FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. AplusX Inc./
  3. 2A2TU-PESXL521

2A2TU-PESXL521Pulsar eS Xlite Wireless Gaming mouse

AplusX Inc.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 20, 2026
Application Purpose
Original Equipment
Equipment Note
Pulsar eS Xlite Wireless Gaming mouse
Frequency Range
2402.00000000 - 2480.00000000
Company
AplusX Inc.
Country
South Korea

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

(AplusX Inc.) (2026.09.09) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID: 2A2TU-PESXL521) [AplusX Inc.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, the equipment does not utilize cyber-security or anti-virus software from Kaspersky Lab, Inc, or any of its successors and assignees, which is also on the “covered list”. Sincerely, (Applicant signature) (Applicant printed name) Kunhee Shim (Title) Manager (Company) AplusX Inc. (AplusX Inc.) (2026.09.09) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCC ID: 2A2TU-PESXL521) [AplusX Inc.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) Kunhee Shim (Title) Manager (Company) AplusX Inc.

Attestation Statements

Rev 1/26/2023 AplusX Inc. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 09-07-2026 Ref: Attestation Statements Part 2.911(d)(7) Filing Applicant Information: FCC ID :2A2TU-PESXL521 Applicant FRN: 0031243603 Company Name: AplusX Inc. Address: A-614, 58-1 Giheung-Ro, Giheung-Gu, Yongin-Si, Gyeonggi-Do, South Korea Contact Person: Kunhee Shim Phone: +82 10 8872 7471 Email: [email protected] [AplusX Inc.] certifies that, as of the date of the filing of the application, [FCC US Agent, LLC] is our designated U.S. agent for service of process for the above referenced FCC ID. [AplusX Inc.] accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. [FCC US Agent, LLC] accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Company Name: FCC US Agent, LLC FRN: 0033402884 Address: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA Contact Person: Tim Payne Phone: 708-571-3148 Email: [email protected] Sincerely, [AplusX Inc.] FCC US Agent, LLC [Kunhee Shim] Tim Payne

Cover Letter(s)

AplusX Inc. (2026.09.09) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR EUT NAME: Pulsar eS Xlite Wireless Gaming mouse Trademark: Pulsar Gaming Gears MODEL : PESXL521, PESXL522, PESXL523, PESXL524, PESXL525, PESXL526, PESXL527, PESXL528, PESXL529, PESXL5210, PESXL5211, PESXL5212, PESXL5213, PESXL5214, PESXL5215, PESXL5216, PESXL5217, PESXL5218, PESXL5219, PESXL5220 FCC ID : 2A2TU-PESXL521 To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the - Block Diagram - Schematics - Operational Description required to be submitted with this application be permanently withheld from public review. The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Pursuant to DA 04-1705, the applicant also requests temporary confidential treatment of the exhibits outlined below for a period of (up to 180) days from the date of equipment authorization and prior to marketing in the United States to prevent the premature release of any sensitive information. Applicant is aware of their responsibility to notify NACS in the event information regarding the product or the product is made available to the public before the requested period has expired. - User Manual - Internal Photos - External Photos - Test Setup Photos Please contact me if there is any information you may need. Sincerely, (Signature) (Print name) Kunhee Shim (Title) Manager (Company) AplusX Inc.

Cover Letter(s)

AplusX Inc. (2026.09.09) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize (Shenzhen BCTC Technology Co., Ltd.) to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, (Signature) (Print name) Kunhee Shim (Title) Manager (Company) AplusX Inc.

Cover Letter(s)

AplusX Inc. Model Difference 2026-09-09 EUT NAME: Pulsar eS Xlite Wireless Gaming mouse FCC ID: 2A2TU-PESXL521 MODEL : PESXL521, PESXL522, PESXL523, PESXL524, PESXL525, PESXL526, PESXL527, PESXL528, PESXL529, PESXL5210, PESXL5211, PESXL5212, PESXL5213, PESXL5214, PESXL5215, PESXL5216, PESXL5217, PESXL5218, PESXL5219, PESXL5220 All the model are the same circuit and RF module, except model names and color. Regards Sincerely Client’s signature: Client’s name / title : Kunhee Shim / Manager Contact information / address: A-614, 58-1 Giheung-Ro, Giheung-Gu, Yongin-Si, Gyeonggi-Do, South Korea

