Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Feb 27, 2023
Application Purpose
Original Equipment
Date of Application
Jan 24, 2023
Equipment Note
Wireless transmitter with data measurement capability
Frequency Range
2402.00000000 - 2480.00000000
Company
EDGE TECHNOLOGIES
Country
France

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗
↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

VALVE POSITION INSTRUCTION MANUAL (613-00001) SENSA.VALV Disclaimer SENSA.iO is a brand of © 2022 EDGE TECHNOLOGIES SAS. All Rights Reserved. The trademarks, logos, and service marks (“Marks”) included herein are the property of EDGE TECHNOLOGIES SAS or of their respective owners. Use of any Mark is not permitted without the prior written consent of EDGE TECHNOLOGIES SAS or of the respective owner. The information in this document is subject to change without notice. EDGE TECHNOLOGIES SAS and/or its representatives cannot be held responsible for any errors or inaccuracies within this document. SENSAIO Intelligent Connected Wireless Sensors For Hazardous environments CONFIDENTIAL SENSA.iO Intelligent Connected Wireless Sensors For Hazardous Environments LoRaWAN Valve position Sensors User Manual | English 613-00001 Page 1 of 53 Revisions Page No. Context Version Date All First Release DRAFT 01/02/2021 All Second Update Rev.1.1 21/07/2021 #21, #15 Payload decoding, Grounding Rev.1.2 16/09/2021 All Third Update Rev.2 11/09/2022 Further information Additional documentation on SENSA.iO LoRaWAN Valve position is available for download free of charge at https://sensa.io/wireless-valve position-transmitter/ or alternatively, scan this code: Manufacturer EDGE TECHNOLOGIES SAS 735 Rue du Lieutenant Parayre 13290 AIX-EN-PROVENCE France Tel : +33 (0)4 84 39 08 82 Customer service center https://sensaio.zohodesk.com [email protected] LoRaWAN Valve position Sensors User Manual | English 613-00001 Page 2 of 53 Contents 1 Safety information ............................................................................................................. 3 1.1 Intended use .............................................................................................................. 4 1.2 Handling of lithium-ion batteries ............................................................................... 4 1.3 Transportation ........................................................................................................... 5 1.4 Packaging ................................................................................................................... 5 1.5 Warranty provisions .................................................................................................. 5 1.6 Storage ....................................................................................................................... 5 1.7 Environmental conditions .......................................................................................... 6 1.8 Radio Waves .............................................................................................................. 6 2 General Product information ............................................................................................. 7 2.1 Product description ................................................................................................... 7 2.2 Product specifications ............................................................................................... 8 3 Installation of the sensor .................................................................................................. 10 3.1 Replacing the battery .............................................................................................. 12 3.2 Sealing procedure .................................................................................................... 15 3.3 Operate the device .................................................................................................. 16 3.4 Battery life ............................................................................................................... 17 3.5 Installation of Valve position Sensor ....................................................................... 18 3.6 Grounding ................................................................................................................ 19 3.7 Serial Number .......................................................................................................... 20 4 App and Device ................................................................................................................ 21 4.1 Sensalink Mobile ...................................................................................................... 21 4.2 Sensalink Web ......................................................................................................... 30 5 LoRawan Payload ............................................................................................................. 35 5.1 LoRaWAN Regional parameters .............................................................................. 35 5.2 Data formatting ....................................................................................................... 36 6 Spare parts ....................................................................................................................... 44 7 Certifications and approvals ............................................................................................. 45 7.1 Equipment marking ................................................................................................. 45 7.2 Installation, maintenance and repair ....................................................................... 48 7.3 Specific Conditions of Use ....................................................................................... 48 7.4 Availability of instructions ....................................................................................... 48 7.5 Regulatory Compliance Statements ........................................................................ 49 8 Technical Battery data ...................................................................................................... 52 9 Ordering number .............................................................................................................. 53 LoRaWAN Valve position Sensors User Manual…

Text truncated - open the document above for the full version.

