Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Instructions ● Be sure to read the quick guide and use it correctly. ● There is a product warranty on the back of the user manual, please keep it so that . 1.Be careful not to tip over or drop the projector when connecting an external device. It may cause injury or product damage. 2.Do not place the product near sunlight, candles, heat sources (stoves, microwaves). (It may deform the product or cause an explosion or fire.) 3.Do not cover the product with a cover or use it in a poorly ventilated area. (It degrades the performance of the projector, overheating may cause fault, etc.) 4.Do not look directly into the light of the projected lens or project it into your eyes. (Projected light may be harmful to your eyes,) 5.Do not install on a wall or ceiling where oil or oil vapor may come in contact. The product may be damaged and fall. 6.Do not replace the lamp or other electrical parts without unplugging the projector. 7.Do not apply shock to the product, don’t place it where there is vibration or magnets. Please stay away. (It may cause product failure.) 8.In case of smoke or strange noise or smell, stop using it immediately and contact your distributor. 9.If the product is disassembled or remodeled arbitrarily, even if it is in the warranty, you should afford the repairing costs. 10.Unplug the adapter from the AC outlet, you can’t use the projector for a long time. 11.We are not responsible for the damage or defects caused by user negligence. All repairs are professional if you ask a technician. 12.Fan noise is not a defect of the product. 13.Do not allow pets to suck or bite this product. Notice : 1) The picture may differ from the actual product. Various accessories are subject to change without notice to improve product quality. New accessories may be added or deleted. . 2)Due to the nature of the beam projector, the top and bottom edges of the screen may be blurred. This is due to the nature of the optical engine, and it is not a product malfunction. The proper I throw distance is 100cm~200cm. . * The longer the projection distance, the more blurred the screen. . 3) Install the projector so that it is perpendicular to the projection screen. If the image is distorted or curved, please check if the projector is installed properly by installing it on a level surface. . 4) The projector can be installed using a camera tripod. When fixing the tripod, the length of the fastening bolt is recommended to use the international standard of 4.5mm or less. The allowable length of the fastening bolt is 5.5mm maximum. Anything longer may damage the projector. Be careful when using a tripod as external force may cause the projector to topple over and cause damage. Do not install the tripod on an unstable place. . . Projector Adapter Quick Guide Remote HDMI Cable Product Functions 2: Cooling Fan 3: Up 4: OK / Return(Press 5 seconds) 5: Right 6: Left 7: Down 8: Indicator 9 : Headphone(3.5mm) 10: USB 11: HDMI 12: DC port (15V/1.5A) 1: Power 2: Speaker 3: Tripod Hole 4: Label 5: Anti-slip Mat 6: Focus Wheel 7 8 AAA Battery Volume Adjustment Power ON/OFFHome Confirm Up/Down/Left/Right Go to menu item and select Menu Mouse Function Return Indicator Remote Control The wireless remote control must be connected before using the projector. After turning on the projector, press and hold the volume-key and volume+key for 3 seconds When pressed, the indicator on the remote control blinks and a sound ▶ 1) USB - In the case of a USB storage device with a built-in automatic recognition program or using its own driver,itmaynotwork. - Some USB storage devices may not work or operate smoothly.. - If a USB extension cable is used, it may not work or may not operate smoothly.. - Use only FAT32 formatted USB storage devices provided by Windows. - For an external USB hard disk, use a device with a rated voltage of 5 V and a rated current of 500 mA or less. - It is recommended to use a hard disk with power supply. (If the power is insufficient, the USB . device may not be recognized properly. - USB capacity of 32GB is recognized as standard, but 128GB may also recognized.. - Data on the USB storage device may be damaged, so back up important files somewhere else. . - User should responsible for the data, the manufacturer isn’t responsible for the data. - Multi-port is also available for USB port.. - Some apps do not support mouse wheel. Supported Video format 2) HDMI ●To connect a laptop or PC with a cable, - Connect the mini beam with an HDMI cable. - Right-click on the PC desktop and click (Screen Resolution/Display Settings) and select the recommended resolution.