CEO 02/13/2026
Product General Description: Product is an automotive wireless charger intended to charge the mobile phone in the car wirelessly. The product is fitted in the instrument panel of car between the driver and passenger seat and more than 20cm away from the driver and passenger. (See below reference image) Operating Input voltage- 6V to 16V DC Max. input Current- 3A Max. Output Power- 15W Product Image Product Fitment details in Vehicle cockpit: Wireless charger
The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. FCC RF EXPOSURE CERTIFICATION TEST REPORT For CHARGER,WIRELESS MODEL NUMBER: W58Q0 REPORT NUMBER: 4792017615-RF-4 ISSUE DATE: December 3, 2025 FCC ID: 2A3PSW58Q0 Prepared for Uno Minda Ltd. B-64/1, Wazirpur Industrial Area, Delhi – 110052, INDIA Prepared by UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch Room 101, Building 2, No.4, Information Road, Songshan Lake, Dongguan, Guangdong, China Tel: +86 769 22038881 Fax: +86 769 33244054 Website: www.ul.com REPORT NO.: 4792017615-RF-4 Page 2 of 9 Page 2 of 9 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0019 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Revision History Rev. Issue Date Revisions Revised By V0 December 3, 2025 Initial Issue REPORT NO.: 4792017615-RF-4 Page 3 of 9 Page 3 of 9 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0019 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ........................................................................................................... 4 2. TEST METHODOLOGY ................................................................................................................................ 5 3. FACILITIES AND ACCREDITATION ........................................................................................................... 5 4. DESCRIPTION OF EUT ................................................................................................................................ 6 5. TEST MODE .................................................................................................................................................. 6 6. REQUIREMENT ............................................................................................................................................ 6 REPORT NO.: 4792017615-RF-4 Page 4 of 9 Page 4 of 9 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0019 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 1. ATTESTATION OF TEST RESULTS Applicant Information Company Name: Uno Minda Ltd. Address: B-64/1, Wazirpur Industrial Area, Delhi – 110052, INDIA Manufacturer Information Company Name: Uno Minda Ltd. (Controller Division) Address: First Floor, Gat No. 427/5, 427/10, Village Mahalunge Tal. Khed, Dist. Pune, Maharashtra –410501, INDIA. EUT Information EUT Name: CHARGER,WIRELESS Model: W58Q0 Brand: \ Sample Received Date: November 5, 2025 Sample Status: Normal Sample ID: 9091554-1 Date of Tested: November 5, 2025 to December 1, 2025 APPLICABLE STANDARDS STANDARD TEST RESULTS FCC 47 CFR §1.1307 PASS FCC 47 CFR §1.1310 PASS FCC 47 CFR §2.1093 PASS FCC 47 CFR §2.1091 PASS Prepared By: Checked By: James Qin Kebo Zhang Project Engineer Senior Project Engineer Approved By: Stephen Guo Operations Manager REPORT NO.: 4792017615-RF-4 Page 5 of 9 Page 5 of 9 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0019 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 2. TEST METHODOLOGY The tests documented in this report were performed in accordance with FCC 47 CFR§1.1307(b)(1), FCC 47 CFR §1.1310, FCC 47 CFR §2.1093, KDB 680106 D01 Wireless Power Transfer v04. 3. FACILITIES AND ACCREDITATION Accreditation Certificate A2LA (Certificate No.: 4102.01) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch has been assessed and proved to be in compliance with A2LA. FCC (FCC Designation No.: CN1187) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch has been recognized to perform compliance testing on equipment subject to the Commission's Delcaration of Conformity (DoC) and Certification rules ISED (Company No.: 21320) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch has been registered and fully described in a report filed with ISED. The Company Number is 21320 and the test lab Conformity Assessment Body Identifier (CABID) is CN0046. VCCI (Registration No.: C-20202, G-20240, R-20248 and T-20202) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch has been assessed and proved to be in compliance with VCCI, the membership No. is 3793. Facility Name: Chamber E, the VCCI registration No. is G-20240 and R-20248 Shielding Room F, the VCCI registration No. is C-20202 and T-20202 Note: 1. All measurement facilities that used to collect the measurement data are located at Room 101, Building 2, No. 4, Information Road, Songshan Lake, Dongguan, Guangdong, China. 2. The anechoic chamber in UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch had been calibrated and compared to the open field site (OFS), the anechoic chamber is proved to be equivalent to the worst case from the open field site (OFS). 3. Radiation measurements below 30 MHz have been performed in anechoic chamber, the measurement result is compared to the result that obtained on an open field site (OFS) and have been correlated to measurements result collected on an open field site (OFS). REPORT NO.: 4792017615-RF-4 Page 6 of 9 Page 6 of 9 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: …
Text truncated - open the document above for the full version.
CustomerφSE669 SPECIFICATION FOR APPROVAL Customer P/N Description Multi-coil Wireless Charging Drawing No. 3L P/N WPT1005504M-12R5K-A13P2 Date 20251025 Rev. XC Customer Approved For Customer Seller DrawnCheckedApproved PEIHUAHEPENGYUNSHU Please Return After Approving Headquarters: 3L ELECTRONIC (ZHONG SHAN) CORP. URL: http://www.3lcoil.com ADD: No 6 Industrial Park Nanlang Town Zhongshan Guangdong,P.R.China Customer P/N Description Multi-coil Wireless Charging Drawing No. 3L P/N WPT1005504M-12R5K-A13P2 Date 20251025 Rev. XC Customer Approved For Customer Seller DrawnCheckedApproved PEIHUAHEPENGYUNSHU Please Return After Approving Customer: SE669 Customer P/N: 3L P/N: WPT1005504M-12R5K-A13P2 Rev. XC Date: 20251025 Page2/ 8 RevisionDateRevision descriptionDesignApproved XA2025/02/25Initial release.BakerYUNSHU XB2025/06/28 Add QR labels,Change the size and operating temperature HEPENGYUNSHU XC2025/10/25Add materials listHEPENGYUNSHU XA2025/02/25Initial release.BakerYUNSHU XB2025/06/28 Add QR labels,Change the size and operating temperature HEPENGYUNSHU XC2025/10/25Add materials listHEPENGYUNSHU Customer: SE669 Customer P/N: 3L P/N: WPT1005504M-12R5K-A13P2 Rev. XC Date: 20251025 Page3/ 8 1. Mechanical Dimension(mm): ITEMSPEC (mm)TYP (mm)ITEMSPEC (mm)TYP (mm) A100.0+-1.099.8F3.2+-0.53.15 B55.0+-0.755.4G5.0+-0.3 C3.8 MAX3.62H46.5+-2.0 D8.0+-1.08.02I E1.35MAX1.16J Note: QR content⩤CDCCA001898Y 3L YYWW 1.Core peeling & breakage: Breakage is acceptable when it meets: length ≤ 5mm, width≤ 1mm, depth≤0.5mm. Every two breakages within 1mm interval would be regarded as one breakage and three breakages under this standard shall be acceptable on each product. 2. Crack on core: No more than two unobvious cracks which is less than 5mm long and 0.5mm wide are allowable to be on the core. Any crack or coating detachment affecting electromagnetic performance of core or mechanical strength is not acceptable. 3.Core fatness of product surface: The acceptable height difference of uneven surface shall be≤ 0.03mm. 4. Dislocation gap between every two cores connected: 1.The connection gap between every two cores shall be 0.5 mm MAX. 2.The dislocation gap between every two cores connected shall be 0.5mm MAX. ITEMSPEC (mm)TYP (mm)ITEMSPEC (mm)TYP (mm) A100.0+-1.099.8F3.2+-0.53.15 B55.0+-0.755.4G5.0+-0.3 C3.8MAX3.62H46.5+-2.0 D8.0+-1.08.02I E1.35MAX1.16J Note: QR content⩤CDCCA001898Y 3L YYWW 1.Core peeling & breakage: Breakage is acceptable when it meets: length≤ 5mm, width≤ 1mm, depth≤0.5mm. Every two breakages within 1mm interval would be regarded as one breakage and three breakages under this standard shall be acceptable on each product. 2.Crack on core: No more than two unobvious cracks which is less than 5mm long and 0.5mm wide are allowable to be on the core. Any crack or coating detachment affecting electromagnetic performance of core or mechanical strength is not acceptable. 