FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Inateck Technology Co., Ltd./
  3. 2A2T9-N0073

2A2T9-N0073Keyboard

Shenzhen Inateck Technology Co., Ltd.
Keyboard - FCC ID 2A2T9-N0073 - Shenzhen Inateck Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 26, 2026
Application Purpose
Original Equipment
Equipment Note
Keyboard
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Inateck Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗
↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

English · Deutsch·日本語·Français·中文 NeoMagic Keyboard N0073/N0074 User Manual 深圳市理诚科技有限公司 广东省深圳市龙岗区坂田街道天安云谷2期11栋2507 电话:0755-23484029 中国制造 Europe F&M Technology GmbH Tel: +49 341 5199 8410 (Working day 8 AM - 4 PM CET) Fax: +49 341 5199 8413 Address: Fraunhoferstraße 7, 04178 Leipzig, Deutschland NorthAmerica Inateck Technology Inc. Tel: +1 (909) 698 7018 (Working day 9 AM - 5 PM PST) Address: 2078 Francis St., Unit 14-02, Ontario, CA 91761, USA 日本 Inateck株式会社 電話番号:+81 06 7500 3304 〒547-0014 大阪府大阪市平野区長吉川辺3丁目10番11号 Manufacturer Shenzhen Inateck Technology Co., Ltd. Address: Suite 2507, Block 11 in Tian An Cloud Park, Bantian Street, Longgang District, Shenzhen, Guangdong, China Email: [email protected] Postal code: 518129 ServiceCenter F&MTechnologyGmbH Fraunhoferstraße 7, 04178 Leipzig, Deutschland Tel: +49 341 5199 8410 Email: [email protected] Postal code: 04178 InateckTechnology(UK)Ltd. 95 High Street, Office B, Great Missenden, United Kingdom, HP16 0AL Tel: +44 20 3239 9869 For Product and Battery inateck Origin App Download Download the inateck Origin App by scanning the QR code or searching for “inateck Origin” in the App Store. With this app, you can easily configure the keyboard functions. If you have any questions, feel free to contact inateck customer service. Herunterladen der inateck Origin App Laden Sie die inateck Origin App herunter, indem Sie den QR-Code scannen oder im App Store nach „inateck Origin“ suchen. Mit dieser App können Sie die Tastaturfunktionen ganz einfach konfigurieren. Wenn Sie Fragen haben, können Sie sich gerne an den inateck-Kundendienst wenden. inateck Origin アプリ機能紹介 QRコードをスキャンするか、App Store で「inateck Origin」を検索してアプリ をダウンロードしてください。このアプリを使用すると、キーボードの機能を簡 単に設定できます。 ご不明な点がございましたら、いつでも inateck カスタマーサービスにお問い合 わせください。 Présentation de l’application inateck Origin Téléchargez l’application inateck Origin en scannant le code QR ou en recherchant « inateck Origin » sur l’App Store. Cette application vous permet de configurer facilement les fonctions de votre clavier. Pour toute question, n’hésitez pas à contacter le service client d’inateck à tout moment. inateck Origin App功能介绍 通过扫描二维码或在App Store搜索“inateck Origin”下载inateck Origin应用 程序。使用该app,您可以轻松进行对键盘进行功能配置。 如有任何问题,欢迎随时联系inateck客服。

Users Manual

说明书尺寸:骑马钉120*180mm 材质:100g双胶纸 此页不做印刷

Attestation Statements

Covered Equipment Attestation Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2A2T9-N0073 N0073, N0074, N0075, N0076, N0077, N0078, N0079, N0080, N0081 We, Applicant Company Name: Shenzhen Inateck Technology Co., Ltd. Address: Rm. 2507, Bldg. 11, TianAn Cloud Park, Bantian Street, Longgang District, Shenzhen, China Phone: +86-755-23484029 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. This includes the cybersecurity and anti-virus software produced or provided by Kaspersky Lab, Inc. or any of ist successors and assignees. We certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2025-12-05 Signature Date Name / Title: Fret Huang / Product Manager Company: Shenzhen Inateck Technology Co., Ltd. Address: Rm. 2507, Bldg. 11, TianAn Cloud Park, Bantian Street, Longgang District, Shenzhen, China Phone: +86-755-23484029 Fax: N/A E-Mail: [email protected]

