Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Dec 16, 2025
Application Purpose
Original Equipment
Equipment Note
Wireless Data Logger
Frequency Range
2402.00000000 - 2480.00000000
Company
SkyCell AG
Country
Switzerland

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 Hardware • Manual • IoT ULD Track • Phone/Tablet with Network + Camera • Screwdriver (for logger removal only) IoT ULD Track Step-By-Step Installation Manual Model No. MR 814 B 5’1 1.1 Package Contents 1.2 Required Installation Equipment Web App asset-pairing.skymind.com contact: [email protected] 2 Description of Installation 2.1 Logger activation Ensure you are within 100 m of a SkyCell Gateway before proceeding. Press and hold the button on the housing for 5–10 seconds, then release it. The LED stays off while the button is pressed and blinks green once after release to confirm logger activation has been started. LED indicator Purple Short Button Press Shelf mode (no measurement, no transmission) Green Short Button Press Logger is ON (measuring and transmitting) Blue Automatic Short blink during transmission Red Automatic Low battery / Error state Color When it lights Meaning The LED is normally off. It lights up on button press or automatically. 5-10 sec Users are solely responsible for safely and securely installing or mounting the logger. This includes following proper proce- dures, using appropriate tools and materials, and taking all necessary precautions to prevent system damage or unauthorized access. Illustrations in this manual are intended for general guidance only. Logger and pallet appearances may differ, and the illustrations provided may not depict real-world configurations with complete accuracy. Before installation, always ensure that the logger does not obstruct the anchor points specified by the pallet and net manufacturers to prevent damage to the hard- ware. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Battery Safety Information CAUTION: Risk of explosion if the device is opened or tampered with. This product contains a sealed battery that cannot be replaced. Do not attempt to open, disassemble, or service the device. Dispose of the device ac- cording to local regulations for battery-containing electronic products. WARNING - Chemical Burn Hazard: This product con- tains a button cell battery. Do not ingest the battery. Swallowing a button cell battery can cause severe internal burns within 2 hours and may lead to death. Keep the device away from children. If you suspect the battery has been swallowed or placed inside any part of the body, seek immediate medical attention. Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installa- tion. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncon- trolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. RF Power: [email protected] Flextronics Manufacturing (Zhuhai) Co., Ltd. Xin Qing Science & Technology Industrial Park, Jin An Town, Doumen, Zhuhai, Guangdong, China ProblemPossible Solution I get an error screen on the app reading “Logger Inactive”. Ensure you’re in a 100 meter range of a Gateway. If you already are, then use another logger and try again in 5 minutes. If it still doesn’t work, contact support. While turning on the logger (step 3.1), the LED blinks purple. The LED blinks purple means the logger is still in shelf mode. Wait 10 seconds and repeat the procedure. While pairing the logger to the pallet (step 3.2), the app shows an error that a “logger is already paired with this pallet”, but no logger is attached to the pallet. In the app, select the “Remove” button and give the reason that the “logger is missing”. Then proceed with the pairing as normal (step 3.2). The logger is visibly damaged. Do not install the logger. Use an alternative logger instead and contact support by e-mail: [email protected] The logger does not blink green (or purple, see above) during the installation process. The logger number is not found in the system. Any other problem? 4 Troubleshooting Once the installation point is identified, install the logger by firmly press- ing it into the seat track with your hand. Do not use a hammer or any other tools, as they may damage the logger. 2.4 Install the logger in the pallet 3.2 Removing the logger from the pallet Use a screwdriver to remove the logger from the pallet. 2.2 Pair the pallet with the logger Log into the SkyTrack app or visit the Web App and follow the steps to link the logger and the pallet. Web App asset-pairing.skymind.com 2.3 Identify installation location on pallet The logger must be installed on the short side of the pallet. The exact position depends on the ULD Type. OK if green zone is damagedDon’t install herePreferred Inst…

Text truncated - open the document above for the full version.

