Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Integration Manual Name Dept. date sheet of Schreiber Simon R&D/HWR-MUL 16.02.2024 1 7 AUMA Riester GmbH & Co. KG Tel +49 7631 809-0 Aumastr. 1 Fax +49 7631 809-1250 79379 Müllheim, Germany [email protected] www.auma.com Plastic Carrier 1 Introduction The module with the associated PCB antenna is specially designed for various expansion stages of the PROFOX electric actuator. The antenna in particular is adapted for the installation position in the housing. For this reason, it is necessary to adhere to the installation specifications. The following steps describe the integration of the module and the associated antenna. 2 Installation specifications 2.1 Integration steps 1. The module must be pushed completely into a plastic carrier for a fixed position (see Figure 1) 2. The Antenna Z135.074 must be pushed into the screw plug Z136.746 screwed into a metal housing (see Figure 2) 3. After integrating the module Z139.910 and Z135.074, the antenna cable must be connected to the U.FL Connector on the module and the complete plastic carrier ist pushed in a metal housing (see Figure 3) 4. The plastic carrier must be pushed down completely (see Figure 4) 5. The regulations were only checked with a completely closed metal housing. (see Figure 5) Figure 1: Integration of the Module Z139.910 in a plastic carrier Integration Manual Name Dept. date sheet of Schreiber Simon R&D/HWR-MUL 16.02.2024 2 7 AUMA Riester GmbH & Co. KG Tel +49 7631 809-0 Aumastr. 1 Fax +49 7631 809-1250 79379 Müllheim, Germany [email protected] www.auma.com PCB Antenna Z135.074 with Antenna Cable Metal housing Screw Plug Z136.746 Figure 2: Installation of the Antenna Z135.074 Figure 3: Antenna attached to the U.FL Connector on the Module Figure 4: Z135.074 Antenna with Antenna Cable Integration Manual Name Dept. date sheet of Schreiber Simon R&D/HWR-MUL 16.02.2024 3 7 AUMA Riester GmbH & Co. KG Tel +49 7631 809-0 Aumastr. 1 Fax +49 7631 809-1250 79379 Müllheim, Germany [email protected] www.auma.com Screw Plug Z136.746 Figure 5: Integrated Module Z139.910 and Antenna Z135.074 Figure 6: Final assembled unit in a completely closed metal housing Integration Manual Name Dept. date sheet of Schreiber Simon R&D/HWR-MUL 16.02.2024 4 7 AUMA Riester GmbH & Co. KG Tel +49 7631 809-0 Aumastr. 1 Fax +49 7631 809-1250 79379 Müllheim, Germany [email protected] www.auma.com 3 Regulatory Notices 3.1 Englisch This supplement applies to the following actuators: PROFOX PF-Q80 – PF-Q600 / PF-M25 – PF- M100 PROFOX PF-Q80X – PF-Q600X / PF- M25X – PF-M100X In addition to the indications made in the operation instructions, the notes described in this supplement must be heeded for the above mentioned actuators. This device complies with Part 15 of the FCC Rules [and with Industry Canada licence-exempt RSS standard(s)]. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the operation instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his or her own expense! The End User must ensure that FCC labeling requirements are met. This includes a clearly visible label on the outside of the Endproducts enclosure specifiying the appropriate AUMA FCC identifier for this module The FCC identifier is: 2A2OUAUMAPF00002 This FCC identifier is valid for the Z123.664 Module. The end product must in any case be labelled on the exterior with: Contains FCC ID: 2A2OUAUMAPF00002 FCC Notice Safety instructions Changes or modifications made to this equipment not expressly approved by AUMA Riester GmbH & Co. KG may void the FCC authorization to operate this equipment! FFC Labelling (USA) Integration Manual Name Dept. date sheet of Schreiber Simon R&D/HWR-MUL 16.02.2024 5 7 AUMA Riester GmbH & Co. KG Tel +49 7631 809-0 Aumastr. 