ID Label/Location Info

Size:18*14mm Label Location

RF Exposure Info

RF EXPOSURE EVALUATION METHOD FCC ID: 2A2TU-PESXL521 Applicable standard: In accordance with FCC 47 CFR part 2 (2.1093) this device has been defined as a portable device which is defined as a transmitting device designed to be used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the user. Portable devices must be evaluated using the specified in FCC 47 CFR part 2 (2.1093) and ANSI/IEEEC95.1-1992. and had been tested in accordance with the measurement methods and procedures specified in IEEE 1528-2003. Per FCC KDB 447498 D01 v06, the 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances s 50 mm are determined by: SAR Test Exclusion Thresholds for 100 MHz – 6 GHz and ≤ 50 mm Approximate SAR Test Exclusion Power Thresholds at Selected Frequencies and Test Separation Distances are illustrated in the following Table. The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. Condition Frequency (MHz) Conducted Power (dBm) NVNT 2402 1.43 NVNT 2440 1.69 NVNT 2480 1.37 max possible output power (PK,conducted):1±1dBm 2dBm=1.58mW 2402MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]= 1.58/5*√2.402=0.49≤3.0 2440MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]= 1.58/5*√2.44=0.494≤3.0 2480MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]= 1.58/5*√2.48=0.498≤3.0 Conclusion: 1. [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] * [√f(GHz)] < 3.0. 2. SAR Test Exclusion Thresholds is 3.0 for separation distance 5mm. Therefore, SAR test is not required.

