Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
TFT Display Explanation 12 10 11 12 13 14 15 16 34567 8 9 ① ② ③ ④ ⑤ ⑥ ⑨ ⑦ ⑧ Battery Indicator Sound Icon Wireless Connection Icon Time Icon Blood Pressure Out of Range Date Icon Cuff Wrap Guide: Correct User Icon Normal Blood Pressure 10 12 13 14 15 11 16 Movement Error Systolic Blood Pressure Test Again Diastolic Blood Pressure Irregular Pulse Pulse Rate Icon Recent 3 Blood Pressure Readings Screen rotation diagram 1. Safety Instructions Thank you for purchasing Runstar Arm-type Electronic Blood Pressure Monitor. Please read this instruction manual carefully before use. This device is not a direct diagnostic device. It is only suitable for monitoring the blood pressure and pulse rate of adults. The measurement results should not be used for self-diagnosis or treatment. Please follow your doctor's advice. Blood pressure is an important indicator of the human circulatory system. The home blood pressure monitor is easy to use regularly. It is crucial for preventing cardiovascular disease, encouraging hypertension patients to seek treatment, and managing high blood pressure. Blood pressure fluctuates continuously throughout the day and night. The highest values typically occur during the day and the lowest at midnight. It is recommended that you measure your blood pressure at roughly the same time each day. Various activities such as physical exercise, excitement, stress, eating, drinking, smoking, body posture, and other factors (including taking a blood pressure measurement) can influence blood pressure readings. Due to these factors, it is uncommon to obtain identical blood pressure readings in multiple measurements. Definition and Classification of Blood Pressure Levels from WHO-ISH Classification Ideal Blood Pressure Normal Blood Pressure High Normal Hypertension GradeI(Slight) Hypertension GradeII(Medium) Hypertension GradeIII(Serious) Isolated Systolic Hypertension <120 <130 130~139 140~159 160~179 ≥180 ≥140 Systolic Pressure (mmHg) <80 <85 85~89 90~99 100~109 ≥110 <90 Diastolic Pressure (mmHg) 2 The information above is for reference only. 1.1 Warning: This product is intended for daily blood pressure monitoring only and should not be used for diagnosing hypertension. CONTENTS 1 ● Use this product only for blood pressure measurements. Using it for other purposes may lead to accidents. ● This device is suitable for use by adults only. Do not use it on infants, toddlers, children or individuals who cannot express themselves. ● Self-diagnosis and treatment based on blood pressure readings are not recommended. Consult healthcare professionals for proper evaluation and guidance. ● Patients with severe blood pressure or circulation disorders, as well as blood diseases, should use this device under medical supervision. ● The displayed pulse reading used as medical heart rate should not be monitoring. ● Patients with arrhythmia or arteriosclerosis should have their blood pressure readings confirmed by medical professionals. ● Do not apply the cuff on limbs with intravascular access, therapy, or arterio- venous shunts to prevent blood flow interference and patient injury. ● Do not use the cuff on an injured or operated arm to prevent further harm. ● In the presence of common arrhythmias, such as premature beats or atrial fibrillation, the accuracy of the readings may be affected. ● Keep the device away from any great power appliances (e.g. high-voltage equipment, X-ray machine, and ultrasound equipment, etc.) to prevent interference during use. ● Keep the device away from active HF surgical equipment, MRI system and RF shielded rooms which generate strong electromagnetic interference. ● Keep the device away from strong electromagnetic fields (e.g. near the mobile power supply, microwave oven, etc.), as it may affect accuracy. ● Do not submerge the device in water or any liquids. ● Do not use the device near flammable anesthetic mixtures. ● Do not stack this device with other equipment to prevent operational issues. ● Keep batteries away from fire and out of reach of children and pets. 1.2 Caution - For best results, practice multiple times to become familiar with the measurement technique. - Inspect the device for any damage before use, especially the cuff. Do not use if damaged to avoid skin injury. - Verify the device is in proper working condition before use. - Do not inflate the cuff when not properly wrapped around the arm. - If cuff pressure causes discomfort, stop the measurement immediately by pressing the "START/STOP" button to release pressure, and remove the cuff. - Inaccurate measurement values may occur due to unconscious mis-operation. Instruction Manual Electronic Blood Pressure Monitor Model: BP-202 1. Safety Instructions................................................................................2 2. Working Principle..................................................................................4 3. Intended Purpose.................................................................................4 4. Product Introduction.............................................................................4 5. Product Structures................................................................................5 6. Symbol Explanation..............................................................................7 7. Product Specification............................................................................8 8. Settings................................................................................................9 9. Blood Pressure Measurement Method.................................................11 10. Error and Fault Troubleshooting.........................................................13 11. Maintenance and Cleaning.................................................................14 12. Product Charging...............................................................................15 13. After-sale Service.......................................................................…
Text truncated - open the document above for the full version.
