Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
For Quickstart Video Guide, FAQs a nd Warranty Registration, scan the code to the right or visit BioLite.Help/BaseCharge1 500 BioLite BaseCharge 1 500 Instruct ional Manual 2 BEFORE YOU GET STARTED ADDITIONAL TIPS TO GET THE MOST FROM YOUR BASECHARGE: 1. Read the Instruction Manual or visit BioLite.Help/BaseCharge1500 to watch an overview video. 2. Regularly inspect ports for dust, dirt or moisture. 3. months in case of a warranty issue. Register your BaseCharge to activate your warranty. Scan code or visit BioLite.Help/BaseCharge1500 Plug in your BaseCharge and allow unit to charge to 100%. 3 See Warranty Terms & Conditions on Page 7 TABLE OF CONTENTS PRODUCT OVERVIEW Anatomy Tech Specs USING YOUR BASECHARGE Port Overview Port Activation Wireless Charging Easy-Read LCD Display Message Center Error Codes Resetting BaseCharge CHARGING THE BASECHARGE Charge Up Overview Solar Charging MAINTENANCE & CARE Storage & Operational Temperatures Safety Warnings FAQ Frequently Asked Questions INTERNATIONAL Français (FR) Español (ES) Deutsch (DE) Svenska (SV) Norsk (NO) Suomi (FI) (ZH-CN) 한국어 (KO) Italiano (IT) Dutch (NL) 5 6 20-21 21-22 22-24 24-25 25-26 26-28 28-29 29-31 31-33 33-34 34-35 8 9 10 11 12 13 14 15 16 17 18 4 ANATOMY INTRODUCTION The BaseCharge 1500 power station* is a li-ion (NMC) batt ery storage device. For power output BaseCharge 1500 includes a 110 V AC pure sine wave inverter for sensitive devices, as well as a number of DC ports including a regulated 12 V cigar ett e lighter , USB-A and USB-C ports, as well as wireless charging on the top deck of the unit. These ports can be used to power most indoor 110V appliances and small electrical devices. For charging inputs they include the HPP 110 V AC power supply unit and solar input capabilities. The BioLite SolarPanel 100 is recommended. NOTE: The “1500” relates to the tota l watt-hour capacity of the power station, which is 1520.64 watt-hours. 5 1. Easy-Read LCD Display 4. Power Inputs/Outputs FIGURE 5 3. Carry Handles + Ventilation Grills 5. AC Charger For Power In 2. Wireless Charging Pad 6 TECHNICAL SPECIFICATIONS BATTERY 1520.64 Wh (21.6 V, 70.4 Ah), Li-Ion (NMC) INPUTS Wall/ Solar Input (HPP), 400 W (10-30 V DC, 20 A max) USB-C PD, 100 W CHARGE MANAGEMENT Maximum Power Point Tracking (MPPT) AC OUTPUTS US: (3x) 110 V, Pure Sine Wave, 1200 W UK/EU/NZ/AUS: (3x) 230 V, Pure Sine Wave, 1200 W 2,400 W Surge Plug types • United Sta tes (Type A) • United Kingdom (Type G) • Europe (Type C) • New Zealand & Australia (Type I) WIRELESS OUTPUT 10 W Wireless Charger DC OUTPUTS (1x) 12 V Carport Output: 12 0 W (2x) 12 V DC Barrel Ports: 120 W. 5.5 mm OD / 2.1 mm ID CYCLE CAPACITY >80% capacity aft er 500 full charge cycles USB OUTPUTS (2x) USB-A: 5 V / 2.4 A (2x) USB-C: 5 V / 3.0 A (1x) USB-C PD: 5 V, 9 V, 12 V, 20 V / 5 A (100 W) 7 TECHNICAL SPECIFICATIONS CHARGE TIME TO 80% Included AC Wall Adapter: 13.5 hours Included AC Wall Adapter + USB-C PD: 8 hours Peak Input 4x SolarPanel 100: 4 hours SHELF LIFE Recharge every 6 months to prolong life 36 months storage capability DIMENSIONS 14.4 x 12.2 x 8.2 in 367 x 310 x 209 mm WEIGHT 26.5 lbs 12.1 kg IN THE BOX BaseCharge 1500 Power Sta tion Instruction Manual 12 0 W AC Wall Adapter WARRANTY FOR CUSTOMERS IN THE UNITED STATES, CANADA, UK AND EU: B aseCharge has a 2 year limited warranty. Should this product not function properly under normal use within 2 years of purchase, contact your original point of purchase to complete the required troubleshooting process. If you purchased your product through Amazon or BioLiteEnergy.com, contact BioLite (bioliteenergy. com/contact) to complete the required troubleshooting process. If this process directed to return the unit to the point of purchase for a full replacement at no charge. This warranty does not cover any damage or malf unction arising from misuse, improper maintenance, negligence, normal wear and tear , or accident. FOR ALL OTHER CUSTOMERS: Please contact your local supplier to obtain information regar ding the applicable warranty for BioLite products in your BioLiteEnergy.com/International. 8 1. Regulated 12 V DC Port (Car Cigarett e Lighter) 5. HPP Input 6. 12 V 5.1 mm DC Ports 8. Port Activation Buttons (Press to activate or turn off port) Europe Type C, 230 V United Kingdom Type G, 230 V Australia Type I, 230 V 7. (3) 110 V AC Outlets, Sine Wave (Ports vary by region) 3. (2) USB-C (Output Only) 2. (2) USB-A 4. USB-C PD In/Out (100 W Max) FIGURE 8 PORT OVERVIEW AC AC 9 PORT INDICATOR LIGHTS BEHAVIOR FIG 10.1 FIG 10.2 FIG 10.3 FIG 9 POWERING A DEVICE 1. Plug in device to the corresponding port (FIG 10.1). 2. Press port activation button. The Port Indicator Light will turn to green (FIG 10.2) indicating “ON”. 3. The Easy-Read LCD Display will indicate the output wattage, and runtime until the BaseCharge is empty (FIG 10.3). 4. IMPORTANT: Press Port Activation Button to turn off port when not in use. This will help conserve power . PORT ACTIVATION (No Light) Port Is OFF (Solid Green) Port Is ON OUTPUT (Pulsing Green) Port Is ON INPUT (Flashing Green) Low Power Mode Batt ery is less than 3%. Connect to a power source. (Red) ERROR See Message Center for details DISPLAY 10 WIRELESS CHARGING The BaseCharge includes wireless charging for compatible devices. Put your wireless charging-compatible device on the top of the BaseCharge, covering the wireless charging icon. Note that only one device can charge at a time. If the screen is not on, press any Port Activation Button to wake up the the Easy-Read LCD screen to ensure your device is charging. The wireless charging will stop when the device is 100% charged or removed fr om the top deck. Wireless Charging Icon FIG 13 EASY-READ LCD DISPLAY SEE/RESET WH USED DISPLAY 1. Hours To Empty/Hours To Full: If input watts exceed output watts, the user interface will display “Hours To Full.” Conversely, if output watts exceed input watts, user interface will display “Hours To Empty.” 2. State Of Charge: Displays…
Text truncated - open the document above for the full version.
BioLite Inc • 65 Jay Street, 3 rd Floor, Brooklyn, New York, 11201 • BioLiteEnergy.com 20.07.2021 Federal Communications Commission 445 12 th Street SW Washington, DC 20554 Subject: Limited Agency Agreement BioLite Inc. FCC ID: 2A3GZBGB To Whom It May Concern: We, BioLite Inc., hereby authorized Intertek Testing Services Shenzhen Ltd. Guangzhou Branch to act as our Agent for the purpose of preparing application for FCC ID number 2A3GZBGB under all applicable parts of the FCC rules and regulations. The effective date of this limited agency agreement is 20/07/2022. The Limited Agency Agreement expires on 20/11/2022, unless sooner terminated or extended by written notice to Intertek Testing Services Shenzhen Ltd. Guangzhou Branch and the Federal Communications Commission. This is to advise that we are in full compliance with the Anti-Drug Abuse Act. The applicant is not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 U.S.C. 862, and no party to the application is subject to a denial of federal benefits pursuant to that section. If you have any questions or comments, please do not hesitate to contact me. Sincerely, By: Simon Tremeer Title: Associate Director of Manufacturing On behalf of: BioLite Inc
BioLite Inc • 65 Jay Street, 3 rd Floor, Brooklyn, New York, 11201 • BioLiteEnergy.com 20.07.2021 Attention: Application Examiner RE: Request for Confidentiality Applicant: BioLite Inc. FCC ID: 2A3GZBGB To Whom It May Concern: Permanent Confidentiality [Complete this section if permanent confidentiality is requested] Request is hereby submitted by BioLite Inc. to withhold permanently from public review certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR 0.457(d) and 0.459 of the FCC Rules. In particular, the following sections of the application are to be kept permanently confidential: • Schematics • Detailed Block Diagrams • Detailed Operational/Functional Description Rationale for request for confidentiality: BioLite Inc.has invested considerable time and materials in research and development to produce the referenced product. [Permanent confidentiality: Disclosure of the permanently confidential portions of this application to competitors would not only give them significant competitive advantages in developing similar products, but would also disclose successful implementation of unpublished, leading edge technology developed by us.] If you have questions or need further information, please contact the undersigned. Sincerely, By: Simon Tremeer Title: Associate Director of Manufacturing On behalf of: BioLite Inc Tel: +44 7821278537
BioLite Inc • 65 Jay Street, 3 rd Floor, Brooklyn, New York, 11201 • BioLiteEnergy.com 19.07.2021 Cover Letter - Wireless Charger Approval FCC ID: 2A3GZBGB There’s a Wireless Charger (contain Wireless charging pad), which would like to have your authorization as Inductive wireless power transfer applications approval Applicant Name & Address : BioLite Inc. 65 Jay Street, 3 rd Floor, Brooklyn, New York, 11021, USA. Model No. : BGB0101 FCC ID : 2A3GZBGB KDB 680106 D01 Clause 5b) all (1) to (6) Requirements: Product Technical Specification Result 1) Power transfer frequency is less than 1 MHz 120-203KHz Complied 2) Output power from each primary coil is less than or equal to 15 watts 10Watts Complied 3) The system may consist of more than one source primary coils, charging one or more clients. If more than one primary coil is present, the coil pairs may be powered on at the same time. The device include one primary coil Complied 4) Client device is Placed directly in contact with the transmitter Client device is placed directly in contact with the transmitter Complied 5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion). Mobile device Complied BioLite Inc • 65 Jay Street, 3 rd Floor, Brooklyn, New York, 11201 • BioLiteEnergy.com 6) The aggregate H-Field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. Max H-Field Strength: 0.059A/m Complied Sincerely, By: Simon Tremeer Title: Associate Director of Manufacturing On behalf of: BioLite Inc Tel: +44 7821278537
119mm 59 .1mm 110V~60Hz, Rated power 1200W each port,2400W Surge, Total 1200W Pure Sine Wave each port, Total 30W Max 100W Max each port, Total 30W Max & DC5521(2X)each port, Total 120W Max 100W Max Total DC+USB-C PD Input 500W Max 0-40°C Total DC+AC Output 1200W Max 1520.64 MISE EN GARDE : Risque de décharge électrique. Ne pas enlever le couvercle.Aucune des pièces à l’intérieur ne peutêtre réparée par l’utilisateur. L’entretien courant doit être effectué par un personnel d’entretien qualifié. Risque de blessure aux personnes. Ne pas utiliser ce produit si le cordon d’alimentation ou les cables de batterie sont endommagés de quelque façon. Le dispositif n’est pas destiné à être utilisé dans un atelier de réparation commercial. Le dispositif est destiné à être utilisé à l’intérieur seulement. Ne pas l’utiliser à l’extérieur. AVERTISSEMENT: Ne pas surcharger la batterie interne.Consulter le manuel d’utilisation. Il ne faut pas fumer, allumer une allumette ou produire des étincelles à proximité du bloc d’alimentation.Charger la batterie uniquement dans un endroit bien aéré. CAUTION: Risk of Electric Shock. Do not remove cover. No user serviceable parts inside. Refer servicing to qualified service personnel. Risk of Injury to persons. Do not use this product if the power cord or the battery cables are damaged in any way. This device is not intended for use in a commercial repair facility. This device is intended to be used indoors only. Do not use outdoors. WARNING: A) Do not overcharge the internal battery. See Instruction Manual. B) Do not smoke, strike a match, or cause a spark in the vicinity of the power pack. C) Only charge the internal battery in a well ventilated area. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Date Code: 202206
BioLite Inc. TEST REPORT SCOPE OF WORK EMC TESTING–BGB0101 REPORT NUMBER 220329091GZU-002 ISSUE DATE [REVISED DATE] 19-August-2022 [--------------------] PAGES 10 DOCUMENT CONTROL NUMBER © 2017 INTERTEK TEST REPORT Room 02, & 101/E201/E301/ E401/E501/E601/E701/E801 of Room 01 1-8/F., No. 7-2. Caipin Road, Science City, GETDD, Guangzhou, Guangdong, China Telephone: +86 20 8213 9688 Facsimile: +86 20 3205 7538 www.intertek.com.cn This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Testing Services Shenzhen Ltd. Guangzhou Branch Room 02, & 101/E201/E301/E401/E501/E601/E701/E801 of Room 01 1-8/F., No. 7-2. Caipin Road, Science City, GETDD, Guangzhou, Guangdong, China Version: 21 August 2017 Page 2 of 10 Applicant Name & Address : BioLite Inc. 65 Jay Street 3rd Floor, Brooklyn, NY 11201 United States Manufacturing Site : Dongguan DBK Energy Technology Co., Ltd No. 252, Zhangmutou Section, Dongshen Rd., Zhangmutou Town, DONGGUAN CITY, Guangdong Province China Intertek Report No: FCC ID: 220329091GZU-002 2A3GZBGB Test standards 47 CFR PART 1, Subpart I, Section 1.1310 KDB 680106 D01 RF Exposure Wireless Charging App v03r01 Sample Description Product : BaseCharge 1500 Model No. : BGB0101 Electrical Rating : See page 5 Serial No. : Not Labeled Date Received : 29 March 2022 Date Test Conducted : 18 July 2022-25 July 2022 Prepared and Checked By Elena Lei Engineer Approved By: Dean Liu Project Engineer TEST REPORT Intertek Report: No: 220329091GZU-002 Version: 21 August 2017 Page 3 of 10 FCC Part 15.225-a CONTENT TEST REPORT ........................................................................................................................... 1 CONTENT ............................................................................................................................. 3 1.0 TEST RESULT SUMMARY ............................................................................................ 4 2.0 GENERAL DESCRIPTION ............................................................................................. 5 2.1 PRODUCT DESCRIPTION ........................................................................................................ 5 2.2 TEST FACILITY ..................................................................................................................... 5 2.3 EUT EXERCISING SOFTWARE ................................................................................................. 5 2.4 SPECIAL ACCESSORIES .......................................................................................................... 5 2.5 EQUIPMENT MODIFICATION ................................................................................................. 6 2.6 SUPPORT EQUIPMENT LIST AND DESCRIPTION .......................................................................... 7 3.0 EMF TEST ................................................................................................................. 9 3.1 STANDARD REQUIREMENT .......................................................................................................... 9 3.2 TEST DATA ............................................................................................................................. 10 4.0 TEST EQUIPMENT LIST ............................................................................................. 10 TEST REPORT Intertek Report: No: 220329091GZU-002 Version: 21 August 2017 Page 4 of 10 FCC Part 15.225-a 1.0 TEST RESULT SUMMARY Classification of EUT: Class B Test Item Standard Result EMF 47 CFR PART 1, Subpart I, Section 1.1310 PASS Remark: When determining the test results, measurement uncertainty of tests has been considered. TEST REPORT Intertek Report: No: 220329091GZU-002 Version: 21 August 2017 Page 5 of 10 FCC Part 15.225-a 2.0 General Description 2.1 Product Description Operating Frequency 120-203KHz Type of Modulation: ASK Antenna Type Inductive loop coil antenna Power Supply: Battery Capacity: 1520.64Wh (21.6V, 70.4Ah) Output: AC (3X) :110V~60Hz, Rated power 1200W each port, 2400W Surge, Total 1200W Pure Sine Wave USB-C PD (1X): 5VDC 3A, 9VDC 3A, 12VDC 3A, 15VDC 3A, 20VDC 5A, 100W Max USB-A (2X): 5VDC 3A, each port, Total 30W Max USB-C (2X): 5VDC 3A, each port, Total 30W Max Wireless Charging: 10W Car Port&DC5521 (2X): 12VDC 10A each port, Total 120W Max Total DC+AC Output 1200W Max Input: Solar DC: 12-30V, 400W Max USB-C PD (1X): 5VDC 3A, 9VDC 3A, 12VDC 3A, 15VDC 3A, 20VDC 5A, 100W Max,Total DC+USB-C PD Input 500W Max Operating Temp: 0-40°C Power cord: wires unscreened cable 2.2 Test Facility Room102/104, No 203, KeZhu Road, Science City, GETDD Guangzhou, China A2LA Certificate Number 0078.10 Intertek Testing Services Shenzhen Ltd. Guangzhou Branch is accredited by A2LA and Listed in FCC website. FCC accredited test labs may perform both Certification testing under Parts 15 and 18 and Declaration of Conformity testing. 2.3 EUT Exercising Software N/A 2.4 Special Accessories N/A TEST REPORT Intertek Report: No: 220329091GZU-002 Version: 21 August 2017 Page 6 of 10 FCC Part 15.225-a 2.5 Equipment Modification Any modifications installed previous t…
Text truncated - open the document above for the full version.
BioLite Inc. TEST REPORT SCOPE OF WORK EMC TESTING–BGB0101 REPORT NUMBER 220329091GZU-001 ISSUE DATE [REVISED DATE] 19-August-2022 [---------------------] PAGES 24 DOCUMENT CONTROL NUMBER FCC Part 15C -c © 2017 INTERTEK TEST REPORT Room 02, & 101/E201/E301/ E401/E501/E601/E701/E801 of Room 01 1-8/F., No. 7-2. Caipin Road, Science City, GETDD, Guangzhou, Guangdong, China Telephone: +86 20 8213 9688 Facsimile: +86 20 3205 7538 www.intertek.com.cn This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Testing Services Shenzhen Ltd. Guangzhou Branch Room 02, & 101/E201/E301/E401/E501/E601/E701/E801 of Room 01 1-8/F., No. 7-2. Caipin Road, Science City, GETDD, Guangzhou, Guangdong, China Version: 03 September 2021 Page 2 of 24 FCC Part 15C-c Applicant Name & Address : BioLite Inc. 65 Jay Street 3rd Floor, Brooklyn, NY 11201 United States Manufacturing Site : Dongguan DBK Energy Technology Co., Ltd No. 252, Zhangmutou Section, Dongshen Rd., Zhangmutou Town, DONGGUAN CITY, Guangdong Province China Intertek Report No: FCC ID: 220329091GZU-001 2A3GZBGB Test standards 47 CFR PART 15 Subpart C:2020 Sample Description Product : BaseCharge 1500 Model No. : BGB0101 Electrical Rating : See page 5 Serial No. : Not Labeled Date Received : 29 March 2022 Date Test Conducted : 18 July 2022-25 July 2022 Prepared and Checked By Elena Lei Engineer Approved By: Dean Liu Project Engineer TEST REPORT Intertek Report No.: 220329091GZU-001 Version: 03 September 2021 Page 3 of 24 FCC Part 15C-c CONTENT TEST REPORT ........................................................................................................................... 1 CONTENT ............................................................................................................................. 3 1.0 TEST RESULT SUMMARY ............................................................................................ 4 2.0 GENERAL DESCRIPTION .............................................................................................. 5 2.1 PRODUCT DESCRIPTION ........................................................................................................ 5 2.2 RELATED SUBMITTAL(S) GRANTS ............................................................................................ 5 2.3 TEST METHODOLOGY ........................................................................................................... 5 2.4 TEST FACILITY ...................................................................................................................... 6 3.0 SYSTEM TEST CONFIGURATION .................................................................................. 6 3.1 JUSTIFICATION ..................................................................................................................... 6 3.2 EUT EXERCISING SOFTWARE.................................................................................................. 8 3.3 SPECIAL ACCESSORIES ........................................................................................................... 8 3.4 MEASUREMENT UNCERTAINTY ............................................................................................... 8 3.5 EQUIPMENT MODIFICATION .................................................................................................. 9 3.6 SUPPORT EQUIPMENT LIST AND DESCRIPTION .......................................................................... 9 4.0 RADIATED EMISSION ............................................................................................... 11 5.0 OCCUPIED BANDWIDTH ........................................................................................... 19 6.0 CONDUCTED EMISSION TEST ................................................................................... 21 7.0 TEST EQUIPMENT LIST ............................................................................................. 24 TEST REPORT Intertek Report No.: 220329091GZU-001 Version: 03 September 2021 Page 4 of 24 FCC Part 15C-c 1.0 TEST RESULT SUMMARY Test Item Test Requirement Test Method Result Conducted disturbance voltage at mains ports FCC PART 15 C section 15.207 ANSI C63.10: Clause 6.2 PASS Radiated Emission FCC PART 15 C section 15.209 ANSI C63.10: Clause 6.4 & 6.5 PASS 20dB Bandwidth FCC PART 15 C section 15.215 FCC PART 15 C section 15.215 PASS Remark: When determining the test results, measurement uncertainty of tests has been considered. TEST REPORT Intertek Report No.: 220329091GZU-001 Version: 03 September 2021 Page 5 of 24 FCC Part 15C-c 2.0 General Description 2.1 Product Description Operating Frequency 120-203KHz Type of Modulation: ASK Antenna Type Inductive loop coil antenna Power Supply: Battery Capacity: 1520.64Wh (21.6V, 70.4Ah) Output: AC (3X) :110V~60Hz, Rated power 1200W each port, 2400W Surge, Total 1200W Pure Sine Wave USB-C PD (1X): 5VDC 3A, 9VDC 3A, 12VDC 3A, 15VDC 3A, 20VDC 5A, 100W Max USB-A (2X): 5VDC 3A, each port, Total 30W Max USB-C (2X): 5VDC 3A, each port, Total 30W Max Wireless Charging: 10W Car Port&DC5521 (2X): 12VDC 10A each port, Total 120W Max Total DC+AC Output 1200W Max Input: Solar DC: 12…
Text truncated - open the document above for the full version.
Note:EUT is positioned at the center of the turntable to keep 3 m between the measurement antenna and EUT for the radiated emissions measurements Radiated Emission (30MHz-1000MHz) Radiated Emission (30MHz-1000MHz) Conducted disturbance voltage at mains ports(150KHz-30MHz)
lock E, No.7-2 Guang Dong Software Science Park, C · Guangzhou, Guangdong · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.12 MHz - 0.203 MHz | - |