FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. ShenZhen FLYSKY Technology Co.,Ltd/
  3. 2A2UNR11P02

2A2UNR11P0211-CHANNEL RECEIVER

ShenZhen FLYSKY Technology Co.,Ltd
11-CHANNEL RECEIVER - FCC ID 2A2UNR11P02 - ShenZhen FLYSKY Technology Co.,Ltd
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Mar 17, 2024
Application Purpose
Original Equipment
Date of Application
Mar 17, 2024
Equipment Note
11-CHANNEL RECEIVER
Frequency Range
2408.00000000 - 2475.00000000
Company
ShenZhen FLYSKY Technology Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Neck Strap Hook Basic Operations Specifications Certifications Read the safety messages listed below before operation! • Do not use the product at night or during bad weather conditions, like rain or thunderstorms. It can cause erratic operation or loss of control. • Do not use the product when visibility is limited. • Do not expose the product to rain or snow. Any exposure to moisture (water or snow) may cause erratic operation or loss of control. • Interference may cause loss of control. To ensure the safety of you and others, do not operate in the following places: Thank you for purchasing the products of Flysky! To find out more about our products, visit our website at www.flysky-cn.com. If you encounter any problems during using, please refer to the manual first. If the problem is still not resolved, consult your local dealer directly or contact the customer service staff via Flysky official website. • Do not use this product when you are tired, uncomfortable, or under the influence of alcohol or drugs. Doing so may cause serious injury to yourself or others. • The 2.4GHz radio band is limited to line of sight. Always keep your model in sight as a large can block the RF signal and lead to loss of control. • Never grip the transmitter antenna during operation. It significantly degrades signal quality and strength and may cause loss of control. • Do not touch any part of the model that may generate heat during operation, or immediately after use. The engine, motor or speed control, may be very hot and can cause serious burns. • Misuse of this product may lead to serious injury or death. To ensure the safety of you and your equipment, read this manual and follow the instructions carefully. • Make sure the product is properly installed in your model. Failure to do so may result in serious injury. • Ensure that all servos operate in the correct direction. If not, adjust the direction first. • Make sure that the model stays within range in order to prevent loss of control. • The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-lacated or operating in conjunction with any other transmitter.End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. CAUTION! • RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS. Precautions Near any sites where other radio control activity may occur Near people or roads On any pond/ lake when passenger boats are present Near power lines or communication broadcasting antennas Transmitter Overview 本说明书中的图片和插图仅供参考,可能与实际产品外观有所不同。 产品设计和规格可能会有所更改,恕不另行通知。 Figures and illustrations in this manual are provided for reference only and may differ from actual product appearance. Product design and specificatiions may be changed without notice. Manufacturer: ShenZhen FLYSKY Technology Co., Ltd. Address: 16F, Huafeng Building, No. 6006 Shennan Road, Futian District, Shenzhen, Guangdong, China Product ModelFS-MG11-BT-BS Compatible ReceiversFS-R11P-BT-BS, FS-R11D-ESC-BS, FS-R11P-BS Compatible Models Car Number of Channels11 RF2.4GHz ISM Maximum Power<20dBm (e.i.r.p.) (EU) 2.4G Protocol2A-BS Resolution4096 Input Power1.5AA*4 or 2S Lipo Working CurrentAbout 60mA/6V Low Voltage AlarmYes AntennaSingle Built-in Antenna Charging JackNone (The USB Type-C port is only used for power supply.) Online UpdateYes Data OutputNone Distance﹥ 150m(Ground Distance Without Interference) Temperature Range-10°C ~ +60°C Humidity Range20% ~ 95% Dimensions135.7*189.1*82.7mm Weight236g ColorBlack CertificationsCE, FCC ID: 2A2UNMG11OO FCC Compliance Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Warning: changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. EU DoC Declaration Hereby, [Flysky Technology Co., Ltd.] declares that the Radio Equipment [ FS-MG11-BT-BS&FS-R11P-BT-BS] is in compliance with RED 2014/53/EU. The full text of the EU DoC is available at the following internet address: www.flyskytech.com/info_detail/10.html RF Exposure Compliance The distance between user and products should be no less than 20cm. Environmentally friendly disposal Old electrical appliances must not be disposed of together with the residual waste, but have to be disposed of separately. The disposal at the communal collecting point via private persons is for free. The owner of old appliances is responsible to bring the appliances to these collecting points or to similar collection poi…

Text truncated - open the document above for the full version.