Attestation Statements

Applicant Declaration QSF27-14-04 Rev 1.4 April 25, 2025 Page 1 of 1 Original Issue: Jan. 4, 2021 SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States Protected Applicant Legal Business Name SkyCell AG Address Bahnhofplatz, CH-6300 Zug, Switzerland FRN 0031226079 Grantee Code 2A2SN FCC ID: 2A2SN-SKYCELL814B Authorized Contact Name Arndt von Bieren Contact Phone +41782527108 Contact Email [email protected] I, the undersigned, certify that I am an authorized signatory for the Applicant and therefore declare; a) in accordance with 47CFR2.911(d), all of the statements herein and the exhibits attached hereto are true and correct to the best of my knowledge and belief. b) in accepting a Grant of Equipment Authorization issued by a TCB, under the authority of the FCC, as a result of the representations made in this application, the Applicant is responsible for: (1) labeling the equipment with the exact FCC ID as specified in this application, (2) compliance statement labeling pursuant to the applicable rules, (3) compliance of the equipment with the applicable technical rules, c) if the Applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCC’s technical requirements. d) in accordance with 47 CFR 2.909 and KDB394321, the Applicant has read, understood and agrees to accept that they are the responsible party and agree to abide by their responsibilities as specified under 47 CFR 2.909 and KDB394321. e) in accordance with ISO 17065, FCC KDB641163, FCC KDB610077, KDB394321 and RSP-100, the Applicant has read, understood, accepts and agrees to abide by the post market surveillance requirements. (1) the Applicant understands, accepts and agrees that a sample may be requested for surveillance testing. (2) the Applicant shall make provisions to always have a production sample available upon request by SGS, FCC and/or ISED. (3) the Applicant shall, upon request by SGS, at the Applicant’s expense, provide a production sample of the requested product to SGS, FCC and/or ISED as instructed. The sample shall include all support devices, cables, software, accessories or other hardware or software required for evaluation, review, certification and audit surveillance of products certified by SGS. f) neither the Applicant nor any party to the application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862 because of a conviction for possession or distribution of a controlled substance. See 47CFR 1.2002(b) for the definition of a “party” for these purposes. g) the Applicant has read, understood, accepts and agrees to abide by the SGS North America, Inc. terms and conditions as specified in the TCB Application Form 731 (QSF27-14-01). Link to CFRs: https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 Link to KDBs: https://apps.fcc.gov/oetcf/kdb/index.cfm Link to RSP-100: https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html Link to the Covered List: Covered List Applicant Signature: Date: 2025/12/3 Print Name: Arndt von Bieren Title: Deputy VP of SW&IoT *NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database Docusign Envelope ID: 6D63A9FE-07E7-49B5-BC2A-ACF8F91D8D94

Attestation Statements

FCC COVERED LIST DECLARATION LETTER Page 1 of 1 Revision 1.0 SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States Protected Applicant Legal Business Name SkyCell AG Address Bahnhofplatz, CH-6300 Zug, Switzerland FRN 0031226079 Grantee Code 2A2SN FCC ID: 2A2SN-SKYCELL814B Authorized Contact Name Arndt von Bieren Contact Phone +41782527108 Contact Email [email protected] SkyCell AG (“the applicant”) certifies: - the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. - as of the date of the filing of the application, the applicant is not identified on the Covered list, established pursuant to §1.50002, as an entity producing “covered” equipment. - the software to be loaded prior to marketing of the equipment identified above is not “covered” software manufactured by any entity including predecessors, successors, parents, subsidiaries, affiliates or any entity which has rebranded or relabeled the software produced by the entity(ies) identified on the “Covered List”. - the device is not capable of storing or running software listed on the covered list and therefore is not inherently compliant. NOTE: Justification/evidence explaining how compliance is met must accompany this letter Link to the Covered List: Covered List Applicant Signature: Date: 2025/12/3 Print Name: Arndt von Bieren Title: Deputy VP of SW&IoT *NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database Justification/evidence: 1. The device is not capable of storing or running any software. Please refer to the user manual. 2. The equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Please refer to Internal photo. Docusign Envelope ID: 6D63A9FE-07E7-49B5-BC2A-ACF8F91D8D94