LocalRepresentativeLetter ForCertificationServiceintheUSA FederalCommunicationsCommission EquipmentAuthorizationDivision,ApplicationProcessingBranch 7435OaklandMillsRoad Columbia,MD21048 Towhomitmayconcern PursuanttoSection2.911(d)(7),oftheCommission’sRules(47C.F.R.)weattestasfollowsfor theproductlistedbelow: FCCIDModelname 2A39J-BP202BP202 Weherebyacknowledgeasfollows: i.bothsigneesconfirmthatthepointofcontactacceptsresponsibilitytoactasaUS- AmericanRepresentativeonbehalfoftheapplicant ii.thepointofcontactprovidesthephysicalU.S.addressandemailaslistedbelow iii.bothpartiesmaintaintherequirementsofthisagreementwithoutexpirationdate US-AmericanPointofContactApplicant/ApprovalHolder SignatureSignature CompanyName:FCCUSAgent,LLCShenzhenBravElectronic TechnologiesCo.,Ltd FRN:00334028840031836075 ContactName:TimPayneyiYang Address:3722IllinoisAvenue,SaintCharles, IL,60174,USA 4-5/F,Building11,Tongfuyu Industrial Park,Lezhujiao,Huangmabu Community,Hangcheng street,Bao'anDistrict,Shenzhen Phone:708-571-31480755-29781489 Email:[email protected]@qq.com
Covered Equipment Attestation Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2A39J-BP202 BP-202 We, Applicant Company Name: Shenzhen Brav Electronic Technologies Co., Ltd Address: 4-5/F, Building 11, Tongfuyu Industrial Park, Lezhujiao, Huangmabu Community, Hangcheng street, Bao'an District, Shenzhen, China Phone: +86-755-29781489 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. This includes the cybersecurity and anti-virus software produced or provided by Kaspersky Lab, Inc. or any of ist successors and assignees. We certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2026-09-16 Signature Date Name / Title: Yi Yang / Manager Company: Shenzhen Brav Electronic Technologies Co., Ltd Address: 4-5/F, Building 11, Tongfuyu Industrial Park, Lezhujiao, Huangmabu Community, Hangcheng street, Bao'an District, Shenzhen, China Phone: +86-755-29781489 Fax: N/A E-Mail: [email protected]
Due Diligence Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern FCC ID Model name 2A39J-BP202 BP-202 Pursuant to KDB 986446 D01 Covered Equipment Guidance the evaluation of the product above shows compliance for the following reasons: Compliance Evaluation process Results Inherent compliance The chipset(s) used is not capable of running the cybersecurity and/or anti-virus software Compliance The memory used does not allow the running the cybersecurity and/or anti-virus software Compliance The storage capacity does not allow the running the cybersecurity and/or anti-virus software Compliance The operating system used is not capable of running the cybersecurity and/or anti-virus software Compliance No inherent compliance Based on software bill of material Based on scan for running software on the device Based on filesystem scan for cybersecurity and/or anti-virus software The equipment for which authorization is sought complies with the rules and fulfils the requirements as detailed in the above mentioned KDB. Evaluation performed by Company Name: Shenzhen Global Test Service Co., Ltd. Contact Name: Peter Xiao Address: Room No. 101, Building 1, and Room No. 101, Building 3, No. 88 Jinkang Road, Jinsha Community, Kengzi Sub-district, Pingshan District, Shenzhen City, Guangdong, China Phone: +86-755-28717088 Email: [email protected] Date: 2026-09-10 Signature:
Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2A39J-BP202 BP-202 For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Part List • the Tune up Procedure The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2026-09-16 Signature Date Name / Title: Yi Yang / Manager Company: Shenzhen Brav Electronic Technologies Co., Ltd Address: 4-5/F, Building 11, Tongfuyu Industrial Park, Lezhujiao, Huangmabu Community, Hangcheng street, Bao'an District, Shenzhen, China Phone: +86-755-29781489 Fax: N/A E-Mail: [email protected]