Attestation Statements

Due Diligence Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern FCC ID Model name 2A2T9-N0073 N0073, N0074, N0075, N0076, N0077, N0078, N0079, N0080, N0081 Pursuant to KDB 986446 D01 Covered Equipment Guidance the evaluation of the product above shows compliance for the following reasons: Compliance Evaluation process Results Inherent compliance The chipset(s) used is not capable of running the cybersecurity and/or anti-virus software Compliance The memory used does not allow the running the cybersecurity and/or anti-virus software Compliance The storage capacity does not allow the running the cybersecurity and/or anti-virus software Compliance The operating system used is not capable of running the cybersecurity and/or anti-virus software Compliance No inherent compliance Based on software bill of material Based on scan for running software on the device Based on filesystem scan for cybersecurity and/or anti-virus software The equipment for which authorization is sought complies with the rules and fulfils the requirements as detailed in the above mentioned KDB. Evaluation performed by Company Name: Shenzhen Huaxia Testing Technology Co., Ltd Contact Name: Yoyo Zhou Address: 1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua District, Shenzhen, China Phone: +86-755-26648642 Email: [email protected] Signature: Date: 2026-01-21

Cover Letter(s)

Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2A2T9-N0073 N0073, N0074, N0075, N0076, N0077, N0078, N0079, N0080, N0081 For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Part List • the Tune up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2025-12-05 Signature Date Name / Title: Fret Huang / Product Manager Company: Shenzhen Inateck Technology Co., Ltd. Address: Rm. 2507, Bldg. 11, TianAn Cloud Park, Bantian Street, Longgang District, Shenzhen, China Phone: +86-755-23484029 Fax: N/A E-Mail: [email protected]

Cover Letter(s)

ShenzhenInateckTechnologyCo.,Ltd. ModelConfirmationLetter We,ShenzhenInateckTechnologyCo.,Ltd.certifytheproduct: Keyboard ModelNo.: N0073,N0074,N0075,N0076,N0077,N0078,N0079,N0080,N0081 FCCID:2A2T9-N0073 Theirelectricalcircuitdesign,layout,componentsusedandinternalwiringareidentical, Onlythemodelnumberisdifferent. Signiture: GranteeContact:FretHuang CompanyName:ShenzhenInateckTechnologyCo.,Ltd. Date:December5,2025