Attestation Statements

SkyCell AG Protected U.S. Agent Designation for Service of Process (Applicant and U.S. Agent are Separate Parties) TO: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 ATTENTION: FCC Certification – Section 2.911(d)(7) Information Designated U.S. Agent Company Name: SkyCell North America Inc. FRN: 0037137213 Contact Name: Marco Quiros Street Address: C/O WG Service Partners LLC 100 Wall Street, 10th FL New York, 10005 Telephone No: 954 901 0507 Email: [email protected] This letter is to confirm that we (“the Designated U.S. Agent) have accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by section 47 CFR 2.911(d)(7) on behalf of the Applicant noted below. U.S. Agent Signature: Date: 2025/12/4 Signed by (Printed Name/Title): Marco Quiros The Applicant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. Applicant Company name: SkyCell AG FRN: 0031226079 Grantee Code: 2A2SN FCC ID: 2A2SN-SKYCELL814B Contact Name: Arndt von Bieren Street Address: Bahnhofplatz City/Province/Zip: Zug, N/A, 6300 Telephone No: +41782527108 Email: [email protected] Applicant Signature: Date: 2025/12/4 Signed by (Printed Name/Title): Arndt von Bieren / Deputy VP of SW&IoT Docusign Envelope ID: F276E5A0-9F63-493C-B149-90A44F0CFF55

Cover Letter(s)

SkyCell AG Protected Authority letter FCC Date: 2025/12/3 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: FCC ID: 2A2SN-SKYCELL814B To whom it may concern: We, the undersigned, hereby authorize SGS-CSTC Standards Technical Services Co., Ltd. (SGS) Guangzhou branch and Bonnie Liao in SGS-CSTC Standards Technical Services Co., Ltd. (SGS) Guangzhou branch to act on our behalf in all manners relating to application for equipment authorization with respect to the FCC ID above, including signing of all documents relating to these matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Where our agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by SGS North America, Inc., still resides with applicant company FCC. This authorization is valid until further written notice from the applicant. Name (Printed): Arndt von Bieren Title: Deputy VP of SW&IoT Signature: On behalf of Company: SkyCell AG Docusign Envelope ID: 6D63A9FE-07E7-49B5-BC2A-ACF8F91D8D94

Cover Letter(s)

SkyCell AG Protected Confidential letter FCC To: SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia United States From: SkyCell AG Bahnhofplatz CH-6300 Zug Switzerland Regarding: Confidentiality Request regarding application for FCC ID: 2A2SN-SKYCELL814B LONG TERM CONFIDENTIALITY Pursuant to 47 CFR Section 0.459 and 0.457 of the commission’s rules, the applicant hereby request confidential treatment of the documents listed below, associated with the certification application referenced above. Schematic(s) Block Diagrams Operational Descriptions The documents above contain proprietary information not released to the public. Public disclosure of this information may prove harmful to the business of the applicant. SHORT TERM CONFIDENTIALITY Additionally, the applicant does NOT request product external photos, internal photos, test setup photos and user manual to be held confidential until the device is marketed or 180 days from the grant date, whichever is less. Sincerely, Name (Printed): Arndt von Bieren Title: Deputy VP of SW&IoT Signature: On behalf of Company: SkyCell AG Docusign Envelope ID: 6D63A9FE-07E7-49B5-BC2A-ACF8F91D8D94

External Photos

SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.1 Page: 1 of 4 Appendix External Photos for GZCR2509001363AT SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.1 Page: 2 of 4 EUT Constructional Details (EUT Photos) SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.1 Page: 3 of 4 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.1 Page: 4 of 4 - End of the Appendix -