(The setting method may differ depending on the Windows version.) - When the desired image does not come out of the projector - Check whether the video is displayed normally from the PC/laptop. - Set the display settings in the PC control panel correctly. - If there is no image after connecting a laptop/PC, the resolution of the computer being used is not compatible with the projector. It is set beyond the acceptable resolution. ● List of additional compatibility adapters Some devices may require an additional adapter to connect via HDMI. (For example, an iPhone or iPad requires a Lighting to HDMI AV adapter) Devices with HDMI port Devices with mini HDMI port Devices with micro ★ HDMI to HDMI cable (include) HDMI portd) ★ HDMI to HDMI cable★ Mini HDMI to HDMI adapter ★ HDMI to HDMI cable★Micro HDMI to HDMI adapter 1 2 3 USB-C USB-C iOS devices with lightning port Devices with USB-C (USB type C) port Devices with USB-C (USB type C) port ★ HDMI to HDMI cable★Lightning digital AV adapter ★ HDMI to HDMI cable ★USB-C to HDMI adapter ★USB type C to HDMI cable 4 5 6 Charging 1, When the red light flashes: Battery Low. 2, Red light is on: charging 3, White light on: Fully charged Focus the projected image clarity. Rechargeable battery function Android Device Connection ▶ Mirroring Projector: Select Main Menu-Screen Mirroring- Miracast, check PRO-**** in Smart View of you…
Text truncated - open the document above for the full version.
FCC Software Configuration Control Declaration Rev1.1 SHENZHEN HOMAN TECHNOLOGY CO.,LTD FCC Software Configuration Control Declaration Date: Sep 20, 2022 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Attn: OET Dept. Product/ Model Number: PROJECTOR/S90, NS60, NP60, WP90, NS90, R-01, ZEUS A300N, ZEUS A500, A500, A300, A300N, AS60, WP60, AS90, WS180, WP180, AS180, FS300, AS300 Regarding FCC Country Code Selection guidelines identified in KDB 594280. “All applications for equipment authorization for transmitters that can have radio parameters, or other technical parameters, reported to the Commission set by software must have an attestation indicating that no third party will have software, or configuration control, to program the device out of compliance of the technical rules under which it has been certified.” We declare that no third party will have software, or configuration control, to program the device out of compliance of the technical rules under which it has been certified. Date: 2022-9-20 Name:ming sheng wu Title: manager Signature of applicant
ShenZhen Homan Technology Co., LTD Agent Authorization Company: ShenZhen Homan Technology Co., LTD Address: Room 808A, Block A, Zhihui Chuangxin Center, Baoan, Shenzhen Product Name: PROJECTOR Model Number(s): S90, NS60, NP60, WP90, NS90, R-01, ZEUS A300N, ZEUS A500, A500, A300, A300N, AS60, WP60, AS90, WS180, WP180, AS180, FS300, AS300 We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Date: Sep. 20, 2022 Signature: Name: ming sheng wu Title: manager Company: ShenZhen Homan Technology Co., LTD
ShenZhen Homan Technology Co., LTD Date: Sep. 20, 2022 Offic e of Engineering Technology Federal Communications Commission 743 5 Oakland Mill s Road Columbia, MD 21046 USA Subject; Request for Confidentiality FCC ID: 2A3WC-S90 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705 . OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: ming sheng wu Title: manager Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure FCC Software Security Requirements for UNII devices