Attestation Statements

SAS au capital de 60 000 € – SIRET 85214374200017 – APE 7112B – TVA FR21852143742 735 Rue du lieutenant Parayre 13290 Aix-en-Provence Tel. 04 42 61 66 00 – E-mail: [email protected] – url : www.edgetech.fr Aix-en-Provence, on January 15th, 2023 Subject: Pre-Approval Guidance of SENSAiO Applicant: EDGE TECHNOLOGIES SAS Product (PMN): SENSAiO Model (HVIN): SENSA915A Host (HMN) : SENSA.VALV FCC ID: 2A2T5-SENSA915A IC ID: 29177-SENSA915A To whom it may concern: The SENSAiO product is an electronic device consisting of two electronic modules with a force feedback system and a push-in coupling system for mechanical and electrical coupling, supporting a mother electronic assembly called the "electronic cartridge" with a removable D-Cell battery and a suitable integrated antenna. The electronics cartridge can only be connected to the SENSAiO base sensor module with dedicated daughter connectors with interlocking mechanism. Due to the patented interlocking design, it is impossible to access the electronics without modifying the module. This module is only intended for and can only be incorporated into SENSA.XXXX type products manufactured by EDGE TECHNOLOGIES, which will be subject to Class 2 permissive change procedures for future models (e.g. SENSA.PRES and SENSA.TEMP). This module cannot be sold separately. Please refer to user instruction for further information. If you have any questions, please do not hesitate to contact us. Regards, Thomas GUILLET

Attestation Statements

Aix-en-Provence, on January 24th, 2022 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Subject: Attestation Statements Part 2.911(d)(5)(i) Filing Applicant: EDGE TECHNOLOGIES SAS FCC ID: 2A2T5-SENSA915A EDGE TECHNOLOGIES SAS (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Thomas GUILLET

Attestation Statements

Aix-en-Provence, on January 24th, 2022 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Subject: Attestation Statements Part 2.911(d)(5)(ii) Filing Applicant: EDGE TECHNOLOGIES SAS FCC ID: 2A2T5-SENSA915A EDGE TECHNOLOGIES SAS (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Thomas GUILLET

Attestation Statements

EDGE TECHNOLOGIES 735 AVENUE DU LIEUTENANT PARAYRE 13290 AIX EN PROVENCE FRANCE Aix-en-Provence, on February 23 rd , 2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA FCC ID: 2A2T5-SENSA915A Subject: US Agent - Attestation Statements Part 2.911(d)(7) Filing Applicant: EDGE TECHNOLOGIES SAS Service Type: Original Application Modular Approval Type: Limited Modular Host Marketing Name: SENSA.VALV EDGE TECHNOLOGIES certifies, that as of February 23rd, 2023, we have designated FCC US Agent, LLC to accept service of process on our behalf for FCC ID: 2A2T5-SENSA915A. EDGE TECHNOLOGIES, accepts to maintain an agent of service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. FCC US Agent, LLC, accepts as of the date of the filing of this application, the obligation of being the designated agent for the purpose of accepting service of process on behalf of EDGE TECHNOLOGIES for FCC ID: 2A2T5-SENSA915A. Designated U.S. Agent Information: Company Name: FCC US Agent, LLC FRN: 0033402884 Address: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA Contact Person: Tim Payne Phone: 708-571-3148 Email: [email protected] Sincerely, Company EDGE TECHNOLOGIES SAS Designated Agent: FCC US AGENT, LLC Company Representative Thomas GUILLET Designated Agent Representative: Tim PAYNE

Cover Letter(s)

