2A3PR-GC3Indoor Cam

Kalado LLC
Indoor Cam - FCC ID 2A3PR-GC3 - Kalado LLC
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
May 09, 2026
Application Purpose
Original Equipment
Equipment Note
Indoor Cam
Frequency Range
2412.00000000 - 2462.00000000
Company
Kalado LLC
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

KALADOLLC 3120139thAveSE,5thFloor,Bellevue,WA98005 AttestationStatements NotCoveredEntityApplicant&NotCoveredEquipment To:FederalCommunicationsCommissionDate:Apr.28,26 7435OaklandMillsRoad, Columbia,MD21046,USA Ref:InformationRequiredbySection2.911(d)(5)(i)&(ii) FCCID:2A3PR-GC3 KALADOLLC(“theapplicant”)certifiesthat,asofthedateofthefilingoftheapplication,theapplicantis notidentifiedontheCoveredList,establishedpursuantto§1.50002ofreferencechapter,asanentity producing“covered”communicationequipment.Theequipmentforwhichauthorizationissoughtisnot “covered”telecommunicationsequipmentandvideosurveillanceequipmentproducedbyentities identifiedontheCommission’sCoveredListthatprohibitedfromreceivinganequipmentauthorization pursuanttosection§2.903oftheFCCrules. Sincerelyyours, ApplicantSignature PrintedName:JackTian Title:Manager Address:3120139thAveSE,5thFloor,Bellevue,WA98005 Tel.:+8615625296304 Email:[email protected]

Attestation Statements

KALADOLLC Address:3120139thAveSE,5thFloor,Bellevue,WA98005 1|Page AttestationStatements To:FederalCommunicationsCommissionDate:Apr.28,26 7435OaklandMillsRoad, Columbia,MD21046,USA Subject:AttestationofCompliancewithFCCCoveredListSoftwareRequirements FCCID:[2A3PR-GC3] ProductName:[IndoorCam] Thisletterservesasanattestationthattheequipmentidentifiedabove☐is/☒isnot(selectone)"covered" softwareasdefinedundertheFederalCommunicationsCommission(FCC)CoveredListrequirements,as outlinedinFCC22-84andKDB986446. Specifically,theundersignedcertifiesthattheequipmentforwhichauthorizationissought: 1.Doesnotcontaincybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab, Inc.oranyofitssuccessors,assignees,parents,subsidiaries,affiliates,oranyentitythathasrebranded orrelabeledsoftwareproducedbytheaforementionedentities. 2.Doesnothavethecapabilitytostore,run,ordeliveranysoftwareidentifiedontheFCCCoveredList, includingbutnotlimitedtocybersecurityandanti-virussoftware. Tosupportthisattestation,theappendixevaluationdocumentationhasbeenpreparedandisincludedinthe certificationfiling. Thisattestationisbasedonathoroughevaluationofthedevice'sdesign,functionality,andsoftware environment.Theundersignedaffirmsthattheinformationprovidedisaccurateandcompletetothebestof theirknowledge. Sincerelyyours, ApplicantSignature PrintedName:JackTian Title:Manager Address:3120139thAveSE,5thFloor,Bellevue,WA98005 Tel.:+8615625296304 Email:[email protected] KALADOLLC Address:3120139thAveSE,5thFloor,Bellevue,WA98005 2|Page EvaluationregardingtotheCoveredListSoftware: Compliance Methodology EvaluationProcessResults Deviceis Inherent compliance ☒ TheChipset(s)usedislimitedtorun theCybersecurityoranti-virus software. Compliance ☒ TheMemoryusedislimitedtorunthe Cybersecurityoranti-virussoftware. Compliance ☒ Thereisstoragecapacitylimitationfor storeorinstalltheCybersecurityor anti-virussoftware. Compliance ☒ Operatingsystemusedislimitedto run,installordelivertheCybersecurity oranti-virussoftware. Compliance Deviceisnot Inherent compliance ☐ EvaluationBasedonSoftware BillofMaterials(SBoM) Seeattached“SBoM“ Note:TheSBoMcontentislimited tothescopeofcoveredlist software(e.g.antivirusand cybersecuritysoftware). ☐ EvaluationBasedonScanfor Softwareonthedevice ☐ EvaluationBasedonFilesystemscan ☐ EvaluationBasedonRunning softwarecheck