Internal Photos

SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 1 of 6 Appendix Internal Photos for GZCR2509001363AT SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 2 of 6 EUT Constructional Details (EUT Photos) SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 3 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 4 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 5 of 6 RF ANT SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 6 of 6 - End of the Appendix -

RF Exposure Info

SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 2.0 Report No.: GZCR250900136303 Page: 1 of 9 FCC ID: 2A2SN-SKYCELL814B RF EXPOSURE EVALUATION REPORT Application No.: GZCR2509001363AT Applicant:SkyCell AG Address of Applicant:Bahnhofplatz, CH-6300 Zug, Switzerland Manufacturer:SkyCell AG Address of Manufacturer:Bahnhofplatz, CH-6300 Zug, Switzerland Factory:Flextronics Manufacturing (ZhuHai) Co.,Ltd Address of Factory:XinQing Science&Technology Industrial Park Jing An Town/Zhuhai Product Name:Wireless Data Logger Model No.: MR814B Trade Mark:SKYCELL Standard(s) : KDB 447498 D01 V06 Date of Receipt: 2025-09-04 Date of Evaluation: 2025-10-13 to 2025-10-13 Date of Issue: 2025-12-11 Evaluation Result: Pass* * In the configuration evaluated, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 2.0 Report No.: GZCR250900136303 Page: 2 of 9 Revision Record VersionReport No.DateRemark 01GZCR2509001363032025-12-11Original Authorized for issue by: Key Liang/Project Engineer Approved By Vico Cui/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 2.0 Report No.: GZCR250900136303 Page: 3 of 9 2Evaluation Summary ItemStandardMethodRequirementResult RF Exposure KDB 447498 D01 V06 KDB 447498 D01 V06KDB 447498 D01 V06Pass Note: E.U.T./EUT means Equipment Under Test. Pass means the test result passed the test standard requirement, please find the detailed decision rule in the report relative section. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 2.0 Report No.: GZCR250900136303 Page: 4 of 9 3Contents Page 1Cover Page...............................................................................................................................................1 2Evaluation Summary................................................................................................................................3 3Contents....................................................................................................................................................4 4General Information.................................................................................................................................5 4.1Details of E.U.T.................................................................................................................................5 4.2Evaluating Location...........................................................................................................................5 4.3Facility...............................................................................................................................................5 4.4Deviation from Standards..................................................................................................................6 4.5Abnormalities from Standard Conditions...........................................................................................6 5Technical Requirements Specification..................................................................................................7 5.1General Description of Applied Standards........................................................................................7 5.2RF Exposure Evaluation....................................................................................................................7 5.2.1Limit & Test Method......................................................................................................................7 5.2.2Conclusion....................................................................................................................................8 6EUT Constructional Details (EUT Photos).............................................................................................9 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 2.0 Report No.: GZCR250900136303 Page: 5 of 9 4General Information 4.1Details of E.U.T. Power supply:DC 15.0V = 5 x 3.0V CR1632 button cell Cable(s):None. RF Character:Please refer to section 4.1 of test report GZCR250900136302 for RF details. Remark: The information in this section is provided by the applicant or manufacturer, SGS is not liable to the accuracy, suitability, reliability or/and integrity of the information. 4.2Evaluating Location All tests were performed at: SGS-CSTC Standards Technical Services Co., Ltd., Guangzhou Branch EMC Laboratory, No.198, Kezhu Road, Science City, Economic & Technological Development Area, Guangzhou, Guangdong, China 510663 Tel: +86 20 82155555 No tests were sub-contracted. 4.3Facility The facility is recognized, certified, or accredited by the following organizations: ● ACMA SGS-CSTC Standards Technical Services Co., Ltd., EMC Laboratory can also perform testing for the Australian/New Zealand Regulatory Compliance Mark (RCM). ● SGS UK(Certificate No.: 32), SGS-TUV SAARLAND and SGS-FIMKO Have approved SGS-CSTC Standards Technical Services Co., Ltd., EMC Laboratory as a supplier of EMC TESTING SERVICES and SAFETY TESTING SERVICES. ● FCC Recognized Accredited Test Firm(Registration No.: 486818) SGS-CSTC Standards Technical Services Co., Ltd., EMC Laboratory has been accredited and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. Designation Number: CN5016, Test Firm Registration Number: 486818. ● ISED (Registration No.: 4620B, CAB identifier: CN0052) SGS-CSTC Standards Technical Services Co., Ltd., has been registered by Innovation Science and Economic Development Canada for Wireless Device Testing laboratories to test to Canadian radio equipment requirements. Registration No. 4620B, CAB identifier: CN0052. ● VCCI (Registration No.: R-12460, C-12584, G-20107 and T-11179) The 10m Semi-anechoic chamber, 966 Anechoic Chamber and Shielded Room of SGS-CSTC Standards Techni…