1 Fax +49 7631 809-1250 79379 Müllheim, Germany [email protected] www.auma.com The End User must ensure that FCC labeling requirements are met. This includes a clearly visible label on the outside of the Endproducts enclosure specifiying the appropriate AUMA FCC identifier for this module. The ISED identifier is: 27543-AUMAPF00002 This IC identifier is valid for the Z139.910 Module. The end product must in any case be labelled on the exterior with: “Contains IC ID: 27543-AUMAPF00002” The electric actuator complies, with regard to the Bluetooth module used, with the following standards in compliance with the RED (2014/53/EU) articles: EMC: EN 301489-1 V2.2.1 EN 301489-17 V3.2.0 Radio: EN 300328 V2.2.2 ISED Labelling (Canada) European Conformity Integration Manual Name Dept. date sheet of Schreiber Simon R&D/HWR-MUL 16.02.2024 6 7 AUMA Riester GmbH & Co. KG Tel +49 7631 809-0 Aumastr. 1 Fax +49 7631 809-1250 79379 Müllheim, Germany [email protected] www.auma.com 3.2 French Ce supplément s’applique aux servomoteurs suivants: PROFOX PF-Q80 – PF-Q600 / PF-M25 – PF-M100 PROFOX PF-Q80X – PF-Q600X PROFOX PF-M25X – PF-M100X En outres des indications renfermées dans les instructions de service, les références décrites dans le présent supplément doivent être respectées pour les servomoteurs cités ci-dessus. Cet appareil est conforme à la partie 15 des règles de la FCC [et aux normes RSS exemptes de licence d'Industrie Canada]. Son fonctionnement est soumis aux deux conditions suivantes : 1. Cet appareil ne doit pas causer d'interférence…
Text truncated - open the document above for the full version.
AUMA Riester GmbH & Co. KG Tel +49 7631 809-0 Aumastr. 1 Fax +49 7631 809-1250 79379 Müllheim, Germany [email protected] www.auma.com AUMA Riester GmbH & Co. KG Michael Noll Aumastrasse 1, D-79379 Muellheim Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA 24.01.2024 Attestation Statement according to 2.911(d)(5)(i) and 2.911(d)(5)(ii) FCC ID: 2A2OUAUMAPF00002 TO WHOM IT MAY CONCERN: Hereby we certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Further we certify that, as of the date of the filing of the application, AUMA Riester GmbH & Co. KG is not identified on the Covered List as an entity producing “covered” equipment. Sincerely _______________ (signature & company stamp) AUMA Riester GmbH & Co. KG Aumastrasse 1, D-79379 Muellheim Michael Noll +4976318090 [email protected]
AUMA Riester GmbH & Co. KG Tel +49 7631 809-0 Aumastr. 1 Fax +49 7631 809-1250 79379 MĂĽllheim, Germany [email protected] www.auma.com AUMA Riester GmbH & Co. KG Michael Noll Aumastrasse 1, D-79379 Muellheim Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA 24.01.2024 Attestation Statement according to 2.911(d)(7) FCC ID: 2A2OUAUMAPF00002 TO WHOM IT MAY CONCERN: We, AUMA Riester GmbH & Co. KG with FCC Registration Number (FRN) 0031177256 designate AUMA Actuators, Inc., to act as U.S. agent for service of process. AUMA Actuators, Inc.with FCC Registration Number (FRN) 0034905414 hereby acknowledges the obligation of the U.S. agent for service of process. Further AUMA Riester GmbH & Co. KG accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Sincerely _______________ (signature & company stamp) _______________ (signature & company stamp) AUMA Riester GmbH & Co. KG Aumastrasse 1, D-79379 Muellheim Michael Noll +4976318090 [email protected] AUMA Actuators, Inc. 100 Southpointe Blvd, Canonsburg, PA 15317, USA Craig Mizer 724-743-2862 [email protected]
