Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
L The sync box only supports 4K/30P sources. If you need to use it to display higher-level sources, you can use a Selector Switch Boxes to convert it. The sync box doesn't support two or more phones'connection meanwhile. You can reset to restore to the factory setting to start again if there is any problem or failure in connection. The box can be controlled via voice control after logging in the account of the voice assistant. We recommend to keep the item in a dry and ventilated place and get away from the wet or humid situations. It's a normal case the box gets heated after plugging and working for several hours. Please plug it out in time if not using for a period. l FCC WARNING This device complies with part 15 of the FCC Rules. Operation is subject to the follow ing two conditions : (1) this device may not cause harmful interference, and (2) this device must accept any interference received, inc luding interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residentia l installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or televis ion reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technic ian for help. To maintain compliance with FCC’s RF Exposure guidelines, This equipment should be insta lled and operated with minimum distance between 20cm the radiator your body: Use only the supplied antenna.
Glowworm(Shenzhen)LightingTechnologyCo.,Ltd ModelDifference Productdescription:LEDlightcontrolbox Modelname:LDD11 LDD11-5V,LDD11-12V,LDD11-24V TradeName:N/A FCCID:2A2XC-LDD11 AllthemodelarethesamecircuitandRFmodule,onlyformodelname. Regards Sincerely Client’ssignature: Client’sname/title:Buck Contactinformation/address:1216,EastBuilding4,SEGScienceandTechnology Park,ZhenxingRoad,FutianDistrict,Shenzhen,Guangdong,China
C5266091_X8_Ed.1 1/1 LetterofAuthorization <Glowworm(Shenzhen)LightingTechnologyCo.,Ltd> Company:Glowworm(Shenzhen)LightingTechnologyCo.,Ltd Address:No.19,XitanIndustrialArea,FuanCity,NingdeCity,Fujian Province,China ProductName:LEDlightcontrolbox ModelNumber:LDD11 LDD11-5V,LDD11-12V,LDD11-24V FCCIdentifier:2A2XC-LDD11 WeauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdelCarme,s/n, 08193Bellaterra,Spain,toactonourbehalfonallmattersconcerningthe abovenamedequipment. AnyindividualwithinLGAITechnologicalCenterS.A.isauthorizedtoactonour behalfandtakeactionontheapplication. WedeclarethatauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdel Carme,s/n,08193Bellaterra,Spain,isallowedtoforwardallinformation relatedtotheapprovalprojecttotheFederalCommunicationCommissionand todiscussanyissuesconcerningtheapprovalapplication.Anyandallacts carriedoutbyLGAITechnologicalCenterS.A.onourbehalfshallhavethe sameeffectasactsofourown. Name:BuckDate:2021-08-19 Title:N/A Signatureofapplicant:
C5266091_X10_Ed.1 1/1 <Glowworm(Shenzhen)LightingTechnologyCo.,Ltd> OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:2021-08-19 Subject:RequestforConfidentiality FCCID:2A2XC-LDD11 ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality IDLabel/LocationNoNo AttestationStatementNoNo ExternalPhotosNo BlockDiagram Schematics TestReportNoNo TestSetupPhotosNo User’sManual InternalPhotos PartsList/TuneUp RFExposureInfo OperationalDescription CoverLetter(s)NoNo SDRSoftware/SecurityInfoNo Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. Sincerely, Signature: Name:Buck Title: N/A
EUTPHOTO(ExternalPhotos)
Labelandlabellocation LED light control box FCC ID:2A2XC-LDD11
EUTPHOTO(InternalPhotos) BT/WIFITAN
FCCID:2A2XC-LDD11 RFExposureEvaluation Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactofhumanexposure toradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE) Frequencyrange (MHz) Electricfield strength (V/m) Magneticfieldstrength (A/m) Powerdensity (mW/cm 2 ) Averagingtime (minutes) (A)LimitsforOccupational/ControlledExposures 0.3–3.06141.63*(100)6 3.0–301842/f4.89/f*(900/f 2 )6 30–30061.40.1631.06 300–1500f/3006 1500–100,00056 (B)LimitsforGeneralPopulation/UncontrolledExposure 0.3–1.346141.63*(100)30 1.34–30824/f2.19/f*(180/f 2 )30 30–30027.50.0730.230 300–1500f/150030 1500–100,0001.030 f=frequencyinMHz Friistransmissionformula:Pd=(Pout*G)/(4*pi*r 2 ) Where Pd=powerdensityinmW/cm 2 ,Pout=outputpowertoantennainmW; G=gainofantennainlinearscale,Pi=3.1416; R=distancebetweenobservationpointandcenteroftheradiatorincm PdidthelimitofMPE,1mW/cm 2 .Ifweknowthemaximumgainoftheantennaandthetotalpowerinputto theantenna,throughthecalculation,wewillknowthedistancerwheretheMPElimitisreached. TestProcedure SoftwareprovidedbyclientenabledtheEUTtotransmitandreceivedataatlowest,middleandhighest channelindividually. TestResultofRFExposureEvaluation 2.4GWIFImode Channel Outputpower toantenna (dBm) Outputpowerto antenna(mW) PowerDensityat R=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result 802.11b12.39117.34 0.00344 1.0PASS 802.11g11.46814.02 0.00278 1.0PASS 802.11n(HT20)10.91412.34 0.00245 1.0PASS 802.11n(HT40)8.9297.81 0.00155 1.0PASS 2.4GBTBLEmode Channel Outputpower toantenna (dBm) Outputpowerto antenna(mW) PowerDensityat R=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result GFSK-0.0430.990 0.000196 1.0PASS Remark:antennagain=0dBi
ProjectNo.:ZKT-2107263677E Page 1 of 39 FCCTESTREPORT FCCID:2A2XC-LDD11 ReportNumber.....................................:ZKT-2107263677E DateofTest ....................................................... :Aug.01,2021toAug.10,2021 Dateofissue.........................................:Aug.10,2021 Totalnumberofpages..........................39 TestResult..........................................: PASS TestingLaboratory. .............................. : ShenzhenZKTTechnologyCo.,Ltd. Address...............................................: 1/F,No.101,BuildingB,No.6,TangweiCommunityIndustrial Avenue,FuhaiStreet,Bao'anDistrict,Shenzhen,China Applicant'sname................................:Glowworm(Shenzhen)LightingTechnologyCo.,Ltd Address...............................................: 702,building23,LonghuaDistrictScienceandtechnology innovationcenter,minfanRoad,Minzhistreet,LonghuaDistrict, Shenzhen,Guangdong,China Manufacturer'sname.........................:Glowworm(Shenzhen)LightingTechnologyCo.,Ltd Address...............................................: 702,building23,LonghuaDistrictScienceandtechnology innovationcenter,minfanRoad,Minzhistreet,LonghuaDistrict, Shenzhen,Guangdong,China Testspecification: Standard................................................:FCCCFRTitle47Part15SubpartCSection15.247 Testprocedure.....................................: KDB558074D0115.247MeasGuidancev05r02 ANSIC63.10:2013 Non-standardtestmethod................:N/A TestReportFormNo. ....................... : TRF-EL-111_V0 TestReportForm(s)Originator.....: ZKTTesting MasterTRF........................................: Dated:2020-01-06 ThisdevicedescribedabovehasbeentestedbyZKT,andthetestresultsshowthattheequipmentunder test(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofZKT,thisdocumentmay bealteredorrevisedbyZKT,personalonly,andshallbenotedintherevisionofthedocument. Productname.......................................:LEDlightcontrolbox Trademark ........................................... : N/A Model/Typereference.........................: LDD11 LDD11-5V,LDD11-12V,LDD11-24V Ratings .................................................. :Input:120V/60Hz ProjectNo.:ZKT-2107263677E Page 2 of 39 Testingprocedureandtestinglocation: TestingLaboratory ....................................... :ShenzhenZKTTechnologyCo.,Ltd. Address............................................................:1/F,No.101,BuildingB,No.6,TangweiCommunity IndustrialAvenue,FuhaiStreet,Bao'anDistrict, Shenzhen,China AlenHe Testedby(name+signature) ....................... : JoeLiu Reviewer(name+signature) ....................... : LakeXie Approved(name+signature) ....................... : ProjectNo.:ZKT-2107263677E Page 3 of 39 TableofContents Page 1.VERSION5 2.SUMMARYOFTESTRESULTS6 2.1TESTFACILITY7 2.2MEASUREMENTUNCERTAINTY7 3.GENERALINFORMATION8 3.1GENERALDESCRIPTIONOFEUT8 3.2DESCRIPTIONOFTESTMODES9 3.3BLOCKDIGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED9 3.4DESCRIPTIONOFSUPPORTUNITS(CONDUCTEDMODE)9 3.5EQUIPMENTSLISTFORALLTESTITEMS11 4.EMCEMISSIONTEST12 4.1CONDUCTEDEMISSIONMEASUREMENT12 4.1.1POWERLINECONDUCTEDEMISSIONLIMITS12 4.1.2TESTPROCEDURE12 4.1.3DEVIATIONFROMTESTSTANDARD12 4.1.4TESTSETUP13 4.1.5EUTOPERATINGCONDITIONS13 4.1.6TESTRESULTS13 4.2RADIATEDEMISSIONMEASUREMENT16 4.2.1RADIATEDEMISSIONLIMITS16 4.2.2TESTPROCEDURE17 4.2.3DEVIATIONFROMTESTSTANDARD17 4.2.4TESTSETUP17 4.2.5EUTOPERATINGCONDITIONS18 5.RADIATEDBANDEMISSIONMEASUREMENT23 5.1TESTREQUIREMENT:23 5.2TESTPROCEDURE23 5.3DEVIATIONFROMTESTSTANDARD23 5.4TESTSETUP24 5.5EUTOPERATINGCONDITIONS24 5.6TESTRESULT25 6.POWERSPECTRALDENSITYTEST26 6.1APPLIEDPROCEDURES/LIMIT26 6.2TESTPROCEDURE26 6.3DEVIATIONFROMSTANDARD26 6.4TESTSETUP26 ProjectNo.:ZKT-2107263677E Page 4 of 39 TableofContentsPage 6.5EUTOPERATIONCONDITIONS26 6.6TESTRESULTS27 7.CHANNELBANDWIDTH29 7.1APPLIEDPROCEDURES/LIMIT29 7.2TESTPROCEDURE29 7.3DEVIATIONFROMSTANDARD29 7.4TESTSETUP29 7.5EUTOPERATIONCONDITIONS29 7.6TESTRESULTS30 8.PEAKOUTPUTPOWERTEST32 8.1APPLIEDPROCEDURES/LIMIT32 8.2TESTPROCEDURE32 8.3DEVIATIONFROMSTANDARD32 8.4TESTSETUP32 8.5EUTOPERATIONCONDITIONS32 8.6TESTRESULTS33 9.CONDUCTEDBANDEDGEANDSPURIOUSEMISSION34 9.1APPLICABLESTANDARD34 9.2TESTPROCEDURE34 9.3DEVIATIONFROMSTANDARD34 9.4TESTSETUP34 9.5EUTOPERATIONCONDITIONS34 10.ANTENNAREQUIREMENT38 11.TESTSETUPPHOTO39 12.EUTCONSTRUCTIONALDETAILS39 ProjectNo.:ZKT-2107263677E Page 5 of 39 1.VERSION ReportNo.VersionDescriptionApproved ZKT-2107263677ERev.01InitialissueofreportAug.10,2021 ProjectNo.:ZKT-2107263677E Page 6 of 39 2.SUMMARYOFTESTRESULTS Testproceduresaccordingtothetechnicalstandards: FCCPart15(15.247),SubpartC Standard Section TestItemJudgmentRemark FCCpart15.203/15.247 (c) AntennarequirementPASS FCCpart15.207ACPowerLineConductedEmissionN/A FCCpart15.247(b)(3)ConductedPeakOutputPowerPASS FCCpart15.247(a)(2)ChannelBandwidth&99%OCBPASS FCCpart15.247(e)PowerSpectralDensityPASS FCCpart15.247(d)BandEdgePASS FCCpart15.205/15.209SpuriousEmissionPASS NOTE: (1)”N/A”denotestestisnotapplicableinthisTestReport ProjectNo.:ZKT-2107263677E Page 7 of 39 2.1TESTFACILITY ShenzhenZKTTechnologyCo.,Ltd. Add.:1/F,No.101,BuildingB,No.6,TangweiCommunityIndustrialAvenue,FuhaiStreet,Bao'an District,Shenzhen,China FCCTestFirmRegistrationNumber:692225 DesignationNumber:CN1299 ICRegisteredNo.:27033 2.2MEASUREMENTUNCERTAINTY Thereporteduncertaintyofmeasurementy±U,whereexpendeduncertaintyUisbasedonastandard uncertaintymultipliedbyacoveragefactorofk=2,providingalevelofconfidenceofapproximately95 %。 No.ItemUncertainty 1ConductedEmissionTest±1.38dB 2RFpowerconducted±0.16dB 3Spuriousemissionsconducted±0.21dB 4Allemissionsradiated(<1G)±4.68dB 5Allemissionsradiated(>1G)±4.89dB 6Temperature±0.5°C 7Humidity±2% ProjectNo.:ZKT-2107263677E Page 8 of 39 3.GENERALINFORMATION 3.1GENERALDESCRIPTIONOFEUT ProductName: LEDlightcontrolbox ModelNo.: LDD11 LDD11-5V,LDD11-12V,LDD11-24V ModelDifferen…
Text truncated - open the document above for the full version.
ProjectNo.:ZKT-2107263677E Page 1 of 56 FCCTESTREPORT FCCID:2A2XC-LDD11 ReportNumber...................................:ZKT-2107263677E DateofTest.......................................................:Aug.01,2021toAug.10,2021 Dateofissue ......................................... :Aug.10,2021 Totalnumberofpages .......................... 56 TestResult............................................: PASS TestingLaboratory. ........................... : ShenzhenZKTTechnologyCo.,Ltd. Address...............................................: 1/F,No.101,BuildingB,No.6,TangweiCommunityIndustrial Avenue,FuhaiStreet,Bao'anDistrict,Shenzhen,China Applicant'sname.............................:Glowworm(Shenzhen)LightingTechnologyCo.,Ltd Address...............................................: 702,building23,LonghuaDistrictScienceandtechnology innovationcenter,minfanRoad,Minzhistreet,LonghuaDistrict, Shenzhen,Guangdong,China Manufacturer'sname......................:Glowworm(Shenzhen)LightingTechnologyCo.,Ltd Address...............................................: 702,building23,LonghuaDistrictScienceandtechnology innovationcenter,minfanRoad,Minzhistreet,LonghuaDistrict, Shenzhen,Guangdong,China Testspecification: Standard ................................................ : FCCCFRTitle47Part15SubpartCSection15.247 ANSIC63.10:2013 Testprocedure ..................................... : / Non-standardtestmethod................:N/A TestReportFormNo........................: TRF-EL-110_V0 TestReportForm(s)Originator.....: ZKTTesting MasterTRF ........................................ : Dated:2020-01-06 ThisdevicedescribedabovehasbeentestedbyZKT,andthetestresultsshowthattheequipmentunder test(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofZKT,thisdocumentmay bealteredorrevisedbyZKT,personalonly,andshallbenotedintherevisionofthedocument. Productname.....................................:LEDlightcontrolbox Trademark ........................................... : N/A Model/Typereference.........................:LDD11 LDD11-5V,LDD11-12V,LDD11-24V Ratings..................................................:Input:120V/60Hz ProjectNo.:ZKT-2107263677E Page 2 of 56 Testingprocedureandtestinglocation: TestingLaboratory.......................................:ShenzhenZKTTechnologyCo.,Ltd. Address ............................................................ :1/F,No.101,BuildingB,No.6,TangweiCommunity IndustrialAvenue,FuhaiStreet,Bao'anDistrict, Shenzhen,China AlenHe Testedby(name+signature).......................: JoeLiu Reviewer(name+signature).......................: LakeXie Approved(name+signature) ....................... : ProjectNo.:ZKT-2107263677E Page 3 of 56 TableofContents Page 1.VERSION5 2.SUMMARYOFTESTRESULTS6 2.1TESTFACILITY7 2.2MEASUREMENTUNCERTAINTY7 3.GENERALINFORMATION8 3.1GENERALDESCRIPTIONOFEUT8 3.2DESCRIPTIONOFTESTMODES9 3.3BLOCKDIGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED9 3.4DESCRIPTIONOFSUPPORTUNITS(CONDUCTEDMODE)10 3.5EQUIPMENTSLISTFORALLTESTITEMS11 4.EMCEMISSIONTEST12 4.1CONDUCTEDEMISSIONMEASUREMENT12 4.1.1POWERLINECONDUCTEDEMISSIONLIMITS12 4.1.2TESTPROCEDURE12 4.1.3DEVIATIONFROMTESTSTANDARD12 4.1.4TESTSETUP13 4.1.5EUTOPERATINGCONDITIONS13 4.1.6TESTRESULT14 4.2RADIATEDEMISSIONMEASUREMENT16 4.2.1RADIATEDEMISSIONLIMITS16 4.2.2TESTPROCEDURE16 4.2.3DEVIATIONFROMTESTSTANDARD17 4.2.4TESTSETUP17 4.2.5EUTOPERATINGCONDITIONS18 4.2.6TESTRESULTS18 5.RADIATEDBANDEMISSIONMEASUREMENT29 5.1TESTREQUIREMENT:29 5.2TESTPROCEDURE29 5.3DEVIATIONFROMTESTSTANDARD29 5.4TESTSETUP30 5.5EUTOPERATINGCONDITIONS30 5.6TESTRESULT31 6.POWERSPECTRALDENSITYTEST33 6.1APPLIEDPROCEDURES/LIMIT33 6.2TESTPROCEDURE33 6.3DEVIATIONFROMSTANDARD33 6.4TESTSETUP33 6.5EUTOPERATIONCONDITIONS33 ProjectNo.:ZKT-2107263677E Page 4 of 56 6.6TESTRESULT34 7.CHANNELBANDWIDTH&99%OCCUPYBANDWIDTH42 7.1APPLIEDPROCEDURES/LIMIT42 7.2TESTPROCEDURE42 7.3DEVIATIONFROMSTANDARD42 7.4TESTSETUP42 7.5EUTOPERATIONCONDITIONS42 7.6TESTRESULT43 8.PEAKOUTPUTPOWERTEST46 8.1APPLIEDPROCEDURES/LIMIT46 8.2TESTPROCEDURE46 8.3DEVIATIONFROMSTANDARD46 8.4TESTSETUP46 8.5EUTOPERATIONCONDITIONS46 8.6TESTRESULT47 9.CONDUCTEDBANDEDGEANDSPURIOUSEMISSION48 9.1APPLICABLESTANDARD48 9.2TESTPROCEDURE48 9.3DEVIATIONFROMSTANDARD48 9.4TESTSETUP48 9.5EUTOPERATIONCONDITIONS48 9.6TESTRESULTS48 10.ANTENNAREQUIREMENT55 11.TESTSETUPPHOTO56 12.EUTCONSTRUCTIONALDETAILS56 ProjectNo.:ZKT-2107263677E Page 5 of 56 1.VERSION ReportNo.VersionDescriptionApproved ZKT-2107263677ERev.01InitialissueofreportAug.10,2021 ProjectNo.:ZKT-2107263677E Page 6 of 56 2.SUMMARYOFTESTRESULTS Testproceduresaccordingtothetechnicalstandards: FCCPart15(15.247),SubpartC Standard Section TestItemResultRemark FCCpart15.203/15.247 (c) AntennarequirementPASS FCCpart15.207ACPowerLineConductedEmissionPASS FCCpart15.247(b)(3)ConductedPeakOutputPowerPASS FCCpart15.247(a)(2)ChannelBandwidth&99%OCBPASS FCCpart15.247(e)PowerSpectralDensityPASS FCCpart15.247(d)BandEdgePASS FCCpart15.205/15.209SpuriousEmissionPASS NOTE: (1)”N/A”denotestestisnotapplicableinthisTestReport ProjectNo.:ZKT-2107263677E Page 7 of 56 2.1TESTFACILITY ShenzhenZKTTechnologyCo.,Ltd. Add.:1/F,No.101,BuildingB,No.6,TangweiCommunityIndustrialAvenue,FuhaiStreet,Bao'an District,Shenzhen,China FCCTestFirmRegistrationNumber:692225 DesignationNumber:CN1299 ICRegisteredNo.:27033 2.2MEASUREMENTUNCERTAINTY Thereporteduncertaintyofmeasurementy±U,whereexpendeduncertaintyUisbasedonastandard uncertaintymultipliedbyacoveragefactorofk=2 , providingalevelofconfidenceofapproximately95 %。 No.ItemUncertainty 1ConductedEmissionTest±1.38dB 2RFpowerconducted±0.16dB 3Spuriousemissionsconducted±0.21dB 4Allemissionsradiated(<1G)±4.68dB 5Allemissionsradiated(>1G)±4.89dB 6Temperature±0.5°C 7Humidity±2% ProjectNo.:ZKT-2107263677E Page 8 of 56 3.GENERALINFORMATION 3.1GENERALDESCRIPTIONOFEUT ProductName: LEDlightcontrolbox ModelNo.: LDD11 LDD11-5V,LDD11-12V,LDD11-24V ModelDifferent.: N/A Seria…
Text truncated - open the document above for the full version.
ProjectNo.:ZKT-2107263677E Page 31 of 56 5.6TESTRESULT Polar (H/V) Frequenc y (MHz) Meter Reading (dBuV) Pre- amplifier (dB) Cable Loss (dB) Antenna Factor (dB/m) Emission level (dBuV/m) Limit (dBuV /m) Detec tor Type Result 802.11b LowChannel2412MHz H2390.0060.5330.224.8523.9859.1474.00PKPASS H2390.0052.3630.224.8523.9850.9754.00AVPASS H2400.0062.2630.224.8523.9860.8774.00PKPASS H2400.0052.3630.224.8523.9850.9754.00AVPASS V2390.0060.3830.224.8523.9858.9974.00PKPASS V2390.0052.2630.224.8523.9850.8754.00AVPASS V2400.0062.1130.224.8523.9860.7274.00PKPASS V2400.0052.3630.224.8523.9850.9754.00AVPASS HighChannel2462MHz H2483.5060.2230.224.8523.9858.8374.00PKPASS H2485.5051.2630.224.8523.9849.8754.00AVPASS H2483.5061.6930.224.8523.9860.3074.00PKPASS H2485.5052.1430.224.8523.9850.7554.00AVPASS V2483.5061.0330.224.8523.9859.6474.00PKPASS V2485.5052.6330.224.8523.9851.2454.00AVPASS V2483.5061.2230.224.8523.9859.8374.00PKPASS V2485.5052.2530.224.8523.9850.8654.00AVPASS 802.11g LowChannel2412MHz H2390.0060.0330.224.8523.9858.6474.00PKPASS H2390.0052.2630.224.8523.9850.8754.00AVPASS H2400.0062.0630.224.8523.9860.6774.00PKPASS H2400.0052.1630.224.8523.9850.7754.00AVPASS V2390.0060.2830.224.8523.9858.8974.00PKPASS V2390.0052.0630.224.8523.9850.6754.00AVPASS V2400.0062.0130.224.8523.9860.6274.00PKPASS V2400.0052.0630.224.8523.9850.6754.00AVPASS HighChannel2462MHz H2483.5060.3330.224.8523.9858.9474.00PKPASS H2485.5052.0630.224.8523.9850.6754.00AVPASS H2483.5062.1630.224.8523.9860.7774.00PKPASS H2485.5052.2630.224.8523.9850.8754.00AVPASS V2483.5060.2330.224.8523.9858.8474.00PKPASS V2485.5052.1630.224.8523.9850.7754.00AVPASS V2483.5062.2130.224.8523.9860.8274.00PKPASS V2485.5052.3330.224.8523.9850.9454.00AVPASS 802.11n20 LowChannel2412MHz H2390.0060.1230.224.8523.9858.7374.00PKPASS H2390.0052.3530.224.8523.9850.9654.00AVPASS H2400.0061.2130.224.8523.9859.8274.00PKPASS H2400.0052.1330.224.8523.9850.7454.00AVPASS V2390.0060.2430.224.8523.9858.8574.00PKPASS V2390.0052.2430.224.8523.9850.8554.00AVPASS V2400.0061.2130.224.8523.9859.8274.00PKPASS V2400.0053.2130.224.8523.9851.8254.00AVPASS HighChannel2462MHz H2483.5060.3530.224.8523.9858.9674.0060.35PASS H2485.5051.6830.224.8523.9850.2954.0051.68PASS H2483.5061.2230.224.8523.9859.8374.0061.22PASS H2485.5053.2430.224.8523.9851.8554.0053.24PASS V2483.5061.0330.224.8523.9859.6474.0061.03PASS V2485.5052.4530.224.8523.9851.0654.0052.45PASS V2483.5061.2230.224.8523.9859.8374.0061.22PASS ProjectNo.:ZKT-2107263677E Page 32 of 56 V2485.5052.3630.224.8523.9850.9754.0052.36PASS 802.11n40 LowChannel2422MHz H2390.0059.9730.224.8523.9858.5874.00PKPASS H2390.0051.8530.224.8523.9850.4654.00AVPASS H2400.0061.8730.224.8523.9860.4874.00PKPASS H2400.0051.7430.224.8523.9850.3554.00AVPASS V2390.0059.7830.224.8523.9858.3974.00PKPASS V2390.0051.8730.224.8523.9850.4854.00AVPASS V2400.0061.8730.224.8523.9860.4874.00PKPASS V2400.0051.7930.224.8523.9850.4054.00AVPASS HighChannel2452MHz H2483.5059.9530.224.8523.9858.5674.00PKPASS H2485.5051.8830.224.8523.9850.4954.00AVPASS H2483.5061.7530.224.8523.9860.3674.00PKPASS H2485.5051.7630.224.8523.9850.3754.00AVPASS V2483.5059.8830.224.8523.9858.4974.00PKPASS V2485.5051.7330.224.8523.9850.3454.00AVPASS V2483.5062.2330.224.8523.9860.8474.00PKPASS V2485.5052.3630.224.8523.9850.9752.36AVPASS Remark: 1.EmissionLevel=MeterReading+AntennaFactor+CableLoss–Pre-amplifier,Margin=EmissionLevel-Limit ProjectNo.:ZKT-2107263677E Page 33 of 56 6.POWERSPECTRALDENSITYTEST TestRequirement:FCCPart15CSection15.247(e) TestMethod:KDB558074D0115.247MeasGuidancev05r02 6.1APPLIEDPROCEDURES/LIMIT FCCPart15(15.247),SubpartC SectionTestItemLimit FrequencyRange (MHz) Result 15.247PowerSpectralDensity8dBm/3kHz2400-2483.5PASS 6.2TESTPROCEDURE 1.SetanalyzercenterfrequencytoDTSchannelcenterfrequency. 2.Setthespanto1.5timestheDTSbandwidth. 3.SettheRBWto:3kHz≤RBW≤100kHz. 4.SettheVBW≥3xRBW. 5.Detector=peak. 6.Sweeptime=autocouple. 7.Tracemode=maxhold. 8.Allowtracetofullystabilize. 9.UsethepeakmarkerfunctiontodeterminethemaximumamplitudelevelwithintheRBW. 10.Ifmeasuredvalueexceedslimit,reduceRBW(nolessthan3kHz)andrepeat. 6.3DEVIATIONFROMSTANDARD Nodeviation. 6.4TESTSETUP 6.5EUTOPERATIONCONDITIONS TheEUTtestedsystemwasconfiguredasthestatementsof2.1Unlessotherwiseaspecialoperating conditionisspecifiedinthefollowsduringthetesting. ProjectNo.:ZKT-2107263677E Page 34 of 56 6.6TESTRESULT Temperature: 26°C RelativeHumidity: 54% Pressure: 101kPa TestVoltage: 120V/60Hz TestMode : TXbMode Frequency PowerSpectral Density (dBm/3kHz) Limit (dBm/3kHz) Result 2412MHz-4.8678PASS 2437MHz-5.2868PASS 2462MHz-5.6578PASS TXCH01 ProjectNo.:ZKT-2107263677E Page 35 of 56 TXCH06 TXCH11 ProjectNo.:ZKT-2107263677E Page 36 of 56 Temperature : 26°C RelativeHumidity : 54% Pressure : 101kPa TestVoltage : 120V/60Hz TestMode: TXgMode Frequency PowerSpectral Density (dBm/3kHz) Limit (dBm/3kHz) Result 2412MHz-11.8778PASS 2437MHz-11.8668PASS 2462MHz-14.5218PASS TXCH01 ProjectNo.:ZKT-2107263677E Page 37 of 56 TXCH06 TXCH11 ProjectNo.:ZKT-2107263677E Page 38 of 56 Temperature : 26°C RelativeHumidity : 54% Pressure : 101kPa TestVoltage : 120V/60Hz TestMode: TXnMode(20M) Frequency PowerSpectral Density (dBm/3kHz) Limit (dBm/3kHz) Result 2412MHz-10.3248PASS 2437MHz-11.6408PASS 2462MHz-11.3498PASS TXCH01 ProjectNo.:ZKT-2107263677E Page 39 of 56 TXCH06 TXCH11 ProjectNo.:ZKT-2107263677E Page 40 of 56 Temperature : 26°C RelativeHumidity : 54% Pressure : 101kPa TestVoltage : 120V/60Hz TestMode: TXnMode(40M) Frequency PowerSpectral Density (dBm/3kHz) Limit (dBm/3kHz) Result 2422MHz-16.1478PASS 2437MHz-17.0218PASS 2452MHz-16.3948PASS TXCH03 ProjectNo.:ZKT-2107263677E Page 41 of 56 TXCH06 TXCH09 ProjectNo.:ZKT-2107263677E Page 42 of 56 7.CHANNELBANDWIDTH&99%OCCUPYBANDWIDTH TestRequirement:FCCPart15CSection15.247(a)(2) TestMethod:KDB558074D0115.247MeasGuidancev05r02 7.1APPLIEDPROCEDURES/LIMIT FCCPart15(15.247),SubpartC SectionTestItemLimit FrequencyRange (MHz) Result 15.247(a)(2)Bandwidth >=500KHz (6dBbandwidth) 2400-2483.5PASS 7.2…
Text truncated - open the document above for the full version.
EUTTESTPHOTO
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.41 GHz - 2.46 GHz | 17.30 mW |

LED controller
Equipment Class
DTS - Digital Transmission System