Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
ShenzhencityDoowisIndustrialCo.,Ltd 2.911(d)(5)(i)EquipmentTypeAttestationv1.2 Section2.911(d)(5)(i)Certification–EquipmentType Companyname:ShenzhencityDoowisIndustrialCo.,Ltd Address:Room202,BuildingB,YongweiIndustrialPark,No.118YongfuRoad,QiaotouCommunity, FuhaiSubdistrict,Bao’anDistrict,Shenzhen518110China ProductName:W6CTablet FCCID:2A369-W6C Model(s):W6C,W7B,F9 2.911(d)(5)(i)EquipmentType We,[ShenzhencityDoowisIndustrialCo.,Ltd](“theapplicant”)certifythattheequipmentforwhich authorizationissoughtthroughcertificationisnot:  Prohibitedfromreceivinganequipmentauthorizationpursuantto§2.903;oftheFCCrules.  Identifiedasanequipmenttypeinthe“CoveredList” NOTE1 Yourssincerely, Name:zhengchenDate:2026-4-10 TitleandCompanyname:GeneralManager/ShenzhencityDoowisIndustrialCo.,Ltd NOTE1 “CoveredList”;istheListofEquipmentandServicesCoveredBySection2ofTheSecureNetworksAct,availableat https://www.fcc.gov/supplychain/coveredlist References; 1)986446D01CoveredEquipmentv01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2)FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
ShenzhencityDoowisIndustrialCo.,Ltd 2.911(d)(5)(ii)ApplicantAttestationv1.3 Section2.911(d)(5)(ii)Certification–Applicant(CoveredList) Companyname:ShenzhencityDoowisIndustrialCo.,Ltd Address:Room202,BuildingB,YongweiIndustrialPark,No.118YongfuRoad,QiaotouCommunity, FuhaiSubdistrict,Bao’anDistrict,Shenzhen518110China ProductName:W6CTablet FCCID:2A369-W6C Model(s):W6C,W7B,F9 2.911(d)(5)(ii)Applicantfiling We,[ShenzhencityDoowisIndustrialCo.,Ltd](“theapplicant”)certifythat,asofthedateofthefiling oftheapplication,theapplicantisnotidentified NOTE1 onthe“CoveredList” NOTE2 ,established pursuantto§1.50002ofthischapter,asanentityproducingcoveredcommunicationsequipment. Yourssincerely, Name:zhengchenDate:2026-4-10 TitleandCompanyname:GeneralManager/ShenzhencityDoowisIndustrialCo.,Ltd NOTE1 Deleteoptionnotapplicabletothisapplication. NOTE2 “CoveredList”;istheListofEquipmentandServicesCoveredBySection2ofTheSecureNetworksAct,availableat https://www.fcc.gov/supplychain/coveredlist References; 1)986446D01CoveredEquipmentv01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2)FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
ShenzhencityDoowisIndustrialCo.,Ltd LetterofAuthorization Company:ShenzhencityDoowisIndustrialCo.,Ltd Address:Room202,BuildingB,YongweiIndustrialPark,No.118YongfuRoad, QiaotouCommunity,FuhaiSubdistrict,Bao’anDistrict,Shenzhen518110China ProductName:W6CTablet ModelNumber(s):W6C,W7B,F9 ProductDescription:W6CTablet FCCID:2A369-W6C WeauthorizeMiCOMLabsInc.,575BoulderCourt,Pleasanton,California94566,USA, toactonourbehalfonallmattersconcerningthecertificationofabovenamed equipment. WedeclarethatMiCOMLabsInc.isallowedtoforwardallinformationrelatedtothe approvalandcertificationofequipmenttotheregulatoryagenciesasrequiredandto discussanyissuesconcerningtheapprovalapplication.Anyandallactscarriedoutby MiCOMLabsonourbehalfshallhavethesameeffectasactsofourown. Signature:Date: 2026-4-10 Name:zhengchen Title:GeneralManager Company:ShenzhencityDoowisIndustrialCo.,Ltd
ShenzhencityDoowisIndustrialCo.,Ltd OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:2026-4-10 Subject;RequestforConfidentiality FCCID:2A369-W6C ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthesedocuments mightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:zhengchen Title:GeneralManager
Page 1 of 1 FCC ID: 2A369-W6C Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No 44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, P.R.C. Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com LABEL AND LOCATION (Size: L4.0cm x 2.0cm) Label Location W6C Tablet Model: W6C FCC ID: 2A369-W6C
Any reproduction of this document must be done in full. No single part of this document may be reproduced without permission from STS, All Test Data Presented in this report is only applicable to presented Test sample. ShenZhen STS Test Services Co.,Ltd. A 1/F, Building B, Zhuoke Science Park, No.190 Chongqing Road, HepingShequ, Fuyong Sub-District, Bao’an District, Shenzhen, Guang Dong, China TEL: +86-755 3688 6288 FAX: +86-755 3688 6277 E-mail:[email protected] S T L A B S SAR Dipole Performance Measurement Report EUT Type: SAR Validation Dipole and Waveguide Model Name: DIP2G450, WGA32 Brand Name: SATIMO Test Conclusion: Pass Test Date: 01 Jul . 2024&03 Jul. 2025 Date of Issue: 03 Jul. 2025 Testing Engineer : (Xin.Liu) Technical Manager : (Shifan. Long) Authorized Signatory : (Bovey Yang) ISSUED BY Shenzhen STS Test Services Co., Ltd. Kind of Equipment Manufacturer Type No. Serial No. Last Calibration Calibrated Until PC Acer N/A N/A N/A N/A E-Field Probe MVG SSE2 SN 08/21 EPGO352 2024.09.18 2025.09.17 Dielectric Probe Kit MVG SCLMP SN 32/14 OCPG67 2024.09.18 2025.09.17 Phantom1 MVG SAM SN 32/14 SAM115 N/A N/A Phantom2 MVG SAM SN 32/14 SAM116 N/A N/A Attenuator Agilent 99899 DC-18GHz N/A N/A Directional coupler Narda 4226-20 3305 N/A N/A Network Analyzer Agilent E5071C MY46520378 2024-09-25 2025-09-26 Multi Meter Keithley Multi Meter 2000 4050073 2024-09-25 2025-09-26 Signal Generator Agilent N5182A MY50140530 2024-09-25 2025-09-26 Power Amplifier DESAY ZHL-42W 9638 2024-09-25 2025-09-26 Power Meter R&S NRP 100510 2024-09-25 2025-09-26 Power Sensor R&S NRP-Z11 101919 2024-09-25 2025-09-26 Power Sensor Keysight U2021XA MY56280002 2024-09-25 2025-09-26 Temperature hygrometer SuWei SW-108 N/A 2024.10.15 2025.10.14 Thermograph Elitech RC-4 S/N EF7176501537 2024.10.15 2025.10.14 ISSUED BY Shenzhen STS Test Services Co., Ltd. 2. <Justification of the extended calibration> Referring to KDB 865664 D01, if dipoles are verified in return loss<-20dB, (within 20% of prior calibration), and in impedance (within 5 ohm of prior calibration), the annual calibration is not necessary and the calibration interval can be extended. Head 2450 MHz Date of Measurement Return Loss (dB) Delta (%) Impedance Delta(ohm) 2023.07.04 -26.03 - 46.3 - 2024.07.01 -26.42 1.50 47.25 0.95 2025.07.03 -25.75 3.38 49.40 3.10 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. <Dipole Verification Data> Head 2450 MHz ISSUED BY Shenzhen STS Test Services Co., Ltd. Head 5000 MHz Date of Measurement Return Loss (dB) Delta (%) Impedance Delta(ohm) 2023.07.04 < -8.23 - - - 2024.07.01 -9.10 10.57 - - 2025.07.01 -8.59 17.86- - - The return loss is <-8dB, within 20% of prior calibration; Therefore the verification result should support extended calibration. <Dipole Verification Data> Head 5000MHz
The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Shenzhen STS Test Services Co., Ltd. SAR Test Report Report No.: STS2603088H01 Issued for Shenzhen city Doowis Industrial Co., Ltd Room 202, Building B, Yongwei Industrial Park, No. 118 Yongfu Road, Qiaotou Community, Fuhai Subdistrict, Bao’ an District, Shenzhen Product Name: W6C Tablet Brand Name: Headwolf Model Name: W6C Series Model(s): W7B, F9 FCC ID: 2A369-W6C Test Standard: ANSI/IEEE Std. C95.1 FCC 47 CFR Part 2 (2.1093) IEEE Std. 1528-2013 Max. Report SAR (10&1g) Body: 1.128 W/kg(1g) Page 2 of 59 Report No.: STS2603088H01 TEST REPORT CERTIFICATION Applicant’s name ................. : Shenzhen city Doowis Industrial Co., Ltd Address ................................. : Room 202, Building B, Yongwei Industrial Park, No. 118 Yongfu Road, Qiaotou Community, Fuhai Subdistrict, Bao’an District, Shenzhen Manufacturer's Name .......... : Shenzhen city Doowis Industrial Co., Ltd Address ................................. : Room 202, Building B, Yongwei Industrial Park, No. 118 Yongfu Road, Qiaotou Community, Fuhai Subdistrict, Bao’an District, Shenzhen Product description Product name ........................ : W6C Tablet Brand name ......................... : Headwolf Model name ......................... : W6C Series Model(s) : ..................... W7B, F9 Standards ............................. : ANSI/IEEE Std. C95.1 FCC 47 CFR Part 2 (2.1093) IEEE Std. 1528-2013 The device was tested by Shenzhen STS Test Services Co., Ltd. in accordance with the measurement methods and procedures specified in KDB 865664 The test results in this report apply only to the tested sample of the stated device/equipment. Other similar device/equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties. Date of Test ............................................ : Date (s) of performance of tests ............. : 17 Mar. 2026 Date of Issue ........................................... : 25 Mar. 2026 Test Result ............................................... : Pass Testing Engineer : (Xin.Liu) Technical Manager : (Shifan. Long) Authorized Signatory : (Bovey Yang) Page 3 of 59 Report No.: STS2603088H01 Table of Contents 1. General Information ................................................................................................................... 5 1.1 EUT Description .................................................................................................................... 5 1.2 Test Environment .................................................................................................................. 7 1.3 Test Factory .......................................................................................................................... 7 2. Test Standards and Limits ........................................................................................................ 8 3. SAR Measurement System........................................................................................................ 9 3.1 Definition of Specific Absorption Rate (SAR) ........................................................................ 9 3.2 SAR System ......................................................................................................................... 9 4. Tissue Simulating Liquids ...................................................................................................... 12 4.1 Simulating Liquids Parameter Check.................................................................................. 12 5. SAR System Validation ............................................................................................................ 16 5.1 Validation System ............................................................................................................... 16 5.2 Validation Result ................................................................................................................. 17 6. SAR Evaluation Procedures.................................................................................................... 18 7. EUT Antenna Location Sketch ................................................................................................ 19 7.1 SAR test exclusion consider table ...................................................................................... 20 8. EUT Test Position ..................................................................................................................... 23 8.1 Body-worn Position Conditions ........................................................................................... 23 9. Uncertainty ............................................................................................................................... 24 9.1 Measurement Uncertainty................................................................................................... 24 10. Conducted Power Measurement .......................................................................................... 27 10.1 Test Result ........................................................................................................................ 27 2.4G WLAN .............................................................................................................................. 27 11. EUT and Test Setup Photo .................................................................................................... 30 11.1 EUT Photo ........................................................................................................................ 30 11.2 Setup Photo ...................................................................................................................... 33 12 . SAR Result Summary ............................................................................................................ 35…
Text truncated - open the document above for the full version.
Page: 1/11 SHENZHEN STS TEST SERVICES CO., LTD. 1/F, BUILDING 2, ZHUOKE SCIENCE PARK, 190 CHONGQING ROAD FUYONG, BAO’ AN DISTRICT, SHENZHEN,CHINA MVG COMOSAR DOSIMETRIC E-FIELD PROBE SERIAL NO.: SN 08/21 EPGO352 Calibrated at MVG Z.I. de la pointe du diable Technopôle Brest Iroise – 295 avenue Alexis de Rochon 29280 PLOUZANE - FRANCE Calibration date: 09/15/2025 Accreditations #2-6789 Scope available on www.cofrac.fr The use of the Cofrac brand and the accreditation references is prohibited from any reproduction. Summary: This document presents the method and results from an accredited COMOSAR Dosimetric E-Field Probe calibration performed at MVG, using the CALIPROBE test bench, for use with a MVG COMO SAR system only. The test results covered by accreditation are traceable to the International System of Units (SI). COMOSAR E-Field Probe Calibration Report Ref : ACR.95.19.25.BES.A Docusign Envelope ID: 711C3E09-7054-43A0-BF16-C536091746C4 COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.95.19.25.BES.A Page: 2/11 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Probe vM This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. Name Function Date Signature Prepared by : Pedro Ruiz Measurement Responsible 9/16/2025 Checked & approved by: Jérôme L uc Technical Manager 9/16/2025 Authorized by: Laboratory Director Customer Name Distribution : Shenzhen STS Test Services Co., Ltd. Issue Name Date Modifications A Pedro Ruiz 9/16/2025 Initial release Docusign Envelope ID: 711C3E09-7054-43A0-BF16-C536091746C4 Geraldine Toutain 9/16/2025 COMOSAR E-FIELD PROBE CALIBRATION REPORT Page: 3/11 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Probe vM This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. TABLE OF CONTENTS 1 Device Under Test ..................................................................................................... 4 2 Product Description ................................................................................................... 4 2.1 General Information _______________________________________________________ 4 3 Measurement Method ................................................................................................ 4 3.1 Sensitivity _______________________________________________________________ 4 3.2 Linearity ________________________________________________________________ 5 3.3 Isotropy _________________________________________________________________ 5 3.4 Boundary Effect __________________________________________________________ 5 3.5 Probe Modulation Response _________________________________________________ 6 4 Measurement Uncertainty .......................................................................................... 6 5 Calibration Results ..................................................................................................... 6 5.1 Calibration in air __________________________________________________________ 6 5.2 Calibration in liquid _______________________________________________________ 7 6 Verification Results ................................................................................................... 8 7 List of Equipment ...................................................................................................... 9 Docusign Envelope ID: 711C3E09-7054-43A0-BF16-C536091746C4 Ref: ACR.95.19.25.BES.A COMOSAR E-FIELD PROBE CALIBRATION REPORT Page: 4/11 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Probe vM This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. 1 DEVICE UNDER TEST Device Under Test Device Type COMOSAR DOSIMETRIC E FIELD PROBE Manufacturer MVG Model SSE2 Serial Number SN 08/21 EPGO352 Product Condition (new / used) Used Frequency Range of Probe 0.15 GHz-7.5GHz Resistance of Three Dipoles at Connector Dipole 1: R1=0.222 M: Dipole 2: R2=0.198 M: Dipole 3: R3=0.191 M: 2 PRODUCT DESCRIPTION 2.1 GENERAL INFORMATION MVG’s COMOSAR E field Probes are built in accordance to the IEC/IEEE 62209-1528 and FCC KDB865664 D01 standards. Figure 1 – MVG COMOSAR Dosimetric E field Probe Probe Length 330 mm Length of Individual Dipoles 2 mm Maximum external diameter 8 mm Probe Tip External Diameter 2.5 mm Distance between dipoles / probe extremity 1 mm 3 MEASUREMENT METHOD The IEC/IEEE 62209-1528 and FCC KDB865664 D01 standards provide recommended practices for the probe calibrations, including the performance characteristics of interest and methods by which to assess their effect. All calibrations / measurements performed meet the fore-mentioned standards. 3.1 SENSITIVITY The sensitivity factors of the three dipoles were determined using a two step calibration method (air and tissue simulating liquid) using waveguides as outlined in the standards for frequency range 600- 7500MHz and using the calorimeter cell method (transfer method) as outlined in the standards for frequency 150-450 MHz. Docusign Envelope ID: 711C3E09-7054-43A0-BF16-C536091746C4 Ref: ACR.95.19.25.BES.A COMOSAR E-FIELD PROBE CALIBRATION REPORT Page: 5/11 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Probe vM This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. 3.2 LINEARITY The evaluation of the linearity was done in fr…
Text truncated - open the document above for the full version.
Page1of35FCCID:2A369-W6CReportNo.:LCSC01236006EB GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com AppendixB RFTestDataforBTLE(ConductedMeasurement) ProductName:W6CTablet TestModel:W6C EnvironmentalConditions Temperature: 24.1  C RelativeHumidity:53.2% ATMPressure:100.0kPa TestEngineer:Zhanghai Supervisedby:FengliuTang Page2of35FCCID:2A369-W6CReportNo.:LCSC01236006EB GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com B.1DTSBandwidth TestResult TestModeAntennaFreq(MHz) DTSBW [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict BLE_1MAnt1 24020.6562401.6722402.3280.5PASS 24400.6602439.6682440.3280.5PASS 24800.6602479.6682480.3280.5PASS BLE_2MAnt1 24021.1282401.4202402.5480.5PASS 24401.1242439.4202440.5440.5PASS 24801.1242479.4202480.5440.5PASS Note:offset=Systemattenuation+caballoss Page3of35FCCID:2A369-W6CReportNo.:LCSC01236006EB GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Page4of35FCCID:2A369-W6CReportNo.:LCSC01236006EB GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com BLE_2M_Ant1_2402 BLE_2M_Ant1_2440 Page5of35FCCID:2A369-W6CReportNo.:LCSC01236006EB GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com BLE_2M_Ant1_2480 Page6of35FCCID:2A369-W6CReportNo.:LCSC01236006EB GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com B.2MaximumPeakConductedOutputPower TestResultPeak TestModeAntennaFreq(MHz) ConductedPeak Powert[dBm] Conducted Limit[dBm] Verdict BLE_1MAnt1 24020.83≤30PASS 24402.36≤30PASS 24802.24≤30PASS BLE_2MAnt1 24020.60≤30PASS 24402.25≤30PASS 24802.02≤30PASS Note:offset=Systemattenuation+caballoss Page7of35FCCID:2A369-W6CReportNo.:LCSC01236006EB GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com TestGraphsPeak BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Page8of35FCCID:2A369-W6CReportNo.:LCSC01236006EB GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com BLE_2M_Ant1_2402 BLE_2M_Ant1_2440 Page9of35FCCID:2A369-W6CReportNo.:LCSC01236006EB GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com BLE_2M_Ant1_2480 Page10of35FCCID:2A369-W6CReportNo.:LCSC01236006E B GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com B.3Maximumpowerspectraldensity TestResult TestModeAntennaFreq(MHz)Result[dBm/3kHz]Limit[dBm/3kHz]Verdict BLE_1MAnt1 2402-14.93≤8.00PASS 2440-13.16≤8.00PASS 2480-13.43≤8.00PASS BLE_2MAnt1 2402-17.54≤8.00PASS 2440-15.56≤8.00PASS 2480-15.84≤8.00PASS Note:offset=Systemattenuation+caballoss Page11of35FCCID:2A369-W6CReportNo.:LCSC01236006E B GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Page12of35FCCID:2A369-W6CReportNo.:LCSC01236006E B GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com BLE_2M_Ant1_2402 BLE_2M_Ant1_2440 Page13of35FCCID:2A369-W6CReportNo.:LCSC01236006E B GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com BLE_2M_Ant1_2480 Page14of35FCCID:2A369-W6CReportNo.:LCSC01236006E B GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com B.4Bandedgemeasurements TestResult TestModeAntennaChNameFreq(MHz)RefLevel[dBm]Result[dBm]Limit[dBm]Verdict BLE_1MAnt1 Low2402-0.26-45.38≤-20.26PASS High24801.29-45.34≤-18.71PASS BLE_2MAnt1 Low2402-0.58-44.58≤-20.58PASS High24801.00-44.36≤-19PASS Note:offset=Systemattenuation+caballoss Page15of35FCCID:2A369-W6CReportNo.:LCSC01236006E B GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com TestGraphs BLE_1M_Ant1_Low_2402 BLE_1M_Ant1_High_2480 BLE_2M_Ant1_Low_2402 Page16of35FCCID:2A369-W6CReportNo.:LCSC01236006E B GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com BLE_2M_Ant1_High_2480 Page17of35FCCID:2A369-W6CReportNo.:LCSC01236006E B GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs…
Text truncated - open the document above for the full version.
Page1of47FCCID:2A369-W6CReportNo.:LCSC01236006EC GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com AppendixC RFTestDatafor2.4GWIFI(ConductedMeasurement) ProductName:W6CTablet TestModel:W6C EnvironmentalConditions Temperature: 24.1  C RelativeHumidity:53.2% ATMPressure:100.0kPa TestEngineer:Zhanghai Supervisedby:FengliuTang Page2of47FCCID:2A369-W6CReportNo.:LCSC01236006EC GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com C.1DTSBandwidth TestResult TestModeAntennaFrequency[MHz] DTSBW [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict 11BAnt1 24129.6402407.4402417.0800.5PASS 24379.6402431.9602441.6000.5PASS 24629.6402457.4002467.0400.5PASS 11GAnt1 241216.1202404.0802420.2000.5PASS 243716.2802428.8002445.0800.5PASS 246216.3602453.8402470.2000.5PASS 11N20SISOAnt1 241216.9602403.7202420.6800.5PASS 243717.3202428.2002445.5200.5PASS 246217.3202453.4002470.7200.5PASS Note:offset=Systemattenuation+caballoss Page3of47FCCID:2A369-W6CReportNo.:LCSC01236006EC GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com TestGraphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 Page4of47FCCID:2A369-W6CReportNo.:LCSC01236006EC GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com 11G_Ant1_2412 11G_Ant1_2437 Page5of47FCCID:2A369-W6CReportNo.:LCSC01236006EC GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com 11G_Ant1_2462 11N20SISO_Ant1_2412 Page6of47FCCID:2A369-W6CReportNo.:LCSC01236006EC GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com 11N20SISO_Ant1_2437 11N20SISO_Ant1_2462 Page7of47FCCID:2A369-W6CReportNo.:LCSC01236006EC GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com Page8of47FCCID:2A369-W6CReportNo.:LCSC01236006EC GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com C.2MaximumAverageConductedOutputPower TestResultAverage TestModeAntenna Frequency [MHz] Conducted Power (dBm) DC Factor [dB] TotalMaximum Average LimitConducted(dBm)Verdict 11BAnt1 241217.730.1017.8330Pass 243718.560.0918.6530Pass 246217.860.1217.9830Pass 11GAnt1 241216.870.6917.5630Pass 243718.170.5318.7030Pass 246217.960.5318.4930Pass 11N20SISOAnt1 241217.380.5017.8830Pass 243717.910.7418.6530Pass 246219.130.5319.6630Pass Note:offset=Systemattenuation+caballoss Page9of47FCCID:2A369-W6CReportNo.:LCSC01236006EC GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com C.3Maximumpowerspectraldensity TestResult TestModeAntennaFrequency[MHz] MeasuredPSD [dBm/30kHz] DC Factor [dB] Result[dBm/30kHz]Limit[dBm/3kHz]Verdict 11BAnt1 2412-4.390.10-4.29≤8.00PASS 2437-3.20.09-3.11≤8.00PASS 2462-2.840.12-2.72≤8.00PASS 11GAnt1 2412-6.870.69-6.18≤8.00…
Text truncated - open the document above for the full version.
1408 Pinon Place Fullerton, CA 92835 United States · AUSTIN, California, 92835 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.72 mW |
| 2 | 15C | 2.41 GHz - 2.46 GHz | 92.47 mW |

AI Voice Recorder
Equipment Class
DTS - Digital Transmission System