Attestation Statements

ShenZhen FLYSKY Technology Co.,Ltd * the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. U.S. Agent Designation for Service of Process - Certification Attestation Letter Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA ATTN.: Reviewing Engineer FCC ID: 2A2UNR11P02 FRN of applicant: 0031248305 Per section 2.911(d)(7) of the FCC rules, ShenZhen FLYSKY Technology Co.,Ltd certifies that the equipment for which authorization is sought is designated to the following U.S. agent* for service of process: Company Name: Baihetian Innovative Solutions FCC Registration Number (FRN): 0033401605 Physical U.S. Company Address: 6837 Chase Rd, Dearborn, MI 48126, USA Contact Person: Kenneth Young Agent Email Address: [email protected] The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Signed: Signed: Printed name: Kyle Li Title: RD Manager Company Name: ShenZhen FLYSKY Technology Co.,Ltd Date: 3/12/2024 Agent Signed: Signed: Printed name: Kenneth Young Title: Manager Company Name: Baihetian Innovative Solutions Date: 3/12/2024

Attestation Statements

ShenZhen FLYSKY Technology Co.,Ltd Covered Equipment Certification Attestation Letter 3/6/2024 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA ATTN.: Reviewing Engineer FCC ID: 2A2UNR11P02 ShenZhen FLYSKY Technology Co.,Ltd certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, the applicant should include an explanation on why the equipment is not “covered” equipment. ShenZhen FLYSKY Technology Co.,Ltd certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Signed: Printed name: Kyle Li Title: RD Manager Company Name: ShenZhen FLYSKY Technology Co.,Ltd Date: 3/6/2024

Cover Letter(s)

ShenZhen FLYSKY Technology Co.,Ltd DATE : 2024-03-06 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2A2UNR11P02 Product Name: 11-CHANNEL RECEIVER Request for Confidentiality To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuantto KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Signature: Name: Kyle Li Title: RD Manager

Cover Letter(s)

DATE : 2024-03-06 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act as Agent On our behalf, I appoint Jason Wu of Global United Technology Services Co., Ltd.and No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, still resides with ShenZhen FLYSKY Technology Co.,Ltd and 16F, Huafeng Building, No. 6006 Shennan Road, Futian District, Shenzhen, Guangdong, China Signature: Name: Kyle Li Title: RD Manager Company: ShenZhen FLYSKY Technology Co.,Ltd

External Photos

Page 1 of 3 Test Model No.: FS‐R11P‐BT‐BS Page 2 of 3 Page 3 of 3

ID Label/Location Info

20231116 0.175磨砂PC+513胶 21.13*13.26mm 01 彩色印刷 FS-R11P-BT-BS接收机 FS-R11P-BT-BS接收机贴纸 B-TFSR11PBTBS-01 Adobe Illustrator CC 2018 李德平 产品经理确认 PANTONE 478 C PANTONE Black 6C White