Test Report

DEKRA Testing and Certification No. 26, Huaya 1st Rd., Guishan Dist., Taoyuan City 333411 , Taiwan TEL: +886-3-725-7255 www.dekra-certification.com 2610275R-A324310010-A Antenna Measurement Report Model: NP-01S V3 Wireless Equipment Name: Mouse Brand (Trade) Name: VAXEE Applicant: CJ Chuang JYU International Ltd. 3 F., No. 111, Minquan Rd., Tamsui Dist., New Taipei City 251033, Taiwan (R.O.C.) Manufacturer: CJ Chuang JYU International Ltd. 3 F., No. 111, Minquan Rd., Tamsui Dist., New Taipei City 251033, Taiwan (R.O.C.) Antenna Type: VAXEE Wireless V2 Antenna Tested by (name / position & signature) Lucas Liu / Engineer Approved by (name / position & signature) Lorien Chang / Manager Date of issue 2026/02/24 2026/02/24 2026/20/24 DEKRA Testing and Certification No. 26, Huaya 1st Rd., Guishan Dist., Taoyuan City 333411 , Taiwan TEL: +886-3-725-7255 www.dekra-certification.com 2610275R-A324310010-A Competences and guarantees DEKRA is a testing laboratory competent to carry out the tests described in this report. In order to assure the traceability to other national and international laboratories, DEKRA has a calibration and maintenance program for its measurement equipment. DEKRA guarantees the reliability of the data presented in this report, which is the result of the measurements and the tests performed to the item under test on the date and under the conditions stated in the report and it is based on the knowledge and technical facilities available at DEKRA at the time of performance of the test. DEKRA is liable to the client for the maintenance of the confidentiality of all information related to the item under test and the results of the test. The results presented in this Test Report apply only to the particular item under test established in this document. IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means, except in full, without the previous written permission of DEKRA Testing and Certification. General conditions 1.This report is only referred to the item that has undergone the test. 2.This report does not constitute or imply on its own an approval of the product by the Certification Bodies or competent Authorities. 3.This document is only valid if complete; no partial reproduction can be made without previous written permission of DEKRA Testing and Certification. 4.This test report cannot be used partially or in full for publicity and/or promotional purposes without previous written permission of DEKRA Testing and Certification. Data provided by the client The following data has been provided by the client: 1.No DEKRA Testing and Certification declines any responsibility with respect to the information provided by the client and that may affect the validity of results. DEKRA Testing and Certification No. 26, Huaya 1st Rd., Guishan Dist., Taoyuan City 333411 , Taiwan TEL: +886-3-725-7255 www.dekra-certification.com 2610275R-A324310010-A Testing period and place Test Location DEKRA Testing and Certification No. 26, Huaya 1st Rd., Guishan Dist., Taoyuan City 333411 , Taiwan Date (start) 2026/01/17 Date (finish) 2026/01/17 Document history Report number Revision Date Description 2610275R- A324310010-A Rev. 1.0 2026/02/24 First Release Environmental conditions The climatic conditions during the tests are within the limits specified by the manufacturer for the operation of the EUT and the test equipment. The climatic conditions during the tests were within the following limits: Ambient temperature 22 °C – 28 °C Relative Humidity air < 60% Testing verdicts Not applicable: N/A Pass: P Fail: F Infomation: Info Not measured: N/M Used Equipment Name Manufacturer Type/Model Serial Number Calibration Last Cal. Vector Network Analyzer R&S ZNB 8 106333 2025/5/21 Measurement Software ETS-Lindgren EMQuest 1.17 1474 N/A DEKRA Testing and Certification No. 26, Huaya 1st Rd., Guishan Dist., Taoyuan City 333411 , Taiwan TEL: +886-3-725-7255 www.dekra-certification.com 2610275R-A324310010-A 1.TEST CONDITIONS 1.1 Power supply (V) Power supply (V) under test: N/A 1.2 Temperature (ºC) Tn = +22 to +28 The subscript n indicates normal test conditions. 1.3 Device orientation and Setup Requirements The EUT has only one mechanical configuration and it was tested in the scenario required by the standard [1]: •“Free-space” configuration, whereby the EUT has been placed directly on a support. The EUT is rotated along two different spherical axes: theta (θ) and phi (Φ). The relationship between the 3D Cartesian coordinate system (X, Y, Z) and the theta and phi axes is illustrated in the following figure. Theta is the spherical axis that rotates along the Cartesian Y axis while Phi is the spherical axis that rotates along the Cartesian Z axis. The initial measurement position (Theta = 0º and Phi = 0º) is illustrated in each of the test setup photographs. The EUT has only one mechanical configuration each and it was tested in the Free-space configuration, whereby the EUT has been placed directly on a support. DEKRA Testing and Certification No. 26, Huaya 1st Rd., Guishan Dist., Taoyuan City 333411 , Taiwan TEL: +886-3-725-7255 www.dekra-certification.com 2610275R-A324310010-A 2.TEST RESULTS 2.1 Antenna Passive Test Report 3D Passive Test Result Mouse(NP-01S V3 Wireless) Frequency (MHz) Tot. Rad. Pwr. (dBm) Peak EIRP (dBm) Directivity (dBi) Efficiency (dB) Efficiency (%) Gain (dBi) NHPRP ±Pi/4 (dBm) NHPRP ±Pi/6 (dBm) 2400 -8.53-2.615.93 -8.5314.02 -2.61-10.56-12.42 2403 -8.49-2.476.02 -8.4914.16 -2.47-10.53-12.40 2412 -8.23-2.305.92 -8.2315.04 -2.30-10.23-12.12 2437 -8.10-2.026.07 -8.1015.50 -2.02-10.02-11.89 2441 -8.20-2.265.94 -8.2015.14 -2.26-10.08-11.93 2462 -8.43-2.525.91 -8.4314.35 -2.52-10.19-12.00 2480 -8.20-2.375.83 -8.2015.13 -2.37-9.89-11.70 2500 -8.13-2.076.06 -8.1315.37 -2.07-9.79-11.63 DEKRA Testing and Certification No. 26, Huaya 1st Rd., Guishan Dist., Taoyuan City 333411 , Taiwan TEL: +886-3-725-7255 www.dekra-certification.com 2610275R-A32431…

Text truncated - open the document above for the full version.

