FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Lepro Innovation INC/
  3. 2A3MAP1

2A3MAP1Smart Plug

Lepro Innovation INC
Smart Plug - FCC ID 2A3MAP1 - Lepro Innovation INC
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 18, 2024
Application Purpose
Original Equipment
Date of Application
Sep 18, 2024
Equipment Note
Smart Plug
Frequency Range
2412.00000000 - 2462.00000000
Company
Lepro Innovation INC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

External Photos

Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W53070E-RF-EXP Page 1 / 3 EUT EXTERNAL PHOTOS Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W53070E-RF-EXP Page 2 / 3 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W53070E-RF-EXP Page 3 / 3

Internal Photos

Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W53070E-RF-INP Page 1 / 6 EUT INTERNAL PHOTOS Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W53070E-RF-INP Page 2 / 6 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W53070E-RF-INP Page 3 / 6 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W53070E-RF-INP Page 4 / 6 Bluetooth&Wifi Antenna Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W53070E-RF-INP Page 5 / 6 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W53070E-RF-INP Page 6 / 6

RF Exposure Info

MAXIMUM PERMISSIBLE EXPOSURE EVALUATION REPORT Applicant: Lepro Innovation INC Address: 3651 Lindell Road Suite D1048, Las Vegas, Nevada 89103, United States P r o d u c t N a m e : Smart Plug F C C I D : 2A3MAP1 Standard(s): 47 CFR §1.1310, 47 CFR §2.1091, 47 CFR §15.247(i) Report Number: 2402W53070E-RF-00D Report Date: 2024/8/20 The above device has been tested and found compliant with the requirement of the relative standards by Bay Area Compliance Laboratories Corp. (Dongguan). Reviewed By: Gavin Xu Approved By: Ivan Cao Title: RF Engineer Title: EMC Manager Bay Area Compliance Laboratories Corp. (Dongguan) No.12, Pulong East 1 st Road, Tangxia Town, Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 www.baclcorp.com.cn Note: The information marked ▲ is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with ★.This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: 2402W53070E-RF-00D Report Template Version: FCC §2.1091-V1.0 Page 2 of 6 CONTENTS DOCUMENT REVISION HISTORY .......................................................................................... 3 1. GENERAL INFORMATION .................................................................................................... 4 1.1 GENERAL DESCRIPTION OF EQUIPMENT UNDER TEST ..................................................................... 4 2. RF EXPOSURE EVALUATION (MPE) .................................................................................. 5 2.1 RF EXPOSURE EVALUATION ............................................................................................................... 5 2.1.1 Applicable Standard ....................................................................................................................................... 5 2.1.2 Calculation formula: ...................................................................................................................................... 5 2.1.3 Calculated Data: ............................................................................................................................................. 5 APPENDIX A - EUT PHOTOGRAPHS ...................................................................................... 6 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: 2402W53070E-RF-00D Report Template Version: FCC §2.1091-V1.0 Page 3 of 6 DOCUMENT REVISION HISTORY Revision Number Report Number Description of Revision Date of Revision 1.0 2402W53070E-RF-00D Original Report 2024/8/20 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: 2402W53070E-RF-00D Report Template Version: FCC §2.1091-V1.0 Page 4 of 6 1. GENERAL INFORMATION 1.1 General Description Of Equipment under Test EUT Name: Smart Plug EUT Model: P1 Rated Input Voltage: AC 120V EUT Received Date: 2024/8/3 EUT Received Status: Good Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: 2402W53070E-RF-00D Report Template Version: FCC §2.1091-V1.0 Page 5 of 6 2. RF EXPOSURE EVALUATION (MPE) 2.1 RF Exposure Evaluation 2.1.1 Applicable Standard According to subpart 15.247(i) and subpart §1.1310, systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. Limits for Maximum Permissible Exposure (MPE) (§1.1310, §2.1091) (B) Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Averaging Time (minutes) 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f²) 30 30–300 27.5 0.073 0.2 30 300–1500 / / f/1500 30 1500–100,000 / / 1.0 30 f = frequency in MHz; * = Plane-wave equivalent power density; According to §1.1310 and §2.1091 RF exposure is calculated. 2.1.2 Calculation formula: Prediction of power density at the distance of the applicable MPE limit S = PG/4R² = power density (in appropriate units, e.g. mW/cm 2 ); P = power input to the antenna (in appropriate units, e.g., mW); G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain factor, is normally numeric gain; R = distance to the center of radiation of the antenna (appropriate units, e.g., cm); 2.1.3 Calculated Data: Operation Modes Frequency (MHz) Antenna Gain Conducted output power including Tune-up Tolerance Evaluation Distance (cm) Power Density (mW/cm 2 ) MPE Limit (mW/cm 2 ) (dBi) (numeric)(dBm)(mW) BLE 2402-24804.16 2.61 19.589.13 20.000.046 1.0 2.4G Wifi 2412-24624.16 2.61 24.5281.84 20.00 0.146 1.0 Note: The Conducted output power including Tune-up Tolerance provided by manufacturer. 2.4G Wifi and BLE can’t transmit simultaneously. Result: Compliant. The device compliant Simultaneous transmission at 20cm distances. Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: 2402W53070E-RF-00D Report Template Version: FCC §2.1091-V1.0 Page 6 of 6 EXHIBI A - EUT PHOTOGRAPHS Please refer to the attachment 2402W53070E-RF-EXP EUT EXTERNAL PHOTOGRAPHS and 2402W53070E-RF-INP EUT INTERNAL PHOTOGRAPHS. ***** END OF REPORT *****