Internal Photos

Page 1 of 3 Test Model No.: FS‐R11P‐BT‐BS Page 2 of 3 Page 3 of 3

RF Exposure Info

FCC ID: 2A2UNR11P02 RF Exposure Evaluation Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (A) Limits for Occupational/Controlled Exposures 0.3–3.0 614 1.63 *(100) 6 3.0–30 1842/f 4.89/f *(900/f 2 ) 6 30–300 61.4 0.163 1.0 6 300–1500 f/300 6 1500–100,000 5 6 (B) Limits for General Population/Uncontrolled Exposure 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f 2 ) 30 30–300 27.5 0.073 0.2 30 300–1500 f/1500 30 1500–100,000 1.0 30 f = frequency in MHz Friis transmission formula: Pd = (Pout*G)/(4*pi*r 2 ) Where Pd = power density in mW/cm 2 , Pout = output power to antenna in mW; G = gain of antenna in linear scale, Pi = 3.1416; R = distance between observation point and center of the radiator in cm Pd id the limit of MPE, 1 mW/cm 2 . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. Test Procedure Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. FCC ID: 2A2UNR11P02 Test Result of RF Exposure Evaluation Channel Output power to antenna (dBm) Output power to antenna (mW) Power Density at R=20cm (mW/cm2) Limit (mW/cm2) Result 2440MHz 6.27 4.24 0.0007 1.0 PASS Remark: antenna gain=-1.11dBi

Test Report

Global United Technology Services Co., Ltd. Report No.: GTS2024010234F01 Authorized Signature: Robinson Luo Laboratory Manager This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Page 1 of 38 TEST REPORT Applicant: ShenZhen FLYSKY Technology Co.,Ltd Address of Applicant: 16F, Huafeng Building, No. 6006 Shennan Road, Futian District, Shenzhen, Guangdong, China Manufacturer: ShenZhen FLYSKY Technology Co.,Ltd Address of Manufacturer: 16F, Huafeng Building, No. 6006 Shennan Road, Futian District, Shenzhen, Guangdong, China Factory: Dongguan Flysky RC Model technology Co.,Ltd Address of Factory: West building 3, HuangjinyuanInd Park, Qiaoli North Gate, Changping Town, Dongguan, China Equipment Under Test (EUT) Product Name: 11-CHANNEL RECEIVER Model No.: FS-R11P-BT-BS Trade Mark: FLYSKY FCC ID: 2A2UNR11P02 Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 Date of sample receipt: January 17, 2024 Date of Test: January 18, 2024-March 06, 2024 Date of report issued: March 06, 2024 Test Result : PASS * * In the configuration tested, the EUT complied with the standards specified above. Report No.: GTS2024010234F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 38 2 Version Version No. Date Description 00 March 06, 2024 Original Prepared By: Date: March 06, 2024 Project Engineer Check By: Date: March 06, 2024 Reviewer Report No.: GTS2024010234F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 38 3 Contents Page 1 COVER PAGE ................................................................................................................................................ 1 2 VERSION ........................................................................................................................................................ 2 3 CONTENTS .................................................................................................................................................... 3 4 TEST SUMMARY ........................................................................................................................................... 4 4.1 MEASUREMENT UNCERTAINTY .................................................................................................................. 4 5 GENERAL INFORMATION ............................................................................................................................ 5 5.1 GENERAL DESCRIPTION OF EUT ............................................................................................................... 5 5.2 TEST MODE .............................................................................................................................................. 7 5.3 TEST FACILITY .......................................................................................................................................... 7 5.4 TEST LOCATION ....................................................................................................................................... 7 5.5 DESCRIPTION OF SUPPORT UNITS ............................................................................................................. 7 5.6 DEVIATION FROM STANDARDS ................................................................................................................... 7 5.7 ABNORMALITIES FROM STANDARD CONDITIONS ......................................................................................... 7 5.8 ADDITIONAL INSTRUCTIONS ....................................................................................................................... 7 6 TEST INSTRUMENTS LIST ........................................................................................................................... 8 7 TEST RESULTS AND MEASUREMENT DATA .......................................................................................... 10 7.1 ANTENNA REQUIREMENT ......................................................................................................................... 10 7.2 CONDUCTED EMISSIONS ......................................................................................................................... 11 7.3 CONDUCTED PEAK OUTPUT POWER ........................................................................................................ 14 7.4 20DB EMISSION BANDWIDTH .................................................................................................................. 15 7.5 CARRIER FREQUENCIES SEPARATION ...................................................................................................... 16 7.6 HOPPING CHANNEL NUMBER .................................................................................................................. 17 7.7 DWELL TIME ........................................................................................................................................... 18 7.8 SPURIOUS EMISSION IN NON-RESTRICTED & RESTRICTED BANDS ............................................................. 19 7.8.1 Conducted Emission Method ........................................................................................................... 19 7.8.2 Radiated Emission Method .............................................................................................................. 20 8 TEST SETUP PHOTO .................…