Document Version 1.1 2020-10-30 LONG-TERM CONFIDENTIALITY REQUEST for Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 TO WHOM IT M AY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request Long-Term Confidentiality for the following product: For the product stated above, we request Long-Term Confidentiality for exhibits which contain Block Diagram, Operational Description, Parts List/Tune Up Info, Schematics, SDR Software/Security Info. The above exhibits contain ou r trade secrets and proprietary information that could be of benefit to o ur competitors. This information will not be publicly available. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Company Name: Phone: Company Address: Fax: E-mail: Contact Name: Signature: Signature Date: Check your GC here. Click Grantee Search. FCC I D: Grantee Code Equipment Product Code
Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 Certification and Engineering Bureau Innovation, Science and Economic Development Canada Spectrum Engineering Branch 3701 Carling Avenue, Building 94 Ottawa, Ontario K2H 8S2 Subject: FCC / ISED Modular Approval Statement FCC ID: CN: (Company Number) UPN: (Unique Product Number) HVIN: (Hardware Version Id. Number) PMN: (Product Marketing Name) HMN: (Host Marketing Name) FVIN: ( Firmware Version Id . Number) TO WHOM IT MAY CONCERN Pursuant to Paragraphs RSP-100, Issue 12 and CFR § 15.212, we herewith declare for our module. Modular approval requirement Yes No * (a) The radio elements shall have the radio frequency circuitry shielded. Physical/discrete and tuning capacitors may be located external to the shield, but shall be on the module assembly. * Please provide a detailed explanation if the answer is “No.”: (b) If the module has modulation/data input(s), they shall be buffered in order to ensure that the module will comply with the requirements set out in the applicable Radio Standards Specification (RSS) and Part 15 under conditions of excessive data rates or over-modulation. * Please provide a detailed explanation if the answer is “No.”: (c) The module shall have its own power supply regulation on the module itself. This is to ensure that the module will comply with the requirements set out in the applicable standard regardless of the design of the power supplying circuitry in the host product that houses the module. * Please provide a detailed explanation if the answer is “No.”: (d) The module shall comply with the provisions for external power amplifiers and antennas detailed in the applicable RSS and rule part. The equipment certification application shall contain: i.a detailed description of the configuration of highest antenna gain for each type of transmitting antenna for licence-exempt modules; ii.the maximum transmitting antenna gain for licence modules; and iii. a detailed description of the configuration of lowest antenna gain for each type of receiving antenna for Dynamic Frequency Selection (DFS) modules with removable antenna(s). * Please provide a detailed explanation if the answer is “No.”: Modular Approval Attestation RSP-100, Issue 12, August 2019 Check your CN here. Check your GC here. Click Grantee Search. Grantee Code Equipment Product Cod e If you have any questions, please feel free to contact us at the address shown below Best regards, INFO for applicant: Limited Modolar Approval (LMA) may be granted when one or more of the requirements in the table above cannot be demonstrated. LMA will also be issued in those instances where applicants can demonstrate that they will retain control over the final installation of the device, such that compliance of the end product is assured. In such cases, an operating condition on t he LMA for the module must state that the module is only approved for use when installed in devices produced by a