Attestation Statements

KALADOLLC Address:3120139thAveSE,5thFloor,Bellevue,WA98005 U.S.AgentLetterofAttestation To:FederalCommunicationsCommission 7435OaklandMillsRoad,Columbia,MD21046,USA Date:May.8,26 Ref:AttestationStatement–Part2.911(d)(7)filing FCCID:2A3PR-GC3 [KALADOLLC](“theapplicant”)certifiesthat,asofthedateofthefilingoftheapplication,[CELLT INC.](“theagent”)isourdesignatedU.S.agentforserviceofprocessfortheabovereferenceFCC ID.TheapplicantacceptstomaintainanagentforserviceofprocessintheUnitedStatesfornoless thanoneyearaftereitherthegranteehaspermanentlyterminatedallmarketingandimportationof theapplicableequipmentwithintheU.S.,ortheconclusionofanyCommission-related administrativeorjudicialproceedinginvolvingtheequipment,whicheverislater.Theapplicant furtheracknowledgesitisourresponsibilitytoinformtheFCCwhenevertheagentinformation changes. [CELLTINC.]("theagent)understanditistheagent'sobligationtoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipment,andatthephysicalU.S.addressand emailaddress. DesignatedU.S.Agent CompanyName:CELLTINC. FRN:0036412567 GC:N/A Address:140121STST#12958SACRAMENTO,CA 95811UnitedStates Signature: ContactPerson:ThompsonLim Tel:001-424-3474188Email:[email protected] Applicant CompanyName:KALADOLLC FRN:0031649858 Address:3120139thAveSE,5thFloor,Bellevue,WA 98005 Signature: ContactPerson:JackTian Tel:15625296304Email:[email protected]

Cover Letter(s)

KALADOLLC Address:3120139th Ave SE, 5th Floor, Bellevue,WA 98005 (Apr. 28, 26 ) FederalCommunicationsCommission Authorizationand EvaluationDivision 7435 OaklandMills Road Columbia,MD 21046 Subject:ConfidentialityRequestfor: FCCID:2A3PR-GC3 Pursuantto Sections0.457 and 0.459 of the Commission’s Rules,we herebyrequestpermanent confidentialtreatmentof the exhibitsaccompanyingthis certificationapplicationas outlinedbelow:  Block Diagram  Schematics  Operational Description The aboveexhibitscontaintrade secretsand/orproprietaryinformationthat are not publiclyavailableand materialsthat the Applicanthas spent considerableeffortsin developing.Publicdisclosureof these may be harmfulto the Applicantand give an unfair advantageto competitorson the market. Pursuantto DA 04-1705,the applicantalso requeststemporaryconfidentialtreatmentof the exhibits outlinedbelowfor a periodof (up to 180) days from the date of equipmentauthorizationand prior to marketingin the UnitedStatesto preventthe prematurereleaseof any sensitiveinformation.Applicantis awareof their responsibilityto notify DERYCOMin the event informationregardingthe productor the productis made availableto the publicbeforethe requestedperiodhas expired.  User Manual Sincerely, (Signature) Title: Manager Address:3120 139th Ave SE, 5th Floor, Bellevue,WA 98005 Tel.: +86 15625296304 Email: [email protected]

Cover Letter(s)

