2A3RD-IPC6000Industrial personal computer

3onedata Co., Ltd.
Industrial personal computer - FCC ID 2A3RD-IPC6000 - 3onedata Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Feb 10, 2026
Application Purpose
Original Equipment
Equipment Note
Industrial personal computer
Frequency Range
2412.00000000 - 2462.00000000
Company
3onedata Co., Ltd.
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

3onedata Co., Ltd. Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 [January 5, 2026] U.S. Agent Designation [3onedata Co., Ltd.] acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought FCC ID: 2A3RD-IPC6000 Name and company of U.S. agent: [GLOCERTS TECHNOLOGY INC] Physical U.S. address of agent: [19784 SUNKISSED RIDGE DR, RIVERSIDE, CA 92507] FRN of U.S. agent: [0036339737] Email address of U.S. agent: [[email protected]] Telephone of U.S.agent: (626) 588-8039 [GLOCERTS TECHNOLOGY INC] acknowledges their obligation to accept service of process on behalf of [3onedata Co., Ltd.]. [3onedata Co., Ltd.] with the FRN [0031666183] accepts its obligation to maintain an agent for service of process in the United States for no less than 1 year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. Sincerely, Signature Signature [dehai LI] [Huiying Fan] [Test Engineer] [Director] [3onedata Co., Ltd.] [GLOCERTS TECHNOLOGY INC]

Attestation Statements

3onedata Co., Ltd. (December 31, 2025) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for FCC ID: 2A3RD-IPC6000 [3onedata Co., Ltd.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, the equipment does not utilize cyber-security or anti-virus software from Kaspersky Lab, Inc, or any of its successors and assignees, which is also on the “covered list”. Sincerely, (Applicant signature) (Applicant printed name) dehai LI 3onedata Co., Ltd. (December 31, 2025) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for FCC ID: 2A3RD-IPC6000 [3onedata Co., Ltd.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) dehai LI

Cover Letter(s)

3onedata Co., Ltd. Model Difference Data:December 31, 2025 Product description: Industrial personal computer Model name: IPC6000-2010-P, IPC2000, IPC5000, IPC6000, IPC7000, IVC2000, IVC5000, IVC6000, IVC7000 Trade Name: N/A FCC ID: 2A3RD-IPC6000 All the model are the same circuit and RF module, only for model name. Regards Sincerely Client’s signature : Client’s name / title : dehai LI(Test Engineer) Contact information / address:3/B, Zone 1, Baiwangxin High Technology Industrial park, Song Bai Road, Nanshan District, Shenzhen, 518108 China

Cover Letter(s)

3onedata Co., Ltd. (December 31, 2025) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (Industrial personal computer / IPC6000- 2010-P, IPC2000, IPC5000, IPC6000, IPC7000, IVC2000, IVC5000, IVC6000, IVC7000 / FCC ID: 2A3RD-IPC6000) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☒ Internal Photos ☐ NOTE 1 ☒ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No required to be submitted with this application be permanently withheld from public review. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely, Signature: Name: dehai LI Title: Test Engineer

Cover Letter(s)

3onedata Co., Ltd. (December 31, 2025) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize (Shenzhen CTB Testing Technology Co., Ltd.) to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Signature: Name: dehai LI Title: Test Engineer

External Photos

Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 4 Model: IPC6000-2010-P External Photos ANT Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 4 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 3 of 4 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 4 of 4

ID Label/Location Info

FCC ID LABEL: Label Location: FCC ID: 2A3RD-IPC6000 Model No.: IPC6000-2010-P

RF Exposure Info

FCC §15.247 (i), §2.1091 – RF Exposure FCC ID: 2A3RD-IPC6000 Applied procedures / limit According to FCC §15.247(i) and §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. Limits for Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm 2 ) Averaging Time |E| 2 ,|H| 2 or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842 / f 4.89 / f (900 / f)* 6 30-300 61.4 0.163 1.0 6 300-1500 F/300 6 1500-100,000 5 6 Note: ƒ is frequency in MHz * = Power density limit is applicable at frequencies greater than 100 MHz Limits for General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm 2 ) Averaging Time |E| 2 ,|H| 2 or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f)* 30 30-300 27.5 0.073 0.2 30 300-1500 F/1500 30 1500-100,000 1.0 30 Note: f = frequency in MHz * = Plane-wave equivalent power density MPE PREDICTION Predication of MPE limit at a given distance, Equation from OET Bulletin 65, Edition 97-01 Where: S = power density P = power input to antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna,R=20cm Test Result of RF Exposure Evaluation Modes& Channel Freq. (MHz) Tune up Produce power Maximu m peak output power (dBm) Output power to antenna (mW) Antenna Gain (numeric) Power Density (S) (mW/ cm2) Limit (mW / cm2 ) Result 2.4G WIFI 802.11n(H T40)&245 2 16±1 17 50.1187 1.6749 (2.24dBi) 0.0167 1 Pass

