FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Qingdao RONCO Mechanic Electronic Technology Co., Ltd./
  3. 2A3UMRE706-706W

2A3UMRE706-706WWireless emitter

Qingdao RONCO Mechanic Electronic Technology Co., Ltd.
Wireless emitter - FCC ID 2A3UMRE706-706W - Qingdao RONCO Mechanic Electronic Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jan 06, 2026
Application Purpose
Original Equipment
Equipment Note
Wireless emitter
Frequency Range
433.92000000 - 433.92000000
Company
Qingdao RONCO Mechanic Electronic Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Please read this Manual carefully before using the product and keep it properly for future reference 01 Product description Package containing: Emitter*1, Bracket*1, User Manual*1 Channel Wheel Channel - Channel + Stop Down Up Backside AAA battery X 2 PROG(S) P2 RE701/RE701W Single-Channel emitter RE702/RE702W 2 Channel emitter RE706/RE706W 6 Channel emitter RE715/RE715W 15 Channel emitter RE715R/RE715RW 15 Channel emitter with Wheel Product name: Wireless emitter Product model: RE701, RE702, RE706,RE715, RE715R RE701W,RE702W,RE706W,RE715W,RE715RW Product size: 144*37.5*15mm Input voltage: 3.0V Transmission distance: Exterior conditions>100m Interior conditions>35m Operating frequency: 433.92MHz Working temperature: -10°C~55°C Working humidity: 10%~90%RH, no condensing 02 Technical parameters 03 Features 1.RE706,RE706W,RE715, RE715R,RE715W,RE715RW: The displayed number is the chosen channel. 2.RE706,RE706W,RE715, RE715R,RE715W,RE715RW: LCD Version Channel Lock operation (example:if the emitter only needs 4 channels, then lock the 4th channel, the emitter will be able to use channels from 0 to 4): Switch the screen number to 4th channel, press + and - simultaneously to let the number on the screen flashes 3 times, then release to finish the setting. Repeating this operation is for canceling the Channel Lock function. 3.RE706,RE706W,RE715, RE715R,RE715W,RE715RW: 0 channel is group control of all paired motors. 4.RE715R,RE715RW Wheel: Short rolling the wheel, the motor rotates inchingly. Fast rolling 3 times enter % control, screen shows 50% then roll the wheel to adjust %, motor will rotate accordingly after % confirmed. 04 Operation steps KeystrokeTime Long press 2s Long press 2s Long press 2s Long press 2s Short rolling Fast rolling 3 times 1 time Description Feature settings Switch direction/ setting confirmation Speed + Speed - Tilting move Enter % control mode Pairing Remarks: Please follow up with motor User manual. 1. To prevent shortening the emitter's service life, avoid exposing the device to moisture or physical impacts during use. If you notice reduced effective range or decreased sensitivity, replace the battery with the same model type and ensure proper environmentally friendly recycling of used batteries. 2. Never use unauthorized replacement with different battery types, as this may create explosion hazards. 05 Warnings and Precautions 06 Warranty coverage Type Entire deviceWireless emitter2 years Warranty coverageWarranty Indicates that the concentration of the hazardous substance in all homogeneous materials of this component is below the threshold limits specified in GB/T 26572. Indicates that the hazardous substance exceeds the threshold limits specified in GB/T 26572 in at least one homogeneous material of this component. 07 Hazardous Substances and Concentrations in the Product Part PbHgCdCr(VI)PBDE Hazardous Substances Enclosure PCB parts This table is prepared in accordance with SJ/T 11364 : : 08 FCC Statement Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2)This device must accept any interference received, including interference that may cause undesired operation. Note : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates,uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment . 09 ISED Statement This device complies with Innovation, Science and Economic Development Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction. Le présent appareil est conforme aux CNR d'ISED applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. L'appareil a été évalué comme répondant aux exigences générales d'exposition aux radiofréquences. L'appareil peut être utilisé dans des conditions d'exposition portable sans restriction.

Attestation Statements

Company: Qingdao RONCO Mechanic Electronic Technology Co., Ltd. Add: No.43 Yanqing Rd, Huanxiu Sub-District, Jimo District,Qingdao, Shandong, China Tel: +86-532-88595298 Fax: +86-532-88595298 E-mail: [email protected] DECLARATION Date: 2025-12-01 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 We, Qingdao RONCO Mechanic Electronic Technology Co., Ltd. hereby declare that product name: Wireless emitter (FCC ID: 2A3UMRE706-706W; model name: RE706, RE706W) are electrically identical with the PCB design, components and electromagnetic compatibility characteristics, and model: RE706W has been tested by Bay Area Compliance Laboratories Corp. (Kunshan). The differences of them are as follows: The bottom cover, rear cover and bracket of RE706 are black, while RE706W is white. Please contact me if there is need for any additional c larification or information. Best Regards, Signature: Printed Name: Cunlei Cui Title: Quality Manager

Attestation Statements

Company: Qingdao RONCO Mechanic Electronic Technology Co., Ltd. Add: No.43 Yanqing Rd, Huanxiu Sub-District, Jimo District, Qingdao, Shandong, China Tel: +86-532-88595298 Fax: +86-532-88595298 E-mail: [email protected] Attestation Letter Date: 12/01/2025 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911 (d) (5) (i) (ii) Filing FCC ID: 2A3UMRE706-706W Qingdao RONCO Mechanic Electronic Te chnology Co., Ltd. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Qingdao RONCO Mechanic Electronic Technology Co., Ltd. (“the applicant”) certifies that as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Qingdao RONCO Mechanic Electronic Technology Co., Ltd. (“the applicant”) certifies that the equipment does not use Kaspersky's software information. Sincerely, Signature: Contact Person: Cunlei Cui Title: Quality Manager

Attestation Statements

U.S. AGENT LETTER OF ATTESTATION Date: 2025-12-01 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(7) Filing FCC ID: 2A3UMRE706-706 W Qingdao RONCO Mechanic Electronic Technology Co., Ltd. (“the Applicant”) certifies that, as of the date of the filing of the application, Iconsigh is our designated U.S. agent for service of process for the above referenced FCC ID. Qingdao RONCO Mechanic Electronic Technology Co., Ltd. (“the Applicant”) accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Iconsigh accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Company Name: Iconsigh Address: 2310 Homestead Road, Suite C1, Los Altos, CA 94024, USA FRN: 0033398652 Tel.: +1 (408) 320-9867 Email: [email protected] Signed by (printed name): Benjamin Kaur Signature: Applicant: Qingdao RONCO Mechanic Electronic Technology Co., Ltd. Address: No.43 Yanqing Rd, Huanxiu Sub-District, Jimo District, Qingdao, Shandong, China FRN: 0031694805 Tel: +86-532-88595298 Email: [email protected] Signed by (printed name): Cunlei Cui Signature:

Cover Letter(s)

QA-FR-170-B Company: Qingdao RONCO Mechanic Electronic Technology Co., Ltd. Add: No.43 Yanqing Rd, Huanxiu Sub-District, Jimo District, Qingdao, Shandong, China Tel: +86-532-88595298 Fax: +86-532-88595298 E-mail: [email protected] FCC Authorization Date: 2025-12-01 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We, Qingdao RONCO Mechanic Electronic Technology Co., Ltd., hereby authorizes Bay Area Compliance Laboratories Corp. ( Kunshan) to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratories Corp. (Kunshan) on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely, Signature: Print Name: Cunlei Cui Title: Quality Manager

Cover Letter(s)

QA-FR-171-A Company: Qingdao RONCO Mechanic Electronic Technology Co., Ltd. Add.: No.43 Yanqing Rd, Huanxiu Sub-District, Jimo District, Qingdao, Shandong, China Tel: +86-532-88595298 Fax: +86-532-88595298 E-mail: [email protected] FCC Confidential Authorization Date: 2025-12 -01 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: 2A3UMRE706-706W In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Qingdao RONCO Mechanic Electronic Technology Co., Ltd. hereby requests long-term confidential treatment of information accompanying this application as outlined below: ď‚·Block Diagram ď‚·Schematics ď‚·Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely, Signature: Printer Name: Cunlei Cui Title: Quality Manager

External Photos

Bay Area Compliance Laboratories Corp. (Kunshan) Project No.: RQDA251201002 1 / 6 EXHIBIT A - EUT EXTERNAL PHOTOGRAPHS Model: RE706W Bay Area Compliance Laboratories Corp. (Kunshan) Project No.: RQDA251201002 2 / 6 Bay Area Compliance Laboratories Corp. (Kunshan) Project No.: RQDA251201002 3 / 6 Bay Area Compliance Laboratories Corp. (Kunshan) Project No.: RQDA251201002 4 / 6 Model: RE706 Bay Area Compliance Laboratories Corp. (Kunshan) Project No.: RQDA251201002 5 / 6 Bay Area Compliance Laboratories Corp. (Kunshan) Project No.: RQDA251201002 6 / 6

ID Label/Location Info

2 32 30

Internal Photos

Bay Area Compliance Laboratories Corp. (Kunshan) Project No.: RQDA251201002 1 / 4 EXHIBIT B - EUT INTERNAL PHOTOGRAPHS Model: RE706W Bay Area Compliance Laboratories Corp. (Kunshan) Project No.: RQDA251201002 2 / 4 Antenna Bay Area Compliance Laboratories Corp. (Kunshan) Project No.: RQDA251201002 3 / 4 Model: RE706 Bay Area Compliance Laboratories Corp. (Kunshan) Project No.: RQDA251201002 4 / 4 Antenna

RF Exposure Info

Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RQDA251201002-00B Page 17 of 26 RF EXPOSURE EVALUATION Applicable Standard §1.1307(b)(3)(i) For single RF sources (i.e., any single fixed RF source, mobile device, or portable device, as defined in paragraph (b)(2) of this section): A single RF source is exempt if: (A) The available maximum time-averaged power is no more than 1 mW, regardless of separation distance. This exemption may not be used in conjunction with other exemption criteria other than those in paragraph (b)(3)(ii)(A) of this section. Medical implant devices may only use this exemption and that in paragraph (b)(3)(ii)(A). Frequency (MHz) Maximum EIRP (dBm) Maximum EIRP 1-mW Test Exemption mW 433.92 -14.8 0.03 Compliant Note: 1. Chose the maximum power to do RF exposure evaluation analysis. 2. This device maximum E-Field level is 80.40 dBμV/m at 3m, so the EIRP power is -14.8 dBm. 3. Pout EIRP (dBm) = Field Strength of Fundamental (dBμV/m)-95.2 for d=3m. Result: Compliant. RF Exposure is exemption.

Test Report

Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Kunshan). This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, or any agency of the U.S.Government. FCC PART 15.231 TEST REPORT For Qingdao RONCO Mechanic Electronic Technology Co., Ltd. No.43 Yanqing Rd, Huanxiu Sub-District, Jimo District, Qingdao, Shandong, China FCC ID: 2A3UMRE706-706W Report Type: Original Report Product Name: Wireless emitter Report Number: RQDA251201002-00B Report Date: 2025-12-19 Reviewed By: Winnie Yang Approved By: Kyle Xu Test Laboratory: Bay Area Compliance Laboratories Corp. (Kunshan) No.248 Chenghu Road, Kunshan, Jiangsu province, China Tel: +86-512-86175000 Fax: +86-512-88934268 www.baclcorp.com.cn Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RQDA251201002-00B Page 2 of 26 TABLE OF CONTENTS REPORT REVISION HISTORY................................................................................................................................. 3 GENERAL INFORMATION ....................................................................................................................................... 4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 4 OBJECTIVE ................................................................................................................................................................... 4 TEST METHODOLOGY .................................................................................................................................................. 5 MEASUREMENT UNCERTAINTY .................................................................................................................................... 5 TEST FACILITY ............................................................................................................................................................. 5 SYSTEM TEST CONFIGURATION .......................................................................................................................... 6 JUSTIFICATION ............................................................................................................................................................. 6 EUT EXERCISE SOFTWARE .......................................................................................................................................... 6 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 6 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 6 EXTERNAL I/O CABLE.................................................................................................................................................. 6 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................ 7 SUMMARY OF TEST RESULTS ............................................................................................................................... 8 TEST EQUIPMENT LIST ........................................................................................................................................... 9 FCC§15.203 - ANTENNA REQUIREMENT............................................................................................................ 10 APPLICABLE STANDARD ............................................................................................................................................ 10 ANTENNA CONNECTED CONSTRUCTION .................................................................................................................... 10 FCC §15.205, §15.209, §15.231 (B) - RADIATED EMISSIONS ............................................................................. 11 APPLICABLE STANDARD ............................................................................................................................................ 11 TEST SYSTEM SETUP .................................................................................................................................................. 12 EMI TEST RECEIVER SETUP ....................................................................................................................................... 14 TEST PROCEDURE ...................................................................................................................................................... 14 TEST RESULTS SUMMARY .......................................................................................................................................... 14 TEST DATA: SEE APPENDIX ....................................................................................................................................... 14 FCC §15.231(A) (2) - DEACTIVATION TESTING................................................................................................. 15 APPLICABLE STANDARD ............................................................................................................................................ 15 TEST SYSTEM SETUP .................................................................................................................................................. 15 TEST PROCEDURE ...................................................................................................................................................... 15 TEST DATA: SEE APPENDIX ....................................................................................................................................... 15 FCC §15.231(…

Text truncated - open the document above for the full version.

Test Setup Photos

Bay Area Compliance Laboratories Corp. (Kunshan) Project No.: RQDA251201002 1 / 2 EXHIBIT C - TEST SETUP PHOTOGRAPHS Radiated Emissions (Below 30 MHz) Radiated Emissions (Below 1 GHz) Bay Area Compliance Laboratories Corp. (Kunshan) Project No.: RQDA251201002 2 / 2 Radiated Emissions (Above 1 GHz)

Contact Information

Applicant

Cunlei Cui(Quality Manager)
[email protected]Fax: +86 0532-88595298

Technical Contact

Iconsigh Inc.Benjamin Kaur
[email protected]

2310 Homestead Road, Suite C1 · Los Altos, California, 94024 · United States

Test Firm

Bay Area Compliance Laboratories Corp. (Kunshan)John Chan
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term