External Photos

Externalphotos FCC ID: 2A2T9-N0073

Internal Photos

Internalphotos ANT FCC ID: 2A2T9-N0073

RF Exposure Info

ShenzhenHuaxiaTestingTechnologyCo.,Ltd 1F.,BlockAofTongshengTechnologyBuilding,HuahuiRoad,DalangStreet,LonghuaDistrict, Shenzhen,China Telephone:+86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com ReportTemplateVersion:V05 ReportTemplateRevisionDate:2021-11-03 RFExposureEvaluationReport Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthisreportreferonlyto thesample(s)tested.WithoutwrittenapprovalofCQA,thisreportcan’tbereproducedexceptinfull. ReportNo.:CQASZ20251102731E-02 Applicant:ShenzhenInateckTechnologyCo.,Ltd. AddressofApplicant:Rm.2507,Bldg.11,TianAnCloudPark,BantianStreet,LonggangDistrict, Shenzhen,China. EquipmentUnderTest(EUT): EUTName:Keyboard ModelNo.:N0073,N0074,N0075,N0076,N0077,N0078,N0079,N0080,N0081 TestModelNo.:N0073 BrandName:inateck FCCID:2A2T9-N0073 Standards: 47CFRPart1.1307 47CFRPart2.1093 KDB447498D04InterimGeneralRFExposureGuidancev01 DateofReceipt:2025-11-26 DateofTest: 2025-11-26to2026-01-05 DateofIssue:2026-01-21 TestResult:PASS* *Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove. TestedBy: (LewisZhou) ReviewedBy: (TimoLei) ApprovedBy: (JackAi) ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20251102731E-02 Page:2of7 1Version RevisionHistoryOfReport ReportNo.Version Description IssueDate CQASZ20251102731E-02Rev.01 Initialreport 2026-01-21 ModelNo.:N0073,N0074,N0075,N0076,N0077,N0078,N0079,N0080,N0081. Theirelectricalcircuitdesign,layout,componentsusedandinternalwiringareidentical, Onlythemodelisdifferent. ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20251102731E-02 Page:3of7 2Contents Page 1VERSION............................................................................................................................................................................2 2CONTENTS........................................................................................................................................................................3 ..................................................................................................................................................................................................3 3GENERALINFORMATION..............................................................................................................................................4 3.1CLIENTINFORMATION...................................................................................................................................................4 3.2GENERALDESCRIPTIONOFEUT...................................................................................................................................4 3.3GENERALDESCRIPTIONOFBLE...................................................................................................................................4 4RFEXPOSUREEVALUATION.......................................................................................................................................5 4.1SAREVALUATIONFORPORTABLECONDITION...........................................................................................................5 4.1.1StandardRequirement......................................................................................................................................5 4.1.2Limits....................................................................................................................................................................5 4.1.3SARExclusionEvaluationResult...................................................................................................................7 ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20251102731E-02 Page:4of7 3GeneralInformation 3.1ClientInformation Applicant:ShenzhenInateckTechnologyCo.,Ltd. AddressofApplicant:Rm.2507,Bldg.11,TianAnCloudPark,BantianStreet,LonggangDistrict, Shenzhen,China. Manufacturer:ShenzhenInateckTechnologyCo.,Ltd. AddressofManufacturer:Rm.2507,Bldg.11,TianAnCloudPark,BantianStreet,LonggangDistrict, Shenzhen,China. Factory:ShenzhenInateckTechnologyCo.,Ltd. AddressofFactory:Rm.2507,Bldg.11,TianAnCloudPark,BantianStreet,LonggangDistrict, Shenzhen,China. 3.2GeneralDescriptionofEUT ProductName: Keyboard ModelNo.: N0073,N0074,N0075,N0076,N0077,N0078,N0079,N0080,N0081 TestModelNo.: N0073 TradeMark: inateck SoftwareVersion: V01 HardwareVersion: V01 PowerSupply: Li-ionbatteryDC3.7V500mAh,ChargebyDC5Vforadapter SimultaneousTransmissionSimultaneousTXissupportedandevaluatedinthisreport. SimultaneousTXisnotsupported. 3.3GeneralDescriptionofBLE OperationFrequency:2402MHz~2480MHz ModulationType:GFSK TransferRate:1Mbps NumberofChannel:40 ProductType:MobilePortableFixLocation AntennaType: PCBantenna AntennaGain: 1.87dBi ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20251102731E-02 Page:5of7 4RFExposureEvaluation 4.1 SAREvaluationforPortablecondition 4.1.1StandardRequirement 447498D04InterimGeneralRFExposureGuidancev01 3.2.SARTestReductionGuidance SARtestreductionprocedures[Glossary]allowusingaparticularsetoftestdataasrepresentative ofother,similar,testconditions.Thismaybeappliedfordatawithindifferenttestpositions(e.g.body, head,extremity),wirelessmodes(e.g.Wi-Fi,cellular),andfrequencybands.Thistestreductionprocess providesfortheuseoftestdataforonespecificchannel,whilereferencingtothosedatafordemonstrating complianceinotherrequiredchannelsforeachtestpositionofanexposurecondition,withintheoperating modeofafrequencyband.Thisislimitedspecificallytowhenthereported1-gor10-gSARforthemid- bandorhighestoutputpowerchannelmeetsanyofthefollowingconditions. 4.1.2Limits SAR-basedthresholdsarederivedbasedonfrequency,power,andseparationdistanceoftheRF source.Theformuladefinesthethresholdsingeneralforeitheravailablemaximumtimeaveragedpoweror maximumtime-averagedERP,whicheverisgreater. IftheERPofadeviceisnoteasilydetermined,suchasforaportabledevicewithasmallform factor,theapplicantmayusetheavailablemaximumtime-averagedpowerexclusivelyifthe deviceantennaorradiatings…