Text truncated - open the document above for the full version.

Test Report

www.speed-hz.com 苏州硕贝德通讯技术有限公司 SUZHOUSPEEDCOMMUNICATION TECHNOLOGYCO.,LTD. AntennaSpecification Customer Project FlexSkycell-814 Frequency Band 2400~2500MHz, SCTP/N F-0A-2F-0182-001-00 Version T02 Date 2025.12.11 SPEED Checked by RFHaoWu Designed by RFLiyangZhao ME KevinWang ME WestonDong QC Remark ManufacturerHuizhouSpeedWirelessTechnologyCo.,Ltd. Address138HuizeRoad,Hi-TechIndustrialParkofEastRiver, ZhongkaiHi-techDistrict,Huizhou,Guangdong Customer Date Confirmedby RF ME Remark www.speed-hz.com 2 Version ContentDate T01 Firstreleasedversion20251128 T02 AddManufacturerandAddress20251211 www.speed-hz.com 3 Contents 1ProjectOverview.................................................................................4 2AntennaSpecifications.......................................................................4 3AntennaTestEnvironment................................................................5 4MeasuredResults.................................................................................6 4.1ReturnLoss......................................................................................6 4.2Efficiency&PeakGain...................................................................6 5AntennaRadiationPattern(2D&3D)................................................7 6AntennaStructureDiagram..............................................................8 www.speed-hz.com 4 1.ProjectOverview ThisspecificationoutlinesthecharacteristicsoftheantennaforFlexSkycell-814. Theantennaoperatesin2400~2500MHz. Figure1:ProposedAntenna Figure2:MatchingCircuit 2.AntennaSpecifications AntennaTypeStampedMetal OperatingFrequency 2400~2500MHz ReturnLoss <-8.15dB PeakGain0.02~1.15dBi@2400~2500MHz Efficiency -6.84~-5.91dB ImputeImpedance 50ohm PolarizationMode Linear AntennaSizeAsshowninthedrawing ManufactureSPEED www.speed-hz.com 5 3.AntennaTestEnvironment Thetestingequipmentforantennaperformanceparameters,suchasreturnloss, voltagestandingwaveratio,andisolation,istheKeysightE5071Cvectornetwork analyzer.Asshowninthefollowingfigure: Figure3:KeysightE5071CVectorNetworkAnalyzer Theantenna'sefficiency,gain,andradiationpatternweremeasuredinaSatimo anechoicchamber.Thischamberemploys64probestoelectronicallyscanthe antenna’sradiationcharacteristics,collectdata,andprocesstheresults.It supportsantennatestingwithinthefrequencyrangeof400MHzto6GHz . Figure4:SatimoChamberTestingSystem www.speed-hz.com 6 4.MeasuredResults 4.1ReturnLoss Figure5:ReturnLoss 4.2Efficiency&PeakGain FrequencyRange 2400~2500MHz PeakGain 0.02~1.15dBi Efficiency -6.84~-5.91dB (a)AntennaEfficiency www.speed-hz.com 7 (b)PeakGain Figure6:Efficiency&PeakGain 5AntennaRadiationPattern(2D&3D) θ=90° φ=0°φ=90° Figure7:RadiationPattern(2D) 2.4GHz2.45GHz2.5GHz Figure8:RadiationPattern(3D) www.speed-hz.com 8 6AntennaStructureDiagram Figure9:AntennaStructureDiagram

