Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 14, 2026
Application Purpose
Original Equipment
Equipment Note
Royyt+ Pro S Smart Body Fat Scale
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Subject Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

ShenzhenSubjectTechnologyCo.,Ltd. 705,Building11,PhaseII,TiananYunguIndustrialPark,GangtouCommunity,Bantian Sub-District,LonggangDistrict,Shenzhen,China FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 Date :July14,2026 U.S.AgentDesignation {ShenzhenSubjectTechnologyCo.,Ltd.}acknowledgestheirconsentforthefollowingcontactlocatedinthe UnitedStatestoactastheiragentforserviceofprocessfortheequipmentforwhichauthorizationissought(FCC ID:2A2VUVFS766): NameandcompanyofU.S.agent:BridgeportAdvisoryLLC PhysicalU.S.addressofagent:3330W38THPL,CHICAGO,IL60632,UnitedStates FRNofU.S.agent:0037566148 EmailaddressofU.S.agent:[email protected] ContactNO.:(708)680-6688 BridgeportAdvisoryLLCacknowledgestheirobligationtoacceptserviceofprocessonbehalfof{Shenzhen SubjectTechnologyCo.,Ltd.}. {ShenzhenSubjectTechnologyCo.,Ltd.}withtheFRN[0031266000]acceptsitsobligationtomaintainan agentforserviceofprocessintheUnitedStatesfornolessthanoneyearaftereitherthegranteehas permanentlyterminatedallmarketingandimportationoftheapplicableequipmentwithintheU.S.,orthe conclusionofanyCommission-relatedadministrativeorjudicialproceedinginvolvingtheequipment,whicheveris later. Bysigningthisform,weconfirmtheaboveandthatweareawareoftheapplicationrequirementslistedunder§ 2.911(d)(7). TheinformationprovidedinthisletterisbasedonthereferencedrulepartsofTitle47oftheCFRaswellasKDB 986446D01. Anexpirationdateforthisletterdoesnotexist.IncasetheU.S.agentchanges,thegranteeisobligatedtonotify theFCCwithin30daysviathegrantingTCB. Sincerely, Signature YanfeiSun GeneralManager ShenzhenSubjectTechnologyCo.,Ltd. Signature MrYongLiu ManagingMember BridgeportAdvisoryLLC 4 8 _ [ m o d e l ] U S _ A g e n t _ 2 . 9 1 1 ( d ) ( 7 ) - U , V 0 5

Attestation Statements

Covered Equipment Attestation Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2A2VUVFS766 VFS766 We, Applicant Company Name: Shenzhen Subject Technology Co., Ltd. Address: 705, Building 11, Phase II, Tianan Yungu Industrial Park, Gangtou Community, Bantian Sub-District, Longgang District, Shenzhen, China Phone: +86-18129820148 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. This includes the cybersecurity and anti-virus software produced or provided by Kaspersky Lab, Inc. or any of ist successors and assignees. We certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2026-07-14 Signature Date Name / Title: Yanfei Sun / General Manager Company: Shenzhen Subject Technology Co., Ltd. Address: 705, Building 11, Phase II, Tianan Yungu Industrial Park, Gangtou Community, Bantian Sub-District, Longgang District, Shenzhen, China Phone: +86-18129820148 Fax: N/A E-Mail: [email protected]

Attestation Statements

Due Diligence Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern FCC ID Model name 2A2VUVFS766 VFS766 Pursuant to KDB 986446 D01 Covered Equipment Guidance the evaluation of the product above shows compliance for the following reasons: Compliance Evaluation process Results Inherent compliance The chipset(s) used is not capable of running the cybersecurity and/or anti-virus software The memory used does not allow the running the cybersecurity and/or anti-virus software The storage capacity does not allow the running the cybersecurity and/or anti-virus software The operating system used is not capable of running the cybersecurity and/or anti-virus software No inherent compliance Based on software bill of material Compliance Based on scan for running software on the device Based on filesystem scan for cybersecurity and/or anti-virus software The equipment for which authorization is sought complies with the rules and fulfils the requirements as detailed in the above mentioned KDB. Evaluation performed by Company Name: Shenzhen Huaxia Testing Technology Co., Ltd Contact Name: Yoyo Zhou Address: 1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua District, Shenzhen, China Phone: +86-755-26648642 Email: [email protected] Signature: Date: 2026-07-14