KALADOLLC Address:3120139thAveSE,5thFloor,Bellevue,WA98005 (May.8,26) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:AgentAuthorizationforFCCID:2A3PR-GC3 I,theundersigned,herebyauthorize(ShenzhenNTTTestingTechnologyCo.,Ltd.)toactonourbehalfin allmattersrelatingtothisapplicationforequipmentcertification. Anyactcarriedoutby(ShenzhenNTTTestingTechnologyCo.,Ltd.)shallhavethesameeffectasour ownandIacknowledgethatallresponsibilityforcomplyingwiththetermsandconditionsofcertification, asspecifiedbyDERYCOMCERTIFICATIONSERVICES,INC.,stillresideswith(KALADOLLC). WecertifythatwearenotsubjecttoadenialoffederalbenefitsthatincludesFCCbenefitspursuantto Section5301oftheAnti-DrugAbuseActof1988,21U.S.C.§862,andthatnopartytotheapplication,as definedin47CFR§1.2002(b),issubjecttoadenialoffederalbenefitsthatincludesFCCbenefits pursuanttothatsection. Sincerely, (Signature) (FullnameofcontactpersonlistedonFCC’swebsite) (Title):Manager Tel:+8615625296304 Fax:N/A Email:[email protected]

Cover Letter(s)

KALADOLLC ProductSimilarityDeclaration Productname:IndoorCam Modelname: GC3,GC1,GC1Pro,GC2,GC2Pro,GC3,GC3Pro,GC4,GC4Pro,GC5,GC5Pr o,GC6,GC7,GC8,GC9,GC10,GC11, M1,GM1,GM1Pro,GM2,GM2Pro,GM3,GM3Pro,GM4,GM4Pro,GM5,GM5 Pro,GM6,GM7,GM8,GM9,GM10,GM11 Trademark:N/A FCCID:2A3PR-GC3 We(KALADOLLC)herebystatethatallthemodelsareelectrical identicalincludingthesamesoftwareparameterandhardware design(i.e.,circuitdesign,PCBLayout,RFmodule/circuit, antennatype(s)andantennalocation,componentsonPCB,etc.,), samemechanicalstructureanddesign(includingproduct enclosure,materials,etc.,),theonlydifferencearethemodel numberandappearance(basesupport). Signature: Name:JackTian Title: Place,date:Shenzhen,2026.04.28

External Photos

Page 1 of 4 FCCID:2A3PR-GC3 ExternalPhotos Page 2 of 4 Page 3 of 4 Page 4 of 4

Internal Photos

Page 1 of 3 FCCID:2A3PR-GC3 InternalPhotos Page 2 of 3 WIFIAnt Page 3 of 3

RF Exposure Info

FCC ID: 2A3PR-GC3 RF Exposure Evaluation According to KDB 447498 D01 General RF Exposure Guidance v06 and part 2.1091,Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition(s), listed below, is (are) satisfied. Limits The criteria listed in the following table shall be usedto evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (A) Limits for Occupational/Controlled Exposures 0.3–3.06141.63*(100)6 3.0–301842/f4.89/f*(900/f 2 )6 30–30061.40.1631.06 300–1500f/3006 1500–100,00056 (B) Limits for General Population/Uncontrolled Exposure 0.3–1.346141.63*(100)30 1.34–30824/f2.19/f*(180/f 2 )30 30–30027.50.0730.230 300–1500f/150030 1500–100,0001.030 f = frequency in MHz Friis transmission formula:Pd = (Pout*G)/(4*pi*r 2 ) Where Pd= power density in mW/cm 2 ,Pout= output power to antenna in mW; G= gain of antenna in linear scale,Pi=3.1416; R= distance between observation point and center of the radiator in cm Pd id the limit of MPE, 1 mW/cm 2 . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. Test Procedure Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. Test Result of RF Exposure Evaluation Remark : So a SAR test is not required Operating Mode Frequency Measured Power Tune up tolerance Max. Tune up Power Antenna Gain Power Density at R=20cm Power Density Limit Result (MHz)(dBm)(dBm)(dBm)(dBi)(mW/cm 2 ) (mW/cm 2 ) WiFi 2.4G 2412-246212.54 12±1 132.30.0067411.0PASS

Test Report

深圳市天联凌科技有限公司 ShenzhenSKYLinkTechnologyCo.,Ltd 天线规格承认书 编号:SLSOA20240407CS01 客户名称: 鲸视 项目名称:TY06 双频天线 产品描述:弹片天线 客户料号: 我司料号: TY06 版 本: V1.0 (第一次发行) 日 期: 2024.04.07 客户 工程 采购 承认 天联凌 研发 工程 审核 此承认书严禁修改 规格概述 电特性 频率 2400MHz~2500MHz 5150MHz~5850MHz 回波损耗 <-10dB 效率 >50% 增益 2.3dbi 阻抗 50 欧姆 极化方式线极化 材料和机械特性 材料弹片 线材类型 / 端子类型/ 图纸尺寸详见图纸 丝印方式/ 环境特性 储存温度 -30 ̊C~+85 ̊C FPC 焊接温度 280 ± 5 °C 浸渍时间 :10 秒 射频线焊接温度 320 ± 5 °C 2-3 秒 R&DCenter:Room D5 th FloorBuildingL,BlockE,71BaochengDistrict,BaoanDistrict,Shenzhen Factory:6Floor,GangHuaXingIndustrialPark,RongshuRoad 2 nd ,Fuyong,Baoan,shenzhen Email:[email protected]  TestEquipment&Conditions 1.NetworkAnalyzers: Agilent8753D 5071B CommunicationsTestSet: AgilentE5515C CMW500 2.3DChamberTestSystem R&DCenter:Room D5 th FloorBuildingL,BlockE,71BaochengDistrict,BaoanDistrict,Shenzhen Factory:6Floor,GangHuaXingIndustrialPark,RongshuRoad 2 nd ,Fuyong,Baoan,shenzhen Email:[email protected] 匹配电路 (matchingcircuit) R&DCenter:Room D5 th FloorBuildingL,BlockE,71BaochengDistrict,BaoanDistrict,Shenzhen Factory:6Floor,GangHuaXingIndustrialPark,RongshuRoad 2 nd ,Fuyong,Baoan,shenzhen Email:[email protected] TRP&TIS  ReturnLoss R&DCenter:Room D5 th FloorBuildingL,BlockE,71BaochengDistrict,BaoanDistrict,Shenzhen Factory:6Floor,GangHuaXingIndustrialPark,RongshuRoad 2 nd ,Fuyong,Baoan,shenzhen Email:[email protected]  Gain&Efficiency R&DCenter:Room D5 th FloorBuildingL,BlockE,71BaochengDistrict,BaoanDistrict,Shenzhen Factory:6Floor,GangHuaXingIndustrialPark,RongshuRoad 2 nd ,Fuyong,Baoan,shenzhen Email:[email protected]  RadiationPattern R&DCenter:Room D5 th FloorBuildingL,BlockE,71BaochengDistrict,BaoanDistrict,Shenzhen Factory:6Floor,GangHuaXingIndustrialPark,RongshuRoad 2 nd ,Fuyong,Baoan,shenzhen Email:[email protected] R&DCenter:Room D5 th FloorBuildingL,BlockE,71BaochengDistrict,BaoanDistrict,Shenzhen Factory:6Floor,GangHuaXingIndustrialPark,RongshuRoad 2 nd ,Fuyong,Baoan,shenzhen Email:[email protected] R&DCenter:Room D5 th FloorBuildingL,BlockE,71BaochengDistrict,BaoanDistrict,Shenzhen Factory:6Floor,GangHuaXingIndustrialPark,RongshuRoad 2 nd ,Fuyong,Baoan,shenzhen Email:[email protected]  天线装配方式 R&DCenter:Room D5 th FloorBuildingL,BlockE,71BaochengDistrict,BaoanDistrict,Shenzhen Factory:6Floor,GangHuaXingIndustrialPark,RongshuRoad 2 nd ,Fuyong,Baoan,shenzhen Email:[email protected]  可靠性测试 测试项目测试条件设备规范结果 1 低温测试 温度:-30°C,湿度:65%,时间:48小时 测试条件: 把天线放置在高低温测试箱里,温度保持在 25°C,湿度保持在65%,时间为1小时,然后在1 小时内降低温度到-30°C,保持44小时,再升温 到25°C,保持2小时 高低温测试机 不允许材料变形 电子性能好 通过 2 高温测试 温度:85°C,湿度:85%,时间:48小时 测试条件: 把天线放置在高低温测试箱里,温度保持在 25°C,湿度保持在65%,时间为1小时,然后在1 小时内,把温度升到80°C,湿度为85%,保持44 小时,再把温度降到25°C,保持2小时。 高低温测试机 不允许材料变形 电子性能好 通过 3 盐雾测试 盐雾测试: 把天线放置在盐雾测试机内 设置测试环境: 温度35±2°C 湿度85% 盐雾喷剂:5±1% PH值6.5~7.2 时间:24小时 盐雾测试机 没有颜色变化 没有出现生锈 通过