specificmanufacturer. When LMA is sought, the application for equipment certification must specifically state how control of the end product, into which the module will be installed, will be maintained, such that full compliance of the end product is always ensured. Company Name: Phone: Company Address: Fax: E-mail: Contact Name: Signature: Signature Date: Document Version 2.1 2020-10-30 Modular approval requirement Yes No * (e) The module shall be tested for compliance with the applicable standard in a stand-alone configuration (i.e. the module shall not be inside another product during testing). * Please provide a detailed explanation if the answer is “No.”: (f) The module complies or will comply with applicable RSS-102 exposure requirements and any applicable FCC RF exposure requirement (§§1.1307(b), 1.1310, 2.1091, and 2.1093) in its intended configuration/integration in a host. * Please provide a detailed explanation if the answer is “No.”: (g) The module must be labeled with its permanently affixed label (indicating ISED certification number, HVIN and FCC identifier), or use an electronic display (see KDB Publication 784748 and RSP-100, section 5). * Please provide a detailed explanation if the answer is “No.”: (h) The module must comply with all specific rules applicable to the transmitter, including all the conditions provided in the integration instructions by the grantee. * Please provide a detailed explanation if the answer is “No.”: (i) ( Only applicable for FCC) The module must contain a permanently attached antenna, or contain a unique antenna connector, and be marketed and operated only with specific antenna(s), per §§ 15.203, 15.204(b), 15.204(c), 15.212(a), 2.929(b). For further information concerning antenna connectors see: DA-00-1087. * Please provide a detailed explanation if the answer is “No.”:
Registered Office: Muellheim, court of registration: Freiburg HRA 300276, phG: AUMA Riester Verwaltungsgesellschaft mbH, Registered Office: Muellheim, court of registration: Freiburg HRB 300424, Managing Directors: Dr. Jörg Hoffmann (Chair), Ferdinand Dirnhofer AUMA Riester GmbH & Co. KG Aumastr. 1 79379 Müllheim, Germany www.auma.com Tel +49 7631 809-0 Fax +49 7631 809-1250 [email protected] AUMA Riester GmbH & Co. KG, Postfach 13 62, D-79373 Müllheim, Germany Innovation, Science and Economic Development Canada (ISED) Michael Noll Tel +49 7631 809 1154 Fax +49 7631 809-7-1154 [email protected] Your reference Your letter dated Our reference Department Date Mr. Noll CER 2024-02-20 Confirmation To Whomsoever It May Concern I hereby certify that the module Z139.910 with the following references is approved by this certification process will not be sold to third parties. - FCC-ID: 2A2OUAUMAPF00002 - IC -ID: 27543-AUMAPF00002 - HVIN: A01 The module Z139.910 is exclusively used in the product "PROFOX" mentioned in the documents. Kind regards AUMA Riester GmbH & Co. KG i. V. Michael Noll Group Leader Certification R&D/CER-MUL
Annex A101 - Photographs No.1-6108-23-03-01_TR1-A101-R01 September 04, 2024 DescriptionExternal photographs of EUT This document is electronically signed and valid without handwritten signature. Public keys for verification of the electronic signatures can be requested at the testing laboratory. Authorized Andreas Curette Testing Manager Radio Labs cetecom advanced GmbH UntertĂĽrkheimer Str. 6-10, 66117 SaarbrĂĽcken Document No. 1-6108-23-03-01_TR1-A101-R01 Release 1 - Page 1 of 6 Photo 1 Photo 2 cetecom advanced GmbH UntertĂĽrkheimer Str. 6-10, 66117 SaarbrĂĽcken Document No. 1-6108-23-03-01_TR1-A101-R01 Release 1 - Page 2 of 6 Photo 3 Photo 4 cetecom advanced GmbH UntertĂĽrkheimer Str. 6-10, 66117 SaarbrĂĽcken Document No. 1-6108-23-03-01_TR1-A101-R01 Release 1 - Page 3 of 6 Photo 5 Photo 6 cetecom advanced GmbH UntertĂĽrkheimer Str. 6-10, 66117 SaarbrĂĽcken Document No. 1-6108-23-03-01_TR1-A101-R01 Release 1 - Page 4 of 6 Photo 7 Photo 8 cetecom advanced GmbH UntertĂĽrkheimer Str. 6-10, 66117 SaarbrĂĽcken Document No. 1-6108-23-03-01_TR1-A101-R01 Release 1 - Page 5 of 6 Photo 9 Photo 10 - END OF DOCUMENT - cetecom advanced GmbH UntertĂĽrkheimer Str. 6-10, 66117 SaarbrĂĽcken Document No. 1-6108-23-03-01_TR1-A101-R01 Release 1 - Page 6 of 6