Text truncated - open the document above for the full version.

Test Report

Report No.: GTS2024010234F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 1 of 20 1. Bandwidth 1.1 OBW 1.1.1 Test Result Mode TX Type Frequency (MHz) ANT 99% Occupied Bandwidth (MHz) Verdict Result Limit GFSK SISO 2408 1 0.563 / Pass 2440 1 0.561 / Pass 2475 1 0.561 / Pass Report No.: GTS2024010234F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 20 1.1.2 Test Graph GFSK_LCH_2408MHz_Ant1_NTNV GFSK_MCH_2440MHz_Ant1_NTNV Report No.: GTS2024010234F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 20 GFSK_HCH_2475MHz_Ant1_NTNV Report No.: GTS2024010234F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 20 1.2 20dB BW 1.2.1 Test Result Mode TX Type Frequency (MHz) ANT 20dB Bandwidth (MHz) Verdict Result Limit GFSK SISO 2408 1 0.588 / Pass 2440 1 0.591 / Pass 2475 1 0.589 / Pass Report No.: GTS2024010234F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 5 of 20 1.2.2 Test Graph GFSK_LCH_2408MHz_Ant1_NTNV GFSK_MCH_2440MHz_Ant1_NTNV Report No.: GTS2024010234F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 6 of 20 GFSK_HCH_2475MHz_Ant1_NTNV Report No.: GTS2024010234F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 7 of 20 2. Maximum Conducted Output Power 2.1 Test Result Mode TX Type Frequency (MHz) Maximum Peak Conducted Output Power (dBm) Verdict ANT1 Limit GFSK SISO 2408 5.62 <=20.97 Pass 2440 6.27 <=20.97 Pass 2475 2.99 <=20.97 Pass Report No.: GTS2024010234F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 8 of 20 2.2 Test Graph GFSK_LCH_2408MHz_Ant1_NTNV GFSK_MCH_2440MHz_Ant1_NTNV Report No.: GTS2024010234F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 9 of 20 GFSK_HCH_2475MHz_Ant1_NTNV Report No.: GTS2024010234F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 10 of 20 3. Carrier Frequency Separation 3.1 Test Result Ant1 Mode TX Type Frequency (MHz) Channel Separation (MHz) 20dB Bandwidth (MHz) Limit (MHz) Verdict GFSK SISO HOPP 3.494 0.591 >=0.591 Pass 3.2 Test Graph GFSK_HOPP_Ant1_NTNV Report No.: GTS2024010234F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 11 of 20 4. Number of Hopping Frequencies 4.1 Test Result Mode TX Type Frequency (MHz) Num of Hopping Frequencies Verdict ANT1 Limit GFSK SISO HOPP 16 >=15 Pass 4.2 Test Graph GFSK_HOPP_Ant1_NTNV Report No.: GTS2024010234F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 12 of 20 5. Time of Occupancy (Dwell Time) 5.1 Test Result Ant1 Mode TX Type Frequency (MHz) Duration of Single Pulse (ms) Observation Period (s) Num of Pulse in Observation Period Dwell Time (ms) Limit (ms) Verdict GFSK SISO HOPP 0.776 6.400 9 6.984 <=400 Pass 5.2 Test Graph GFSK_HOPP_Ant1_NTNV GFSK_HOPP_Ant1_NTNV Report No.: GTS2024010234F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 13 of 20 6. Unwanted Emissions In Non-restricted Frequency Bands 6.1 Ref 6.1.1 Test Result Mode TX Type Frequency (MHz) ANT Level of Reference (dBm) GFSK SISO 2408 1 5.49 2440 1 6.14 2475 1 2.86 Note1: Refer to FCC Part 15.247 (d) and ANSI C63.10-2013, the channel contains the maximum PSD level was used to establish the reference level. Report No.: GTS2024010234F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 14 of 20 6.1.2 Tes…