SAS au capital de 60 000 € – SIRET 85214374200017 – APE 7112B – TVA FR21852143742 735 Rue du lieutenant Parayre 13290 Aix-en-Provence Tel. 04 42 61 66 00 – E-mail: [email protected] – url : www.edgetech.fr Subject.: Acknowledgment of FCC Modular approval requirements FCC ID : 2A2T5-SENSA915A To Whom It May Concern: LoRaWAN Valve Positioning Sensor an intelligent industrial wireless sensor for remote monitoring in hazardous environments. Modular Approval Requirement Yes No (i) The radio elements of the modular transmitter must have their own shielding. The physical crystal and tuning capacitors may be located external to the shielded radio elements. Yes (ii) The modular transmitter must have buffered modulation/data inputs (if such inputs are provided) to ensure that the module will comply with part 15 requirements under conditions of excessive data rates or over- modulation. Yes (iii) The modular transmitter must have its own power supply regulation. Yes (iv) The modular transmitter must comply with the antenna and transmission system requirements of §§ 15.203, 15.204(b) and 15.204(c). The antenna must either be permanently attached or employ a ‘‘unique’’ antenna coupler (at all connections between the module and the antenna, including the cable). The ‘‘professional installation’’ provision of § 15.203 is not applicable to modules but can apply to limited modular approvals under paragraph (b) of this section. Yes (v) The modular transmitter must be tested in a stand-alone configuration No (vi) The modular transmitter must be equipped with either a permanently affixed label or must be capable of electronically displaying its FCC identification number. Yes (vii) The modular transmitter must comply with any specific rules or operating requirements that ordinarily apply to a complete transmitter and the manufacturer must provide adequate instructions along with the module to explain any such requirements. A copy of these instructions must be included in the application for equipment authorization. Yes (viii) The modular transmitter must comply with any applicable RF exposure requirements in its final configuration. Yes (v) The modular transmitter is always tested on a mainboard in a specific EDGE TECHNOLOGIES configuration (into a host device) Zoho Sign Document ID: 292CDBFE-XGNUC2SNLCGDEFQWBYZNC2HDEAVBYXCKW8WYGCBYKQG

Cover Letter(s)

SAS au capital de 60 000 € – SIRET 85214374200017 – APE 7112B – TVA FR21852143742 735 Rue du lieutenant Parayre 13290 Aix-en-Provence Tel. 04 42 61 66 00 – E-mail: [email protected] – url : www.edgetech.fr Aix-en-Provence, on January 24th, 2022 Subject: RADIO Certification of SENSAiO Applicant: EDGE TECHNOLOGIES SAS Product (PMN): SENSAiO Model (HVIN): SENSA915A Host (HMN) : SENSA.VALV FCC ID: 2A2T5-SENSA915A IC ID: 29177-SENSA915A To Whom It May Concern: We would like to submit the above product for Certification concerning FCC and ISED rules for a new single certification in limited modular approval. Please review all required documents enclosed. This application is a wireless transmitter with data measurement capability. It is composed of 2 elements: - Electronic cartridge with radio chipset and embedded antenna which is the subject of modular approval certification - Deported sensor board for process measurement and a housing incorporating the radio and these sensor board Compliance for RF exposure requirement is demonstrated in test report. If you have any queries, please do not hesitate to contact us. Regards, Thomas GUILLET

Cover Letter(s)

Federal Communicaons Commission Authorizaon and Evaluaon Division Aix-en-Provence, on December 18th, 2022 Subject: Confidenality Request regarding applicaon for cerficaon of FCC ID: 2A2T5-SENSA915A Applicant: EDGE TECHNOLOGIES SAS Product: SENSAiO Model: SENSA915A To Whom It May Concern: Pursuant to Secons 0.457 and 0.459 of the Commission’s Rules, we hereby request confidenal treatment of informaon accompanying this applicaon as outlined below: Exhibit Type File Name Block Diagram Schemacs Operaonal Descripon Parts List SENSA915A BlkDia.pdf” SENSA915A Schem.pdf” SENSA915A Opdes.pdf” SENSA915A PartsLst.pdf The above materials contain trade secrets and proprietary informaon not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjusfied benefits to its competors. The applicant understands that pursuant to Secon 0.457 of the Rules, disclosure of this applicaon and all accompanying documentaon will not be made before the date of the Grant for this applicaon. If you have any queries, please do not hesitate to contact us. Regards, [Nom, Date et SIGNATURE] SAS au capital de 60 000 € – SIRET 85214374200017 – APE 7112B – TVA FR21852143742 735 Rue du lieutenant P arayre 13290 Aix-en-Provence Tel. 04 42 61 66 00 – E-mail: [email protected] – url : www.edgetech.fr Zoho Sign Document ID: 292CDBFE-T4JYEQST-ZZZOOKU89MIXDTFCGQYDTLKI7T0CJ_5OBM

Cover Letter(s)

Aix-en-Provence, on December 18th, 2022 An: TIMCO Engineering Inc. 849 N.W. State Road 45 P.O. Box 370 Newberry, Florida 32669 Authority to Act as Agent On our behalf, I appoint M. Olivier HEYER from Emitech Montpellier – 145 rue du Massacan – 34741 VENDARGUES CEDEX FRANCE, to act as our agent in the preparaon of this applicaon for equipment cerficaon. I cerfy that submied documents properly describe the device or system for which equipment cerficaon is sought. I also cerfy that each unit manufactured, imported or marketed, as defined in the Federal Communicaons Commission’s regulaons will have affixed to it a label idencal to that submied for approval with this applicaon. For instances where our authorized agent signs the applicaon for cerficaon on our behalf, I acknowledge that all responsibility for complying with the terms and condions for cerficaon, as specified by TIMCO Engineering Inc., sll resides with EDGE TECHNOLOGIES, 735 Rue du Lieutenant Parayre, 13290 Aix-En-Provence. This authorizaon is valid unl further wrien noce from EDGE TECHNOLOGIES. [Nom, Date et SIGNATURE] SAS au capital de 60 000 € – SIRET 85214374200017 – APE 7112B – TVA FR21852143742 735 Rue du lieutenant P arayre 13290 Aix-en-Provence Tel. 04 42 61 66 00 – E-mail: [email protected] – url : www.edgetech.fr Zoho Sign Document ID: 292CDBFE-CUPI1DMFTHON3UXKQHT2Q_TWNXYV8D_KX2M7JA6C45K

External Photos

SENSAiOValve position –Sideview1 Modelshown:SENSA.VALV-IMU-1-1-1-L-1-1-N SENSAiOValve position –Sideview2 Modelshown:SENSA.VALV-IMU-1-1-1-L-1-1-N SENSAiOValve position –Top view Modelshown:SENSA.VALV-IMU-1-1-1-L-1-1-N SENSAiOValve position –Bottom view Modelshown:SENSA.VALV-IMU-1-1-1-L-1-1-N SENSAiOValve position –Perspective view Modelshown:SENSA.VALV-IMU-1-1-1-L-1-1-N

ID Label/Location Info

Model: SENSAiO Doc. No.: FCCIC-SENSA915A Date: 8 Dec, 2022 3/3 Label Sample PMN: SENSAiO HVIN : SENSA915A Model: SENSAiO Doc. No.: FCCIC-SENSA915A Date: 8 Dec, 2022 3/3 1. Label design Sub Cartridge module Figure1. Label design 2. Label photo Sub Cartridge module Figure2. Label photo FCC ID :2A2T5-SENSA915A IC : 29177-SENSA915A Model: SENSAiO Doc. No.: FCCIC-SENSA915A Date: 8 Dec, 2022 3/3 3. HMN marking design: SENSA.VALV

ID Label/Location Info

Model: SENSAiO Doc. No.: FCCIC-SENSA915A Date: 8 Dec, 2022 3/3 Label Location PMN: SENSAiO HVIN : SENSA915A Model: SENSAiO Doc. No.: FCCIC-SENSA915A Date: 8 Dec, 2022 3/3 1. Label location Sub Cartridge module Figure3. Label location FCC ID :2A2T5-SENSA915A IC : 29177-SENSA915A Location Model: SENSAiO Doc. No.: FCCIC-SENSA915A Date: 8 Dec, 2022 3/3 2. HMN marking Location Product Labeling

Internal Photos

SENSAiOMainBoard–Top view RF shield SENSAiOMainBoard–Top view RF Parts SENSAiOMainBoard–3D Top view SENSAiOMainBoard–Bottom view SENSAiOMainBoard–3D Bottom view SENSAiOSensorBoardValve position –Top view SENSAiOSensorBoardValve position –Bottom view SENSAiOAntenna–Top view SENSAiOAntenna–Bottom view SENSAiOCartridge –Assemblyview Antenna MainBoard MainBoard RF Parts SENSAiO–Cartridge to SensorBoardconnection SENSAiO–Assemblyview Nutring Cartridge Cartridge cap Process connection (valve position)

RF Exposure Info

Siège Social : Emitech - 3, avenue des Coudriers - Z.A. de l’Observatoire - 78180 MONTIGNY LE BX - France Siret : 344 545 645 00022 - Tél. : 33 (0)1 30 57 55 55 - Fax : 33 (0)1 30 43 74 48 - E-mail : [email protected] - URL : www.emitech.fr SAS au capital de 1 560 000 € - R.C.S. VERSAILLES 344 545 645 - APE 7112B RR-EVE-21C250-1A Ed.0 Duplication of this test report is only permitted for an integral photographic facsimile. It includes the number of pages referenced here above. This document is the result of testing a specimen or a sample of the product submitted. It does not imply an assessment of the conformity of the whole manufactured products of the tested sample. LIST OF ACCREDITED SITES AND SCOPE AVALAIBLE ON WWW.COFRAC.FR TESTING ACCREDITATIONS N° 1-0826, 1-0827, 1- 1925, 1-2069,1-2070, 1-2206, 1-2376 & 1-6086 Test report issued under the responsibility of: EMITECH MONTPELLIER laboratory MRA US-EU Designation Number: FR0006 Canadian CAB Identifier: FR0003 RADIO TEST REPORT FCC 47 CFR Part 15: February 2021 FCC 47 CFR Part 15.247 RSS-247 Issue 2: February 2017 Company ....................................... : EDGE TECHNOLOGIES Address. .......................................... : 735 AVENUE DU LIEUTENANT PARAYRE 13290 AIX EN PROVENCE FRANCE Test item description. .................. : Valve position including wireless transmitter with data measurement capability Trade Mark. .................................... : EDGE TECHNOLOGIES Manufacturer................................... : EDGE TECHNOLOGIES SAS Model/Type reference. .................... : SENSA915A / SENSA.VALV including SENSAIO FCC ID ............................................ : 2A2T5-SENSA915A IC. ................................................... : 29177-SENSA915A Ratings. ........................................... : 2.4Vdc to 3.7Vdc Testing Laboratory ....................... : EMITECH MONTPELLIER laboratory Address. .......................................... : 145 rue de Massacan 34740 VENDARGUES FRANCE Report Reference No. ................... : RR-EVE-21C250-1A Test procedure. .............................. : FCC IC Certification Diffusion. ......................................... : Mr LEVEQUE Applicant’s name. ........................... : EDGE TECHNOLOGIES SAS Date of issue. .................................. : January 26, 2023 Total number of pages. ................... : 52 Revision. ......................................... : 0 Compiled by. ................................... : Morgan PATEY Approved by (+ signature). ............. : Olivier HEYER (Laboratory Manager) RR-EVE-21C250-1A Ed.0 Page 2 on 52 REPORT INDEX: 1. GENERAL INFORMATIONS .......................................................................................................................... 3 2. REFERENCE DOCUMENT(S) ........................................................................................................................ 4 3. EQUIPMENT TECHNICAL DESCRIPTION .................................................................................................... 5 3.1. TEST CONDITIONS ................................................................................................................................... 5 3.2. EUT MARKING PLATE .............................................................................................................................. 5 3.3. EUT GENERAL VIEW ................................................................................................................................ 5 3.4. EUT MECHANICAL AND ELECTRICAL DESIGN ............................................................................................. 6 3.5. EUT INPUT/OUTPUT PORTS ...................................................................................................................... 6 3.6. EUT RADIO SPECIFICATIONS .................................................................................................................... 7 4. RESULT SUMMARY ....................................................................................................................................... 8 5. MEASUREMENT UNCERTAINTY ................................................................................................................10 6. RF EXPOSURE .............................................................................................................................................10 7. TEST CONDITIONS AND RESULTS ...........................................................................................................11 7.1. OCCUPIED BANDWIDTH & 6 DB BANDWIDTH ............................................................................................11 7.2. EQUIVALENT ISOTROPIC RADIATED POWER ..............................................................................................18 7.3. POWER SPECTRAL DENSITY ....................................................................................................................24 7.4. BAND-EDGE COMPLIANCE .......................................................................................................................28 7.5. RADIATED SPURIOUS EMISSIONS .............................................................................................................32 REVISION HISTORY: Revision Date Modified pages Modifications 0 January 26, 2023 / Creation RR-EVE-21C250-1A Ed.0 Page 3 on 52 1. GENERAL INFORMATIONS This document submits the results of Radio tests performed on the equipment Valve position SENSA.VALV (denominated hereafter E.U.T.: equipment under test) according to document(s) listed in §2 of this test report. TESTING PROCEDURE AND TESTING LOCATION: Testing Location ....................................... : EMITECH MONTPELLIER laboratory Address. ..................................................... : 145 rue de Massacan 34740 VENDARGUES FRANCE Test procedure. .......................................... : FCC IC Certification Tested by ........................…