ShenZhen Homan Technology Co., LTD Model Confirmation Letter We, ShenZhen Homan Technology Co., LTD, certify the product: PROJECTOR , Model No.: S90, NS60, NP60, WP90, NS90, R-01, ZEUS A300N, ZEUS A500, A500, A300, A300N, AS60, WP60, AS90, WS180, WP180, AS180, FS300, AS300 All models have the same functionality, software and electronics, only the model names may differ. Test sample model: S90 Signiture: Grantee Contact : ming sheng wu Company Name: ShenZhen Homan Technology Co., LTD Date: 2022-9-22
Label place Size:20*32mm PROJECTOR Model: S90 FCC ID: 2A3WC-S90 Input: DC15V 1.5A Output:DC5.0V 1A
BT ANT 2.4G/5GWIFI ANT RX ANT
FCC ID: 2A3WC-S90 RF Exposure Evaluation According to KDB447498D01 General RF Exposure Guidance v06 4.3.1. Standalone SAR test exclusion considerations Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Exclusion Threshold condition, listed below, is satisfied. Limits According to FCC Part1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in part1.1307(b) F= Frequency in MHz Friis Formula Friis transmission formula: Pd = (Pout*G)/(4* Pi * R 2) Where Pd = power density in mW/cm2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center of the radiator in cm Pd id the limit of MPE . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. Test Result of RF Exposure Evaluation EDR/BLE-PCB ANT: 2.94 dBi 2.4G- W IFI ANT1: 2.94dBi; W IFI ANT2: 6.71dBi ; MIMO:9.72dBi 5G- W IFI ANT1: 4.57dBi; W IFI ANT2: 4.22dBi ; MIMO: 7.58dBi Antenna Gain: The maximum Gain measured in fully anechoic chamber is 1.0 in linear scale. Output Power Into Antenna & RF Exposure Evaluation Distance: Measurement Data The Max Conducted Peak Output Power data refer to report Report No.: ZKT-220830L6257-01 & ZKT-220830L6257-02 & ZKT-220830L6257-03 & ZKT-220830L6257-04 BT/BLE-worst mode and channel: Test channel Output Power (dBm) Tune up tolerance (dBm) Maximum tune-up Power Calculated value (dBm) (mW) (BT) 8-DPSK Highest channel 6.24 7±1 8 6.310 0.00247 (BLE-1Mbps)GFSK Lowest channel 4.52 5±1 6 3.981 0.001558 Limit: 1.0 EUT RF Exposure Evaluation simultaneous transmission operations According to 865664D02 2.2 d) 1): The sum of the ratios of the spatially averaged results to the applicable frequency dependent MPE limits : Simultaneous transmission mode The sum of the ratios SUM Limit BT+ BLE 0.00247+0.001558 0.004028 1.0 conclusion : 0.004028 <1.0, So there is no sar requirement 2.4GW IFI-worst mode and channel: Test channel Antenna Output Power (dBm) Tune up tolerance (dBm) ANT1 ANT2 SUM ANT1 ANT2 SUM 802.11n –2412MHz 16.87 17.38 16.87 17±1 17±1 20.01±1 802.11n –2412MHz 16.60 17.09 16.60 17±1 17±1 20.01±1 802.11n –2412MHz 16.63 17.34 16.63 17±1 17±1 20.01±1 Test worst case Maximum tune-up Power (dBm) Maximum tune-up Power (mW) Calculated value (mW/cm2) Limit (mW/cm2) ANT1 ANT2 SUM ANT1 ANT2 SUM / / 18 17 21.01 63.10 63.10 126.19 0.2354 1.0 Remark: 1)The Max Conducted Peak Output Power data refer to report Report No.: ZKT-220830L6257-03 2) Pd = (Pout*G)/(4* Pi * R 2 )=( 126.19*9.3756)/(4*3.14159*20*20)=0.2354, G=10 gain/10 =9.3756 5GW IFI- worst mode and channel: Mode Test channel Antenna Output Power (dBm) Tune up tolerance (dBm) Max Tune up (dBm) ANT1 ANT2 SUM ANT1 ANT2 SUM 802.11ac-5745MHz 16.64 17.92 20.34 17±1 17±1 20.01±1 21.01 802.11ac-5785MHz 16.12 17.78 20.04 17±1 17±1 20.01±1 21.01 802.11ac-5825MHz 16.50 17.28 19.92 17±1 17±1 20.01±1 21.01 Test worst case Maximum tune-up Power (dbm) Maximum tune-up Power (mW) Calculated value (mW/cm2) Limit (mW/cm2) 21.01 126.19 0.1438 1.0 Remark: 1)The Max Conducted Peak Output Power data refer to report Report No.: ZKT-220808L4384-04 2) Pd = (Pout*G)/(4* Pi * R 2 )=( 126.19 *5.728)/(4*3.14159*20*20)=0.1438 , G=10 gain/10 =5.728 EUT RF Exposure Evaluation simultaneous transmission operations According to 865664D02 2.2 d) 1): The sum of the ratios of the spatially averaged results to the applicable frequency dependent MPE limits : Simultaneous transmission mode The sum of the ratios SUM Limit BT+2.4G W IFI + 5G W IFI 0.004028+0.2354+0.1438 ≈0.383 1.0 conclusion : 0.383< 1.0, So there is no sar requirement NOTE: 1. EUT wifi-5G module & wifi-2.4G module is more than 20cm away from the human body. 2. The sum of the ratios(2.4GW IFI + 5G W IFI+BT) is less than the limit value of 1.0, so there is no sar requirement.