Text truncated - open the document above for the full version.

Test Report

深圳市德威玛通讯设备有限公司 2 1.目的 objective 对于深圳市德威玛通讯设备有限公司出品的移动通信终端天线产品规格、测试方法 进行规范,避免因测试条件,方法的不同引起误差。 To standardize the product specifications and test methods of mobile communication terminal antenna produced by Shenzhen Devima Communication Equipment Co., LTD., to avoid errors caused by different test conditions and methods. 2.技术指标与实验设备technical index 2.1 技术指标technical index 产品电气性能指标 Electrical performance index of products 工作频率范围 operating frequency range 2400~2500MHz 驻波比 SWR 2400~2500MHz<5.0 天线增益 antenna gain 2400~2500MHz:-1.11dBi 辐射效率 radiant efficiency 2400~2500MHz>15% 阻抗 impedance 50ohm 产品材料说明 Product material Description 灰色1.13 同轴线100mm Gray 1.13 coaxial line 100mm 产品环境说明 Product Environment Description 工作温度 Operation Temperature - 30 ̊C ~ + 85 ̊C 储藏温度 Store Temperature - 30 ̊C ~ + 85 ̊C 深圳市德威玛通讯设备有限公司 3 3. 产品结构图 Product structure drawing 深圳市德威玛通讯设备有限公司 4 4. 产品实物图 Product picture 5.天线性能:(驻波图、增益、效率、方向图) Antenna performance:(standing wave, gain, efficiency, direction diagram) 深圳市德威玛通讯设备有限公司 5 深圳市德威玛通讯设备有限公司 6 深圳市德威玛通讯设备有限公司 7 6.包装方式 manner of packing 包装方式 manner of packing 包装材料 packing material 包装规格 packing size 包装数量 package quantity 备注 remark 包装 pack PE 袋 PE bag 85*120mm1000pcs 焊接处包气泡膜 The welding place is covered with bubble film

Test Setup Photos

Page 1 of 2 Test Model No.: FS‐R11P‐BT‐BS Radiated Emission Page 2 of 2 Conducted Emission

Contact Information

Applicant

Kyle Li(RD Manager)
[email protected]+86-0755-83282965Fax: +86-0755-83282965

Test Firm

Global United Technology Services Co. Ltd.Robinson Lo
[email protected]86-0-755-2779-8480Fax: 86-0-755-27798960

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.48 GHz4.24 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. End users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from ShenZhen FLYSKY Technology Co.,Ltd

2A2UNST1600

Automatic Frequency Hopping Digital System

Oct 13, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2A2UNGMR-C300

3-Channel Receiver

Oct 08, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Digital Proprotional Radio Control System - FCC ID 2A2UNMG11OO - ShenZhen FLYSKY Technology Co.,Ltd
2A2UNMG11OO

Digital Proprotional Radio Control System

Mar 26, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
6-CHANNEL RECEIVER - FCC ID 2A2UNR6D01 - ShenZhen FLYSKY Technology Co.,Ltd
2A2UNR6D01

6-CHANNEL RECEIVER

Feb 19, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Digital Proprotional Radio Control System - FCC ID 2A2UNMG110O - ShenZhen FLYSKY Technology Co.,Ltd
2A2UNMG110O

Digital Proprotional Radio Control System

Feb 19, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter