Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
CERAGEM CO., LTD. 2026. 08. 12 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID# 2A3VY-GMESK2601) [CERAGEM CO., LTD.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, the equipment does not utilize cyber-security or anti-virus software from Kaspersky Lab, Inc, or any of its successors and assignees, which is also on the “covered list”. Sincerely, SEO YOON PARK CERAGEM CO., LTD. 2026. 08. 12 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCC ID#2A3VY-GMESK2601) [CERAGEM CO., LTD.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, SEO YOON PARK
iCertifi Control Number - IC2026ASOP12523 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 06/08/2026 Ref: Attestation Statement Part 2.911(d)(7) Filing FCC ID: 2A3VY-CGMESK2601 CERAGEM CO., LTD. certifies that, as of the dates of this application, Americas Compliance Consulting LLC dba iCertifi is our designated U.S. agent for service of process for the above referenced FCC ID. Manufacturer accepts to maintain an agent for no less than two year after the grantee has terminated all marketing and importation or the conclusion of any commission-related proceeding involving the equipment. iCertifi accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service process for the above referenced FCC ID. Designated U.S. Agent Information: Name: Americas Compliance Consulting LLC dba iCertifi FCC FRN: 0033399411 Address: 5809 US-2, Suite B, Albeni Plaza Priest River, Idaho 83856, United States Contact Person: Paul Preston Tel: +1 (866) 885-4575 Email: [email protected] Sincerely, CERAGEM CO., LTD.Americas Compliance Consulting LLC dba iCertifi FRN: 0031717952FRN: 0033399411 SEO-YOON PARKPaul Preston [email protected]@icertifi.com 82-41-529-4359+1 (866) 885-4575 Signature: Signature:
CERAGEM CO., LTD. 10, Jeongja 1-gil, Seonggeo-eup, Seobuk-gu, Cheonan-si, Chungcheongnam-do, Republic of Korea Date: Aug 12, 2026 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (CELLUNIC Medispa All in One/CGM ESK-2601 # FCC ID: 2A3VY-CGMESK2601) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the (below list) required to be submitted with this application be permanently withheld from public review. Permanent Confidential Request -. Schematics -. Block Diagram -. Operational Description -. Part list -. U-NII Device SW Security Statement SPECIFY REASON FOR REQUEST (i.e. the above documents are company proprietary information that could never get into the possession of your competition). Please contact me if there is any information you may need. Sincerely, SEO-YOON PARK/ MANAGER
CERAGEM CO., LTD. 10, Jeongja 1-gil, Seonggeo-eup, Seobuk-gu, Cheonan-si, Chungcheongnam-do, Republic of Korea Date: Aug 12, 2026 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (CELLUNIC Medispa All in One/CGM ESK-2601 # FCC ID: 2A3VY-CGMESK2601) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the (below list) required to be submitted with this application be short-term Confidentiality f or a period of 180 days after grant is issued. Short-Term Confidential Request -. External Photos -. Internal Photos -. Test set-up photo -. User Manual SPECIFY REASON FOR REQUEST (i.e. These documents contain detailed system and equipment descriptions and related information about the product, which we considers to be proprietary, confidential, and a custom design and otherwise, would not release to the general public. Since this design is a basis from which future technological products will evolve, we feel that this information would be of benefit to our competitors, and that the disclosure of the information in these documents would give our competitors an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely, SEO-YOON PARK / MANAGER
CERAGEM CO., LTD. 10, Jeongja 1-gil, Seonggeo-eup, Seobuk-gu, Cheonan-si, Chungcheongnam-do, Republic of Korea Date: Aug 12, 2026 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Ms. Jeeun Mun/Assistant Manager of Eurofins KCTL Co.,Ltd. to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Sincerely, SEO YOON PARK /MANAGER