Cover Letter(s)

Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2A2VUVFS766 VFS766 For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Part List • the Tune up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2026-07-14 Signature Date Name / Title: Yanfei Sun / General Manager Company: Shenzhen Subject Technology Co., Ltd. Address: 705, Building 11, Phase II, Tianan Yungu Industrial Park, Gangtou Community, Bantian Sub-District, Longgang District, Shenzhen, China Phone: +86-18129820148 Fax: N/A E-Mail: [email protected]

External Photos

ReportNo.:CQASZ20260701373E Photographs-EUTConstructionalDetails FCC ID: 2A2VUVFS766 ReportNo.:CQASZ20260701373E ReportNo.:CQASZ20260701373E ReportNo.:CQASZ20260701373E

Internal Photos

ReportNo.:CQASZ20260701373E Photographs-EUTConstructionalDetails FCC ID: 2A2VUVFS766 ReportNo.:CQASZ20260701373E ReportNo.:CQASZ20260701373E Antenna

RF Exposure Info

SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD 102A,102B,Building2,ShanghenglangNewIndustrialZone,ShanghenglangCommunity, DalangStreet,LonghuaDistrict,Shenzhen,Guangdong,People’sRepublicofChina,518000 Telephone:+86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com ReportTemplateVersion:V06 ReportTemplateRevisionDate:2026-01-30 TESTREPORT Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthisreportreferonlytothe sample(s)tested.WithoutwrittenapprovalofCQA,thisreportcan’tbereproducedexceptinfull. ReportNo.: CQASZ20260701373E-02 Applicant:ShenzhenSubjectTechnologyCo.,Ltd AddressofApplicant:705,Building11,PhaseII,TiananYunguIndustrialPark,GangtouCommunity, BantianSub-District,LonggangDistrict,Shenzhen EquipmentUnderTest(EUT): EUTName:Royyt+ProSSmartBodyFatScale ModelNo.:VFS766 TestModelNo.:VFS766 BrandName: FCCID:2A2VUVFS766 Standards: 47CFRPart1.1307 47CFRPart1.1310 KDB447498D01GeneralRFExposureGuidancev06 DateofReceipt:2026-07-02 DateofTest: 2026-07-02to2026-07-09 DateofIssue:2026-07-14 TestResult:PASS TestedBy: (LewisZhou) ReviewedBy: (TimoLei) ApprovedBy: (JackAi) SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260701373E-02 Page: 2 of 6 1.Version RevisionHistoryOfReport ReportNo.Version Description IssueDate CQASZ20260701373E-02Rev.01 Initialreport 2026-07-14 SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260701373E-02 Page: 3 of 6 2.Contents 1.VERSION....................................................................................................................................................................................2 2.CONTENTS................................................................................................................................................................................3 3.GENERALINFORMATION....................................................................................................................................................4 4.CLIENTINFORMATION........................................................................................................................................................4 5.GENERALDESCRIPTIONOFEUT......................................................................................................................................4 RFEXPOSUREEVALUATION..................................................................................................................................................5 RFEXPOSURECOMPLIANCEREQUIREMENT.............................................................................................................................5 StandardRequirement........................................................................................................................................................5 Limits......................................................................................................................................................................................5 EUTRFExposure................................................................................................................................................................6 SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260701373E-02 Page: 4 of 6 3.GeneralInformation 4.ClientInformation Applicant: ShenzhenSubjectTechnologyCo.,Ltd AddressofApplicant: 705,Building11,PhaseII,TiananYunguIndustrialPark, GangtouCommunity,BantianSub-District,LonggangDistrict,Shenzhen Manufacturer: ShenzhenSubjectTechnologyCo.,Ltd AddressofManufacturer: 705,Building11,PhaseII,TiananYunguIndustrialPark, GangtouCommunity,BantianSub-District,LonggangDistrict,Shenzhen Factory: ShenzhenUniqueScalesCo.,Ltd. AddressofFactory: 301&601,No.22,HuanpingRoad,GaoqiaoCommunity,PingdiStreet, LonggangDistrict,Shenzhen 5.GeneralDescriptionofEUT ProductName:Royyt+ProSSmartBodyFatScale ModelNo.:VFS766 TestModelNo.:VFS766 TradeMark: SoftwareVersion: V005.005 HardwareVersion: V1.3 ModulationType: GFSK TransferRate: 1Mbps NumberofChannel: 40 AntennaType: PCBantenna AntennaGain: -0.35dBi ProductType: MobilePortable PowerSupply: Drybatterypowersupply4*AAAADC6V SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260701373E-02 Page: 5 of 6 RFExposureEvaluation RFExposureComplianceRequirement StandardRequirement AccordingtoKDB447498D01GeneralRFExposureGuidancev06 4.3.1.StandaloneSARtestexclusionconsiderations UnlessspecificallyrequiredbythepublishedRFexposureKDBprocedures,standalone1- gheadorbodyand10-gextremitySARevaluationforgeneralpopulationexposure conditions,bymeasurementornumericalsimulation,isnotrequiredwhenthe correspondingSARExclusionThresholdcondition,listedbelow,issatisfied. Limits The1-gand10-gSARtestexclusionthresholdsfor100MHzto6GHzattestseparation distances≤50mmaredeterminedby: [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparationdistance, mm)]·[√f(GHz)]≤3.0for1-gSARand≤7.5for10-gextremitySAR,where f(GHz)istheRFchanneltransmitfrequencyinGHz PoweranddistanceareroundedtothenearestmWandmmbeforecalculation17 Theresultisroundedtoonedecimalplaceforcomparison Thetestexclusionsareapplicableonlywhentheminimumtestseparationdistanceis≤50mm andfortransmissionfrequenciesbetween100MHzand6GHz.Whentheminimumtest separationdistanceis<5mm,adistanceof5mmisappliedtodetermineSARtestexclusion SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260701373E-02 Page: 6 of 6 EUTRFExposure 1)ForBLE MeasurementData Worstcase:GFSK TestChannel PeakOutputPower (dBm) Tuneuptolerance (dBm) Maximumtune-upPower (dBm)(mW) Lowest(2402MHz) -1.53-1.5±1-0.50.891 Middle(2440MHz) 0.160±111.259 Highest(2480MHz) -0.270±11 1.259 Worstcase:GFSK Channel MaximumtuneupPower (mW) Calculatedvalue Exclusion threshold Lowest (2402MHz) 0.891 0.276 3.0 Middle (2440MHz) 1.2590.393 Highest (2480MHz) 1.2590.397 Conclusion:thecalculatedvalue≤3.0,SARisexempted. Remark:TheMaxConductedPeakOutputPowerdatarefertoreportReportNo.:CQASZ20260701373E-01