FCCID:2A39J-BP202 Fig.1 Fig.2 FCCID:2A39J-BP202 Fig.3 Fig.4 FCCID:2A39J-BP202 Fig.5 Fig.6
_____________________________________________________________________________________________________ LABELANDLOCATION (Size:L4.75cmx2.0cm) LabelLocation
FCCID:2A39J-BP202 Fig.1 Fig.2 FCCID:2A39J-BP202 Fig.3 Fig.4 FCCID:2A39J-BP202 Fig.5 Fig.6 FCCID:2A39J-BP202 Fig.7 Fig.8 FCCID:2A39J-BP202 Fig.9 Fig.10 FCCID:2A39J-BP202 Fig.11 Fig.12 BTANT
ShenzhenGlobalTestServiceCo.,Ltd. RoomNo.101,Building1,andRoomNo.101,Building3,No.88JinkangRoad,JinshaCommunity, KengziSub-district,PingshanDistrict,ShenzhenCity,Guangdong,China RFExposureevaluation ReportReferenceNo........................: FCCID..................................................: GTS20260728001-3-02 2A39J-BP202 Compiledby (position+printedname+signature)..:FileadministratorsJinghuaXiao Supervisedby (position+printedname+signature)..:TestEngineerEvanOuyang Approvedby (position+printedname+signature) .. : ManagerJasonHu Dateofissue.........................................:Sep.10,2026 RepresentativeLaboratoryName . :ShenzhenGlobalTestServiceCo.,Ltd. Address ................................................. : RoomNo.101,Building1,andRoomNo.101,Building3,No.88 JinkangRoad,JinshaCommunity,KengziSub-district,Pingshan District,ShenzhenCity,Guangdong,China Applicant’sname...............................:ShenzhenBravElectronicTechnologiesCo.,Ltd Address ................................................. : 4-5/F,Building11,TongfuyuIndustrialPark,Lezhujiao,Huangmabu Community,Hangchengstreet,Bao'anDistrict,Shenzhen,China Testspecification .............................. : Standard................................................: 47CFR § 1.1310 47CFR§2.1093 KDB447498D01GeneralRFExposureGuidancev06 TRFOriginator ...................................... :ShenzhenGlobalTestServiceCo.,Ltd. MasterTRF ........................................... :Dated2014-12 ShenzhenGlobalTestServiceCo.,Ltd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenGlobalTestServiceCo.,Ltd.isacknowledgedascopyrightownerandsourceofthematerial. ShenzhenGlobalTestServiceCo.,Ltd.takesnoresponsibilityforandwillnotassumeliabilityfordamages resultingfromthereader'sinterpretationofthereproducedmaterialduetoitsplacementandcontext. Testitemdescription ........................ :ElectronicBloodPressureMonitor TradeMark ............................................ :N/A Manufacturer.........................................: ShenzhenBravElectronicTechnologiesCo.,Ltd Model/Typereference.........................:BP-202 ListedModels ...................................... :N/A Exposurecategory...............................:Generalpopulation/uncontrolledenvironment EUTType..............................................:Portable HardwareVersion...............................:N/A SoftwareVersion .................................. :N/A Rating.....................................................:DC3.7VFrombatteryandDC5.0VFromadapter Result.....................................................:PASS ReportNo.:GTS20260728001-3-02Page 2 of 7 TESTREPORT TestReportNo.: GTS20260728001-3-02 Sep.10,2026 ______________________________________________________________________________________________ Dateofissue EquipmentunderTest:ElectronicBloodPressureMonitor Model/Type:BP-202 Listedmodel:N/A Applicant : ShenzhenBravElectronicTechnologiesCo.,Ltd Address : 4-5/F,Building11,TongfuyuIndustrialPark,Lezhujiao, HuangmabuCommunity,Hangchengstreet,Bao'anDistrict, Shenzhen,China Manufacturer : ShenzhenBravElectronicTechnologiesCo.,Ltd Address : 4-5/F,Building11,TongfuyuIndustrialPark,Lezhujiao, HuangmabuCommunity,Hangchengstreet,Bao'anDistrict, Shenzhen,China TestResult:PASS Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetest laboratory. ReportNo.:GTS20260728001-3-02Page 3 of 7 Contents 1.SUMMARY...............................................................................................................................................4 1.1.ProductDescription....................................................................................................................................4 2.TESTENVIRONMENT.......................................................................................................................5 2.1.Addressofthetestlaboratory...................................................................................................................5 2.2.TestFacility..................................................................................................................................................5 2.3.Environmentalconditions...........................................................................................................................5 2.4.Statementofthemeasurementuncertainty.............................................................................................5 3.METHODOFMEASUREMENT.....................................................................................................6 3.1.ApplicableStandard....................................................................................................................................6 3.2.EvaluationMethodandLimit......................................................................................................................6 4.CONDUCTEDPOWERRESULTS...............................................................................................7 5.MANUFACTURINGTOLERANCE...............................................................................................7 6.EVALUATIONRESULTS.................................................................................................................7 6.1.StandaloneEvaluation................................................................................................................................7 7.CONCLUSION........................................................................................................................................7 ReportNo.:GTS20260728001-3-02Page 4 of 7 1.SUMMARY 1.1.ProductDescription ProductName:ElectronicBloodPressureMonitor TradeMark:N/A Model/Typereference:BP-202 ListModel:N/A ModelDeclarationN/A Powersupply:DC3.7VFrombatteryandDC5.0VFromadapter HardwareVersionN/A SoftwareVersionN/A SampleID GTS20260728001-2-S001-1# GTS20260728001-2-S001-…
Text truncated - open the document above for the full version.
Shenzhen ElinkThingsCo., Ltd - 1 - Tel:(86)0755-81773367 E-mail: [email protected] Address:5th Floor, Qiaohongsheng Park, Yintian Inudstry Area, Xixiang Street, BaoAn District, Shenzhen, 518100 Shenzhen Yilian Internet of Things Co., Ltd. reserves the right to make changes to the specifications and materials contained in it without prior notice, and at the same time damage (including consequential damage) caused by trust in the materials cited, including But not limited to errors in printing and other errors related to this publication, Yilian Internet of Things will not be held responsible. Antenna Specification MODEL:BP-20 2 Version: V2.3 Update Date: September 06,2023 Shenzhen Yilian Internet of Things Co., Ltd. All rights reserved Thespecificationsofthisproductaresubjecttochangewithoutnotice. Shenzhen ElinkThingsCo., Ltd - 1 - Tel:(86)0755-81773367 E-mail: [email protected] Address:5th Floor, Qiaohongsheng Park, Yintian Inudstry Area, Xixiang Street, BaoAn District, Shenzhen, 518100 Contents Contents...................................................................................................................................................................................-1- 1Antennasize ( Unit : mm ) .................................................................................................................................................-1- 2Antennaspecificationparameters........................................................................................................................................-1- 3Testcondition........................................................................................................................................................................-2- 4Testingenvironment..............................................................................................................................................................-3- 5Deoningfrequencyofantennanetwork...............................................................................................................................-5- 6Antennatestefficiency.........................................................................................................................................................-5- 72Dfig(2450MHz)...................................................................................................................................................................-6- 83Dfig.....................................................................................................................................................................................-7- Shenzhen ElinkThingsCo., Ltd - 1 - Tel:(86)0755-81773367 E-mail: [email protected] Address:5th Floor, Qiaohongsheng Park, Yintian Inudstry Area, Xixiang Street, BaoAn District, Shenzhen, 518100 1 Antennasize ( Unit : mm ) 2 Antennaspecificationparameters numberParameter itemDescription 1Center operating frequency2441MHz 2Work bandwidth2400---2480Mhz 3Rate of data signalling1Mbps 4Antenna typeOn-board PCB antenna (default) 5Antenna gain-1.09dBi 6Impedance50ohm 7Modem typeGFSK BM16 Shenzhen ElinkThingsCo., Ltd - 2 - Tel:(86)0755-81773367 E-mail: [email protected] Address:5th Floor, Qiaohongsheng Park, Yintian Inudstry Area, Xixiang Street, BaoAn District, Shenzhen, 518100 3 Testcondition Test engineerJesse Guan Phone(+86)18975824147 [email protected] ConfirmJoy Zhu Date2023/9/5 Shenzhen ElinkThingsCo., Ltd - 3 - Tel:(86)0755-81773367 E-mail: [email protected] Address:5th Floor, Qiaohongsheng Park, Yintian Inudstry Area, Xixiang Street, BaoAn District, Shenzhen, 518100 4 Testingenvironment Shenzhen ElinkThingsCo., Ltd - 4 - Tel:(86)0755-81773367 E-mail: [email protected] Address:5th Floor, Qiaohongsheng Park, Yintian Inudstry Area, Xixiang Street, BaoAn District, Shenzhen, 518100 Shenzhen ElinkThingsCo., Ltd - 5 - Tel:(86)0755-81773367 E-mail: [email protected] Address:5th Floor, Qiaohongsheng Park, Yintian Inudstry Area, Xixiang Street, BaoAn District, Shenzhen, 518100 5 Deoningfrequencyofantennanetwork The return loss of the antenna at 2.445ghz is - 30dB and the impedance is about 50. Bandwidth 80m 6 Antennatestefficiency passive test for 2.4g Freq(MHz)Gain(dBi)Efficiency(dB)Efficiency(%) 2400-2.125670268-6.51298217822.32039018 2410-1.839793728-6.35055515823.17098436 2420-1.64029678-6.24681065523.7311582 2430-1.328848956-5.92515296425.5555189 2440-1.132319256-5.79955308526.30538676 2450-1.087960046-5.84929926526.00579133 2460-1.316358881-6.00672172325.08001707 2470-1.579335991-6.24506749923.74068524 2480-1.962892418-6.45421219322.62448909 Shenzhen ElinkThingsCo., Ltd - 6 - Tel:(86)0755-81773367 E-mail: [email protected] Address:5th Floor, Qiaohongsheng Park, Yintian Inudstry Area, Xixiang Street, BaoAn District, Shenzhen, 518100 2490-2.50538583-6.75344940721.11811056 2500-3.031894388-7.25223622418.8267943 7 2Dfig(2450MHz) ( 1 ) XY-Plane ( 2 ) ZY-Plane ( 3 ) ZX-Plane 3 1 2 Shenzhen ElinkThingsCo., Ltd - 7 - Tel:(86)0755-81773367 E-mail: [email protected] Address:5th Floor, Qiaohongsheng Park, Yintian Inudstry Area, Xixiang Street, BaoAn District, Shenzhen, 518100 8 3Dfig
FCCID:2A39J-BP202 1 CaseNo.:GTS20260728001-3-01 AmbientCondition:25°C,49%RH AccordingStandard:■Part15C TestDate:2026.8.20-2026.9.09TestEngineer:Evanouyang AppendixA.1:DTSBandwidth TestResult TestModeAntennaFreq(MHz) DTSBW [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict BLEAnt1 24020.6802401.7082402.3880.5PASS 24400.6842439.6002440.2840.5PASS 24800.6682479.4762480.1440.5PASS FCCID:2A39J-BP202 2 TestGraphs BLE_Ant1_2402 BLE_Ant1_2440 BLE_Ant1_2480 FCCID:2A39J-BP202 3 FCCID:2A39J-BP202 4 AppendixA.2:OccupiedChannelBandwidth TestResult TestModeAntennaFreq(MHz) OCB[MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict BLEAnt1 24020.999952401.54992402.5498------ 24401.01662439.43582440.4524------ 24801.02302479.30002480.3230------ FCCID:2A39J-BP202 5 TestGraphs BLE_Ant1_2402 BLE_Ant1_2440 BLE_Ant1_2480 FCCID:2A39J-BP202 6 FCCID:2A39J-BP202 7 AppendixA.3:Maximumconductedoutputpower TestResult TestModeAntennaFreq(MHz) ConductedPeak Powert[dBm] Conducted Limit[dBm] Verdict BLEAnt1 24024.08≤30PASS 24404.36≤30PASS 24804.57≤30PASS FCCID:2A39J-BP202 8 AppendixA.4:Maximumpowerspectraldensity TestResult TestModeAntennaFreq(MHz)Result[dBm/3kHz]Limit[dBm/3kHz]Verdict BLEAnt1 2402-7.67≤8.00PASS 2440-7.70≤8.00PASS 2480-7.73≤8.00PASS FCCID:2A39J-BP202 9 TestGraphs BLE_Ant1_2402 BLE_Ant1_2440 BLE_Ant1_2480 FCCID:2A39J-BP202 10 FCCID:2A39J-BP202 11 AppendixA.5:Bandedgemeasurements TestResult TestMod e Antenn a ChNam e Freq(MHz ) RefLevel[dBm ] Result[dBm ] Limit[dBm ] Verdic t BLEAnt1 Low24023.89-48.21≤-16.11PASS High24804.48-45.5≤-15.53PASS FCCID:2A39J-BP202 12 TestGraphs BLE_Ant1_Low_2402 BLE_Ant1_High_2480 FCCID:2A39J-BP202 13 AppendixA.6:ConductedSpuriousEmission TestResult TestModeAntennaFreq(MHz) FreqRange [MHz] RefLevel [dBm] Result[dBm]Limit[dBm]Verdict BLEAnt1 2402 Reference3.883.88---PASS 30~10003.88-61.58≤-16.12PASS 1000~265003.88-43.02≤-16.12PASS 2440 Reference4.174.17---PASS 30~10004.17-61.35≤-15.83PASS 1000~265004.17-43.95≤-15.83PASS 2480 Reference4.314.31---PASS 30~10004.31-61.68≤-15.69PASS 1000~265004.31-43.27≤-15.69PASS FCCID:2A39J-BP202 14 TestGraphs BLE_Ant1_2402_0~Reference BLE_Ant1_2402_30~1000 BLE_Ant1_2402_1000~26500 FCCID:2A39J-BP202 15 BLE_Ant1_2440_0~Reference BLE_Ant1_2440_30~1000 FCCID:2A39J-BP202 16 BLE_Ant1_2440_1000~26500 BLE_Ant1_2480_0~Reference BLE_Ant1_2480_30~1000 FCCID:2A39J-BP202 17 BLE_Ant1_2480_1000~26500 FCCID:2A39J-BP202 18 AppendixA.7:DutyCycle TestResult TestModeAntennaFreq(MHz) ON Time [ms] Period [ms] XDC [%] Duty Cycle Factor[dB] 1/T Factor[KHz] BLEAnt1 24022.192.270.964896.480.160.46 24402.192.270.964896.480.160.46 24802.182.270.960496.040.180.46 FCCID:2A39J-BP202 19 TestGraphs BLE_Ant1_2402 BLE_Ant1_2440 BLE_Ant1_2480 FCCID:2A39J-BP202 20 FCCID:2A39J-BP202 21 AppendixA.8:EmissionsinRestrictedBands TestResult TestModeAntennaChName Freq(MH z) Detector Freq [MHz] Result [dBm] Limit [dBm] Result [dBuV/m] Limit [dBuV/m] Verdict BLEAnt1 Low2402 AV2310.000-49.75≤-41.2045.45≤54PASS AV2338.115-46.09≤-41.2049.11≤54PASS AV2390.000-49.35≤-41.2045.85≤54PASS Peak2310.000-42.87≤-21.2052.33≤74PASS Peak2338.010-39.24≤-21.2055.96≤74PASS Peak2390.000-43.1≤-21.2052.10≤74PASS High2480 AV2483.500-48.01≤-41.2047.19≤54PASS AV2495.760-47.9≤-41.2047.30≤54PASS AV2500.000-48.76≤-41.2046.44≤54PASS Peak2483.500-41.13≤-21.2054.07≤74PASS Peak2492.480-39.61≤-21.2055.59≤74PASS Peak2500.000-41.4≤-21.2053.80≤74PASS Note: 1.TheAntennaGainiscompensatedinthegraph. 2.TheDutyCycleFactorandRBWFactoriscompensatedinthegraph. 3.ThelimitindBmforaveragedetectorisconversionfrom54dBuV/m,accordingto15.209(a).Thelimit indBmforpeakdetectoris20dBabovethelimitofaveragedetectorindBm. FCCID:2A39J-BP202 22 TestGraphs BLE_Ant1_Low_2402_AV BLE_Ant1_Low_2402_Peak BLE_Ant1_High_2480_AV FCCID:2A39J-BP202 23 BLE_Ant1_High_2480_Peak
ShenzhenGlobalTestServiceCo.,Ltd. RoomNo.101,Building1,andRoomNo.101,Building3,No.88JinkangRoad,JinshaCommunity, KengziSub-district,PingshanDistrict,ShenzhenCity,Guangdong,China FCCPART15SUBPARTCTESTREPORT FCCPART15.247 ReportReferenceNo........................: FCCID.................................................: GTS20260728001-3-01 2A39J-BP202 Compiledby (position+printedname+signature) .. :FileadministratorsJinghuaXiao Supervisedby (position+printedname+signature) .. :TestEngineerEvanOuyang Approvedby (position+printedname+signature)..: ManagerJasonHu Dateofissue.........................................:Sep.10,2026 RepresentativeLaboratoryName.:ShenzhenGlobalTestServiceCo.,Ltd. Address ................................................. : RoomNo.101,Building1,andRoomNo.101,Building3,No.88 JinkangRoad,JinshaCommunity,KengziSub-district,Pingshan District,ShenzhenCity,Guangdong,China Applicant’sname...............................:ShenzhenBravElectronicTechnologiesCo.,Ltd Address ................................................. : 4-5/F,Building11,TongfuyuIndustrialPark,Lezhujiao,Huangmabu Community,Hangchengstreet,Bao'anDistrict,Shenzhen,China Testspecification..............................: Standard ................................................ :FCCPart15.247 TRFOriginator......................................:ShenzhenGlobalTestServiceCo.,Ltd. MasterTRF...........................................:Dated2014-12 ShenzhenGlobalTestServiceCo.,Ltd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongastheShenzhen GlobalTestServiceCo.,Ltd.isacknowledgedascopyrightownerandsourceofthematerial.Shenzhen GlobalTestServiceCo.,Ltd.takesnoresponsibilityforandwillnotassumeliabilityfordamagesresultingfrom thereader'sinterpretationofthereproducedmaterialduetoitsplacementandcontext. Testitemdescription........................:ElectronicBloodPressureMonitor TradeMark............................................:N/A Manufacturer.........................................:ShenzhenBravElectronicTechnologiesCo.,Ltd Model/Typereference ......................... :BP-202 ListedModels ...................................... :N/A ModulationType .................................. :GFSK OperationFrequency..........................:From2402MHzto2480MHz HardwareVersion...............................:N/A SoftwareVersion..................................:N/A Rating ..................................................... :DC3.7VFrombatteryandDC5.0VFromadapter Result ..................................................... :PASS ReportNo.:GTS20260728001-3-01Page 2 of 35 TESTREPORT TestReportNo.: GTS20260728001-3-01 Sep.10,2026 ______________________________________________________________________________________________ Dateofissue EquipmentunderTest:ElectronicBloodPressureMonitor Model/Type : BP-202 Listedmodel : N/A Applicant : ShenzhenBravElectronicTechnologiesCo.,Ltd Address: 4-5/F,Building11,TongfuyuIndustrialPark,Lezhujiao,Huangmabu Community,Hangchengstreet,Bao'anDistrict,Shenzhen,China Manufacturer : ShenzhenBravElectronicTechnologiesCo.,Ltd Address: 4-5/F,Building11,TongfuyuIndustrialPark,Lezhujiao,Huangmabu Community,Hangchengstreet,Bao'anDistrict,Shenzhen,China TestResult:PASS Thetestreportmerelycorrespondstothet…
Text truncated - open the document above for the full version.
3722 Illinois Avenue, Saint Charles, · Illinois, 60174 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 2.90 mW |

Electronic Blood Pressure Monitor
Equipment Class
DTS - Digital Transmission System