Test Report

SHENZHENBESCO.LTD 深圳市贝思科技有限公司 No.2BuildingofGuangdaIndustrialPark,No.2EnvironmentRoad,TianxinCommunity, Pingshan,Shenzhen,Guangdong,China Email:[email protected] 网站: https://antenna.en.made-in-china.com 承認書 APPROVALSHEET 客戶名稱: CUSTOMERNAME: 深圳市钡铼技术有限公司 物料編號: PARTNO: 產品品名: TYPENAME: WIFI吸盘天线 客戶料號: CUSTOMP/N: 規格: SPECIFICATON: SMA(ZJ)-WIFI吸盘天线-174线-3m 1.新品承認(NewlyApproved) 2.材料變更再承認(MaterialApproved) 3.規格變更再承認(SPECApproved) 製造廠商/供應廠商承認欄客戶承認欄 深圳市贝思科技有限公司 SHENZHENBESCO.LTD No.2BuildingofGuangdaIndustrialPark, No.2EnvironmentRoad,Tianxin Community,Pingshan,Shenzhen, Guangdong,China 承認章: (APPROVALBY): 承認章: (APPROVALBY): 承認日期: (APPROVALDATE):2025年月日 承認日期: (APPROVALDATE):2025年月日 供應商(SUPPLIER)客戶(CUSTOMER) 品質 Q.Dept 工程 E.Dept 業務 S.Dept 經辦 TESTED 審核 CHECKED 核准 APPROVED 黄晓闲王世海劉春玲 日期(DATE):2025年月日日期(DATE):2025年月日 SHENZHENBESCO.LTD 深圳市贝思科技有限公司 No.2BuildingofGuangdaIndustrialPark,No.2EnvironmentRoad,TianxinCommunity, Pingshan,Shenzhen,Guangdong,China Email:[email protected] 网站: https://antenna.en.made-in-china.com WIFI天线 一、产品规格ProductionParameter 二、天线性能参数Antennaperformanceparameters Size 尺寸 Ø29.5*143mmInstallation 安装方式 sticking 磁铁吸 Weight重量/ ConnectorType连接器 型号 SMA-C-J1.5 Housing 外壳颜色 Black 黑 Cable 电缆 RG-174-3m SHENZHENBESCO.LTD 深圳市贝思科技有限公司 No.2BuildingofGuangdaIndustrialPark,No.2EnvironmentRoad,TianxinCommunity, Pingshan,Shenzhen,Guangdong,China Email:[email protected] 网站: https://antenna.en.made-in-china.com FrequencyRange频率范围 -MHz 2400~2500MHz Inputimpedance输入阻抗-Ω50Ω VSWR电压驻波比≦2.0—— Gain增益-dBi≥3dBi Polarization极化方式Vertical垂直 MaximumPower最大功率-W10W WorkingTemp工作温度-40~+80°C storageTemp储存温度-45~+55°C Humidity湿度95%~100%R°C SHENZHENBESCO.LTD 深圳市贝思科技有限公司 No.2BuildingofGuangdaIndustrialPark,No.2EnvironmentRoad,TianxinCommunity, Pingshan,Shenzhen,Guangdong,China Email:[email protected] 网站: https://antenna.en.made-in-china.com 三、电缆线规格CableParameter RG174 结构参数Structureparameter 材料直径(mm) 1.内导体裸铜丝7/0.16 2.绝缘体实心聚乙烯(PE)1.50±0.05 3.外导体铜包铝(64编)64/0.12 4.护套黑色PVC2.80±0.1 电性能参数Electricperformanceparameters 电容(pF/m)101.05 阻抗(ohm)50 速率(%)66 弯曲半径(mm)10 最大工作电压(VMS)1500 最大工作频率(MHz)3000 工作温度范围(°C)-40至+85 编织丝单丝伸长率(%)≧10 成品线的拉力(N)≦140 成品线缆干扰信号遮蔽率(%) ≧95 衰减Attenuation 频率(MHz)衰减(≯dB/m) 1000.276 4000.558 10000.899 20001.530 30002.165 SHENZHENBESCO.LTD 深圳市贝思科技有限公司 No.2BuildingofGuangdaIndustrialPark,No.2EnvironmentRoad,TianxinCommunity, Pingshan,Shenzhen,Guangdong,China Email:[email protected] 网站: https://antenna.en.made-in-china.com 四、环境实验 产品名称4G吸盘天线 试验项目高温、低温、恒湿试验 检测设备恒温恒湿试验箱测试数量3 检验标准1.金属表面镀层无脱落、裂痕、起皱等不良;非金属部分不能有变色、裂痕、变 形、脱胶等现象。 试验名称试验项目要求试验方法结果判定 高温试验温度(°C) 试验温度时间(h) 试验持续时间(h) 恢复时间(h) 85±3 1 24 1 试验步骤: a)将被测件放入试验箱,再将 高温箱温度调到85°C±3°C,监 控时间。 