antenna. ‐ Increase the separation between the equipment and receiver. ‐Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ‐Consult the dealer or an experienced radio/TV technician for help.

External Photos

FCCID:2A2HR-4E11314G01 Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 Page2of2 ExternalPhotos EUTfrontview EUTbackview FCCID:2A2HR-4E11314G01 Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 Page3of2 EUTsideview

ID Label/Location Info

LableLocation:

Internal Photos

FCCID:2A2HR-4E11314G01 Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 Page2of2 InternalPhotos 1.EUTuncoverview FCCID:2A2HR-4E11314G01 Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 Page3of2

Test Report

NOTE:ThisreportisissuedbyMorlabandmaynotbecopiedwithoutwrittenpermissionfromMorlab.Thetestresultsinthis reportareonlyapplicabletospecificsamplesandspecifictests.Theinformationinthisreportcanbeverifiedandconfirmedon ourwebsite. Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 Page10f18 VersionV2.0 REPORTNo.:XM21060027E01 TESTREPORT APPLICANT: XINFENG2D(FUJIAN)MaterialTechnology CompanyLTD PRODUCTNAME: AirPurificationDevice MODELNAME: 4E11314G01 BRANDNAME: N/A FCCID: 2A2HR-4E11314G01 STANDARD(S): 47CFRPart15SubpartB RECEIPTDATE: 2021-06-28 TESTDATE: 2021-06-29 ISSUEDATE: 2021-07-12 Editedby: YamingLuo Approvedby: QijieXiao Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 Page20f18 VersionV2.0 REPORTNo.:XM21060027E01 DIRECTORY 1.TechnicalInformation ............................................................................................................... 3 1.1.ApplicantandManufacturerInformation ......................................................................... 3 1.2.EquipmentUnderTest(EUT)Description ........................................................................ 3 2.TestResults ................................................................................................................................. 4 2.1.AppliedReferenceDocuments ........................................................................................... 4 2.2.EUTSetupandOperatingConditions .............................................................................. 5 3.47CFRPart15SubpartBRequirements ............................................................................ 6 3.1.ConductedEmission ............................................................................................................. 6 3.2.RadiatedEmission ............................................................................................................... 10 AnnexATestUncertainty ........................................................................................................... 15 AnnexBTestingLaboratoryInformation .............................................................................. 16 AnnexCFCCStatements .......................................................................................................... 17 AnnexDMattersneedingattention ......................................................................................... 18 ChangeHistory VersionDateReasonforchange 1.02021-07-12Firstedition Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 Page30f18 VersionV2.0 REPORTNo.:XM21060027E01 1.TechnicalInformation Note:Providedbyapplicant. 1.1.ApplicantandManufacturerInformation Applicant:XINFENG2D(FUJIAN)MaterialTechnologyCompanyLTD ApplicantAddress:LongcangcunqianyuanNo.243Road,Dongyuan,Taiwanese investmentZone,Quanzhou,Fujian Manufacturer:XINFENG2D(FUJIAN)MaterialTechnologyCompanyLTD ManufacturerAddress:LongcangcunqianyuanNo.243Road,Dongyuan,Taiwanese investmentZone,Quanzhou,Fujian 1.2.EquipmentUnderTest(EUT)Description EUTType: AirPurificationDevice SerialNo: (N/A,marked#1bytestsite) ModelName: 4E11314G01 HardwareVersion:N/A SoftwareVersion: N/A AuxiliaryEquipment VoltageDriver PartNumber:SMT-024-150VWSW ACInput:110-277VAC,50/60Hz,1.8A DCOutput24VDC,6.25A,150Wmax Note: 1.Foramoredetaileddescription,pleaserefertospecificationoruser’smanualsuppliedbythe applicantand/ormanufacturer. Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 Page40f18 VersionV2.0 REPORTNo.:XM21060027E01 2.TestResults 2.1.AppliedReferenceDocuments Theobjectiveofthereportistoperformtestingaccordingto47CFRPart15SubpartB: No.IdentityDocumentTitle 147CFRPart15SubpartBRadioFrequencyDevices Testdetaileditems/sectionrequiredbyFCCrulesandresultsareasbelow: No.SectionDescriptionTestDateTestEngineerResult Method determination /Remark 115.107ConductedEmission2021.06.29QijieXiaoPASSNodeviation 215.109RadiatedEmission2021.06.29QijieXiaoPASSNodeviation NOTE:ThetestswereperformedaccordingtothemethodofmeasurementsprescribedinANSI C63.4-2014. Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 Page50f18 VersionV2.0 REPORTNo.:XM21060027E01 2.2.EUTSetupandOperatingConditions Frequencyrangewasinvestigated:Conductedemissiontest:from150kHzto30MHz;Radiated emissiontest:from30MHzto1000MHz. TestItem RadiatedEmission Mode1:EUTON ConductedEmission Mode1:EUTON Duringthemeasurement,theenvironmentalconditionswerewithinthelistedranges: Temperature(°C):15-35 RelativeHumidity(%):30-60 AtmosphericPressure(kPa):86-106 Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 Page60f18 VersionV2.0 REPORTNo.:XM21060027E01 3. 47CFRPart15SubpartBRequirements 3.1.ConductedEmission 3.1.1.Requirement AccordingtoFCCsection15.107,exceptforaClassAdigitaldevicethatisdesignedtobe connectedtothepublicutility(AC)powerline,theradiofrequencyvoltagethatisconductedback ontotheACpowerlineonanyfrequencyorfrequencieswithintheband150kHzto30MHzshall notexceedthelimitsinthefollowingtable,asmeasuredusinga50μH/50ohmsLISN. Frequencyrange (MHz) ConductedLimit(dBμV) Quasi-peakAverage 0.15-0.5066to5656to46 0.50-55646 5-306050 NOTE: a)ThelimitsubjectstotheClassBdigitaldevice. b)Thelowerlimitshallapplyatthebandedges. c)Thelimitdecreaseslinearlywiththelogarithmofthefrequencyintherange0.15- 0.50M…

Text truncated - open the document above for the full version.

Test Setup Photos

FCCID:2A2HR-4E11314G01 Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 Page1of1 Test-SetupPhotos 1.ConductedEmission 2.RadiatedEmission(30MHz-1GHz)

Contact Information

Applicant

Xueting Zhang(Engineer)
[email protected]+86 13705066072Fax: +86 0595-22412574

Test Firm

Kehu-Morlab Test LaboratoryLiu Anne
[email protected]+86 755 36698566

Technical Specifications

#Rule PartsFrequency RangePower Output
115B--
Confidentiality
Long Term

Other Applications from XINFENG 2D (FUJIAN)Material Technology Company LTD

Air Purification Device - FCC ID 2A2HR-4E25959G01 - XINFENG 2D (FUJIAN)Material Technology Company LTD
2A2HR-4E25959G01

Air Purification Device

Jul 04, 2022

Equipment Class

JAV - Other Non-Digital SDoC Devices