Text truncated - open the document above for the full version.

Test Report

Antenna type :PCBAntenna model: HLK_AT2Trademark: NoneFrequency band: 2402-2480MHz Manufacturer: Shenzhen Haiqi Electronic Technology Co., Ltd., 2nd Floor, Building 19, Baotian Industrial Park, Baotian 3rd Road, Xixiang Street, Bao'an District, Shenzhen Tested Products. • Antenna 1: integrated antenna. • Frequency = 2.402GHz. • Frequency = 2.441GHz. • Frequency = 2.480GHz. Coordinate System Reference: Antenna 1. Radiation pattern: Antenna 1. XZ Plane at f = 2.402GHz Co-cross polarization field (dBi) Solid line: vertical polarizationDash line: horizontal polarization Total field (dBi) 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 -15 -20 -20 -25 -25 -30 -30 -35 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 Radiation pattern: Antenna 1. YZ Plane at f = 2.402GHz Co-cross polarization field (dBi) Solid line: vertical polarizationDash line: horizontal polarization Total field (dBi) 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 -15 -20 -20 -25 -25 -30 -30 -35 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 Radiation pattern: Antenna 1. XY Plane at f = 2.402GHz Co-cross polarization field (dBi) Solid line: vertical polarizationDash line: horizontal polarization Total field (dBi) 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 -15 -20 -20 -25 -25 -30 -30 -35 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 Radiation pattern: Antenna 1. XZ Plane at f = 2.441GHz Co-cross polarization field (dBi) Solid line: vertical polarizationDash line: horizontal polarization Total field (dBi) 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 -15 -20 -20 -25 -25 -30 -30 -35 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 Radiation pattern: Antenna 1. YZ Plane at f = 2.441GHz Co-cross polarization field (dBi) Solid line: vertical polarizationDash line: horizontal polarization Total field (dBi) 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 -15 -20 -20 -25 -25 -30 -30 -35 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 Radiation pattern: Antenna 1. XY Plane at f = 2.441GHz Co-cross polarization field (dBi) Solid line: vertical polarizationDash line: horizontal polarization Total field (dBi) 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 -15 -20 -20 -25 -25 -30 -30 -35 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 Radiation pattern: Antenna 1. XZ Plane at f = 2.480GHz Co-cross polarization field (dBi) Solid line: vertical polarizationDash line: horizontal polarization Total field (dBi) 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 -15 -20 -20 -25 -25 -30 -30 -35 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 Radiation pattern: Antenna 1. YZ Plane at f = 2.480GHz Co-cross polarization field (dBi) Solid line: vertical polarizationDash line: horizontal polarization Total field (dBi) 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 -15 -20 -20 -25 -25 -30 -30 -35 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 Radiation pattern: Antenna 1. XY Plane at f = 2.480GHz Co-cross polarization field (dBi) Solid line: vertical polarizationDash line: horizontal polarization Total field (dBi) 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 -15 -20 -20 -25 -25 -30 -30 -35 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 Return Loss: Antenna 1 BW(-10dB) ¡ 13.48% 2 2.2 2.4 2.6 2.8 3 Frequency (GHz) -16-14-12-10 -8-6-4-2 R e t u r n L o s s ( d B ) Measurements summary Frequency (GHz) Plane Return Loss (dB) Polarization Gain max. (dBi) θ for Gain max. φ for Gain max. Antenna 1 2.402 XZ -10.90 Vertical -7.8 290 2.402 XZ -10.90 Horizontal 0.786 182 2.402 YZ -10.90 Vertical 1.21 226 2.402 YZ -10.90 Horizontal -7.75 10 2.402 XY -10.90 Vertical -15.4 20 2.402 XY -10.90 Horizontal 0.93 180 2.441 XZ -12.20 Vertical -7.36 318 2.441 XZ -12.20 Horizontal 1.32 180 2.441 YZ -12.20 Vertical 0.981 204 2.441 YZ -12.20 Horizontal -8.23 24 2.441 XY -12.20 Vertical -14.1 -14 2.441 XY -12.20 Horizontal 1.74 180 2.48 XZ -13.80 Vertical -7.95 312 2.48 XZ -13.80 Horizontal 1.81 186 2.48 YZ -13.80 Vertical 0.204 214 2.48 YZ -13.80 Horizontal -8.38 8 2.48 XY -13.80 Vertical -15.8 12 2.48 XY -13.80 Horizontal 1.87 180