Theme: Label/Label Location Name Dept. path, file name date sheet of Schreiber Simon R&D/HWR-MUL L:\Projekte\P00178 BASE Antrieb\03 Entwicklung\02 Elektronik\01 Hardware\01_AllgemeineDokumentation\BT- Zertifizierung\BGM210P Modul\03 Unterlagen fĂĽr USA_Kanada Zulassung\08_Label Location.docx 18.12.2023 1 2 AUMA Riester GmbH & Co. KG Tel +49 7631 809-0 Aumastr. 1 Fax +49 7631 809-1250 79379 MĂĽllheim, Germany [email protected] www.auma.com 1 Labeling of the Module Z139.910 The Label on the Module will be placed at the indicated Position. Figure 1: Label Location on Module Z139.910 FCC-ID: 2A2OUAUMAPF00002 IC-ID: 27543-AUMAPF00002 HVIN: A01 Theme: Label/Label Location Name Dept. path, file name date sheet of Schreiber Simon R&D/HWR-MUL L:\Projekte\P00178 BASE Antrieb\03 Entwicklung\02 Elektronik\01 Hardware\01_AllgemeineDokumentation\BT- Zertifizierung\BGM210P Modul\03 Unterlagen fĂĽr USA_Kanada Zulassung\08_Label Location.docx 18.12.2023 2 2 AUMA Riester GmbH & Co. KG Tel +49 7631 809-0 Aumastr. 1 Fax +49 7631 809-1250 79379 MĂĽllheim, Germany [email protected] www.auma.com 2 Labelling of Endproduct The end products must be marked legibly from the outside with the following label: Contains FCC ID: 2A2OUAUMAPF00002 Cointains IC ID: 27543-AUMAPF00002
Released under NDA to Cetecom Advanced GmbH Stefan Boes 2024-06-25
© cetecom advanced GmbH Page 1 of 2 BNetzA-CAB-02/21-102 RF Exposure Evaluation according to KDB 447498 D01 v06 Report identification number: 1-6108_23-01-07_TR1-R01_MPE_FCC Certification numbers and labeling requirements FCC ID 2A2OUAUMAPF00002 This test report is electronically signed and valid without handwritten signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Document authorised: Alexander Hnatovskiy Eric Tuettmann Lab Manager Testing Manager Radio Labs Radio Labs Report no.: 1-6108_23-01-07_TR1-R01 © cetecom advanced GmbH Page 2 of 2 1. MPE at given distance (KDB 447498 D01 General RF Exposure Guidance v06) Equation from page 18 of OET Bulletin 65, Edition 97-01 S = PG / 4π R 2 where: S = Power density P = Power input to the antenna G = Antenna gain R = Distance to the center of radiation of the antenna PG = Output Power including antenna gain The table below is excerpted from Table 1B of 47 CFR 1.1310 titled “Limits for Maximum Permissible Exposure (MPE), Limits for General Population/Uncontrolled Exposure” Frequency Range (MHz) Power Density (mW/cm 2 ) Averaging Time (minutes) 300 -1500 f/1500 30 1500 - 100000 1.0 30 where f = Frequency (MHz) 2. EUT technologies Declared minimum safety distance: 20 cm f Min f Max # P ERP P EIRP P RF Exp S Result S Limit % Bluetooth LE 2402 2480 A N/A 6.6 6.6 0.001 1.00 0.09% Output Power [dBm] SRD Technology Frequency [MHz] Reference Power Density [mW/cm²] Share of Limit Notes: - Max rated conducted output power taken from customer’s tune up info Referenced Documents: # Results from: A Test Report 1-6108_23-01-05 3. Conclusion This prediction demonstrates the following: The power density levels for FCC at a distance of 20 cm are below the maximum levels allowed by regulations. Conclusion: RF exposure evaluation is not required.