Test Report

OTA TEST REPORT TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in ANSI/IEEE Std 149-2008. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Prepared by: Peng Tao Approved by: Kai Xu TA Technology (Shanghai) Co., Ltd. No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China TEL: +86‐021‐50791141/2/3 FAX: +86‐021‐50791141/2/3‐8000 Applicant Espressif System (Shanghai) Co.,Ltd Product ESP32-C3-MINI-1 Model ESP-ANT D-H Report No. Y2102A0260-T2 Issue Date March 9, 2021 OTA Test Report Report No: Y2102A0260-T2 TA Technology (Shanghai) Co., Ltd. TA-MB-04-008O P age 2 of 13 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. TABLE OF CONTENTS 1. Test Laboratory .............................................................................................................................. 3 1.1. Notes of the Test Report ................................................................................................... 3 1.2. Test facility ........................................................................................................................ 3 1.3. Testing Location ................................................................................................................ 3 1.4. Laboratory Environment .................................................................................................... 4 2. General Description of Equipment under Test ............................................................................... 5 2.1. Applicant and Manufacturer Information ............................................................................ 5 2.2. General information ........................................................................................................... 5 2.3. Test Date ........................................................................................................................... 5 2.4. Receiving Date .................................................................................................................. 5 2.5. Applied Standards ............................................................................................................. 6 3. Test Conditions .............................................................................................................................. 7 3.1. Test Configuration ............................................................................................................. 7 3.2. Test Measurement ............................................................................................................. 7 4. Test Results ................................................................................................................................... 8 4.1. Gain and Efficiency ............................................................................................................ 8 5. Equipment List ............................................................................................................................... 9 ANNEX A 3-D Pattern Plots ................................................................................................................... 10 ANNEX B:The EUT Appearance and Test Configuration ...................................................................... 12 B.1 EUT Appearance ................................................................................................................... 12 B.2 Test Configuration ................................................................................................................. 13 OTA Test Report Report No: Y2102A0260-T2 TA Technology (Shanghai) Co., Ltd. TA-MB-04-008O P age 3 of 13 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 1. Test Laboratory 1.1. Notes of the Test Report This report shall not be reproduced in full or partial, without the written approval of TA technology (shanghai) co., Ltd. The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein .Measurement Uncertainties were not taken into account and are published for informational purposes only. This report is written to support regulatory compliance of the applicable standards stated above. 1.2. Test facility A2LA (Certificate Number: 3857.01) TA Technology (Shanghai) Co., Ltd. has been listed by American Association for Laboratory Accreditation to perform measurement. 1.3. Testing Location Company: TA Technology (Shanghai) Co., Ltd. Address: No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China City: Shanghai Post code: 201201 Country: P. R. China Contact: Xu Kai Telephone: +86-021-50791141/2/3 Fax: +86-021-50791141/2/3-8000 Website: http://www.ta-shanghai.com E-mail: [email protected] OTA Test Report Report No: Y2102A0260-T2 TA Technology (Shanghai) Co., Ltd. TA-MB-04-008O P age 4 of 13 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 1.4. Laboratory Environment Temperature Min. =19°C,Max. = 25°C Relative humidity Min. =40%,Max. =72% Shield effect 0.7-6GHz > 100dB Ground resistance <0.5 OTA Test Report Report No: Y2102A0260-T2 TA Technology (Shanghai) Co., Ltd. TA-MB-04-008O P age 5 of 13 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 2. General Description of Equipment under Test 2.1. Applicant and Manufacturer Information Applicant Name Espressif System (Shanghai) Co.,Ltd Applicant address Suite 204 Block 2, 690 Bibo Road, Zhang Jiang Hi-Tech Park, Shanghai, China Manufacturer Name Espressif System (Shanghai) Co.,Ltd Manufacturer address Suite 204 Block 2, 690 Bibo Road, Zhang Jiang Hi-Tech Park, Shanghai, China 2.2. …

Text truncated - open the document above for the full version.

Test Report

TEST REPORT Applicant: Lepro Innovation INC Address: 3651 Lindell Road Suite D1048, Las Vegas, Nevada 89103, United States P r o d u c t N a m e : Smart Plug F C C I D : 2A3MAP1 I C : 27538-P1 HVIN: P1 Standard(s): 47 CFR Part 15, Subpart C(15.247) RSS-247 Issue 3, August 2023 RSS-Gen, Issue 5, February 2021 Amendment 2 ANSI C63.10-2013 KDB 558074 D01 15.247 Meas Guidance v05r02 Report Number: 2402W53070E-RF-00A Report Date: 2024/9/13 The above device has been tested and found compliant with the requirement of the relative standards by Bay Area Compliance Laboratories Corp. (Dongguan). Reviewed By: Gavin Xu Approved By: Ivan Cao Title: RF Engineer Title: EMC Manager Bay Area Compliance Laboratories Corp. (Dongguan) No.12, Pulong East 1 st Road, Tangxia Town, Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 www.baclcorp.com.cn Note: The information marked ▲ is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with ★.This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. Bay Area Compliance Laboratories Corp. (Dongguan) Report No.:2402W53070E-RF-00A Report Template Version: FCC+IC-Wi-Fi2.4-V1.0 Page 2 of 54 CONTENTS DOCUMENT REVISION HISTORY .......................................................................................... 4 1. GENERAL INFORMATION .................................................................................................... 5 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................... 5 1.2 ACCESSORY INFORMATION ................................................................................................................. 5 1.3 ANTENNA INFORMATION DETAIL▲ ................................................................................................... 5 1.4 EQUIPMENT MODIFICATIONS ............................................................................................................. 5 2. SUMMARY OF TEST RESULTS ............................................................................................ 6 3. DESCRIPTION OF TEST CONFIGURATION ..................................................................... 7 3.1 OPERATION FREQUENCY DETAIL ....................................................................................................... 7 3.2 EUT OPERATION CONDITION ............................................................................................................. 7 3.3 SUPPORT EQUIPMENT LIST AND DETAILS ......................................................................................... 7 3.4 SUPPORT CABLE LIST AND DETAILS .................................................................................................. 8 3.5 BLOCK DIAGRAM OF TEST SETUP ...................................................................................................... 8 3.6 TEST FACILITY ................................................................................................................................... 10 3.7 MEASUREMENT UNCERTAINTY ........................................................................................................ 10 4. REQUIREMENTS AND TEST PROCEDURES .................................................................. 11 4.1 AC LINE CONDUCTED EMISSIONS .................................................................................................... 11 4.1.1 Applicable Standard ..................................................................................................................................... 11 4.1.2 EUT Setup.................................................................................................................................................... 13 4.1.3 EMI Test Receiver Setup ............................................................................................................................. 13 4.1.4 Test Procedure ............................................................................................................................................. 14 4.1.5 Corrected Amplitude & Margin Calculation ................................................................................................ 14 4.1.6 Test Result ................................................................................................................................................... 14 4.2 RADIATION SPURIOUS EMISSIONS .................................................................................................... 15 4.2.1 Applicable Standard ..................................................................................................................................... 15 4.2.2 EUT Setup.................................................................................................................................................... 15 4.2.3 EMI Test Receiver & Spectrum Analyzer Setup ......................................................................................... 17 4.2.4 Test Procedure ............................................................................................................................................. 17 4.2.5 Corrected Amplitude & Margin Calculation ................................................................................................ 17 4.2.6 Test Result ......................................................................…

Text truncated - open the document above for the full version.