Test Report

ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page1of48 RFTestData DutyCycle....................................................................................................................................................................2 MaximumAverageConductedOutputPower...............................................................................................................8 -6dBBandwidth..........................................................................................................................................................14 OccupiedChannelBandwidth.....................................................................................................................................20 MaximumPowerSpectralDensityLevel.....................................................................................................................26 BandEdge..................................................................................................................................................................32 ConductedRFSpuriousEmission..............................................................................................................................39 ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page2of48 DutyCycle ConditionModeFrequency(MHz)AntennaDutyCycle(%)CorrectionFactor(dB)1/T(kHz) NVNTb2412Ant180.580.946.02 NVNTb2437Ant186.350.641.07 NVNTb2462Ant186.830.611.07 NVNTg2412Ant181.310.95.75 NVNTg2437Ant181.310.95.75 NVNTg2462Ant181.130.915.81 NVNTn202412Ant180.580.946.02 NVNTn202437Ant180.390.956.1 NVNTn202462Ant180.580.946.02 ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page3of48 DutyCycleNVNTb2412MHzAnt1 DutyCycleNVNTb2437MHzAnt1 ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page4of48 DutyCycleNVNTb2462MHzAnt1 DutyCycleNVNTg2412MHzAnt1 ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page5of48 DutyCycleNVNTg2437MHzAnt1 DutyCycleNVNTg2462MHzAnt1 ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page6of48 DutyCycleNVNTn202412MHzAnt1 DutyCycleNVNTn202437MHzAnt1 ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page7of48 DutyCycleNVNTn202462MHzAnt1 ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page8of48 MaximumAverageConductedOutputPower Conditi on Mod e Frequen cy(MHz) Anten na Conduct edPower (dBm) Duty Fact or (dB) Total Conduct edPower (dBm) Total Conduct edPower (W) Limit Conducted(dB m) Verdi ct NVNTb2412Ant17.850.948.790.0075730Pass NVNTb2437Ant111.90.6412.540.0179530Pass NVNTb2462Ant111.560.6112.170.0164830Pass NVNTg2412Ant18.780.99.680.0092930Pass NVNTg2437Ant19.060.99.960.0099130Pass NVNTg2462Ant18.660.919.570.0090630Pass NVNTn202412Ant17.750.948.690.007430Pass NVNTn202437Ant17.930.958.880.0077330Pass NVNTn202462Ant17.620.948.560.0071830Pass ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page9of48 AveragePowerNVNTb2412MHzAnt1 AveragePowerNVNTb2437MHzAnt1 ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page10of48 AveragePowerNVNTb2462MHzAnt1 AveragePowerNVNTg2412MHzAnt1 ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page11of48 AveragePowerNVNTg2437MHzAnt1 AveragePowerNVNTg2462MHzAnt1 ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page12of48 