TEST REPORT Test report no.: 1-6108_23-03-02_TR1-R1 Testing laboratory Applicant cetecom advanced GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken / Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: https://cetecomadvanced.com e-mail: [email protected] Accredited Testing Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2018-03) by the Deutsche Akkreditierungsstelle GmbH (DAkkS). The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate with the registration number: D-PL-12047-01-00. ISED Testing Laboratory Recognized Listing Number: DE0001 FCC designation number: DE0002 AUMA Riester GmbH & Co. KG Aumastr. 1 79379 Müllheim / GERMANY Phone: +49 7631 809-0 Contact: Michael Noll e-mail: [email protected] Manufacturer AUMA Riester GmbH & Co. KG Aumastr. 1 79379 Müllheim / GERMANY Test standard/s FCC - Title 47 CFR Part 15 FCC - Title 47 of the Code of Federal Regulations; Chapter I; Part 15 - Radio frequency devices RSS - 247 Issue 3 Digital Transmission Systems (DTSs), Frequency Hopping Systems (FHSs) and Licence-Exempt Local Area Network (LE-LAN) Devices For further applied test standards please refer to section 3 of this test report. Test Item Kind of test item: BTLE module Model name: PROFOX FCC ID: 2A2OUAUMAPF00002 ISED certification number: 27543-AUMAPF00002 Frequency: 2400 MHz to 2483.5 MHz Technology tested: Bluetooth ® LE Antenna: Integrated PCB antenna Power supply: 3.3 V / 24 V DC by external power supply Temperature range: -30°C to +70°C This test report is electronically signed and valid without handwritten signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report authorized: Test performed: On behalf of Marco Bertolino Michael Dorongovski Supervisor Radio Services Lab Manager Radio Labs Radio Labs Test report no.: 1-6108_23-03-02_TR1-R1 © cetecom advanced GmbH Page 2 of 47 1 Table of contents 1 Table of contents .................................................................................................................................... 2 2 General information ................................................................................................................................ 3 2.1 Notes and disclaimer .................................................................................................................... 3 2.2 Application details ........................................................................................................................ 3 2.3 Test laboratories sub-contracted .................................................................................................. 3 3 Test standard/s, references and accreditations ....................................................................................... 4 4 Reporting statements of conformity – decision rule ................................................................................ 5 5 Test environment.................................................................................................................................... 6 6 Test item ................................................................................................................................................ 6 6.1 General description ...................................................................................................................... 6 6.2 Additional information .................................................................................................................. 6 7 Sequence of testing ................................................................................................................................ 7 7.1 Sequence of testing radiated spurious 9 kHz to 30 MHz ................................................................ 7 7.2 Sequence of testing radiated spurious 30 MHz to 1 GHz ............................................................... 8 7.3 Sequence of testing radiated spurious 1 GHz to 18 GHz ................................................................ 9 7.4 Sequence of testing radiated spurious above 18 GHz .................................................................. 10 8 Description of the test setup ................................................................................................................. 11 8.1 Shielded semi anechoic chamber ................................................................................................ 12 8.2 Shielded fully anechoic chamber ................................................................................................ 13 8.3 Radiated measurements > 18 GHz .............................................................................................. 14 8.4 Conducted measurements system .............................................................................................. 15 8.5 AC conducted ............................................................................................................................. 16 9 Measurement uncertainty ..................................................................................................................... 17 10 Summary of measurement results ..................................................................................................... 18 11 Additional comments ........................................................................................................................ 19 12 Measurement results ........................................................................................................................ 20 12.1 System gain ............................................................................................................................ 20 12.2 Power spectral density ............................................................................................................…
Text truncated - open the document above for the full version.
Annex A102 - Photographs No.1-6108-23-03-01_TR1-A102-R01 September 04, 2024 DescriptionTest set-up photographs This document is electronically signed and valid without handwritten signature. Public keys for verification of the electronic signatures can be requested at the testing laboratory. Authorized Andreas Curette Testing Manager Radio Labs cetecom advanced GmbH UntertĂĽrkheimer Str. 6-10, 66117 SaarbrĂĽcken Document No. 1-6108-23-03-01_TR1-A102-R01 Release 1 - Page 1 of 5 Photo 1 Photo 2 cetecom advanced GmbH UntertĂĽrkheimer Str. 6-10, 66117 SaarbrĂĽcken Document No. 1-6108-23-03-01_TR1-A102-R01 Release 1 - Page 2 of 5 Photo 3 Photo 4 cetecom advanced GmbH UntertĂĽrkheimer Str. 6-10, 66117 SaarbrĂĽcken Document No. 1-6108-23-03-01_TR1-A102-R01 Release 1 - Page 3 of 5 Photo 5 Photo 6 cetecom advanced GmbH UntertĂĽrkheimer Str. 6-10, 66117 SaarbrĂĽcken Document No. 1-6108-23-03-01_TR1-A102-R01 Release 1 - Page 4 of 5 Photo 7 - END OF DOCUMENT - cetecom advanced GmbH UntertĂĽrkheimer Str. 6-10, 66117 SaarbrĂĽcken Document No. 1-6108-23-03-01_TR1-A102-R01 Release 1 - Page 5 of 5
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 10.00 mW |