Test Report

TEST REPORT Applicant: Lepro Innovation INC Address: 3651 Lindell Road Suite D1048, Las Vegas, Nevada 89103, United States P r o d u c t N a m e : Smart Plug F C C I D : 2A3MAP1 I C : 27538-P1 HVIN: P1 Standard(s): 47 CFR Part 15, Subpart C(15.247) RSS-247 Issue 3, August 2023 RSS-Gen, Issue 5, February 2021 Amendment 2 ANSI C63.10-2013 KDB 558074 D01 15.247 Meas Guidance v05r02 Report Number: 2402W53070E-RF-00B Report Date: 2024/8/23 The above device has been tested and found compliant with the requirement of the relative standards by Bay Area Compliance Laboratories Corp. (Dongguan). Reviewed By: Gavin Xu Approved By: Ivan Cao Title: RF Engineer Title: EMC Manager Bay Area Compliance Laboratories Corp. (Dongguan) No.12, Pulong East 1 st Road, Tangxia Town, Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 www.baclcorp.com.cn Note: The information marked ▲ is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with ★.This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. Bay Area Compliance Laboratories Corp. (Dongguan) Report No.:2402W53070E-RF-00B Report Template Version: FCC+IC-BLE-V1.2 Page 2 of 50 CONTENTS DOCUMENT REVISION HISTORY .......................................................................................... 4 1. GENERAL INFORMATION .................................................................................................... 5 1.1 GENERAL DESCRIPTION OF EQUIPMENT UNDER TEST ..................................................................... 5 1.2 ACCESSORY INFORMATION ................................................................................................................. 5 1.3 ANTENNA INFORMATION DETAIL▲ ................................................................................................... 5 1.4 EQUIPMENT MODIFICATIONS ............................................................................................................. 5 2. SUMMARY OF TEST RESULTS ............................................................................................ 6 3. DESCRIPTION OF TEST CONFIGURATION ..................................................................... 7 3.1 OPERATION FREQUENCY DETAIL ....................................................................................................... 7 3.2 EUT OPERATION CONDITION ............................................................................................................. 7 3.3 SUPPORT EQUIPMENT LIST AND DETAILS ......................................................................................... 7 3.4 SUPPORT CABLE LIST AND DETAILS .................................................................................................. 7 3.5 BLOCK DIAGRAM OF TEST SETUP ...................................................................................................... 8 3.6 TEST FACILITY ................................................................................................................................... 10 3.7 MEASUREMENT UNCERTAINTY ........................................................................................................ 10 4. REQUIREMENTS AND TEST PROCEDURES .................................................................. 11 4.1 AC LINE CONDUCTED EMISSIONS .................................................................................................... 11 4.1.1 Applicable Standard ..................................................................................................................................... 11 4.1.2 EUT Setup.................................................................................................................................................... 13 4.1.3 EMI Test Receiver Setup ............................................................................................................................. 13 4.1.4 Test Procedure ............................................................................................................................................. 14 4.1.5 Corrected Amplitude & Margin Calculation ................................................................................................ 14 4.1.6 Test Result ................................................................................................................................................... 14 4.2 RADIATION SPURIOUS EMISSIONS .................................................................................................... 15 4.2.1 Applicable Standard ..................................................................................................................................... 15 4.2.2 EUT Setup.................................................................................................................................................... 15 4.2.3 EMI Test Receiver & Spectrum Analyzer Setup ......................................................................................... 17 4.2.4 Test Procedure ............................................................................................................................................. 17 4.2.5 Corrected Amplitude & Margin Calculation ................................................................................................ 17 4.2.6 Test Result ....................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W53070E-RF-00B-TSP TEST SETUP PHOTOGRAPHS Conducted Emissions Front View Conducted Emissions Side View Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W53070E-RF-00B-TSP Radiated Emission 9k-30MHz Parallel View Radiated Emission 9k-30MHz Perpendicular View Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W53070E-RF-00B-TSP Radiated Emission 9k-30MHz Ground-parallel View Radiated Emission 30M-1GHz View Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W53070E-RF-00B-TSP Radiated Emission 1-18GHz View Radiated Emission 18-25GHz View

Contact Information

Applicant

Vich Xun(QM Director)
[email protected]62872558Fax: 62872558

Test Firm

Bay Area Compliance Laboratories Corp (Shenzhen)Well Wang
[email protected]86-755-33320018

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz280.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Lepro Innovation INC

Smart LED Floor Lamp - FCC ID 2A3MAO1 - Lepro Innovation INC
2A3MAO1

Smart LED Floor Lamp

Sep 11, 2024

Equipment Class

DTS - Digital Transmission System
Smart LED Strip lights - FCC ID 2A3MASE1 - Lepro Innovation INC
2A3MASE1

Smart LED Strip lights

Aug 29, 2024

Equipment Class

DTS - Digital Transmission System
AI LED outdoor string lights - FCC ID 2A3MAZB1 - Lepro Innovation INC
2A3MAZB1

AI LED outdoor string lights

Jul 18, 2024

Equipment Class

DTS - Digital Transmission System
Smart LED downlight /Spot LED intelligent - FCC ID 2A3MAR2 - Lepro Innovation INC
2A3MAR2

Smart LED downlight /Spot LED intelligent

Mar 17, 2024

Equipment Class

DTS - Digital Transmission System
2A3MAWL1

Smart LED Wall Light

Jan 21, 2024

Equipment Class

DTS - Digital Transmission System