
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
0201 0403 0605 0807 1009 1211 1413 1615
U.S. Agent Designation for Service of Process (Applicant and U.S. Agent are Separate Parties) ATTENTION: FCC Certification โ Section 2.911(d)(7) Information Designated U.S. Agent Company Name: Baihetian Innovative Solutions Street Address: 6837 Chase Rd City/Province/Zip: Dearborn, MI 48126 FRN: 0033401605 Contact Name: Kenneth Young Telephone No: 313-395-3113 Email: [email protected] Signature: Signed by (Printed Name/Title): This letter is to confirm that we (โthe Designated U.S. Agent) have accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by section 47 CFR 2.911(d)(7) on behalf of the Applicant noted below. The Applicant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. Applicant Company name: Shenzhen Libro Technology Co., Ltd. FRN: 0031489180 Grantee Code: 2A3DE FCC ID: 2A3DE- PLWF116S Contact Name: Yongle Luo Street Address: Room 501, West Tower, Twin Towers, Galaxy World,No. 8 Yaxing Road, Nankeng Community, Bantian Street,Long-gang District, Shenzhen, China Telephone No: 15899788551 Email: [email protected] Signature: Date: 2026-03-20 Signed by (Printed Name/Title): Yongle Luo Apr 2026 Kenneth Mathew Young/Manager
2026-03-20 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for FCC ID: 2A3DE-PLWF116S [Shenzhen Libro Technology Co., Ltd.] certifies that the equipment for which authorization is sought is not โcoveredโ equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, the equipment does not utilize cyber-security or anti-virus software from Kaspersky Lab, Inc, or any of its successors and assignees, which is also on the โcovered listโ. Sincerely, Signature: Name: Yongle Luo 2026-03-20 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for FCC ID: 2A3DE- PLWF116S Shenzhen Libro Technology Co., Ltd. certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing โcoveredโ equipment. Sincerely, Signature: Name: Yongle Luo
2026-03-20 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (DOCKSTREAM 2 Smart Cordless Fountain / PLWF116S, 6236116/ FCC ID: 2A3DE-PLWF116S) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the (Block Diagrams, Schematics, Operational Descriptions, FCC SW SECURITY DESCRIPTION) required to be submitted with this application be permanently withheld from public review. The above documents are company proprietary information that could never get into the possession of your competition. Please contact me if there is any information you may need. Sincerely, Signature: Name: Yongle Luo Applicant: Shenzhen Libro Technology Co., Ltd. Address: Room 501, West Tower, Twin Towers, Galaxy World,No. 8 Yaxing Road, Nankeng Community, Bantian Street,Long-gang District, Shenzhen, China
2026-03-20 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize (Eurofins Electrical Testing Service (Shenzhen) Co., Ltd.) to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Signature: Name: Yongle Luo Applicant: Shenzhen Libro Technology Co., Ltd. Address: Room 501, West Tower, Twin Towers, Galaxy World,No. 8 Yaxing Road, Nankeng Community, Bantian Street,Long-gang District, Shenzhen, China TEL: 15899788551
Declaration on model difference We, Shenzhen Libro Technology Co., Ltd.the undersigned hereby declare that the device's schematics, PCB layout and all other electrical aspects of the device are identical. The only differences are the model no. and distribution chains for trading purpose. Product Name: DOCKSTREAM 2 Smart Fountain Models: PLWF106S, 6236106 FCC ID:2A3DE-PLWF106S Name / Title: Yongle Luo Company: Shenzhen Libro Technology Co., Ltd.
10G Radar 10G Radar 10G Radar Module 10G Radar ANT Alternative battery (Model: M1S2P-18650-R172, 3.6Vdc 5200mAh 18.72Wh) (factory: HENGDIAN GROUP DMEGC MAGNETICS Co.,Ltd.) BT WIFI ANT Alternative battery (Model: M1S2P-18650-R172, 3.6Vdc 5200mAh 18.72Wh) (factory: JIANGSU TENPOWER LITHIUM Co., Ltd.)
Radiofrequency radiation exposure evaluation: mobile devices RESULT : Pass Test Specification Test item : DOCKSTREAM 2 Smart Cordless Fountain Identification / Type No. : PLWF116S, 6236116 FCC ID : 2A3DE-PLWF116S Test standard : CFR47 FCC Part 2: Section 2.1091 CFR47 FCC Part 1: Section 1.1310 FCC KDB Publication 447498 D04 โข FCC requirements FCC requirement: Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess limit for maximum permissible exposure. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as a mobile device whereby a distance of 20cm normally can be maintained between the user and the device. MPE Calculation Method according to KDB 447498 D04 a) EUT RF Exposure Evaluation operations, Worst Case mode For 10.525GHz SRD E.I.R.P = 96.78 โ 95.2 = 1.58dBm ERP = 1.58 โ 2.15 = -0.57dBm = 0.877mW The 10.525GHz SRD has two module to TX together, so 0.877mW *2=1.754mW Test Mode Conducted Power (dBm) Conducted Power (mW) ERP (dBm) ERP (mW) Total Minimum Separation Distances (cm) Limit (mW) BLE 6.1 4.074 6.22 4.188 106.947 20 3060 2.4GHz band Wi-Fi 17.92 61.944 18.04 63.680 5GHz band Wi-Fi 14.95 31.261 15.72 37.325 10.525GHz SRD --- --- 2.44 1.754
NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 1 of 32 REPORT No.๏ผSZ25120440W01 TEST REPORT APPLICANT :Shenzhen Libro Technology Co., Ltd. PRODUCT NAME : DOCKSTREAM 2 Smart Cordless Fountain MODEL NAME :PLWF116S, 6236116 BRAND NAME :N/A FCC ID : 2A3DE-PLWF116S STANDARD(S) : 47 CFR Part 15 Subpart C RECEIPT DATE : 2025-12-31 TEST DATE :2026-01-14 ISSUE DATE :2026-04-09 Edited by: Zeng Xiaoying (Rapporteur) Approved by: Shen Junsheng (Supervisor) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 2 of 32 REPORT No.๏ผSZ25120440W01 DIRECTORY 1. Technical Information ๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊ 3 1.1. Applicant and Manufacturer Information ๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊ 3 1.2. Equipment Under Test (EUT) Description ๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊ 3 1.3. Test Standards and Results ๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊ 4 1.4. Environmental Conditions ๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊ 4 2. 47 CFR Part 15C Requirements ๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊ 5 2.1. Field Strength of Fundamental ๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊ 5 2.2. Radiated Emission and Field Strength of Harmonic ๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊ 7 2.3. Restricted Bands ๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊ 22 Annex A Test Uncertainty ๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊ 28 Annex B Testing Laboratory Information ๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊ 29 Notes ๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊ 32 Change History Version Date Reason for change 1.0 2026-04-09 First edition MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 3 of 32 REPORT No.๏ผSZ25120440W01 1. Technical Information Note: Provide by applicant. 1.1. Applicant and Manufacturer Information Applicant: Shenzhen Libro Technology Co., Ltd. Applicant Address: Room 501, West Tower, Twin Towers, Galaxy World,No. 8 Yaxing Road, Nankeng Community, Bantian Street,Longgang District, Shenzhen, China Manufacturer: N/A Manufacturer Address: N/A 1.2. Equipment Under Test (EUT) Description Product Name: DOCKSTREAM 2 Smart Cordless Fountain Sample No.: 1# Hardware Version: V1.1 Software Version: 0.3.29 Operating Frequency: 10.50GHz-10.55GHz Antenna Type: Internal Antenna Note 1: The EUT description presented in the report are provided by applicant and/or manufacturer, and the test laboratory is not responsible for the accuracy of the information. For a more detailed description, please refer to Specification or Userโs Manual supplied by the applicant and/or manufacturer. Note 2: According to the certificate holder, they declared that the models PLWF116S, 6236116 only different in model name, all RF parameters remain the same. The main measuring model is PLWF116S, only the results for PLWF116S were recorded in this report. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 4 of 32 REPORT No.๏ผSZ25120440W01 1.3. Test Standards and Results The objective of the report is to perform testing according to 47 CFR Part 15 Subpart C for the EUT FCC ID Certification: No. Identity Document Title 1 47 CFR Part 15 Radio Frequency Devices Test detailed items/section required by FCC rules and results are as below: No. Section Description Test Date Test Engineer Result Remark 1 15.245(b) Field Strength of Fundamental Jan. 14, 2026Tian Xin PASS / 2 15.245(b) Radiated Emission and Field Strength of Harmonic Jan. 14, 2026Tian Xin PASS / 3 15.245(b)(3) 15.205 15.209 Restricted Bands Jan. 14, 2026Tian Xin PASS / Note 1: The tests were performed according to the method of measurements prescribed in ANSI C63.10-2020. Note 2: Any additions, deviation, or exclusions from the method shall be noted in the โRemarkโ. 1.4. Environmental Conditions During the measurement, the environmental conditions were within the listed ranges: Temperature (ยฐC): 15-35 Relative Humidity (%): 30-60 Atmospheric Pressure (kPa): 86-106 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 5 of 32 REPORT No.๏ผSZ25120440W01 2. 47 CFR Part 15C Requirements 2.1. Field Strength of Fundamental 2.1.1. Requirement According to FCC section 15.245(b), the field strength of fundamental andโฆ
Text truncated - open the document above for the full version.
AntennaSpecifications DesignSpecifications Typical AntennaType* Patch WorkingFrequency 10GHz AntennaGain4.76dBi AntennaEfficiency โฅ30% VSWR โค2 Impedance 50ohm OverallDimensions* 6.93mm*6.93mm Manufacturer'scompany name ๆทฑๅณๅธ็งไธไฝณ็ตๅญๆ้ๅ ฌๅธ Shenzhenkeshijiaelectronicsco.,ltd ManufacturerAddress ๆทฑๅณๅธๅฎๅฎๅบๆฒไบ่ก้ไธญ็ๅทฅไธๅญDๆ ไธๆฅผ Firstfloor,BuildingD,ZhongxiIndustrialPark, ShajingStreet,Bao'anDistrict,Shenzhen โซSchematic โซ3DAntennaGain โซ2DAntenna Gain
Test Report No.: EFGX25110484-IE-02-E04 Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. Room 20 of 2/F., 1/F., Building 2, Spring Block & Room 102, Building 8, Autumn Block, Meishenghuigu Innovation Park, No.83, Dabao Road, Baoโan District, Shenzhen, Guangdong, China Telephone: +86-755-82911867, Fax : +86-755-82910749 Page 1 of 16 EUROFINS ELECTRICAL TESTING SERVICE (SHENZHEN) CO., LTD. RADIO TEST - REPORT FCC Compliance Test Report for Product name: DOCKSTREAM 2 Smart Cordless Fountain Model name: PLWF116S, 6236116 FCC ID: 2A3DE-PLWF116S Test Report Number: FGX25110484-IE-02-E04 Test Report No.: EFGX25110484-IE-02-E04 Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. Room 20 of 2/F., 1/F., Building 2, Spring Block & Room 102, Building 8, Autumn Block, Meishenghuigu Innovation Park, No.83, Dabao Road, Baoโan District, Shenzhen, Guangdong, China Telephone: +86-755-82911867, Fax : +86-755-82910749 Page 2 of 16 1 General Information 3 1.1 Notes 3 1.2 Testing laboratory 4 1.3 Details of applicant 4 1.4 Details of manufacturer 4 1.5 Application details 5 1.6 Test item 5 1.7 Test standards 5 2 Technical test 6 2.1 Summary of test results 6 2.2 Test environment 6 2.3 Measurement uncertainty 6 2.4 Test mode 7 2.5 Test equipment utilized 7 2.6 Auxiliary Equipment Used during Test: 7 2.7 Test software information: 8 2.8 Test setup 9 2.9 Test results 11 3 Technical requirement and result 12 3.1 Conducted emission AC power port 12 3.2 20 dB bandwidth 15 Test Report No.: EFGX25110484-IE-02-E04 Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. Room 20 of 2/F., 1/F., Building 2, Spring Block & Room 102, Building 8, Autumn Block, Meishenghuigu Innovation Park, No.83, Dabao Road, Baoโan District, Shenzhen, Guangdong, China Telephone: +86-755-82911867, Fax : +86-755-82910749 Page 3 of 16 1 General Information 1.1 Notes The results of this test report relate exclusively to the item tested as specified in chapter โDescription of test itemโ and are not transferable to any other test items. Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. is not responsible for any generalisations and conclusions drawn from this report. Any modification of the test item can lead to invalidity of test results and this test report may therefore be not applicable to the modified test item. The test report may only be reproduced or published in full. Reproducing or publishing extracts of the report requires the prior written approval of the Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. This document is subject to the General Terms and Conditions and the Testing and Certification System of Eurofins Electrical Testing Service (Shenzhen) Co., Ltd., available on request or accessible at www.eurofins.com. Operator: 2026-03-02 Bruce Zheng / Project Engineer Date Eurofins-Lab. Name / Title Signature Technical responsibility for area of testing: 2026-03-02 Albert Xu / Lab Manager Date Eurofins-Lab. Name / Title Signature Test Report No.: EFGX25110484-IE-02-E04 Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. Room 20 of 2/F., 1/F., Building 2, Spring Block & Room 102, Building 8, Autumn Block, Meishenghuigu Innovation Park, No.83, Dabao Road, Baoโan District, Shenzhen, Guangdong, China Telephone: +86-755-82911867, Fax : +86-755-82910749 Page 4 of 16 1.2 Testing laboratory Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. Room 20 of 2/F., 1/F., Building 2, Spring Block & Room 102, Building 8, Autumn Block, Meishenghuigu Innovation Park, No.83, Dabao Road, Baoโan District, Shenzhen, Guangdong, China Telephone : +86-755-82911867 Fax : +86-755-82910749 The Laboratory has passed the Accreditation by the American Association for Laboratory Accrediation (A2LA). The Accreditation number is 5376.01 The Laboratory has been listed by industry Canada to perform electromagnetic emission measurements, The CAB identifier is CN0088 1.3 Details of applicant Name : Shenzhen Libro Technology Co., Ltd. Address : Room 501, West Tower, Twin Towers, Galaxy World,No. 8 Yaxing Road, Nankeng Community, Bantian Street,Long- gang District, Shenzhen, China Telephone : ./. Fax : ./. 1.4 Details of manufacturer Name : Shenzhen Libro Technology Co., Ltd. Address : Room 501, West Tower, Twin Towers, Galaxy World,No. 8 Yaxing Road, Nankeng Community, Bantian Street,Long- gang District, Shenzhen, China Telephone : ./. Fax : ./. Test Report No.: EFGX25110484-IE-02-E04 Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. Room 20 of 2/F., 1/F., Building 2, Spring Block & Room 102, Building 8, Autumn Block, Meishenghuigu Innovation Park, No.83, Dabao Road, Baoโan District, Shenzhen, Guangdong, China Telephone: +86-755-82911867, Fax : +86-755-82910749 Page 5 of 16 1.5 Application details Date of receipt of application : 2025-12-09 Date of receipt of test item : 2025-12-09 Date of test : 2025-12-09 to 2026-03-02 Date of issue : 2026-03-02 1.6 Test item Product type : DOCKSTREAM 2 Smart Cordless Fountain Test Model : PLWF116, 6236116 Sample ID : 251209-27-002 Brand : PETLIBRO Serial number : ./. Ratings : AC Adapter (Input: 100-240V~ 50/60Hz, 0.2A; Output: DC 5.0V 1.0A, 5.0W); The battery: DC 3.6V Test voltage : DC 3.6V RadioTechnical data Frequency range : 10500MHz โ 10550MHz Radio Tech. : 10G SRD Frequency channel : CH1: 5843MHz Modulation : FMCW Antenna type : Internal antenna Additional information : 1. According to the declaration from the applicant, all models are identical except for the model name. Therefore full tests were performed on model PLWF116. 1.7 Test standards Test Standards FCC Part 15 Subpart C PART 15 - RADIO FREQUENCY DEVICES Subpart C - Intentional Radiators Test Method 1: ANSI C63.4-2014, American National Standard for Methods of Measurement of Radio-Noise Emis- sions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz. 2: ANSI C63.10-2020, American National Standard for Testing Unlicensed Wireless Devices. Test Report No.: EFGX25110484-IE-02-E04 Eurofins Electricโฆ
Text truncated - open the document above for the full version.
9KHz โ 30MHz 30MHz โ 1000MHz 1GHz -18GHz 18GHz -40GHz 40GHz -60GHz
6837 Chase Rd ยท Dearborn, MI 48126 ยท United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.245 | 10.53 GHz - 10.53 GHz | - |
Smart Feeder (Granary 2 Vision, Granary 2 Vision Duo, Granary 2 X)
Equipment Class
DTS - Digital Transmission SystemSmart Feeder (Granary 2)
Equipment Class
NII - Unlicensed National Information Infrastructure TX
DOCKSTREAM 2 Smart Fountain
Equipment Class
NII - Unlicensed National Information Infrastructure TXAir WiFi Feeder
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Air WiFi Feeder
Equipment Class
DTS - Digital Transmission System