Test Report

ShenzhenHuaxiaTestingTechnologyCo.,Ltd. 1F.,BlockAofTongshengTechnologyBuilding,HuahuiRoad,DalangStreet,LonghuaDistrict, Shenzhen,China Telephone:+86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com ReportTemplateVersion:V05 ReportTemplateRevisionDate:2021-11-03 TestReport Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthisreportreferonly tothesample(s)tested.WithoutwrittenapprovalofCQA,thisreportcan’tbereproducedexceptinfull. ReportNo.:CQASZ20251102731E-01 Applicant:ShenzhenInateckTechnologyCo.,Ltd. AddressofApplicant:Rm.2507,Bldg.11,TianAnCloudPark,BantianStreet,LonggangDistrict, Shenzhen,China. EquipmentUnderTest(EUT): Product:Keyboard ModelNo.:N0073,N0074,N0075,N0076,N0077,N0078,N0079,N0080,N0081 TestModelNo.:N0073 BrandName:inateck FCCID:2A2T9-N0073 Standards:47CFRPart15,SubpartC KDB558074D0115.247MeasGuidancev05r02 ANSIC63.10:2020 DateofReceipt:2025-11-26 DateofTest: 2025-11-26to2026-01-05 DateofIssue:2026-01-21 TestResult:PASS* *Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove. TestedBy: (LewisZhou) ReviewedBy: (TimoLei) ApprovedBy: (JackAi) ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20251102731E-01 Page: 2 of 50 1Version RevisionHistoryOfReport ReportNo.Version Description IssueDate CQASZ20251102731E-01Rev.01Initialreport2026-01-21 ModelNo.:N0073,N0074,N0075,N0076,N0077,N0078,N0079,N0080,N0081. Theirelectricalcircuitdesign,layout,componentsusedandinternalwiringareidentical, Onlythemodelisdifferent. ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20251102731E-01 Page: 3 of 50 2TestSummary TestItemTestRequirementTestmethodResult AntennaRequirement 47CFRPart15,SubpartCSection 15.203/15.247(c) ANSIC63.102020PASS ACPowerLine Conducted Emission 47CFRPart15,SubpartCSection 15.207 ANSIC63.102020PASS ConductedPeakOutput Power 47CFRPart15,SubpartCSection 15.247(b)(3) ANSIC63.102020PASS 6dBOccupied Bandwidth 47CFRPart15,SubpartCSection 15.247(a)(2) ANSIC63.102020PASS PowerSpectralDensity 47CFRPart15,SubpartCSection 15.247(e) ANSIC63.102020PASS Band-edgeforRF ConductedEmissions 47CFRPart15,SubpartCSection 15.247(d) ANSIC63.102020PASS RFConductedSpurious Emissions 47CFRPart15,SubpartCSection 15.247(d) ANSIC63.102020PASS RadiatedSpurious Emissions 47CFRPart15,SubpartCSection 15.205/15.209 ANSIC63.102020PASS Restrictedbandsaround fundamentalfrequency (RadiatedEmission) 47CFRPart15,SubpartCSection 15.205/15.209 ANSIC63.102020PASS ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20251102731E-01 Page: 4 of 50 3Contents Page 1VERSION..........................................................................................................................................................................2 2TESTSUMMARY............................................................................................................................................................3 3CONTENTS......................................................................................................................................................................4 4GENERALINFORMATION...........................................................................................................................................5 4.1CLIENTINFORMATION.................................................................................................................................................5 4.2GENERALDESCRIPTIONOFEUT.................................................................................................................................5 4.3ADDITIONALINSTRUCTIONS........................................................................................................................................7 4.4TESTENVIRONMENT...................................................................................................................................................8 4.5DESCRIPTIONOFSUPPORTUNITS...............................................................................................................................8 4.6TESTCONFIGURATION................................................................................................................................................8 4.7STATEMENTOFTHEMEASUREMENTUNCERTAINTY....................................................................................................9 4.8TESTLOCATION........................................................................................................................................................10 4.9TESTFACILITY..........................................................................................................................................................10 4.10DEVIATIONFROMSTANDARDS................................................................................................................................10 4.11OTHERINFORMATIONREQUESTEDBYTHECUSTOMER..........................................................................................10 4.12EQUIPMENTLIST.....................................................................................................................................................11 5TESTRESULTSANDMEASUREMENTDATA.....................................................................................................12 5.1ANTENNAREQUIREMENT..........................................................................................................................................12 5.2CONDUCTEDEMISSIONS............................................................................................................................................13 5.3CONDUCTEDPEAKOUTPUTPOWER..........................................................................................................................17 5.46DBOCCUPYBANDWIDTH........................................................................................................................................21 5.5POWERSPECTRALDENSITY..............................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Setupphotos 1Photographs-EUTTestSetup 1.1RadiatedSpuriousEmission 9kHz~30MHz: 30MHz~1GHz: FCC ID: 2A2T9-N0073 Above1GHz: 1.2ConductedEmissionsTestSetup 1.3RFConductedmeasurement