Test Report

SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 2.0 Report No.: GZCR250900136302 Page: 1 of 68 FCC ID: 2A2SN-SKYCELL814B TEST REPORT Application No.: GZCR2509001363AT Applicant: SkyCell AG Address of Applicant: Bahnhofplatz, CH-6300 Zug, Switzerland Manufacturer: SkyCell AG Address of Manufacturer: Bahnhofplatz, CH-6300 Zug, Switzerland Factory: Flextronics Manufacturing (ZhuHai) Co.,Ltd Address of Factory: XinQing Science&Technology Industrial Park Jing An Town/Zhuhai Product Name: Wireless Data Logger Model No.: MR814B Trade Mark: SKYCELL Standard(s) : 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2025-09-04 Date of Test: 2025-09-23 to 2025-11-06 Date of Issue: 2025-12-11 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 2.0 Report No.: GZCR250900136302 Page: 2 of 68 Revision Record Version Report No. Date Remark 01 GZCR250900136302 2025-12-11 Original Authorized for issue by: Key Liang/Project Engineer Approved By Vico Cui/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 2.0 Report No.: GZCR250900136302 Page: 3 of 68 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(b)(4) Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Radiated Emissions which fall in the restricted bands 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2020) Section 11.12 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Below 1GHz ANSI C63.10 (2020) Section 6.4,6.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Above 1GHz ANSI C63.10 (2020) Section 6.6 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass** Conducted Peak Output Power ANSI C63.10 (2020) Section 11.9.1 47 CFR Part 15, Subpart C 15.247(b)(3) Pass Minimum 6dB Bandwidth ANSI C63.10 (2020) Section 11.8.1 47 CFR Part 15, Subpart C 15.247a(2) Pass Power Spectrum Density ANSI C63.10 (2020) Section 11.10.2 47 CFR Part 15, Subpart C 15.247(e) Pass Conducted Band Edges Measurement ANSI C63.10 (2020) Section 6.10.4 47 CFR Part 15, Subpart C 15.247(d) Pass Conducted Spurious Emissions ANSI C63.10 (2020) Section 11.11 47 CFR Part 15, Subpart C 15.247(d) Pass **: The EUT passed Radiated Spurious Emissions Above 1GHz test after modifications. Note: E.U.T./EUT means Equipment Under Test. Pass means the test result passed the test standard requirement, please find the detailed decision rule in the report relative section. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 2.0 Report No.: GZCR250900136302 Page: 4 of 68 3 Contents Page 1 Cover Page ........................................................................................................................................... 1 2 Test Summary ....................................................................................................................................... 3 3 Contents ............................................................................................................................................... 4 4 General Information.............................................................................................................................. 6 4.1 Details of E.U.T. ............................................................................................................................. 6 4.2 Description of Support Units ........................................................................................................... 6 4.3 Measurement Uncertainty .............................................................................................................. 7 4.4 Test Location ................................................................................................................................. 7 4.5 Test Facility .................................................................................................................................... 8 4.6 Deviation from Standards ..............................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Arndt von Bieren(Deputy VP of SW&IoT)
[email protected]Fax: 0041445376734

Technical Contact

SGS-CSTC Standards Technical Services Co., LtdBonnie Liao
[email protected]

No.198 Kezhu Road, Science City Economic & · Guangzhou, Guangdong, 510663 · China

Test Firm

SGS-CSTC Standards Technical Services Co., Ltd.Bonnie Liao
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.70 mW
215C2.40 GHz - 2.48 GHz6.60 mW
Confidentiality
Long Term
Grant Notes
Power Output listed is conducted.

Other Applications from SkyCell AG

2A2SN-SKYCELL900

MR Gateway

Sep 12, 2024

Equipment Class

DTS - Digital Transmission System