FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Hongheng Technology Co., Ltd./
  3. 2A36C-HH02

2A36C-HH02Wireless Charging RGB Gaming Mouse Pad

Shenzhen Hongheng Technology Co., Ltd.
Wireless Charging RGB Gaming Mouse Pad - FCC ID 2A36C-HH02 - Shenzhen Hongheng Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Jan 17, 2022
Application Purpose
Original Equipment
Date of Application
Jan 16, 2022
Equipment Note
Wireless Charging RGB Gaming Mouse Pad
Frequency Range
0.11150000 - 0.20500000
Company
Shenzhen Hongheng Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 2 3 4 1. Power Interface: Plug the detachable Type-C USB c able to mouse pad to power it u p 2. Fingerprint switch: Touch the switch to change the light mode or change the light c olor 3. Wireless charging transmitter location Put the mobile phone in this pos ition. If the indicator light o f the fingerprint swi tch turns red, it indicates that the mobile phone is charging. If the indicator light turns green , it indicates that the mobil e phone is fully charged. 4. Mouse Pad The computer mouse can work smoothly on the surface This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that m ay cause undesired operation. FCC Warning Statement Changes or modifications not exp ressly approved by the party re sponsible for compliance coul d void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the lim its for a Class B digital devic e, pursuant to Part 15 of the FC C Rules. These limits are designed to provide reasona ble protection against harmful i nterference in a residential i nstallation. This equipment gener ates uses and can radiate radio frequency energy and, if not installed and used i n accordance with the instructi ons, may cause harmful interfere nce to radio communications. However, there is no guarantee that interferenc e will not occur in a particula r installation. If this equipmen t does cause harmful interference to radio or televi sion reception, which can be det ermined by turning the equipm ent off and on, the user is encour aged to try to correct the interference by one or mor e of the following measures: --Reorient or relocate the receiving antenna. --Increase the separation betwe en the equipment and receiver. --Connect the equipment into an outle t on a circuit different f rom that t o which the receiver is connected. --Consult the dealer or an experi enced radio/TV technician for help. The distance between user and products should be no less than 2 0cm

Cover Letter(s)

January 13, 2022 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act as Agent On our behalf, I appoint Shenzhen Timeway Testing Laboratories/ Zone C, 1st Floor, Zone C, 1st Floor, Block B, Jun Xiang Da Building, Zhongshan Park Road West, Tong Le Village, Nanshan District, Shenzhen, China (Name of Agent company name and address) to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, still resides with Shenzhen Hongheng Technology Co., Ltd. / Room 501, Block B, Hongde Industrial Park, Dalang street, Longhua District, Shenzhen, China <Signature>: Name:Zheng Zhao Title:Manager Applicant Company:Shenzhen Hongheng Technology Co., Ltd.

Cover Letter(s)

January 13, 2022 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2A36C-HH02 Product Name: Wireless Charging RGB Gaming Mouse Pad Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: • Schematics • Block diagram • Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. <Signature>: Name:Zheng Zhao Title:Manager Applicant Company:Shenzhen Hongheng Technology Co., Ltd.

ID Label/Location Info

Model NO:HH-02 Output: 5W/7.5W/10W/15W RoHS Shenzhen HongHeng technogy Co,LTD This device complies with part 15 of the FCC rules Operation is subject to the following two conditions (1) this device may not cause harmful interference and(2) this device must accept any interfence received including interference that may cause undesired operation FCC ID: 2A36C-HH02

ID Label/Location Info

Label Location

RF Exposure Info

FCC ID: 2A36C-HH02 RF Exposure Evaluation 1 Measuring Standard KDB 680106 D01 RF Ex posure Wireless Charging App v03r01 And TCB Workshop, October 2018, 5.2 RF Exposure Procedures 2 Requirements According to the item 5 of KDB 680106 D01 RF Exposure Wireless Charging App v03r01: (1) Power transfer frequency is less than 1 MHz. Yes (2) Output power from each primary coil is less than or equal to 15 watts. Yes (3) The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils. Yes (3) Client device is placed directly in contact with the transmitter. Yes (5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion). No (6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. Yes Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) Report No.: TW2112343-H Page 2 of 5 Date: 2022-01-18 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES.It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES.reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. 3 Test Setup A: B: Report No.: TW2112343-H Page 3 of 5 Date: 2022-01-18 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES.It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES.reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. 4 Test Procedure 1) The RF exposure test was performed in an echoic chamber; 2) The measurement probe was placed at test distance(15 cm from edges, 20 cm from top) Which is between the edge of the charger and the geometric center of probe, for test setup A; 3) In addition to what is described in KDB 680106 D01, please measure and provide magnetic and electrical field strength at a distance 10cm to 1cm at 1cm iteration, i.e. at a distance of 10cm, 9cm, 8cm, ....... 1cm. Which is between the edge of the charger and the edge of probe, for test setup B; 4)The highest emission level wa s recorded and compared with limit as soon as measurement of each points (A,B, C,D, E)were completed; 5)The EUT was measured according to the dictates of KDB680106D01v03r01; And TCB Workshop, October 2018, 5.2 RF Exposure Procedures Remark:The EUT’ s test position A, B,C, D and E is valid for the E and H field measurements. 5 Test Instruments list Test Equipment Manufacturer Model No. SN. Cal.Date (mm-dd-yy) Cal.Due date (mm-dd-yy) EMF Meter NARDA ELT-400 N-0356 Oct 09 2021 Oct 08 2022 EMF probe NARDA B-Field ProbeM-0812 Oct 09 2021 Oct 08 2022 6 Test Result Remark: Wireless Output: 5W/7.5W/10W/15W modes all have been tested, only worse case mode Wireless Output 15W is reported. Test Result for Test setup A: Note: 1. Frequency Range 0.1115-0.205 (MHz); <5%, 50 %,> 90% load all have been tested, Only worse case Max load (>90%) is reported. E-Filed Strength at (15 cm from edges A, B, C, D, 20 cm from top E) surrounding the EUT (V/m) Charging Load Worse case Test Position A(V/m) Test Position B(V/m) Test Position C(V/m) Test Position D(V/m) Test Position E(V/m) Limits (V/m) Max load 1.62 1.52 1.39 1.29 1.43 614 H-Filed Strength at (15 cm from edges A, B, C, D, 20 cm from top E) surrounding the EUT (A/m) Charging Load Worse case Test Position A(A/m) Test Position B(A/m) Test Position C(A/m) Test Position D(A/m) Test Position E(A/m) Limits (A/m) Max load 0.65 0.56 0.42 0.43 0.35 1.63 Report No.: TW2112343-H Page 4 of 5 Date: 2022-01-18 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES.It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY…

Text truncated - open the document above for the full version.

Test Report

Report No.: TW2112343E File Reference No.: 2021-12-29 Applicant: Shenzhen Hongheng Technology Co., Ltd. Product: Wireless Charging RGB Gaming Mouse Pad Model No.: HH-02 Trademark: N/A Test Standards: FCC Part 15 Subpart C Test Result: It is herewith confirmed and found to comply with the requirements set up by ANSI C63.4&FCC Part 15 Subpart C, for the evaluation of electromagnetic compatibility Approved By Jack Chung Manager Dated: December 29, 2021 Results appearing herein relate only to the sample tested The technical reports is issued errors and omissions exempt and is subject to withdrawal at SHENZHEN TIMEWAY TESTING LABORATORIES Zone C, 1st Floor, Block B, Jun Xiang Da Building, Zhongshan Park Road West, Tong Le Village, Nanshan District, Shenzhen, China Tel (755) 83448688, Fax (755) 83442996, E-Mail:[email protected] Report No: TW2112343E Page 2 of 29 Date: 2021-12-29 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Special Statement: The testing quality ability of our laboratory meet with "Quality Law of People's Republic of China" Clause 19. The testing quality system of our laboratory meets with ISO/IEC-17025 requirements, which is approved by CNAS. This approval result is accepted by MRA of APLAC. Our test facility is recognized, certified, or accredited by the following organizations: CNAS-LAB Code: L2292 The EMC Laboratory has been assessed and in compliance with CNAS-CL01 accreditation criteria for testing Laboratories (identical to ISO/IEC 17025:2005 General Requirements) for the Competence of testing Laboratories. FCC-Registration No.: 744189 The EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications commission. The acceptance letter from the FCC is maintained in our files. Registration No.: 744189. Industry Canada (IC) —Registration No.:5205A The EMC Laboratory has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 5205A. A2LA (Certification Number:5013.01) The EMC Laboratory has been accredited by the American Association for Laboratory Accreditation (A2LA). Certification Number:5013.01 Report No: TW2112343E Page 3 of 29 Date: 2021-12-29 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Test Report Conclusion Content 1.0 General Details ................................................................................................ 4 1.1 Test Lab Details................................................................................................ 4 1.2 Applicant Details.............................................................................................. 4 1.3 Description of EUT .......................................................................................... 4 1.4 Submitted Sample............................................................................................. 5 1.5 Test Duration.................................................................................................... 5 1.6 Test Uncertainty................................................................................................. 5 1.7 Test By.......................................................................................................... 5 2.0 List of Measurement Equipment......................................................................... 6 3.0 Technical Details............................................................................................. 7 3.1 Summary of Test Results..................................................................................... 7 3.2 Test Standards.................................................................................................. 7 4.0 EUT Modification............................................................................................. 7 5.0 Power Line Conducted Emission Test...................................................................... 8 5.1 Schematics of the Test........................................................................................ 8 5.2 Test Method and Test Procedure............................................................................ 8 5.3 Configuration of the EUT.................................................................................... 8 5.4 EUT Opera…

Text truncated - open the document above for the full version.

Test Setup Photos

Conducted Emission Test Setup: Radiated Emission Test Setup:

Contact Information

Applicant

Zheng Zhao
[email protected]13928454804Fax: 0755-27042038

Test Firm

Shenzhen Timeway Testing LaboratoriesTerry Tang
[email protected]+86-755-83448688

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.1115 MHz - 0.205 MHz-
Confidentiality
Long Term