verify No.858725756278 Eurofins KCTL Co.,Ltd. 65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16677, Korea TEL: 82-70-4904-0113 FAX: 82-505-299-8311 www.kctl.co.kr Report No.: KR26-SRF0151 Page (2) of (8) KCTL-TIR001-003/7 (220705) KP25-08158 REPORT REVISION HISTORY Date Revision Page No 2026-08-26 Originally issued - This report shall not be reproduced except in full, without the written approval of Eurofins KCTL Co.,Ltd. This document may be altered or revised by Eurofins KCTL Co.,Ltd. personnel only, and shall be noted in the revision section of the document. Any alteration of this document not carried out by Eurofins KCTL Co.,Ltd. will constitute fraud and shall nullify the document. This test report is a general report that does not use the KOLAS accreditation mark and is not related to KS Q ISO/IEC 17025 and KOLAS accreditation. General remarks for test reports Statement concerning the uncertainty of the measurement systems used for the tests (may be required by the product standard or client) Internal procedure used for type testing through which traceability of the measuring uncertainty has been established: Procedure number, issue date and title: Calculations leading to the reported values are on file with the testing laboratory that conducted the testing. Statement not required by the standard or client used for type testing Eurofins KCTL Co.,Ltd. 65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16677, Korea TEL: 82-70-4904-0113 FAX: 82-505-299-8311 www.kctl.co.kr Report No.: KR26-SRF0151 Page (3) of (8) KCTL-TIR001-003/7 (220705) KP25-08158 CONTENTS 1. General information ......................................................................................................4 2. Device information ........................................................................................................4 2.1. Frequency/channel operations................................................................................5 3. Measurement uncertainty .............................................................................................5 4. RF Exposure .................................................................................................................6 4.1. Test results..............................................................................................................8 Eurofins KCTL Co.,Ltd. 65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16677, Korea TEL: 82-70-4904-0113 FAX: 82-505-299-8311 www.kctl.co.kr Report No.: KR26-SRF0151 Page (4) of (8) KCTL-TIR001-003/7 (220705) KP25-08158 1. General information Client : CERAGEM CO., LTD. Address : 10, Jeongja 1-gil, Seonggeo-eup, Seobuk-gu, Cheonan-si, Chungcheongnam-do, Republic of Korea Manufacturer : BTB Korea Co., Ltd Address : 7, Dongwon-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, Republic of Korea Laboratory : Eurofins KCTL Co.,Ltd. Address : 65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16677, Korea Accreditations : FCC Site Designation No: KR0040, FCC Site Registration No: 687132 VCCI Registration No. : R-20080, G-20078, C-20059, T-20056 CAB Identifier: KR0040 ISED Number: 8035A KOLAS No.: KT231 2. Device information Equipment under test : CELLUNIC Medispa All in One Model : CGM ESK-2601 Modulation technique : WLAN(802.11b/g/n/a/ac/ax)_DSSS, OFDM, OFDMA Number of channels : 2.4 ㎓ band : 13 ch (20 ㎒), 11 ch (40 ㎒) 5 ㎓ band UNII-1 : 4 ch (20 ㎒), 2 ch (40 ㎒) UNII-3 : 5 ch (20 ㎒), 2 ch (40 ㎒) Power source : DC 11.1 V (Battery) Antenna type : FPCB Antenna Antenna gain : 2.4 ㎓ band : 3.06 ㏈i 5 ㎓ band UNII-1 : 2.10 ㏈i UNII-3 : 2.84 ㏈i Frequency range : 2.4 ㎓ band : 2 412 ㎒ ~ 2 472 ㎒ (802.11b/g/n/ax_HT20/HE20) 2 422 ㎒ ~ 2 462 ㎒ (802.11n/ax_HT40/HE40) 5 ㎓ band UNII 1 : 5 180 ㎒ ~ 5 240 ㎒ (802.11a/n/ac/ax_HT20/VHT20/HE20) 5 190 ㎒ ~ 5 230 ㎒ (802.11n/ac/ax_HT40/VHT40/HE40) UNII 3 : 5 745 ㎒ ~ 5 825 ㎒ (802.11a/n/ac/ax_HT20/VHT20/HE20) 5 755 ㎒ ~ 5 795 ㎒ (802.11n/ac/ax_HT40/VHT40/HE40) Software version : V1.1.10 Hardware version : V1.0 Test device serial No. : MACG0KO60500003 Operation temperature : -20 °C ~ 50 °C Eurofins KCTL Co.,Ltd. 65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16677, Korea TEL: 82-70-4904-0113 FAX: 82-505-299-8311 www.kctl.co.kr Report No.: KR26-SRF0151 Page (5) of (8) KCTL-TIR001-003/7 (220705) KP25-08158 2.1. Frequency/channel operations This device contains the following capabilities: WLAN 2.4 ㎓_802.11b/g/n(HT20/40)/ax(HE20/40), WLAN 5 ㎓_802.11a/n(HT20/40)/ac(VHT20/40)/ax(HE20/40) Ch. Frequency ( ㎒ ) 01 2 412 . . . . 