b)试验后放置常温1小时,进 行常规检验。 合格 低温试验温度(°C) 试验温度时间(h) 试验持续时间(h) 恢复时间(h) -45±3 1 24 1 试验步骤: a)将被测件放入试验箱,再将 低温箱温度调到-45°C±3°C,监 控时间。 b)试验后放置常温1小时,进 行常规检验。 合格 恒定湿热 试验 温度(°C) 相对湿度(%) 试验持续时间(h) 恢复时间(h) +40±3 90-95 24 1 a)将被测件放入试验箱,再将 试验箱温度调到+40°C±3°C,湿 度为90-95%,监控时间。 b)试验后放置常温1小时,进 行常规检验。 合格 试验项目自由跌落测试 检测设备1米高桌面测试数量3 检验标准1.在1米高跌落,产品无脱落、裂痕、等不良,外观无变形等现象。 试验名称试验项目要求试验方法结果判定 自由跌落 测试 跌落高度1000mm正反面跌落2 次 试验步骤: a)将被测件在1000mm高度跌 落,试验后进行常规检验。 合格 试验项目验雾试验 检测设备验雾测试机测试数量3 检验标准1.金属表面镀层无脱落;外观无生锈、腐蚀、氧化等不良现象。 SHENZHENBESCO.LTD 深圳市贝思科技有限公司 No.2BuildingofGuangdaIndustrialPark,No.2EnvironmentRoad,TianxinCommunity, Pingshan,Shenzhen,Guangdong,China Email:[email protected] 网站: https://antenna.en.made-in-china.com 试验名称试验项目要求试验方法结果判定 盐雾试验 1.NaCl浓度: 2.空气压力: 3.PH值: 4.喷雾量: 5.盐水测试温度 设定 a.试验室温度: b.压力桶温度: 6.测试时间: 40-60g/1kg 1.0±0.01kgf㎡ 6.5-7.2 1.0-2.0ml/80c/h。 35±1°C 47±1°C 12H 试验步骤: a)将盐雾试验机,调 制到相关测试条件。 b)将被测件放入盐 雾试验机,放置24小 时。试验后用清水冲 洗,目测被测件外观, 进行常规检验。 合格 检验员:审核:批准: 五、产品实拍图 SHENZHENBESCO.LTD 深圳市贝思科技有限公司 No.2BuildingofGuangdaIndustrialPark,No.2EnvironmentRoad,TianxinCommunity, Pingshan,Shenzhen,Guangdong,China Email:[email protected] 网站: https://antenna.en.made-in-china.com 六、产品尺寸图 SHENZHENBESCO.LTD 深圳市贝思科技有限公司 No.2BuildingofGuangdaIndustrialPark,No.2EnvironmentRoad,TianxinCommunity, Pingshan,Shenzhen,Guangdong,China Email:[email protected] 网站: https://antenna.en.made-in-china.com SHENZHENBESCO.LTD 深圳市贝思科技有限公司 No.2BuildingofGuangdaIndustrialPark,No.2EnvironmentRoad,TianxinCommunity, Pingshan,Shenzhen,Guangdong,China Email:[email protected] 网站: https://antenna.en.made-in-china.com 七、包装图Packing 50PCS 200PCS 注:包装图只反映包装方式,具体以实物为准! SHENZHENBESCO.LTD 深圳市贝思科技有限公司 No.2BuildingofGuangdaIndustrialPark,No.2EnvironmentRoad,TianxinCommunity, Pingshan,Shenzhen,Guangdong,China Email:[email protected] 网站: https://antenna.en.made-in-china.com 测试数据TestData 测试图Testpattern SHENZHENBESCO.LTD 深圳市贝思科技有限公司 No.2BuildingofGuangdaIndustrialPark,No.2EnvironmentRoad,TianxinCommunity, Pingshan,Shenzhen,Guangdong,China Email:[email protected] 网站: https://antenna.en.made-in-china.com SHENZHENBESCO.LTD 深圳市贝思科技有限公司 No.2BuildingofGuangdaIndustrialPark,No.2EnvironmentRoad,TianxinCommunity, Pingshan,Shenzhen,Guangdong,China Email:[email protected] 网站: https://antenna.en.made-in-china.com SHENZHENBESCO.LTD 深圳市贝思科技有限公司 No.2BuildingofGuangdaIndustrialPark,No.2EnvironmentRoad,TianxinCommunity, Pingshan,Shenzhen,Guangdong,China Email:[email protected] 网站: https://antenna.en.made-in-china.com SHENZHENBESCO.LTD 深圳市贝思科技有限公司 No.2BuildingofGuangdaIndustrialPark,No.2EnvironmentRoad,TianxinCommunity, Pingshan,Shenzhen,Guangdong,China Email:[email protected] 网站: https://antenna.en.made-in-china.com