Test Report

Professional RF R&D institutions Shenzhen Deweima Communication Equipment Co., Ltd Shenzhen R&D Center Laboratory Completion Date: May 31, 2026 Antenna Specifications Project Information 1 2 Project:CF693 Frequency band : BT(2.4GHz~ 2.5GHz) 3 Remarks 4 Customer Name:LEFU Test Instruments and Equipment Antenna Project Design and Debugging Instructions BT:2400~2500MH Operating Frequency Band z Test Engineer DWM- V1. Version 0 Overall Machine DiagramAntenna Remarks Description 1. BT antenna type: IFA antenna 2. BT antenna matching circuit Antenna Environmental Treatment Debug and test according to the original state of the machine without adding other auxiliary materials. Instructions for BT Antenna Matching Circuit ElementValueVender E1(0402) E2(0402 NC ) E3(0402 1NH ) E4(0402 0.5PF ) BT Technology Parameters BT Frequency Range: 2400MHz-2500MHz BT antenna type: PCB Antenna Model: NA Company:www.lefu.cc Address:3rd Floor, 6th Floor, Building A, No. 22 Huanping Road, Gaoqiao Community, Pingdi Sub-district, Longgang District, Shenzhen City, Guangdong Province Operating Humidity: 85% R.H.MAX Temperature Rating: 5°C~+40°C BT antenna SWR & Smith parameters BT antenna gain and efficiency Gain&Efficiency GainFrequency (MHz)(dBi) MinGain (dBi) Efficiency (dB) 2400.0 Efficiency (%) 0-0.72-30.23 -4.7235.73 2410.00-0.51-31.26 -4.8935.43 2420.00-0.35-32.90-4.5435.16 2430.00-0.68-30.21 -4.6534.28 2440.00-0.58-29.83 -4.934.36 2450.00-0.82-28.78 -4.9234.21 2460.00-0.73-32.73 -5.132.9 2470.00-0.58-32.08 -4.7533.95 2480.00-0.81-30.20-4.8232.96 2490.00-0.69-27.87-5.0731.12 2500.00-0.71-25.41-5.1430.62 BT antenna pattern (2400MHz) BT antenna pattern(2450MHz) BT antenna pattern(2500MHz) Shenzhen Deweima Communication Equipment Co., Ltd Addresss: Room 301, 3rd Floor, Building 1, Youyi Industrial Zone, Area 23, Xin'an Street, Bao'an District, Shenzhen, China