06 2 437 . . . . 11 2 462 12 2 467 13 2 472 Ch. Frequency ( ㎒ ) 03 2 422 . . . . 06 2 437 . . . . 09 2 452 10 2 457 11 2 462 Table 2.1.1. 802.11b/g/n/ax_HT20/HE20 Table 2.1.2. 802.11n/ax_HT40/HE40 UNII-1 UNII-3 Ch. Frequency ( ㎒ ) 36 5 180 40 5 200 48 5 240 Ch. Frequency ( ㎒ ) 149 5 745 157 5 785 165 5 825 Table 2.1.3. 802.11a/n/ac/ax HT20/VHT20/HE20 UNII-1 UNII-3 Ch. Frequency ( ㎒ ) 38 5 190 46 5 230 Ch. Frequency ( ㎒ ) 151 5 755 159 5 795 Table 2.1.4. 802.11a/n/ac/ax HT40/VHT40/HE40 3. Measurement uncertainty The measurement uncertainties shown below were calculated in accordance with the requirements of ANSI C63.4-2014+C63.4a-2017. All measurement uncertainty values are shown with a coverage factor of k=2 to indicated a 95 % level of confidence. The measurement data shown herein meets of exceeds the U CISPR measurement uncertainty values specified in CISPR 16-4-2 and thus, can be compared directly to specified limits to determine compliance. Parameter Expanded uncertainty ( ± ) Conducted RF power 0.9 ㏈ Eurofins KCTL Co.,Ltd. 65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16677, Korea TEL: 82-70-4904-0113 FAX: 82-505-299-8311 www.kctl.co.kr Report No.: KR26-SRF0151 Page (6) of (8) KCTL-TIR001-003/7 (220705) KP25-08158 4. RF Exposure FCC Regulation This document is prepared to show compliance with the RF Exposure requirements as required in §1.1310 of the FCC rules and Regulations. The limit for Maximum Permissible Exposure (MPE), specified in FCC §1.1310, is…
Text truncated - open the document above for the full version.
深圳市亿圣邦科技有限公司 第 1 页 深圳市亿圣邦科技有限公司 样 品 承 认 书 SPECIFICATION FOR APPROVAL 公 司 名 称(客户填写): 深圳市亿莱顿科技有限公司 物 料 代 码(客户填写): 规 格 型 号(客户填写): Y5016T 承 认 日 期(客户填写): 供 应 商 名 称(SLK填写):深圳市亿圣邦科技有限公司 供 应 商 规 格 型 号(SLK填写):WIFI:SLK-YLD-4312-R-170I-B 供应商名称:深圳市亿圣邦科技有限公司 供应商地址:深圳市宝安区深圳前湾硬科技产业园C栋101 电 话:18025305599 电 话:18666299104 承 认 签 章 供 应 商 承 认(SLK填写栏) 深圳市亿莱顿科技有限公司 工 程 师 品质 结构 工 程 师 审 核 批 准 刘顺 陈揭兴 刘才亮 批准 林美财 盖章签署 日 期 2025-4-8 日 期 批示: □接受 □有条件接受 备注(客户填写): 深圳市亿圣邦科技有限公司 第 2 页 WIFI 1 Antenna (4312) 1.Explanation of Product number : S L K-Y L D-4312-R-170I-B 1 2 3 4 5 Product Code: (1) Customer: YLD:亿莱顿 (2) Project: 4312:SLK-4312 (WIFI antenna) (3) Welding Position R:Right (4) Cable Length: 170I: 170*1.13MM一代端子 (5)Cable Color B:Black 2. Features *Stable and reliable in performances *Compact size *RoHS compliance 3. Applications * IEEE802.11 (a/b/g/n) * Hand-held devices when WIFI (802.11a/b/g/n) functions are needed 深圳市亿圣邦科技有限公司 第 3 页 4. Description Holy bond’s FPC antenna series are specially designed for WIFI (802.11a/b/g/n) applications. Based on Holy bond’s proprietary design and processes, this FPC antenna has excellent stability and sensitivity to consistently provide high signal reception efficiency. 5. Electrical Specifications 5-1 Characteristics Specifications Unit Outline Dimensions 42.99x11.61x0.12 mm Center Frequency 2400-2500 5170-5850 MHz Bandwidth(under-10dB return loss) 130min MHz VSWR 3max 5.2 VSWR S11 深圳市亿圣邦科技有限公司 第 4 页 5-3.WIFI 1 Antenna Gain/Efficiency/Radiation Pattern of 3D 深圳市亿圣邦科技有限公司 第 5 页 6. Antenna Dimensions (unit: mm) 深圳市亿圣邦科技有限公司 第 6 页 7. Antenna Picture
verify No.538098793049 Eurofins KCTL Co.,Ltd. 65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16677, Korea TEL: 82-70-4904-0113 FAX: 82-505-299-8311 www.kctl.co.kr Report No.: KR26-SRF0150 Page (2) of (85) KCTL-TIR001-003/7 (220705) KP25-08158 REPORT REVISION HISTORY Date Revision Page No 2026-08-26 Originally issued - This report shall not be reproduced except in full, without the written approval of Eurofins KCTL Co.,Ltd. This document may be altered or revised by Eurofins KCTL Co.,Ltd. personnel only, and shall be noted in the revision section of the document. Any alteration of this document not carried out by Eurofins KCTL Co.,Ltd. will constitute fraud and shall nullify the document. This test report is a general report that does not use the KOLAS accreditation mark and is not related to KS Q ISO/IEC 17025 and KOLAS accreditation. General remarks for test reports Statement concerning the uncertainty of the measurement systems used for the tests (may be required by the product standard or client) Internal procedure used for type testing through which traceability of the measuring uncertainty has been established: Procedure number, issue date and title: Calculations leading to the reported values are on file with the testing laboratory that conducted the testing. Statement not required by the standard or client used for type testing Eurofins KCTL Co.,Ltd. 65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16677, Korea TEL: 82-70-4904-0113 FAX: 82-505-299-8311 www.kctl.co.kr Report No.: KR26-SRF0150 Page (3) of (85) KCTL-TIR001-003/7 (220705) KP25-08158 CONTENTS 1. General information ......................................................................................................4 2. Device information ........................................................................................................4 2.1. Frequency/channel operations................................................................................5 2.2. RF power setting in TEST SW ................................................................................6 2.3. Duty Cycle Factor ...................................................................................................7 3. Antenna requirement ....................................................................................................9 4. Summary of tests ........................................................................................................ 10 5. Measurement uncertainty ........................................................................................... 11 6. Measurement results explanation example ................................................................ 12 7. Test results ................................................................................................................. 13 7.1. Maximum conducted output power ....................................................................... 13 7.2. Maximum Power Spectral Density ........................................................................ 18 7.3. 26 ㏈ Bandwidth & 99% Bandwidth ..................................................................... 24 7.4. 6 ㏈ Bandwidth & 99% Bandwidth ....................................................................... 28 7.5. Frequency stability ................................................................................................ 32 7.6. Spurious Emission, Band Edge and Restricted bands .......................................... 35 7.7. AC Conducted emission ....................................................................................... 82 8. Measurement equipment ............................................................................................ 