FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Nokeval/
  3. 2A3B4KOMBI1

2A3B4KOMBI1Wireless air quality transmitter. Can measure temperature, humidity, CO2, VOC, particles and differential pressure. Uses LoRA WAN US915 radio

Nokeval
Wireless air quality transmitter. Can measure temperature, humidity, CO2, VOC, particles and differential pressure. Uses LoRA WAN US915 radio - FCC ID 2A3B4KOMBI1 - Nokeval
Click to zoom

Application Details

Equipment Class
JAD - Part 15 Class A Digital Device
Date of Grant
Jul 04, 2022
Application Purpose
Original Equipment
Date of Application
Jul 04, 2022
Equipment Note
Wireless air quality transmitter. Can measure temperature, humidity, CO2, VOC, particles and differential pressure. Uses LoRA WAN US915 radio
Company
Nokeval
Country
Finland

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗
↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ID12118 V25 24.3.2022 Firmware 1.0-1.0 eGate-Kombi-LWUS-RHT-CO2-TVOC-Dust40-DP eGate-Kombi-LWUS-RHT-Dust40 eGate-Kombi-LWUS-RHT-Dust13 eGate-Kombi-LWUS-RHT-DP eGate-Kombi-LWUS-RHT eGate-Kombi-LWUS-RHT-IP42 Manual 2 Contents Introduction .....................................................................................................................................................2 Pictures of variants ..........................................................................................................................................3 Installation .......................................................................................................................................................5 Operation .........................................................................................................................................................7 LoRaWAN settings ............................................................................................................................................9 Uplink payload structure............................................................................................................................... 10 Maintenance ................................................................................................................................................. 13 Specifications ................................................................................................................................................ 14 FCC labels ...................................................................................................................................................... 19 Warnings ....................................................................................................................................................... 20 Manufacturer ................................................................................................................................................ 20 Declaration of conformity ................................................................................. Error! Bookmark not defined. Introduction The Kombi-LWUS is an economical multi-sensor indoor air quality (IAQ) transmitter series. Depending on the variant, Kombi-LWUS can measure temperature, humidity, total volatile organic compound (TVOC) concentration, differential pressure, carbon dioxide (CO2) concentration, and particulate matter (PM). Kombi-LWUS uses LoRaWAN for communication with the cloud. Before using the 915 MHz radio, make sure it is legal in your country. 3 Pictures of variants -RHT-IP42 -RHT-Dust40 -RHT-Dust13 -RHT-DP -RHT 4 5 Installation Mounting Select the installation place so that the air can flow freely on all sides of the transmitter, representing the air that is to be measured. Avoid heat sources and direct sunlight. Place the device to the measuring location with one of the following ways: • Place the Kombi-LWUS on any surface with the bottom facing down. • Mount the wall holder with two universal countersunk screws (ST 2.5 or ST 3.0). Use applicable length depending wall material. In the correct orientation, the wall holder has its hooks pointing upwards. Attach the Kombi-LWUS to the holder. 6 Power supplies The Kombi-LWUS indicates the powerup by blinking the led next to the micro USB socket. -RHT-DP, -RHT, -RHT-IP42 variants These variants are powered with 3 pcs LR6 batteries (AA 1.5 V alkaline). High quality batteries should be used, for example Energizer EN91. The device is supplied with batteries already installed, so it is ready to be used. The Kombi-LWUS can alternatively be powered with an external supply. When an external power supply is used, the batteries can be omitted or used as a backup supply. Use the micro USB socket to connect an external supply into the device. -Dust13, -Dust40, -RHT-CO2-TVOC-Dust40-DP These variants with PM sensor must be powered with an external supply. Use the micro USB socket to connect an external supply into the device. Settings The Kombi-LWUS works with its default settings and no parameter configuration is normally required. However, if it is necessary to change the settings of the device, it can be done with Nokeval’s MekuWin software (available for free at www.nokeval.com). Following procedure should be followed in order to get access to the settings: • Connect a micro-USB cable to the connector and the other end of the cable to a computer. • If Windows requests for a driver, download it at www.nokeval.com > Support, unzip it to a temporary folder, and show that directory as the location for the driver. If there are problems during the installation, try pushing the button every 5-15 seconds or keeping it pressed so that the Kombi-LWUS will not shut down its USB port. • Launch the MekuWin program. • In MekuWin, choose the right COM-port form the Ports-menu. If the port is not visible, try pushing the button on the Kombi-LWUS to wake up the port. • From the Port settings -menu, choose Protocol = ModbusRTU, Address = 1. • Click Direct. • A new window will open for the settings. The configuration menu includes the following settings: • Protection o Describes password protection status “None”, “Locked”, “Unlocked”. • Password input/setup o Unlock protection or change password. See “Protecting the settings” section below for details. • Period o Time between measurements with options from ranging 5 minutes to 6 hours. Default is 15 min. • LoRaWAN o If the Kombi-LWUS is used with the Nokeval cloud platform, the default settings are ok. If you wish to manually set the LoRaWAN credentials and/or integrate it with your cloud platform, see “LoRaWAN settings” and “Uplink payload structure” chapters. 7 Protecting the settings To protect the settings from being easily adjusted, the configuration menu provides a password box. The password can be formed by using up to 16 characters. From the next MekuWin session, the settings cannot be adjusted without knowing…

Text truncated - open the document above for the full version.

ID Label/Location Info

eGate-Kombi-LWUS label location Nokeval Oy / Juha Hämäläinen 2022-03-21 In the models • eGate-Kombi-LWUS-RHT-CO2-TVOC-Dust40-DP • eGate-Kombi-LWUS-RHT-Dust40 • eGate-Kombi-LWUS-RHT-Dust13 • eGate-Kombi-LWUS-RHT-DP • eGate-Kombi-LWUS-RHT the label is located at the bottom of the device. When the device is installed in its wall holder, the label is not visible as it is between the device and the wall holder. When the device is detached from the wall holder, the label is visible. The device can be detached without any tools, just by pushing it slightly upwards to release the hooks. Label at the bottom Wall mount Hooks Mounting screw holes In the model eGate-Kombi-LWUS-RHT-IP42, the label is installed in the visible side of the outer enclosure.

Test Report

Reference number: HELEM2108000327-1 Page 1 of 13 These test results are valid for the tested unit only. This report shall not be reproduced, except in full, without a written permission of SGS Fimko. Test Report Electromagnetic Compatibility (EMC) HELEM2108000327-1 TESTS ACCORDING TO FCC PART 15 B AND ISED CANADA REQUIREMENTS Equipment Under Test: Indoor air quality transmitter Model: eGate-Kombi-LWUS-RHT-CO2-TVOC-Dust40-DP Type: - Manufacturer: Nokeval Oy Rounionkatu 107 FI-37150, Nokia Finland Customer: Nokeval Oy Rounionkatu 107 FI-37150, Nokia Finland FCC Rule Part: FCC CFR 47 Part 15 Subpart B, Class B IC Rule Part: ICES-003 Issue 7, Class B Date: 10 June 2022 Date: 10 June 2022 Issued by: Henri Mäki Checked by: Rauno Repo Testing Engineer Senior EMC Specialist Reference number: HELEM2108000327-1 Page 2 of 13 Table of Contents TABLE OF CONTENTS TABLE OF CONTENTS ................................................................................................................................. 2 GENERAL REMARKS ................................................................................................................................... 3 Disclaimer ................................................................................................................................................. 3 RELEASE HISTORY...................................................................................................................................... 4 PRODUCT DESCRIPTION ............................................................................................................................ 5 Equipment Under Test (EUT) .................................................................................................................... 5 General description ................................................................................................................................... 5 Samples and modifications........................................................................................................................ 6 Ports and cables ....................................................................................................................................... 6 Peripherals ............................................................................................................................................... 6 TEST CONDITION ......................................................................................................................................... 7 EUT Test Conditions During EMC-Testing ................................................................................................. 7 Operation modes ...................................................................................................................................... 7 Emission Measurement Uncertainty .......................................................................................................... 7 SUMMARY OF TESTING .............................................................................................................................. 8 EMISSION TESTS ......................................................................................................................................... 9 Conducted Emissions In The Frequency Range 150 kHz – 30 MHz........................................................... 9 Radiated Emissions In The Frequency Range 30 – 1000 MHz................................................................... 11 TEST EQUIPMENT ....................................................................................................................................... 13 Conducted Emissions ............................................................................................................................... 13 Radiated Emissions .................................................................................................................................. 13 Reference number: HELEM2108000327-1 Page 3 of 13 Disclaimer GENERAL REMARKS Disclaimer This document is issued by the Company subject to its General Conditions of Service printed overleaf, avail- able on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for electronic for- mat documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms- and-Conditions/Terms-e-Document.aspx Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole respon- sibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only. Reference number: HELEM2108000327-1 Page 4 of 13 Release History RELEASE HISTORY Version Changes Issued 1.0 Initial release 1 March 2022 1.1 Radiated Emissions test description updated on page 11. 10 June 2022 Reference number: HELEM2108000327-1 Page 5 of 13 Product Description PRODUCT DESCRIPTION Equipment Under Test (EUT) EUT information General Product Description Indoor air quality transmitter Trademark eGate Model eGate-Kombi-LWUS-RHT-CO2-TVOC-Dust40-DP Type - Serial number N110553 Power input port type DC (USB Micro-B) Rated voltage 5 ± 0.5 V Rated current 1 A max Rated frequency - Rated power - EUT Highest operation freq. 32 MHz Hardware …

Text truncated - open the document above for the full version.

Test Setup Photos

TEST SETUP PHOTOGRAPHS Page 1 of 1 Project number: HELEM2108000327-1 SGS Fimko Ltd. Takomotie 8, FI-00380 Helsinki Finland t +358 9 6963 361 f +358 9 692 5474 www.sgs.fi Member of SGS Group (Société Générale de Surveillance) Photograph 1. Conducted emissions 150 kHz – 30 MHz Photograph 2. Radiated emissions 30 – 1000 MHz

Contact Information

Applicant

Lari Maasalo(CTO)
[email protected]358405868584Fax: 35833422066

Technical Contact

Nokeval OyJuha Hamalainen
[email protected]35846137115

Rounionkatu 107 · Nokia · Finland

Non-Technical Contact

Nokeval OyJuha Hamalainen
[email protected]35846137115

Test Firm

SGS Fimko OyJanne Nyman
[email protected]+358 9 696 361Fax: +358-9-696-5474

Technical Specifications

#Rule PartsFrequency RangePower Output
115B--
Confidentiality
Long Term