Test Report

CQASZ20260701373E-01 AppendixA:DTSBandwidth TestResult TestModeFreq(MHz) DTSBW [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict BLE_1M 24020.662401.692402.360.5PASS 24400.672439.692440.360.5PASS 24800.672479.682480.360.5PASS TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 AppendixB:OccupiedChannelBandwidth TestResult TestModeAntennaFreq(MHz) OCB[MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict BLE_1MAnt1 24021.0832401.47652402.5594------ 24401.0672439.48452440.5514------ 24801.0512479.49252480.5435------ TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 AppendixC:Maximumconductedoutputpower TestResultPeak TestModeFreq(MHz) Conducted Peak Powert[dBm] Conducted Limit[dBm] EIRP[dBm] EIRP Limit[dBm] Verdict BLE_1M 2402-1.53≤30-1.53≤36PASS 24400.16≤300.16≤36PASS 2480-0.27≤30-0.27≤36PASS TestGraphsPeak BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 AppendixD:Maximumpowerspectraldensity TestResult TestModeFreq(MHz)Result[dBm/3kHz]Limit[dBm/3kHz]Verdict BLE_1M 2402-18.02≤8.00PASS 2440-16.40≤8.00PASS 2480-17.30≤8.00PASS TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 AppendixF:Bandedgemeasurements TestResult TestModeChNameFreq(MHz)RefLevel[dBm]Result[dBm]Limit[dBm]Verdict BLE_1M Low2402-2.59-43.37≤-22.59PASS High2480-1.54-43.2≤-21.54PASS TestGraphs BLE_1M_Ant1_Low_2402 BLE_1M_Ant1_High_2480 AppendixG:ConductedSpuriousEmission TestResult TestModeFreq(MHz) FreqRange [MHz] RefLevel [dBm] Result[dBm]Limit[dBm]Verdict BLE_1M 2402 Reference-2.79-2.79---PASS 30~1000-2.79-51.68≤-22.79PASS 1000~26500-2.79-48.69≤-22.79PASS 2440 Reference-0.37-0.37---PASS 30~1000-0.37-50.07≤-20.37PASS 1000~26500-0.37-47.82≤-20.37PASS 2480 Reference-1.10-1.10---PASS 30~1000-1.10-52.02≤-21.1PASS 1000~26500-1.10-47.19≤-21.1PASS TestGraphs BLE_1M_Ant1_2402_0~Reference BLE_1M_Ant1_2402_30~1000 BLE_1M_Ant1_2402_1000~26500 BLE_1M_Ant1_2440_0~Reference BLE_1M_Ant1_2440_30~1000 BLE_1M_Ant1_2440_1000~26500 BLE_1M_Ant1_2480_0~Reference BLE_1M_Ant1_2480_30~1000 BLE_1M_Ant1_2480_1000~26500 AppendixH:DutyCycle TestResult TestModeFreq(MHz) ONTime [ms] Period [ms] XDC [%] xFactor LimitVerdict BLE_1M 24022.142.500.856085.600.68------ 24402.142.500.856085.600.68------ 24802.142.500.856085.600.68------ TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480