Contact Information

Applicant

Fret Huang
[email protected]Fax: 0755-23484029

Technical Contact

FCC US Agent inc.David Wilson
[email protected]

6464 Dillon Dr Unit 93 Pueblo · Colorado, 81008 · United States

Test Firm

Shenzhen Huaxia Testing Technology Co., LtdJack Ai
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.90 mW
Confidentiality
Long Term
Grant Notes
Power listed is maximum peak conducted output power. This filing meets the SAR threshold exclusion set forth in KDB 447498 and therefore can be used in mobile/portable configurations. The antenna used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Shenzhen Inateck Technology Co., Ltd.

Keyboard - FCC ID 2A2T9-N0046 - Shenzhen Inateck Technology Co., Ltd.
2A2T9-N0046

Keyboard

Jun 18, 2026

Equipment Class

DTS - Digital Transmission System
Handheld Terminal - FCC ID 2A2T9-N6029 - Shenzhen Inateck Technology Co., Ltd.
2A2T9-N6029

Handheld Terminal

May 10, 2026

Equipment Class

DTS - Digital Transmission System
Keyboard - FCC ID 2A2T9-N0064 - Shenzhen Inateck Technology Co., Ltd.
2A2T9-N0064

Keyboard

May 06, 2026

Equipment Class

DTS - Digital Transmission System
Barcode Scanner - FCC ID 2A2T9-N6015 - Shenzhen Inateck Technology Co., Ltd.
2A2T9-N6015

Barcode Scanner

Mar 18, 2026

Equipment Class

DTS - Digital Transmission System
Keyboard - FCC ID 2A2T9-N0055 - Shenzhen Inateck Technology Co., Ltd.
2A2T9-N0055

Keyboard

Dec 18, 2025

Equipment Class

DTS - Digital Transmission System