3.Core fatness of productffsurface:The acceptable height difference of uneven surface shall be≤0.03mm. 4.Dislocation gap between every two cores connected: 1.Theconnection gap between every two cores shall be 0.5 mm MAX. Customer: SE669 Customer P/N: 3L P/N: WPT1005504M-12R5K-A13P2 Rev. XC Date: 20251025 Page4/ 8 5.Dislocation of PET film and double-sided adhesive tape: The PET film should not exceed outward the core more than 0.5mm and not be 1.5mm less than the core inward. 6.PET film cleaning: 1) No folding on the PET. 2) No more than 3 bubbles on single side of film while the area of single bubble shall not be more than 2mm. 7.Double- sided adhesive tape cleaning: 1) No folding on the tape. 2) No more than 3 bubbles on single side of tape while the area of single bubble shall not be more than 5mm. No breakage or hurt on tape. 8. The coil does not go beyond the edge of the CORE. 9. Size “G” Subject to the actual module confirmation (5.4 Module size) 10. Slight varnished wire exposure (0.5SQMM MAX) in silk-covered wire bending point during using is acceptable, which does not affect product function. 2. Coil unit Assembly Dimension 3. Coil unit Assembly: 6.PET film cleaning: 1) No folding on the PET. 2) No more than 3 bubbles on single side of film while the area of single bubble shall not be more than 2mm. 7.Double-sided adhesive tape cleaning: 1) No folding on the tape. 2) No more than 3 bubbles on single side of tape while the area of singlebubble shall not be more than 5mm. Nobreakage or hurt on tape. 8.The coil does not go beyond the edge of the CORE. 9.Size“G” Subject to the actual module confirmation (5.4 Module size) 10.Slight varnished wire exposure(0.5SQMMMAX)in silk-covered wire bending point during using is acceptable, which does not affect product function. 2.Coil unit Assembly Dimension 3.Coil unit Assembly: Customer: SE669 Customer P/N: 3L P/N: WPT1005504M-12R5K-A13P2 Rev. XC Date: 20251025 Page5/ 8 3.1 Coil spec: ŽŝůϭŽŝůϮ A45.2+-1.0 C19.5+-0.5 D1.25+-0.15 H52.0+-1.0 I27.5+-0.5 R4.0 A53.2+-1.0 C27.5+-0.5 D1.25+-0.15 H45.2+-1.0 I19.5+-0.5 R2.5 Žŝůϯ Žŝůϯ A45.2+-1.0 C19.5+-0.5 D1.25+-0.15 H52.0+-1.0 I27.5+-0.5 R4.0 ŽŝůϭŽŝůϮ A45.2+-1.0 C19.5+-0.5 D1.25+-0.15 H52.0+-1.0 I27.5+-0.5 R4.0 A53.2+-1.0 C27.5+-0.5 D1.25+-0.15 H45.2+-1.0 I19.5+-0.5 R2.5 Žŝůϯ Žŝůϯ A45.2+-1.0 C19.5+-0.5 D1.25+-0.15 H52.0+-1.0 I27.5+-0.5 R4.0 Customer: SE669 Customer P/N: 3L P/N: WPT1005504M-12R5K-A13P2 Rev. XC Date: 20251025 Page6/ 8 4.Electrical Characteristics(at 25ȭ/ RH 65% unless otherwise specified) : Test ItemSpecificationTest ConditionTest Instrument L1; L312.5uH±10%100KHz 1.0VHP4284A PRECISION LCR METER L211.5 uH±10%100KHz 1.0VHP4284A PRECISION LCR METER DCR1; DCR3 60 m¡MAX CHENHWA 502 OHM METER DCR2 60 m¡MAX CHENHWA 502 OHM METER L1; L3 TURNS12TS0.08X105P L2 TURNS12TS0.08X105P Ope.Temp -40 TO 105đ HC-D3M TEMP. & HUMIDITY CHAMBER 5. Material list: No.MaterialDescription 1CORE100/55/0.8MM XX95(Two pieces combined) 2WIRE 0.08X105P XUEW-F/HE UDTC /155đ 3GLUE6008TL 4EPOXYK9421L 5SOLDERSn99.9 6TAPE3M 9448A 7TAPE PETFP-50H 8G…
Text truncated - open the document above for the full version.