Test Report

No.:BCTC/KJ-RF-ICT-001 Page 1 of 43 Edition:B.1 TEST REPORT Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC2607034818E Applicant: AplusX Inc. Product Name: Pulsar eS Xlite Wireless Gaming mouse Test Model: PESXL521 Tested Date: 2026-07-30 to 2026-08-12 Issued Date: 2026-08-13 Report No.: BCTC2607034818E No.:BCTC/KJ-RF-ICT-001 Page 2 of 43 Edition:B.1 FCC ID: 2A2TU-PESXL521 The test report is effective only with both signature and specialized stamp.This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen BCTC Technology Co., Ltd, this report can’t be reproduced except in full.The tested sample(s) and the sample information are provided by the client. Product Name: Pulsar eS Xlite Wireless Gaming mouse Trademark: Pulsar Gaming Gears Model/Type Ref.: PESXL521 PESXL522, PESXL523, PESXL524, PESXL525, PESXL526, PESXL527, PESXL528, PESXL529, PESXL5210, PESXL5211, PESXL5212, PESXL5213, PESXL5214, PESXL5215, PESXL5216, PESXL5217, PESXL5218, PESXL5219, PESXL5220 Prepared For: AplusX Inc. Address: A-614, 58-1 Giheung-Ro, Giheung-Gu, Yongin-Si, Gyeonggi-Do, South Korea Manufacturer: AplusX Technology (Shenzhen) Co.,Ltd Address: Building A, Unit 801-1, Block 1, Xingzhan Plaza, 446 Nanhuan Road, Shajing, Bao'an District, Shenzhen, China Prepared By: Shenzhen BCTC Technology Co., Ltd. Address: Room 101M, Unit 1, Building1, Pengyuan, No.18, Lilang Road, Shanglilang, Nanwan Subdistrict, Longgang District, Shenzhen, Guangdong, China. Sample Received Date: 2026-07-30 Sample tested Date: 2026-07-30 to 2026-08-12 Report No.: BCTC2607034818E Test Standards: 47 CFR Part 15 Subpart C (clause 15.247) ANSI C63.10-2020 Test Results: PASS Remark: This is SRD 2.4GHz radio test report. Prepared by : Reviewer by : Approved by: Louis Zeng Mike Zheng Sewen Guo Report No.: BCTC2607034818E No.:BCTC/KJ-RF-ICT-001 Page 3 of 43 Edition:B.1 Table of Content Test Report Declaration Page 1. Version .................................................................................................................. 5 2. Test Summary ....................................................................................................... 6 3. Measurement Uncertainty ..................................................................................... 7 4. Product Information And Test Setup ..................................................................... 8 4.1 Product Information ............................................................................................... 8 4.2 Test Setup Configuration ...................................................................................... 9 4.3 Support Equipment ............................................................................................... 9 4.4 Channel List ........................................................................................................ 10 4.5 Test Mode ........................................................................................................... 10 4.6 Table Of Parameters Of Text Software Setting ................................................... 11 5. Test Facility And Test Instrument Used ............................................................... 12 5.1 Test Facility ......................................................................................................... 12 5.2 Test Instrument Used .......................................................................................... 12 6. Conducted Emissions .......................................................................................... 14 6.1 Block Diagram Of Test Setup .............................................................................. 14 6.2 Limit .................................................................................................................... 14 6.3 Test procedure .................................................................................................... 14 6.4 EUT Operating Conditions .................................................................................. 14 6.5 Test Result ............................................................................................................ 15 7. Radiated Emissions ............................................................................................. 17 7.1 Block Diagram Of Test Setup .............................................................................. 17 7.2 Limit .................................................................................................................... 18 7.3 Test procedure .................................................................................................... 19 7.4 EUT operating Conditions ................................................................................... 20 7.5 Test Result .......................................................................................................... 21 8. Radiated Band Emission Measurement and Restricted Bands Of Operation ...... 25 8.1 Block Diagram Of Test Setup .............................................................................. 25 8.2 Limit .................................................................................................................... 25 8.3 Test Procedure ................................................................................................... 26 8.4 EUT Operating Conditions .................................................................................. 26 8.5 Test Result .......................................................................................................... 27 9. Power Spectral Density Test ............................................................................... 28 9.1 Block Diagram Of Test Setup .............................................................................. 28 9.2 Limit .................................................................................................................... 28 9.3 Test procedure…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Kunhee Shim
[email protected]Fax: +82 303 3441 7471

Technical Contact

FCC US Agent, LLCTim Payne
[email protected]

3722 Illinois Avenue · Saint Charles, Illinois, 60174 · United States

Test Firm

Shenzhen BCTC Technology Co., Ltd.Sally He
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.48 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is conducted.

Other Applications from AplusX Inc.

2A2TU-PRSSSTX221

Pulsar Pro series Susanto-X 2.0 Wireless gaming mouse

Jul 30, 2026

Equipment Class

DTS - Digital Transmission System
2A2TU-PL28KDG01

Pulsar LINK 2 Dongle

Jun 10, 2026

Equipment Class

DTS - Digital Transmission System
2A2TU-FMF01XS201

Pulsar F01 XS-2 Wireless Gaming mouse

Jun 10, 2026

Equipment Class

DTS - Digital Transmission System
Pulsar Pro Series Jinggg-X Wireless Gaming mouse - FCC ID 2A2TU-PJGX21 - AplusX Inc.
2A2TU-PJGX21

Pulsar Pro Series Jinggg-X Wireless Gaming mouse

Apr 15, 2026

Equipment Class

DTS - Digital Transmission System
2A2TU-PCRPX21

Pulsar Pro Series CARPE-X Wireless Gaming mouse

Feb 24, 2026

Equipment Class

DTS - Digital Transmission System