Text truncated - open the document above for the full version.

Test Report

A A B B C C D D E E F F 11 22 33 44 Drill Drawing View (Scale 4:1) SymbolCount 2 2 Total Hole Size 0.52mm Plated Plated Hole Tolerance Drill Table Ø33.00mm SensaIO Pte Ltd 160 Robinson Road #14-04 Singapore 068914 Title : Project Name : Document Number : Revision : Sheet : of Title : Date : Sign : DRAWN BYDRAWN BY : Sign : Date : Title : DRAWN BY : Sign : Date : Title : CHECKED BY QUALITY APPROVED BY 4 1 Rev. A 610-00046 Electronic manufacturing drawings 868MHz Drill drawing SensaIO Antenna 868MHz Rev. A Associated Part Numbers Schematic : 614-00004 PCB : 230-00003 Gerbers : 610-00046 BOM : 910-00004 A A B B C C D D E E F F 11 22 33 44 MaterialLayerThicknessDielectric MaterialTypeGerber Top OverlayLegendGTO Surface MaterialTop Solder0.03mmSolder ResistSolder MaskGTS CopperTop Layer0.04mmSignalGTL 0.76mmDielectricDielectric CopperBottom Layer0.04mmSignalGBL Surface MaterialBottom Solder0.03mmSolder ResistSolder MaskGBS Bottom OverlayLegendGBO Total thickness: 0.89mm Layer Stack Legend SensaIO Pte Ltd 160 Robinson Road #14-04 Singapore 068914 Title : Project Name : Document Number : Revision : Sheet : of Title : Date : Sign : DRAWN BYDRAWN BY : Sign : Date : Title : DRAWN BY : Sign : Date : Title : CHECKED BY QUALITY APPROVED BY Stackup Electronic manufacturing drawings 868MHz 610-00046 Rev. A 4 2 A A B B C C D D E E F F 11 22 33 44 Top Layer (Scale 4:1) Bottom Layer (Scale 4:1) This is an example layout, and the copper artwork may be modified in production for different frequencies. Nevertheless board outline will be maintained, separation from the antenna and other conductive parts will be maintained, and no components will be added. Antenna Max Gain : 3dBi SensaIO Pte Ltd 160 Robinson Road #14-04 Singapore 068914 Title : Project Name : Document Number : Revision : Sheet : of Title : Date : Sign : DRAWN BYDRAWN BY : Sign : Date : Title : DRAWN BY : Sign : Date : Title : CHECKED BY QUALITY APPROVED BY Artworks Electronic manufacturing drawings 868MHz 610-00046 Rev. A 4 3 A A B B C C D D E E F F 11 22 33 44 Realistic ViewRealistic View This is an example layout, and the copper artwork may be modified in production for different frequencies. Nevertheless board outline will be maintained, separation from the antenna and other conductive parts will be maintained, and no components will be added. SensaIO Pte Ltd 160 Robinson Road #14-04 Singapore 068914 Title : Project Name : Document Number : Revision : Sheet : of Title : Date : Sign : DRAWN BYDRAWN BY : Sign : Date : Title : DRAWN BY : Sign : Date : Title : CHECKED BY QUALITY APPROVED BY Realistic view Electronic manufacturing drawings 868MHz 610-00046 Rev. A 4 4