85 Eurofins KCTL Co.,Ltd. 65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16677, Korea TEL: 82-70-4904-0113 FAX: 82-505-299-8311 www.kctl.co.kr Report No.: KR26-SRF0150 Page (4) of (85) KCTL-TIR001-003/7 (220705) KP25-08158 1. General information Client : CERAGEM CO., LTD. Address : 10, Jeongja 1-gil, Seonggeo-eup, Seobuk-gu, Cheonan-si, Chungcheongnam-do, Republic of Korea Manufacturer : BTB Korea Co., Ltd Address : 7, Dongwon-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, Republic of Korea Laboratory : Eurofins KCTL Co.,Ltd. Address : 65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16677, Korea Accreditations : FCC Site Designation No: KR0040, FCC Site Registration No: 687132 VCCI Registration No. : R-20080, G-20078, C-20059, T-20056 CAB Identifier: KR0040 ISED Number: 8035A KOLAS No.: KT231 2. Device information Equipment under test : CELLUNIC Medispa All in One Model : CGM ESK-2601 Modulation technique : WIFI(802.11a/n/ac/ax) : OFDM, OFDMA Number of channels : UNII 1 : 4 ch (20 ㎒), 2 ch (40 ㎒) UNII 3 : 5 ch (20 ㎒), 2 ch (40 ㎒) Power source : DC 11.1 V (Battery) Antenna specification : FPCB Antenna Antenna gain : UNII 1 : 2.10 ㏈i UNII 3 : 2.84 ㏈i Frequency range UNII 1 : 5 180 ㎒ ~ 5 240 ㎒ (802.11a/n/ac/ax_HT20/VHT20/HE20) UNII 1 : 5 190 ㎒ ~ 5 230 ㎒ (802.11n/ac/ax_HT40/VHT40/HE40) UNII 3 : 5 745 ㎒ ~ 5 825 ㎒ (802.11a/n/ac/ax_HT20/VHT20/HE20) UNII 3 : 5 755 ㎒ ~ 5 795 ㎒ (802.11n/ac/ax_HT40/VHT40/HE40) Software version : V1.1.10 Hardware version : V1.0 Test device serial No. : MACG0KO60500003 Operation temperature : -20 °C ~ 50 °C Eurofins KCTL Co.,Ltd. 65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16677, Korea TEL: 82-70-4904-0113 FAX: 82-505-299-8311 www.kctl.co.kr Report No.: KR26-SRF0150 Page (5) of (85) KCTL-TIR001-003/7 (220705) KP25-08158 2.1. Frequency/channel operations This device contains the following capabilities: WLAN 5 ㎓_802.11a/n(HT20/40)/ac(VHT20/40)/ax(HE20/40) UNII-1 UNII-3 Ch. Frequency (㎒) 36 5 180 40 5 200 48 5 240 Ch. Frequency (㎒) 149 5 745 157 5 785 165 5 825 Table 2.1.1. 802.11a/n/ac/ax HT20/VHT20/HE20 UNII-1 UNII-3 Ch. Frequency (㎒) 38 5 190 46 5 230 Ch. Frequency (㎒) 151 5 755 159 5 795 Table 2.1.2. 802.11n/ac/ax HT40/VHT40/HE40 Eurofins KCTL Co.,Ltd. 65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi…
Text truncated - open the document above for the full version.
Eurofins KCTL Co.,Ltd. 65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16677, Korea TEL: 82-70-4904-0113 FAX: 82-505-299-8311 www.kctl.co.kr Report No.: KR26-SRF0150 Page (31) of (85) KCTL-TIR001-003/7 (220705) KP25-08158 In order to simplify the report, attached plots were the worst case per bandwidth 99% bandwidth UNII 3 / 802.11ax HE20 / Low ch. UNII 3 / 802.11ax HE40 / Low ch. UNII 3 / 802.11ax HE20 / Mid ch. UNII 3 / 802.11ax HE40 / High ch. UNII 3 / 802.11ax HE20 / High ch. Blank Eurofins KCTL Co.,Ltd. 65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16677, Korea TEL: 82-70-4904-0113 FAX: 82-505-299-8311 www.kctl.co.kr Report No.: KR26-SRF0150 Page (32) of (85) KCTL-TIR001-003/7 (220705) KP25-08158 7.5. Frequency stability Test setup Temperature & Humidity EUT Attenuator Spectrum analyzer Limit According to §15.407(g), Manufacturers of U-NII devices are responsible for ensuring frequency stability such that an emission is maintained within the band of operation under all conditions of normal operation as specified in the users manual. According to RSS-Gen(6.11), For licence-exempt devices, the following conditions apply: (a) at the temperatures of -20°C (-4°F), +20°C (+68°F) and +50°C (+122°F), and at the manufacturer’s rated supply voltage (b) at the temperature of +20°C (+68°F) and at ±15% of the manufacturer's rated supply voltage If the frequency stability limits are only met within a temperature range that is smaller than the range specified in (a) for licensed or licence-exempt devices, the frequency stability requirement will be deemed to be met if the transmitter is automatically prevented from operating outside this smaller temperature range and if the published operating characteristics for the equipment are revised to reflect this restricted temperature range. If the device contains both licence and licence-exempt transmitter modules, the device’s frequency stability shall be measured under the most stringent condition specified in the applicable RSS of the transmitter module. In addition, if an unmodulated carrier is not available, the method used to measure frequency stability shall be described in the test report. According to RSS-Gen(8.11), If the frequency stability