Test Report

SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD 102A,102B,Building2,ShanghenglangNewIndustrialZone,ShanghenglangCommunity, DalangStreet,LonghuaDistrict,Shenzhen,Guangdong,People’sRepublicofChina,518000 Telephone:+86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com ReportTemplateVersion:V06 ReportTemplateRevisionDate:2026-01-30 TestReport Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthisreportreferonly tothesample(s)tested.WithoutwrittenapprovalofCQA,thisreportcan’tbereproducedexceptinfull. ReportNo.:CQASZ20260701373E-01 Applicant:ShenzhenSubjectTechnologyCo.,Ltd AddressofApplicant:705,Building11,PhaseII,TiananYunguIndustrialPark,GangtouCommunity, BantianSub-District,LonggangDistrict,Shenzhen EquipmentUnderTest(EUT): Product:Royyt+ProSSmartBodyFatScale ModelNo.:VFS766 TestModelNo.:VFS766 BrandName: FCCID:2A2VUVFS766 Standards:47CFRPart15,SubpartC KDB558074D0115.247MeasGuidancev05r02 ANSIC63.10:2020 DateofReceipt:2026-07-02 DateofTest:2026-07-02to2026-07-09 DateofIssue:2026-07-14 TestResult:PASS* *Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove. TestedBy: (LewisZhou) ReviewedBy: (TimoLei) ApprovedBy: (JackAi) SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260701373E-01 Page: 2 of 26 1Version RevisionHistoryOfReport ReportNo.Version Description IssueDate CQASZ20260701373E-01Rev.01Initialreport2026-07-14 SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260701373E-01 Page: 3 of 26 2TestSummary TestItemTestRequirementTestmethodResult AntennaRequirement 47CFRPart15,SubpartCSection 15.203/15.247(c) ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS ACPowerLine Conducted Emission 47CFRPart15,SubpartCSection 15.207 ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 N/A ConductedPeakOutput Power 47CFRPart15,SubpartCSection 15.247(b)(3) ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS 6dBOccupied Bandwidth 47CFRPart15,SubpartCSection 15.247(a)(2) ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS PowerSpectralDensity 47CFRPart15,SubpartCSection 15.247(e) ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS Band-edgeforRF ConductedEmissions 47CFRPart15,SubpartCSection 15.247(d) ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS RFConductedSpurious Emissions 47CFRPart15,SubpartCSection 15.247(d) ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS RadiatedSpurious Emissions 47CFRPart15,SubpartCSection 15.205/15.209 ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS Restrictedbandsaround fundamentalfrequency (RadiatedEmission) 47CFRPart15,SubpartCSection 15.205/15.209 ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260701373E-01 Page: 4 of 26 3Contents Page 1VERSION..........................................................................................................................................................................2 2TESTSUMMARY............................................................................................................................................................3 3CONTENTS......................................................................................................................................................................4 4GENERALINFORMATION...........................................................................................................................................5 4.1CLIENTINFORMATION.................................................................................................................................................5 4.2GENERALDESCRIPTIONOFEUT.................................................................................................................................5 4.3ADDITIONALINSTRUCTIONS........................................................................................................................................7 4.4TESTENVIRONMENT...................................................................................................................................................8 4.5DESCRIPTIONOFSUPPORTUNITS...............................................................................................................................8 4.6TESTCONFIGURATION................................................................................................................................................8 4.7STATEMENTOFTHEMEASUREMENTUNCERTAINTY....................................................................................................9 4.8TESTLOCATION........................................................................................................................................................10 4.9TESTFACILITY..........................................................................................................................................................10 4.10DEVIATIONFROMSTANDARDS................................................................................................................................10 4.11OTHERINFORMATIONREQUESTEDBYTHECUSTOMER..........................................................................................10 4.12EQUIPMENTLIST.....................................................................................................................................................11 5TESTRESULTSANDMEASUREMENTDATA.....................................................................................................12 5.1ANTENNAREQUIREMENT..........................................................................................................................................12 5.2CONDUCTEDPEAKOUTPUTPOWER..........................................................................................................................13 5.36DBOCCUPYBANDWIDTH.................................…

Text truncated - open the document above for the full version.

Test Setup Photos

ReportNo.:CQASZ20260701373E 1Photographs-EUTTestSetup 1.1RadiatedSpuriousEmission 9kHz~30MHz: 30MHz~1GHz: FCC ID: 2A2VUVFS766 ReportNo.:CQASZ20260701373E Above1GHz: 1.2 RFConductedmeasurement

Contact Information

Applicant

Yanfei Sun(General Manager)
[email protected]Fax: N/A

Technical Contact

Bridgeport Advisory LLCYong Liu
[email protected]

3330 W 38TH PL, CHICAGO, · Illinois, 60632 · United States

Test Firm

Shenzhen Huaxia Testing Technology Co., LtdJack Ai
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is maximum peak conducted output power. This filing meets the SAR threshold exclusion set forth in KDB 447498 and therefore can be used in mobile/portable configurations. The antenna used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures.