Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Equestrian Heart Rate and Motion Monitor Important Safety and Product Information 2022-08-24 Ruxbury - Important Safety and Product Information copy.indd 12022-08-24 Ruxbury - Important Safety and Product Information copy.indd 130-08-2022 20:46:2730-08-2022 20:46:27 2022-08-24 Ruxbury - Important Safety and Product Information copy.indd 22022-08-24 Ruxbury - Important Safety and Product Information copy.indd 230-08-2022 20:46:2730-08-2022 20:46:27 3 Table of contents 4 Ruxbury EM1 Sensor Device Technical Specifications 5 Disclaimer 6 Battery Warning 7 Sensor Device Warning 8 Product Disposal 9 Software License Agreement 10 Compliance Statements 2022-08-24 Ruxbury - Important Safety and Product Information copy.indd 32022-08-24 Ruxbury - Important Safety and Product Information copy.indd 330-08-2022 20:46:2730-08-2022 20:46:27 4 Ruxbury EM1 Sensor Device Technical Specifications • Battery type: 300mAh Li-pol rechargeable battery • Operating time: up to 5 days (24 hours) when used for training, up to 15 days when used for monitoring. Actual performance may vary from the laboratory tested performance. • Operating temperature: -10C to +40C, -4F to +104F • Charging temperature: +10C to +40C, +50F to +104F • Dust and water resistance equivalent to IP 67 (dust and waterproof) to ensure correct function in typical operating conditions • Operating range, EM1 sensor to a mobile phone: up to 30m indoors, up to 150m outdoor. Actual 2022-08-24 Ruxbury - Important Safety and Product Information copy.indd 42022-08-24 Ruxbury - Important Safety and Product Information copy.indd 430-08-2022 20:46:2730-08-2022 20:46:27 5 performance may vary depending on the mobile phone type, and physical conditions. • Communication protocol: Bluetooth Smart (Bluetooth Low Energy), 2.402GHz to 2.480GHz band • Charging port: micro-USB B • The Ruxbury EM1 sensor is designed to be used with the Ruxbury app Disclaimer • The provided Ruxbury sensor EM1 is not a medical device. The Ruxbury sensor is intended to be used for recreational purposes and not for medical purposes. • The heart rate readings are for reference only, and 2022-08-24 Ruxbury - Important Safety and Product Information copy.indd 52022-08-24 Ruxbury - Important Safety and Product Information copy.indd 530-08-2022 20:46:2730-08-2022 20:46:27 6 no responsibility is accepted for consequences for any erroneous readings. • Every consideration has been made to make the heart rate readings as accurate as possible but there are inherent limitations of the technology that may cause some of the heart rate readings to be inaccurate under certain circumstances, including the fit of the device to horse skin and the intensity of motion. Battery Warning A lithium-polymer battery is used in this device. If the guidelines below are not followed the batteries may experience a shortened life span or may present a risk of damage to the device: 2022-08-24 Ruxbury - Important Safety and Product Information copy.indd 62022-08-24 Ruxbury - Important Safety and Product Information copy.indd 630-08-2022 20:46:2730-08-2022 20:46:27 7 • Do not disassemble, modify, puncture, or damage the device or battery • Do not remove or attempt to remove the battery – the battery is non-user replaceable • Do not charge the device while the Ruxbury sensor is mounted on a horse • Ensure that the temperature in the location where you charge is above 10 degrees Celsius / 50 degrees Fahrenheit and below 40 degrees Celsius / 104 degrees Fahrenheit Sensor Device Warning • Do not use the device outside the operating temperature ranges 2022-08-24 Ruxbury - Important Safety and Product Information copy.indd 72022-08-24 Ruxbury - Important Safety and Product Information copy.indd 730-08-2022 20:46:2730-08-2022 20:46:27 8 • Use the provided power cable or equivalent USB-A to micro–USB B cable • The device does not contain any user serviceable parts. The only user-replaceable part is the protective outer silicone rubber sleeve • Unauthorized repairs or modifications could result in a permanent damage to the device and void your warranty and authority to operate the device Product Disposal The crossed-out bin symbol on this product means, that Ruxbury EM1 sensor device must be disposed of separately from household waste, e.g., when it reaches its end of life. 2022-08-24 Ruxbury - Important Safety and Product Information copy.indd 82022-08-24 Ruxbury - Important Safety and Product Information copy.indd 830-08-2022 20:46:2730-08-2022 20:46:27 9 Take it to the collection point designated for electronic waste for recycling and protection of the environment. Software License Agreement BY USING THE DEVICE, YOU AGREE TO BE BOUND BY THE TERMS AND CONDITIONS OF THE FOLLOWING SOFTWARE LICENSE AGREEMENT. PLEASE READ THIS AGREEMENT CAREFULLY. Ruxbury grants you a limited license to use the software embedded in this device (the “Software”) in binary executable form in the normal operation of the product. Title, ownership rights, and intellectual property rights in and to the Software remain with Ruxbury and/or its third-party providers. You acknowledge that the Software is the property of Ruxbury and/or its third-party providers and is 2022-08-24 Ruxbury - Important Safety and Product Information copy.indd 92022-08-24 Ruxbury - Important Safety and Product Information copy.indd 930-08-2022 20:46:2730-08-2022 20:46:27 10 protected under international copyright treaties. You further acknowledge that the structure, organization, and code of the Software, for which source code is not provided, are valuable trade secrets of Ruxbury. You agree not to decompile, disassemble, modify, reverse assemble, reverse engineer, or reduce to human readable form the Software or any part thereof or create any derivative works based on the Software. You agree not to export or re-export the Software to any country in violation of the export control laws of the United States of America and EU or the export control laws of any other applicable count…
Text truncated - open the document above for the full version.
Equestrian Heart Rate and Motion Monitor Quick User Guide 2022-09-02 Ruxbury - Quick User Guide.indd 12022-09-02 Ruxbury - Quick User Guide.indd 102-09-2022 15:52:0202-09-2022 15:52:02 2022-09-02 Ruxbury - Quick User Guide.indd 22022-09-02 Ruxbury - Quick User Guide.indd 202-09-2022 15:52:0202-09-2022 15:52:02 Pulse sensor Sleeve Push button with LED light Access to USB port Elastic strap for attaching the sensor device ‘Hooks’ for fastening the elastic strap 2022-09-02 Ruxbury - Quick User Guide.indd 32022-09-02 Ruxbury - Quick User Guide.indd 302-09-2022 15:52:0302-09-2022 15:52:03 2022-09-02 Ruxbury - Quick User Guide.indd 42022-09-02 Ruxbury - Quick User Guide.indd 402-09-2022 15:52:0302-09-2022 15:52:03 English Ruxbury Equestrian Heart Rate and Motion Monitor EM1 Quick User Guide 2022-09-02 Ruxbury - Quick User Guide.indd 52022-09-02 Ruxbury - Quick User Guide.indd 502-09-2022 15:52:0302-09-2022 15:52:03 Table of contents 10 Features 11 You shall provide the following items 12 Operating the Ruxbury EM1 sensor 16 Mounting the Ruxbury sensor device on a horse 18 Session Types 22 Getting Started 25 Using the Ruxbury Monitor for well-being monitoring 28 Ruxbury sensor maintenance 2022-09-02 Ruxbury - Quick User Guide.indd 62022-09-02 Ruxbury - Quick User Guide.indd 602-09-2022 15:52:0302-09-2022 15:52:03 30 Special Considerations 32 Smartphone considerations 32 Smartwatch integration 33 Disclaimer 33 Compliance 34 Warranty 36 Appendix 1 – push button LED indicator 2022-09-02 Ruxbury - Quick User Guide.indd 72022-09-02 Ruxbury - Quick User Guide.indd 702-09-2022 15:52:0302-09-2022 15:52:03 8 2022-09-02 Ruxbury - Quick User Guide.indd 82022-09-02 Ruxbury - Quick User Guide.indd 802-09-2022 15:52:0402-09-2022 15:52:04 9 Ruxbury Equestrian Heart Rate and Motion Monitor is the ultimate fitness tracker for horses. Use it to... • Improve your riding • Keep track of your training • Monitor your horse’s well-being The Ruxbury Monitor can be used for training and for in-box horse monitoring with a user receiving distress notifications. 2022-09-02 Ruxbury - Quick User Guide.indd 92022-09-02 Ruxbury - Quick User Guide.indd 902-09-2022 15:52:0502-09-2022 15:52:05 10 Features Easy to mount and operate Ruxbury EM1 sensor for measuring and logging horse heart rate and motion, attaching to a head collar using the included sleeve with an integrated elastic strap. • Dual use: Training or well-being monitoring, training metrics indicate fitness and performance level, Well- being monitoring detects unusual conditions (e.g., colic, foaling) using the heart rate and motion. • Distress notifications • Route tracking • Built-in rechargeable battery (up to 5 days x 24 hours for training, up to 15 days x 24 hours for monitoring) 2022-09-02 Ruxbury - Quick User Guide.indd 102022-09-02 Ruxbury - Quick User Guide.indd 1002-09-2022 15:52:0502-09-2022 15:52:05 11 • One button EM1 sensor operation (on, off, battery status) with integrated LED indicator (power on/off, ready to connect, connected, software update) The Ruxbury EM1 sensor is designed for over-the-air software update by the user. Ruxbury may from time to time introduce new features by means of software update. Check www.ruxbury.com. You shall provide the following items • Smartphone. Download Ruxbury App available for iOS and Android phones. • Head collar or bridle for your horse. You may optionally use a girth to mount the sensor on horse’s belly. 2022-09-02 Ruxbury - Quick User Guide.indd 112022-09-02 Ruxbury - Quick User Guide.indd 1102-09-2022 15:52:0502-09-2022 15:52:05 12 Check www.ruxbury.com for replacement protective sleeves, software updates for EM1 sensor device and information about new app versions. Operating the Ruxbury EM1 sensor Push button and LED light The Ruxbury sensor shall be used with a smartphone app. Therefore, you shall have your smartphone near the sensor, typically within 10-20 meters. You operate the Ruxbury sensor using a button with an integrated LED indicator. There are two gestures – a long press and a short tap: 2022-09-02 Ruxbury - Quick User Guide.indd 122022-09-02 Ruxbury - Quick User Guide.indd 1202-09-2022 15:52:0502-09-2022 15:52:05 13 • Power on – short tap, indicated by a red blink, followed by a slow blue blink • Power off – long press (>3 seconds), indicated by a long red light You can also see an approximate battery level indication 2022-09-02 Ruxbury - Quick User Guide.indd 132022-09-02 Ruxbury - Quick User Guide.indd 1302-09-2022 15:52:0502-09-2022 15:52:05 14 by a short tap when the Ruxbury sensor is turned on: • 1 green flash – less than 25% battery capacity left • 2 green flashes – between 25% and 75% battery capacity left • 3 green flashes – more than 75% battery capacity left The push button gestures, their functions and LED indications are described in Appendix 1. Charging Observe the following precautions when charging the Ruxbury sensor: • Do not charge the device while the Ruxbury sensor is 2022-09-02 Ruxbury - Quick User Guide.indd 142022-09-02 Ruxbury - Quick User Guide.indd 1402-09-2022 15:52:0502-09-2022 15:52:05 15 mounted on a horse • Ensure that the temperature in the location where you charge is above 10 degrees Celsius / 50 degrees Fahrenheit and below 40 degrees Celsius / 104 degrees Fahrenheit Please note, that there is no need to remove the protective sleeve to charge the Ruxbury sensor. 2022-09-02 Ruxbury - Quick User Guide.indd 152022-09-02 Ruxbury - Quick User Guide.indd 1502-09-2022 15:52:0602-09-2022 15:52:06 16 Use a fingernail to open the rubber lid covering the USB port on the sensor’s long side and plug in the provided micro-USB cable. Make sure a proper orientation of the cable towards the USB port. The Ruxbury sensor turns on when power is applied to the USB port. The charging state is indicated by a slow green blink. Mounting the Ruxbury sensor device on a horse You shall set up a head collar or bridle for a horse. The elastic strap will fit any head collar. Mount the Ruxbury se…
Text truncated - open the document above for the full version.
Ruxbury ApS c/o Zenegy ApS - Slotsmarken 16, 2970 Hørsholm, Denmark Date: 06-29-2023 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Ref: Attestation Statements Part 2.911(d)(5)(i) and Part 2.911(d)(5)(ii) Filing Re. KDB 986446 D01 FCC ID: 2A38W-RX0101 Dear Sir or Madam, Ruxbury ApS (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, the applicant [is / is not] identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please contact us. Sincerely, Contact name: Tomasz Goldman Company name: Ruxbury ApS Address: C/O Zenegy, Slotsmarken 16, 2970 Hørsholm, Denmark E-mail: [email protected] or [email protected] Tel: +45 40 68 61 98
Ruxbury ApS c/o Zenegy ApS - Slotsmarken 16, 2970 Hørsholm, Denmark Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 06/29/2023 Ref: Attestation Statement Part 2.911(d)(7) Filing Validity Period: Permanent FCC ID: 2A38W-RX0101 Manufacturer Name Ruxbury ApS Address Slotsmarken 16, Hørsholm, 2970 Denmark certifies that, as of the dates of this application, Americas Compliance Consulting LLC dba iCertifi “iCertifi” is our designated U.S. agent for service of process for the above referenced FCC ID. We accept to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission- related proceeding involving the equipment. The US Agent for Service of Process is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. iCertifi accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service process for the above: Designated U.S. Agent Information: Name Americas Compliance Consulting, LLC dba iCertifi FCC FRN 0033399411 Address 1001 SW Disk Drive, Suite 250 Bend, Oregon 97702 USA Contact Person Paul Preston Telephone (866) 885-4575 Email [email protected] Sincerely, Ruxbury ApS Americas Compliance Consulting LLC dba iCertifi Tomasz Goldman Paul Preston Page 1
Pictures of EM1 Title: EM1 seen at different angles Project: No: S400270 Page: 1 of 1 Placement: Pictures of EM1 Date: 2023.03.21 Version: 0.0.1 File name: Pictures of EM1.docx Author: to: ADE Replaces: - Doc. No: N/A Develco A/S Hedeager 40 t: +45 87 400 300 develco.dk DK-8200 Aarhus N e: [email protected] EM1 seen at different angles Without strap With Strap
TÜV SÜD, Octagon House, Concorde Way, Segensworth North, Fareham, Hampshire, United Kingdom, PO15 5RL Tel: +44 (0) 1489 558100 Website: www.tuvsud.com/en COMMERCIAL-IN-CONFIDENCE SAR EXCLUSION DOCUMENT Approved by Date 11 February 2022 Matt Russell Authorised Signatory ©2022 Not to be reproduced, except in its entirety, without the permission of TÜV SÜD Page 1 of 3 Document 75954061-09 Issue 01 2400 MHz Transmitter: FCC General RF Exposure Test Exemption Guidance (KDB 447498 D04 v01 Appendix B) SAR or MPE based evaluation is not required if any of the applicable Steps 1, 2 or 3 are met (Ref: KDB 447448 Figure A.1). Step 1: All Devices: Blanket 1 mW Exemption (100 kHz – 100 GHz) Reference: FCC CFR 47 Part 1.1307(b)(3)(i)(A). Frequency (MHz) Conducted Power Output mW Duty Cycle % Time Average Conducted Power Output mW Antenna Gain Ratio Maximum Power (EIRP) mW Maximum Power (ERP) mW Test Separation Distance (mm) All devices: 1.1307(b)(3)(i)(A) Blanket 1 mW Exemption (Yes/No)* (100 kHz to 100 GHz) 2402 3.2 32 1.024 1.5849 1.6229376 0.99 10 No 2480 3.2 32 1.024 1.5849 1.6229376 0.99 10 No *Based on conducted power output or ERP whichever is greater, compared to the 1 mW exemption threshold. Step 2: All devices: MPE Exemption (300 kHz to 100 GHz) Reference: FCC CFR 47 Part 1.1307(b)(3)(i)(C). Frequency (MHz) Conducted Power Output mW Duty Cycle % Time Average Conducted Power Output mW Antenna Gain Ratio Maximum Power (EIRP) mW Maximum Power (ERP) mW Test Separation Distance (mm) Threshold ERP at separation distance R (mW) All devices: 1.1307(b)(3)(i)(C) MPE Exemption (Yes/No)** (300 kHz to 100 GHz) 2402 3.2 32 1.024 1.5849 1.6229376 0.99 10 1.92 No (See Note) 2480 3.2 32 1.024 1.5849 1.6229376 0.99 10 1.92 No (See Note) Note: Minimum distance (λ/2π) calculated as 19.8 mm which is greater than test separation distance therefore exclusion cannot be applied. **Based on ERP compared to the KDB 447498 Table B.1 Threshold ERP calculated for the separation distance R. TÜV SÜD, Octagon House, Concorde Way, Segensworth North, Fareham, Hampshire, United Kingdom, PO15 5RL Tel: +44 (0) 1489 558100 Website: www.tuvsud.com/en COMMERCIAL-IN-CONFIDENCE SAR EXCLUSION DOCUMENT ©2022 Not to be reproduced, except in its entirety, without the permission of TÜV SÜD Page 2 of 3 Step 3: All Devices: (if Step 1 & 2 not met): SAR Exemption (300 MHz to 6 GHz, 0.5 cm to 40 cm) Reference: FCC CFR 47 Part 1.1307(b)(3)(i)(B). Frequency (MHz) Conducted Power Output mW Duty Cycle % Time Average Conducted Power Output mW Antenna Gain Ratio Maximum Power (EIRP) mW Maximum Power (ERP) mW Test Separation Distance (mm) Threshold Pth (mW) All devices: 1.1307(b)(3)(i)(B) SAR Exemption (Yes/No)* (300 MHz to 6 GHz, 0.5 cm to 40 cm) 2405 3.2 32 1.024 1.5849 1.6229376 0.99 10 5.6 Yes 2480 3.2 32 1.024 1.5849 1.6229376 0.99 10 5.6 Yes *Based on conducted power output or ERP whichever is greater, compared to the Pth KDB 447498 B.2 formula;. The SAR and MPE exclusion thresholds have been evaluated using the formula described above from information supplied by the manufacturer below. Based on the calculations above, the product is categorically excluded from SAR or MPE evaluation. ©2022 Not to be reproduced, except in its entirety, without the permission of TÜV SÜD Page 3 of 3 Document Number: 759XXXXX-XX | Issue: 01 COMMERCIAL-IN-CONFIDENCE Manufacturer’s Declaration of Product information: Equipment Description Technical Description: (Please provide a brief description of the intended use of the equipment) Heart Rate and Motion Monitor for Horses with BLE communication for transmitting data to a SmartPhone. Manufacturer: Ruxbury ApS Model: EM1 Part Number: RX-0101 If more than one frequency band is supported, please confirm which combinations of bands are capable of Simultaneous Transmit. Frequency Band 1: Please detail (one entry for each band), e,g GSM 900 / WCDMA FDD I etc . Antenna Model: Built-in F-antenna Antenna length: 0,2 cm Bottom frequency: 2402 MHz Middle frequency: 2440 MHz Top frequency: 2480 MHz Maximum power (input to the antenna including a tolerance): 5 dBm Antenna gain (or maximum gain allowed): 2 dBi Or Field Strength Measurement: dBμA/M Measurement Distance: cm Separation distance from antenna to the user/bystander 1 cm Transmitter Duty Cycle: 32 %
TÜV SÜD is a trading name of TUV SUD Ltd Registered in Scotland at East Kilbride, Glasgow G75 0QF, United Kingdom Registered number: SC215164 TUV SUD Ltd is a TÜV SÜD Group Company Phone: +44 (0) 1489 558100 Fax: +44 (0) 1489 558101 www.tuvsud.com/en TÜV SÜD Octagon House Concorde Way Fareham Hampshire PO15 5RL United Kingdom TÜV SÜD SIGNATURE NAME JOB TITLE RESPONSIBLE FOR ISSUE DATE Steve Marshall Senior Engineer Authorised Signatory 24 May 2022 Signatures in this approval box have checked this document in line with the requirements of TÜV SÜD document control rules. ENGINEERING STATEMENT The measurements shown in this report were made in accordance with the procedures described on test pages. All reported testing was carried out on a sample equipment to demonstrate limited compliance with FCC 47 CFR Part 15C, ISED RSS-247 and ISED RSS-GEN. The sample tested was found to comply with the requirements defined in the applied rules. RESPONSIBLE FOR NAME DATE SIGNATURE Testing Paul Dickson 24 May 2022 Testing Graeme Lawler 24 May 2022 Testing Daniel Cameron 24 May 2022 FCC Accreditation 90987 Octagon House, Fareham Test Laboratory ISED Accreditation 12669A Octagon House, Fareham Test Laboratory EXECUTIVE SUMMARY A sample of this product was tested and found to be compliant with FCC 47 CFR Part 15C: 2020, ISED RSS-247: Issue 2 (02- 2017) and ISED RSS-GEN: Issue 5 (04-2018) + A2 (02-2021) for the tests detailed in section 1.3. FCC and ISED Test Report Ruxbury ApS Model: EM1 In accordance with FCC 47 CFR Part 15C, ISED RSS-247 and ISED RSS-GEN (2.4 GHz Bluetooth Low Energy) Prepared for: Ruxbury ApS C/O Zenegy Slotsmarken 16, 2970 Hørsholm Denmark FCC ID: 2A38W-RX0101 IC: 28175-RX0101 COMMERCIAL-IN-CONFIDENCE Document 75954061-05 Issue 01 DISCLAIMER AND COPYRIGHT This non-binding report has been prepared by TÜV SÜD with all reasonable skill and care. The document is confidential to the potential Client and TÜV SÜD. No part of this document may be reproduced without the prior written approval of TÜV SÜD. © 2022 TÜV SÜD. This report relates only to the actual item/items tested. ACCREDITATION Our UKAS Accreditation does not cover opinions and interpretations and any expressed are outside the scope of our UKAS Accreditation. Results of tests not covered by our UKAS Accreditation Schedule are marked NUA (Not UKAS Accredited). Document 75954061-05 Issue 01 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE Page 1 of 79 Contents 1 Report Summary .........................................................................................................................2 1.1 Report Modification Record ...........................................................................................................2 1.2 Introduction ....................................................................................................................................2 1.3 Brief Summary of Results .............................................................................................................3 1.4 Application Form ...........................................................................................................................4 1.5 Product Information .......................................................................................................................7 1.6 Deviations from the Standard ........................................................................................................7 1.7 EUT Modification Record ..............................................................................................................7 1.8 Test Location .................................................................................................................................8 2 Test Details ..................................................................................................................................9 2.1 Restricted Band Edges..................................................................................................................9 2.2 AC Power Line Conducted Emissions ....................................................................................... 13 2.3 Emission Bandwidth ................................................................................................................... 17 2.4 Maximum Conducted Output Power .......................................................................................... 23 2.5 Spurious Radiated Emissions .................................................................................................... 26 2.6 Authorised Band Edges ............................................................................................................. 61 2.7 Power Spectral Density .............................................................................................................. 65 3 Photographs ............................................................................................................................. 68 3.1 Test Setup Photographs ............................................................................................................ 68 4 Measurement Uncertainty ....................................................................................................... 79 Document 75954061-05 Issue 01 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE Page 2 of 79 1 Report Summary 1.1 Report Modification Record Alterations and additions to this report will be issued to the holders of each copy in the form of a complete document. Issue Description of Change Date of Issue 1 First Issue 24 May 2022 Table 1 1.2 Introduction Applicant Ruxbury ApS Manufacturer Ruxbury ApS Model Number(s) EM1 Serial Number(s) 00003P, 00002P and 00001P Hardware Version(s) V1.0 Software Version(s) V1.0 Number of Samples Tested 3 Test Specification/Issue/Date FCC 47 CFR Part 15C: 2020 ISED RSS-247: Issue 2 (02-2017) ISED RSS-GEN: Issue 5 (04-2018) + A2 (02-2021) Order Number Date PO-DK-10 09-December-2021 Date of Rece…
Text truncated - open the document above for the full version.
3D Antenna measurement (TRP) Date: October 25th 2022 Test facillity: Room 3 Location: FORCE Technology, Agro Food Park 13, 8200 Aarhus N. Operator: Jesper Salvesen, [email protected], +45 43 25 05 29 (direct) Short-format report. Test item: Heart rate monitor for veterinary use (horse) Sample name: 1 x Specimen_01 1 x Specimen_02 Radio parameters: BT radio in testmode - both samples where set to transmit at 2440MHz in max. power mode (CW) Pictures describing the setup: Setup description: The test system is based on the roll over azimuth method. Room 3 - Anechoic chamber RF Gen. (optional) Spectrum- Analyzer Measurement PC Specimen_01 testresults: OTA Evaluation Results: Total Radiated Power -2,41 dBm Directivity 3,00 dBi Total Efficiency -2,41 dB (Calculated, based 0 dBm conducted power) Total Efficiency 57,43 % (Calculated, based 0 dBm conducted power) Peak Relaized Gain 0,59 dBi NHPRP 45° -4,26 dBm NHPRP 45° / TRP -1,85 dB NHPRP 45° / TRP 65,36 % NHPRP 30° -5,99 dBm NHPRP 30° / TRP -3,58 dB NHPRP 30° / TRP 43,87 % NHPRP 22.5° -7,23 dBm NHPRP 22.5° / TRP -4,83 dB NHPRP 22.5° / TRP 32,92 % UHRP -4,88 dBm UHRP / TRP -2,47 dB UHRP / TRP 56,67 % LHRP -6,04 dBm LHRP / TRP -3,63 dB LHRP / TRP 43,33 % PGRP (0-120°) -3,63 dBm PGRP / TRP -1,22 dB PGRP / TRP 75,54 % Front/Back Ratio 1,36 PhiBW 200,3 deg PhiBW Up 112,2 deg PhiBW Down 88,1 deg ThetaBW 137,9 deg ThetaBW Up 47,5 deg ThetaBW Down 90,4 deg Boresight Phi 135 deg Boresight Theta 45 deg Maximum Power 0,59 dBm Minimum Power -12,21 dBm Average Power -2,09 dBm Max/Min Ratio 12,79 dB Max/Avg Ratio 2,67 dB Min/Avg Ratio -10,12 dB Worst Single Value -20,55 dBm Worst Position Azi = 15 deg; Elev = 75 deg; Pol = Hor Best Single Value 0,16 dBm Best Position Azi = 150 deg; Elev = 45 deg; Pol = Hor Result Table: Azimuth (deg) Elevation 0 deg (dB) Elevation 15 deg (dB) Elevation 30 deg (dB) Elevation 45 deg (dB) Elevation 60 deg (dB) Elevation 75 deg (dB) Elevation 90 deg (dB) Elevation 105 deg (dB) 0.00 -0.84 -0.60 -1.35 -3.25 -3.98 -5.66 -6.22 -5.18 15.00 -0.84 -0.75 -1.52 -3.35 -3.11 -3.74 -4.11 -3.02 30.00 -0.84 -0.90 -1.69 -3.14 -2.00 -2.18 -2.79 -1.91 45.00 -0.84 -1.06 -1.43 -2.57 -1.06 -0.78 -1.99 -1.29 60.00 -0.84 -1.22 -1.19 -1.37 -0.39 -0.01 -1.55 -1.06 75.00 -0.84 -0.90 -0.76 -0.71 -0.01 0.29 -1.16 -1.07 90.00 -0.84 -0.60 -0.36 -0.20 0.09 0.36 -1.25 -1.24 105.00 -0.84 -0.32 -0.04 0.30 0.08 0.33 -1.56 -1.65 120.00 -0.84 -0.06 0.26 0.54 -0.03 -0.01 -1.85 -2.22 135.00 -0.84 -0.04 0.29 0.59 -0.20 -0.48 -2.33 -2.82 150.00 -0.84 -0.02 0.32 0.44 -0.34 -0.89 -2.82 -3.45 165.00 -0.84 -0.01 0.19 0.14 -0.43 -1.21 -2.66 -4.12 180.00 -0.84 0.01 0.04 -0.25 -0.61 -1.55 -3.11 -4.45 195.00 -0.84 -0.21 -0.30 -0.72 -0.58 -1.76 -2.70 -4.50 210.00 -0.84 -0.44 -0.67 -1.22 -0.62 -1.67 -3.22 -4.16 225.00 -0.84 -0.69 -1.06 -1.67 -0.84 -1.54 -3.11 -3.43 240.00 -0.84 -0.95 -1.49 -2.16 -1.26 -1.40 -2.84 -2.96 255.00 -0.84 -0.55 -1.28 -2.69 -1.82 -1.33 -2.67 -2.80 270.00 -0.84 -0.18 -1.08 -2.67 -2.29 -1.87 -3.33 -3.29 285.00 -0.84 0.17 -0.71 -2.47 -3.14 -2.94 -4.85 -4.06 300.00 -0.84 0.48 -0.37 -2.27 -4.25 -4.77 -6.58 -5.77 315.00 -0.84 0.24 -0.42 -2.34 -5.19 -7.66 -10.27 -7.61 330.00 -0.84 -0.03 -0.48 -2.57 -5.55 -10.38 -12.21 -8.77 345.00 -0.84 -0.31 -0.89 -2.88 -5.14 -8.88 -9.67 -7.68 360.00 -0.84 -0.60 -1.35 -3.25 -3.98 -5.66 -6.22 -5.18 Azimuth (deg) Elevation 120 deg (dB) Elevation 135 deg (dB) Elevation 150 deg (dB) Elevation 165 deg (dB) Elevation 180 deg (dB) 0.00 -4.21 -0.65 -0.38 -4.58 -8.45 15.00 -3.35 -0.35 -0.06 -4.44 -8.45 30.00 -2.51 -0.18 0.23 -4.30 -8.45 45.00 -2.02 -0.14 0.12 -4.17 -8.45 60.00 -1.81 -0.27 0.00 -4.05 -8.45 75.00 -1.82 -0.63 -0.38 -3.78 -8.45 90.00 -2.10 -1.22 -0.79 -3.53 -8.45 105.00 -2.82 -2.17 -1.52 -3.30 -8.45 120.00 -3.38 -3.19 -2.41 -3.08 -8.45 135.00 -4.24 -4.34 -2.77 -3.21 -8.45 150.00 -5.30 -5.59 -3.17 -3.35 -8.45 165.00 -5.92 -6.20 -3.46 -3.49 -8.45 180.00 -5.87 -6.14 -3.77 -3.64 -8.45 195.00 -5.60 -5.43 -3.44 -4.22 -8.45 210.00 -4.67 -4.14 -3.14 -4.88 -8.45 225.00 -3.35 -2.63 -2.26 -5.66 -8.45 240.00 -2.28 -1.42 -1.53 -6.61 -8.45 255.00 -1.73 -0.48 -0.98 -6.41 -8.45 270.00 -1.68 -0.10 -0.50 -6.21 -8.45 285.00 -2.21 -0.13 -0.57 -6.02 -8.45 300.00 -3.03 -0.41 -0.65 -5.84 -8.45 315.00 -3.89 -0.77 -0.83 -5.49 -8.45 330.00 -4.59 -0.94 -1.03 -5.16 -8.45 345.00 -4.89 -0.90 -0.69 -4.86 -8.45 360.00 -4.21 -0.65 -0.38 -4.58 -8.45 3D plots: Theta = 90, Phi = 0 Theta = 90, Phi = 90 Theta = 0, Phi = 0 Theta = 90, Phi = 180 Theta = 90, Phi = 270 Theta = 180, Phi = 0 Specimen_02 testresults: OTA Evaluation Results: Total Radiated Power -2,62 dBm Directivity 3,07 dBi Total Efficiency -2,62 dB (Calculated, based 0 dBm conducted power) Total Efficiency 54,72 % (Calculated, based 0 dBm conducted power) Peak Relaized Gain 0,45 dBi NHPRP 45° -4,45 dBm NHPRP 45° / TRP -1,83 dB NHPRP 45° / TRP 65,66 % NHPRP 30° -6,17 dBm NHPRP 30° / TRP -3,55 dB…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output | Emission |
|---|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 3.20 mW | F7D |