The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. FCC 47 CFR PART 15 SUBPART C CERTIFICATION TEST REPORT For CHARGER,WIRELESS MODEL NUMBER: W58Q0 REPORT NUMBER: 4792017615-RF-3 ISSUE DATE: December 3, 2025 FCC ID: 2A3PSW58Q0 Prepared for Uno Minda Ltd. B-64/1, Wazirpur Industrial Area, Delhi – 110052, INDIA Prepared by UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch Room 101, Building 2, No.4, Information Road, Songshan Lake, Dongguan, Guangdong, China Tel: +86 769 22038881 Fax: +86 769 33244054 Website: www.ul.com REPORT NO.: 4792017615-RF-3 Page 2 of 20 Page 2 of 20 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0053 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Revision History Rev. Issue Date Revisions Revised By V0 December 3, 2025 Initial Issue REPORT NO.: 4792017615-RF-3 Page 3 of 20 Page 3 of 20 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0053 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Summary of Test Results Description of Test Item Standard Results Radiated Emission Test FCC 15.209 PASS 20 dB Bandwidth FCC 15.215 PASS AC Power Line Conducted Emission FCC Part 15.207 N/A Note: 1. N/A = not applicable. 2. This test report is only published to and used by the applicant, and it is not for evidence purpose in China. 3. The measurement result for the sample received is <Pass> according to <FCC 47 CFR PART 15 SUBPART C> when <Simple Acceptance> decision rule is applied REPORT NO.: 4792017615-RF-3 Page 4 of 20 Page 4 of 20 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0053 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ........................................................................................................... 5 2. TEST METHODOLOGY ................................................................................................................................ 6 3. FACILITIES AND ACCREDITATION ........................................................................................................... 6 4. CALIBRATION AND UNCERTAINTY .......................................................................................................... 7 4.1. MEASURING INSTRUMENT CALIBRATION .................................................................................. 7 4.2. MEASUREMENT UNCERTAINTY ................................................................................................... 7 5. EQUIPMENT UNDER TEST ......................................................................................................................... 8 5.1. DESCRIPTION OF EUT .................................................................................................................. 8 5.2. TEST MODE .................................................................................................................................... 8 5.1. DESCRIPTION OF TEST SETUP ................................................................................................... 8 6. MEASURING INSTRUMENT LIST ............................................................................................................. 10 7. 20dB BANDWIDTH TEST .......................................................................................................................... 11 8. RADIATED EMISSION TEST ..................................................................................................................... 13 8.1. SPURIOUS EMISSIONS BELOW 30 MHz .................................................................................... 16 8.1.1. Test result ...................................................................................................................................... 16 8.2. SPURIOUS EMISSIONS 30 MHz ~ 1 GHz .................................................................................... 19 8.2.1. Test result ...................................................................................................................................... 19 REPORT NO.: 4792017615-RF-3 Page 5 of 20 Page 5 of 20 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0053 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 1. ATTESTATION OF TEST RESULTS Applicant Information Company Name: Uno Minda Ltd. Address: B-64/1, Wazirpur Industrial Area, Delhi – 110052, INDIA Manufacturer Information Company Name: Uno Minda Ltd. (Controller Division) Address: First Floor, Gat No. 427/5, 427/10, Village Mahalunge Tal. Khed, Dist. Pune, Maharashtra –410501, INDIA. EUT Information EUT Name: CHARGER,WIRELESS Model: W58Q0 Brand: \ Sample Received Date: November 5, 2025 Sample Status: Normal Sample ID: 9091554-1 Date of Tested: November 5, 2025 to December 1, 2025 Prepared By: Checked By: James Qin Kebo Zhang Project Engineer Senior Project Engineer Approved By: Stephen Guo Operations Manager APPLICABLE STANDARDS STANDARD TEST RESULTS FCC 47 CFR PART 15 SUBPART C PASS REPORT NO.: 4792017615-RF-3 Page 6 of 20 Page 6 of 20 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0053 This report shall not be reproduced …
Text truncated - open the document above for the full version.
5809 US-2, Suite B Albeni Plaza · Priest River, 83856 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.1277 MHz - 0.1277 MHz | - |