AveragePowerNVNTn202412MHzAnt1 AveragePowerNVNTn202437MHzAnt1 ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page13of48 AveragePowerNVNTn202462MHzAnt1 ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page14of48 -6dBBandwidth ConditionModeFrequency (MHz) Antenna-6dBBandwidth (MHz) Limit-6dBBandwidth (MHz) Verdict NVNTb2412Ant117.660.5Pass NVNTb2437Ant110.10.5Pass NVNTb2462Ant19.970.5Pass NVNTg2412Ant116.570.5Pass NVNTg2437Ant116.470.5Pass NVNTg2462Ant116.530.5Pass NVNTn202412Ant117.670.5Pass NVNTn202437Ant117.660.5Pass NVNTn202462Ant117.550.5Pass ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page15of48 -6dBBandwidthNVNTb2412MHzAnt1 -6dBBandwidthNVNTb2437MHzAnt1 ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page16of48 -6dBBandwidthNVNTb2462MHzAnt1 -6dBBandwidthNVNTg2412MHzAnt1 ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page17of48 -6dBBandwidthNVNTg2437MHzAnt1 -6dBBandwidthNVNTg2462MHzAnt1 ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page18of48 -6dBBandwidthNVNTn202412MHzAnt1 -6dBBandwidthNVNTn202437MHzAnt1 ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page19of48 -6dBBandwidthNVNTn202462MHzAnt1 ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page20of48 OccupiedChannelBandwidth ConditionModeFrequency(MHz)Antenna99%OBW(MHz) NVNTb2412Ant117.597 NVNTb2437Ant114.747 NVNTb2462Ant114.66 NVNTg2412Ant116.608 NVNTg2437Ant116.583 NVNTg2462Ant116.577 NVNTn202412Ant117.584 NVNTn202437Ant117.572 NVNTn202462Ant117.588 ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page21of48 OBWNVNTb2412MHzAnt1 OBWNVNTb2437MHzAnt1 ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page22of48 OBWNVNTb2462MHzAnt1 OBWNVNTg2412MHzAnt1 ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page23of48 OBWNVNTg2437MHzAnt1 OBWNVNTg2462MHzAnt1 ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page24of48 OBWNVNTn202412MHzAnt1 OBWNVNTn202437MHzAnt1 ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page25of48 OBWNVNTn202462MHzAnt1 ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page26of48 MaximumPowerSpectralDensityLevel ConditionModeFrequency (MHz) AntennaConducted PSD (dBm/3kHz) Duty Factor (dB) TotalPSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNTb2412Ant1-17.920.94-16.988Pass NVNTb2437Ant1-20.520.64-19.888Pass NVNTb2462Ant1-18.20.61-17.598Pass NVNTg2412Ant1-20.870.9-19.978Pass NVNTg2437Ant1-22.770.9-21.878Pass NVNTg2462Ant1-21.470.91-20.568Pass NVNTn202412Ant1-21.40.94-20.468Pass NVNTn202437Ant1-23.170.95-22.228Pass NVNTn202462Ant1-21.250.94-20.318Pass ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page27of48 PSDNVNTb2412MHzAnt1 PSDNVNTb2437MHzAnt1 ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page28of48 PSDNVNTb2462MHzAnt1 PSDNVNTg2412MHzAnt1 ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page29of48 PSDNVNTg2437MHzAnt1 PSDNVNTg2462MHzAnt1 ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page30of48 PSDNVNTn202412MHzAnt1 PSDNVNTn202437MHzAnt1 ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page31of48 PSDNVNTn202462MHzAnt1 ReportNo.:SZNTT26016349E1-1 SZNTT-TR728-0Page32of48 BandEdge ConditionModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict NVNTb2412Ant…

Text truncated - open the document above for the full version.