of the licence-exempt radio apparatus is not specified in the applicable RSS, the fundamental emissions of the radio apparatus should be kept within at least the central 80% of its permitted operating frequency band in order to minimize the possibility of out-of-band operation. In addition, its occupied bandwidth shall be entirely outside the restricted bands and the prohibited TV bands of 54-72 ㎒, 76-88 ㎒, 174-216 ㎒, and 470-602 ㎒, unless otherwise indicated. Test procedure ANSI C63.10 - Section 6.8 Eurofins KCTL Co.,Ltd. 65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16677, Korea TEL: 82-70-4904-0113 FAX: 82-505-299-8311 www.kctl.co.kr Report No.: KR26-SRF0150 Page (33) of (85) KCTL-TIR001-003/7 (220705) KP25-08158 Test results Test band : UNII-1 Frequency (㎐) : 5 180 000 000 Voltage (%) Power (V) Temp. (°C) Frequency ( ㎐ ) Frequency error ( ㎐ ) Deviation Limit (%) ( ㎒ ) 100 11.10 22(Ref.) 517 997 842 0 -21 580.000 -0.000 417 5 150 ≤ F ≤ 5 250 -20 517 997 403 0 -25 970.000 -0.000 501 -10 517 998 382 0 -16 180.000 -0.000 312 0 517 998 521 0 -14 790.000 -0.000 286 10 517 998 022 0 -19 780.000 -0.000 382 20 517 998 122 0 -18 780.000 -0.000 363 30 517 997 363 0 -26 370.000 -0.000 509 40 517 997 243 0 -27 570.000 -0.000 532 50 517 997 682 0 -23 180.000 -0.000 447 85 9.44 22(Ref.) 517 997 862 0 -21 380.000 -0.000 413 115 12.77 22(Ref.) 517 997 862 0 -21 380.000 -0.000 413 -3.5 -2.5 -1.5 -0.5 0.5 1.5 2.5 3.5 22(Ref.)-2010010203040502222 Deviation [%] Temperature [°C] Frequency Stability Eurofins KCTL Co.,Ltd. 65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16677, Korea TEL: 82-70-4904-0113 FAX: 82-505-299-8311 www.kctl.co.kr Report No.: KR26-SRF0150 Page (34) of (85) KCTL-TIR001-003/7 (220705) KP25-08158 Test band : UNII-3 Frequency (㎐) : 5 745 000 000 Voltage (%) Power (V) Temp. (°C) Frequency ( ㎐ ) Frequency error ( ㎐ ) Deviation Limit (%) ( ㎒ ) 100 11.10 22(Ref.) 574 497 702 0 -22 980.000 -0.000 400 5 725 ≤ F ≤ 5 850 -20 574 497 123 0 -28 770.000 -0.000 501 -10 574 498 222 0 -17 780.000 -0.000 309 0 574 498 302 0 -16 980.000 -0.000 296 10 574 497 802 0 -21 980.000 -0.000 383 20 574 497 862 0 -21 380.000 -0.000 372 30 574 497 063 0 -29 370.000 -0.000 511 40 574 496 923 0 -30 770.000 -0.000 536 50 574 497 463 0 -25 370.000 -0.000 442 85 9.44 22(Ref.) 574 497 702 0 -22 980.000 -0.000 400 115 12.77 22(Ref.) 574 497 702 0 -22 980.000 -0.000 400 -3.5 -2.5 -1.5 -0.5 0.5 1.5 2.5 3.5 22(Ref.)-2010010203040502222 Deviation [%] Temperature [°C] Frequency Stability Eurofins KCTL Co.,Ltd. 65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16677, Korea TEL: 82-70-4904-0113 FAX: 82-505-299-8311 www.kctl.co.kr Report No.: KR26-SRF0150 Page (35) of (85) KCTL-TIR001-003/7 (220705) KP25-08158 7.6. Spurious Emission, Band Edge and Restricted bands Test setup The diagram below shows the test setup that is utilized to make the measurements for emission from 9 ㎑ to 30 ㎒ Emissions The diagram below shows the test setup that is utilized to make the measurements for emission from 30 ㎒ to 1 ㎓ emissions. The diagram below shows the test setup that is utilized to make the measurements for emission from 1 ㎓ to the tenth harmonic of the highest fundamental frequency or to 40 ㎓ emissions, whichever is lower. Eurofins KCTL Co.,Ltd. 65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16677, Korea TEL: 82-70-4904-0113 FAX: 82-505-299-8311 www.kctl.co.kr Report No.: KR26-SRF0150 Page (36) of (85) KCTL-TIR001-003/7 (220705) KP25-08158 Limit FCC According to section 15.209(a), except as provided elsewhere in this subpart, the emissions from an intentional radiator shall not exceed the field strength levels specified in the following table: Frequency ( ㎒ ) Field strength ( ㎶ /m) Measurement distance (m) 0.009 - 0.490 0.490 - 1.…
Text truncated - open the document above for the full version.
5809 US-2, Suite B, · Priest River, 83856 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15E | 5.18 GHz - 5.24 GHz | 3.00 mW |
| 2 | 15E | 5.75 GHz - 5.83 GHz | 3.00 mW |