Test Report

Siège Social : Emitech - 3, avenue des Coudriers - Z.A. de l’Observatoire - 78180 MONTIGNY LE BX - France Siret : 344 545 645 00022 - Tél. : 33 (0)1 30 57 55 55 - Fax : 33 (0)1 30 43 74 48 - E-mail : [email protected] - URL : www.emitech.fr SAS au capital de 1 560 000 € - R.C.S. VERSAILLES 344 545 645 - APE 7112B RR-EVE-21C250-1A Ed.0 Duplication of this test report is only permitted for an integral photographic facsimile. It includes the number of pages referenced here above. This document is the result of testing a specimen or a sample of the product submitted. It does not imply an assessment of the conformity of the whole manufactured products of the tested sample. LIST OF ACCREDITED SITES AND SCOPE AVALAIBLE ON WWW.COFRAC.FR TESTING ACCREDITATIONS N° 1-0826, 1-0827, 1- 1925, 1-2069,1-2070, 1-2206, 1-2376 & 1-6086 Test report issued under the responsibility of: EMITECH MONTPELLIER laboratory MRA US-EU Designation Number: FR0006 Canadian CAB Identifier: FR0003 RADIO TEST REPORT FCC 47 CFR Part 15: February 2021 FCC 47 CFR Part 15.247 RSS-247 Issue 2: February 2017 Company ....................................... : EDGE TECHNOLOGIES Address. .......................................... : 735 AVENUE DU LIEUTENANT PARAYRE 13290 AIX EN PROVENCE FRANCE Test item description. .................. : Valve position including wireless transmitter with data measurement capability Trade Mark. .................................... : EDGE TECHNOLOGIES Manufacturer................................... : EDGE TECHNOLOGIES SAS Model/Type reference. .................... : SENSA915A / SENSA.VALV including SENSAIO FCC ID ............................................ : 2A2T5-SENSA915A IC. ................................................... : 29177-SENSA915A Ratings. ........................................... : 2.4Vdc to 3.7Vdc Testing Laboratory ....................... : EMITECH MONTPELLIER laboratory Address. .......................................... : 145 rue de Massacan 34740 VENDARGUES FRANCE Report Reference No. ................... : RR-EVE-21C250-1A Test procedure. .............................. : FCC IC Certification Diffusion. ......................................... : Mr LEVEQUE Applicant’s name. ........................... : EDGE TECHNOLOGIES SAS Date of issue. .................................. : January 26, 2023 Total number of pages. ................... : 52 Revision. ......................................... : 0 Compiled by. ................................... : Morgan PATEY Approved by (+ signature). ............. : Olivier HEYER (Laboratory Manager) RR-EVE-21C250-1A Ed.0 Page 2 on 52 REPORT INDEX: 1. GENERAL INFORMATIONS .......................................................................................................................... 3 2. REFERENCE DOCUMENT(S) ........................................................................................................................ 4 3. EQUIPMENT TECHNICAL DESCRIPTION .................................................................................................... 5 3.1. TEST CONDITIONS ........................................................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Thomas GUILLET(CEO)
[email protected]+33606476218Fax: +33606476218

Test Firm

EMITECH MontpellierOlivier HEYER
[email protected]33-4-67-871102Fax: 33-4-67-709455

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz100.00 µW
Modular Type
Limited Single Modular Approval
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. Limited Single Modular Approval for mobile RF Exposure condition. This module is limited to integration into Edge Technologies SENSA sensor devices. These sensors must be installed to meet the RF exposure compliance separation distance of 20 cm, and any additional testing and authorization process as required. Co-location of this module with other transmitters that operate simultaneously are required to be evaluated using the FCC multi-transmitter procedures. The grantee must provide end-users with installation and operating instructions for satisfying FCC multi-transmitter product guidelines.