Test Report

ShenzhenNTTTestingTechnologyCo.,Ltd.ReportNo.:SZNTT26016349E1-1 TestReportTel:0755-27889935Web:http://www.ntt-testing.comPage1of31 TESTREPORT Applicant:KALADOLLC Address:3120139thAveSE,5thFloor,Bellevue,WA98005 Manufacturer: KALADOLLC Address:3120139thAveSE,5thFloor,Bellevue,WA98005 ProductName:IndoorCam ModelNumber: GC3,GC1,GC1Pro,GC2,GC2Pro,GC3,GC3Pro,GC4,GC4Pro,GC5,G C5Pro,GC6,GC7,GC8,GC9,GC10,GC11, M1,GM1,GM1Pro,GM2,GM2Pro,GM3,GM3Pro,GM4,GM4Pro,GM5, GM5Pro,GM6,GM7,GM8,GM9,GM10,GM11 Trademark:N/A FCCID:2A3PR-GC3 TestDate:Apr.14,2026–May08,2026 DateofReport: May08,2026 TestResult: ThisdevicedescribedabovehasbeentestedbyNTT,andthetest resultsshowthattheequipmentundertest(EUT)isincompliance withtheStandardrequirements.Anditisapplicableonlytothetested sampleidentifiedinthereport. TestProcedureUsed: Standards:FCCCFRTitle47Part15SubpartCSection15.247 ANSIC63.10-2020+Cor.1-2023 Preparedby(TestEngineer): ZhaoDi Reviewer(Supervisor): KenWu Approved(Manager): AbelYu ShenzhenNTTTestingTechnologyCo.,Ltd.ReportNo.:SZNTT26016349E1-1 TestReportTel:0755-27889935Web:http://www.ntt-testing.comPage2of31 TABLEOFCONTENT 1.GeneralInformation......................................................................................5 1.1.DescriptionofDevice(EUT).......................................................................................................................5 1.2.ChannelList..................................................................................................................................................5 1.3.Testconfiguration.........................................................................................................................................5 1.4.Summaryoftestresult................................................................................................................................6 1.5.SpecialAccessoriesandAuxiliaryEquipment........................................................................................6 1.6.Testmode......................................................................................................................................................6 1.7.BlockDiagram...............................................................................................................................................7 1.8.TestConditions.............................................................................................................................................7 1.9.MeasurementUncertainty(95%confidencelevels,k=2)......................................................................7 1.10.TestFacility..................................................................................................................................................8 1.11.TestEquipment...........................................................................................................................................8 2.Conductedemissionatthemainsterminalstest....................................10 2.1.Limit..............................................................................................................................................................10 2.2.TestSetup....................................................................................................................................................10 2.3.TestProcedure............................................................................................................................................10 2.4.TestResult...................................................................................................................................................11 3.RadiatedSpuriousEmissions...................................................................13 3.1.Limit..............................................................................................................................................................13 3.2.TestSetup....................................................................................................................................................14 3.3.TestProcedure............................................................................................................................................16 3.4.TestResult...................................................................................................................................................17 4.Dutycycle.....................................................................................................24 4.1.Limit..............................................................................................................................................................24 4.2.TestSetup....................................................................................................................................................24 4.3.TestProcedure............................................................................................................................................24 4.4.TestResult...................................................................................................................................................24 5.ConductedSpuriousEmissions................................................................25 5.1.Limit..............................................................................................................................................................25 5.2.TestSetup....................................................................................................................................................25 5.3.TestProcedure............................................................................................................................................25 5.4.TestResult...................................................................................................................................................25 6.BandEdgeMeasurement........................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Page1of2 FCCID:2A3PR-GC3 TestPhoto Page2of2

Contact Information

Applicant

Jack Tian
[email protected]Fax: 15625296304

Technical Contact

CELLT INC.Thompson Lim
[email protected]

1401 21ST ST # 12958 · SACRAMENTO, California, 95811 · United States

Test Firm

Shenzhen NTT Testing Technology Co., Ltd.Henry Wang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz17.95 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power. This device supports IEEE 802.11b/g/n but only includes a 20MHz signal bandwidth. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.