Test Report

Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 61 TEST REPORT Compiled by: Reviewed by: Approved by: Kai Chen Martin Feng Bin Mei / Director Note: If there is any objection to the inspection results in this report, please submit a written report to the company within 15 days from the date of receiving the report. The test report is effective only with both signature and specialized stamp. This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen CTB Testing Technology Co., Ltd. this report can’t be reproduced except in full. The tested sample(s) and the sample information are provided by the client. “*” indicates the testing items were fulfilled by subcontracted lab. “#” indicates the items are not in CNAS accreditation scope. Test item description: Industrial personal computer FCC ID: 2A3RD-IPC6000 Trademark(s): N/A Model/Type reference: IPC6000-2010-P, IPC2000, IPC5000, IPC6000, IPC7000, IVC2000, IVC5000, IVC6000, IVC7000 Applicant’s name: 3onedata Co., Ltd. Address: 3/B, Zone 1, Baiwangxin High Technology Industrial park, Song Bai Road, Nanshan District, Shenzhen, 518108 China Manufacturer: 3onedata Co., Ltd. Address: 3/B, Zone 1, Baiwangxin High Technology Industrial park, Song Bai Road, Nanshan District, Shenzhen, 518108 China Prepared By: Shenzhen CTB Testing Technology Co., Ltd. Address: 1&2/F., Building A, No.26, Xinhe Road, Xinqiao, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, China Sample Received Date: Nov. 18, 2025 Sample tested Date: Nov. 18, 2025 to Dec. 04, 2025 Issue Date: Dec. 04, 2025 Report No.: CTB25111815001RF01 Test Standards FCC CFR Title 47 Part 15 Subpart C Section 15.247 ANSI C63.10:2020 Test Results PASS Remark: This is WIFI-2.4GHz band radio test report. Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB25111815001RF01 Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 61 TABLE OF CONTENT Test Report Declaration Page 1. VERSION ........................................................................................................................................................ 4 2. TEST SUMMARY .......................................................................................................................................... 5 3. MEASUREMENT UNCERTAINTY............................................................................................................. 6 4. PRODUCT INFORMATION AND TEST SETUP ..................................................................................... 7 4.1 Product Information .................................................................................................................................................... 7 4.2 Test Setup Configuration .......................................................................................................................................... 7 4.3 Support Equipment ..................................................................................................................................................... 7 4.4 Channel List .................................................................................................................................................................. 8 4.5 Test Mode ...................................................................................................................................................................... 8 4.6 Test Environment ........................................................................................................................................................ 8 5. TEST FACILITY AND TEST INSTRUMENT USED ................................................................................ 9 5.1 Test Facility ................................................................................................................................................................... 9 5.2 Test Instrument Used ................................................................................................................................................. 9 6. AC POWER LINE CONDUCTED EMISSION .......................................................................................... 11 6.1 Block Diagram Of Test Setup ................................................................................................................................ 11 6.2 Limit ............................................................................................................................................................................... 11 6.3 Test procedure ........................................................................................................................................................... 11 6.4 Test Result .................................................................................................................................................................. 13 7. RADIATED SPURIOUS EMISSION ........................................................................................................ 14 7.1 Block Diagram Of Test Setup ................................................................................................................................ 14 7.2 Limit ............................................................................................................................................................................... 14 7.3 Test procedure ........................................................................................................................................................... 15 7.4 Test Result .................................................................................................................................................................. 16 8. BAND EDGE AND RF COUNDUCTED SPURIOUS EMISSIONS..................................................... 38 8.1 Block Diagram Of Test Setup ...................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 1 Model: IPC6000-2010-P Radiated Emission Below 1G Above 1G

Contact Information

Applicant

dehai LI
[email protected]Fax: +86-755-26703485

Technical Contact

GLOCERTS TECHNOLOGY INCHuiying Fan
[email protected]

19784 SUNKISSED RIDGE DR, · RIVERSIDE, California, 92507 · United States

Test Firm

Shenzhen CTB Testing Technology Co., Ltd.Rita Xiao
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz42.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The device supports 20MHz and 40MHz bandwidths. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter device.