Project No.: ZKT- 220830L6257-04 Page 1 of 105 FCC TEST REPORT FCC ID:2A3WC-S90 Report Number............................... : ZKT-220830L6257-04 Date of Test...................................... : Aug. 23, 2022 -- Sep. 14, 2022 Date of issue .................................... : Sep. 14, 2022 Total number of pages ..................... : 105 Test Result ....................................... : PASS Testing Laboratory. ....................... : Shenzhen ZKT Technology Co., Ltd. Address .......................................... : 1/F, No. 101, Building B, No. 6, Tangwei Community Industrial Avenue, Fuhai Street, Bao'an District, Shenzhen, China Applicant's name ......................... : SHENZHEN HOMAN TECHNOLOGY CO.,LTD Address .......................................... : Room 808A,Block A,Zhihui Chuangxin Center,Baoan,Shenzhen Manufacturer's name ................... : SHENZHEN HOMAN TECHNOLOGY CO.,LTD Address .......................................... : Room 808A,Block A,Zhihui Chuangxin Center,Baoan,Shenzhen Test specification: Standard .......................................... : FCC CFR Title 47 Part 15 Subpart E Section 15.407 ANSI C63.10:2013 KDB 789033 D02 V01r02 Test procedure................................. : / Non-standard test method ............. : N/A Test Report Form No. .................... : TRF-EL-110_V0 Test Report Form(s) Originator .... : ZKT Testing Master TRF ................................... : Dated: 2020-01-06 This device described above has been tested by ZKT, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of ZKT, this document may be altered or revised by ZKT, personal only, and shall be noted in the revision of the document. Product name ................................. : PROJECTOR Trademark ...................................... : AUSWEE Model/Type reference ...................... : S90, NS60, NP60, WP90, NS90, R-01, ZEUS A300N, ZEUS A500, A500, A300, A300N, AS60, WP60, AS90, WS180, WP180, AS180, FS300, AS300 Ratings ............................................ : DC 15V/1.5A from adapter Project No.: ZKT-220830L6257-04 Page 2 of 105 Testing procedure and testing location: Testing Laboratory .................................. : Shenzhen ZKT Technology Co., Ltd. Address ..................................................... : 1/F, No. 101, Building B, No. 6, Tangwei Community Industrial Avenue, Fuhai Street, Bao'an District, Shenzhen, China Alen He Tested by (name + signature) .................... : Joe Liu Reviewer (name + signature)..................... : Lake Xie Approved (name + signature) .................... : Project No.: ZKT-220830L6257-04 Page 3 of 105 Table of Contents Page 1. VERSION 5 2. SUMMARY OF TEST RESULTS 6 2.1 TEST FACILITY 7 2.2 MEASUREMENT UNCERTAINTY 7 3. GENERAL INFORMATION 8 3.1 GENERAL DESCRIPTION OF EUT 8 3.2 DESCRIPTION OF TEST MODES 9 3.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 9 3.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE) 9 3.5EQUIPMENTS LIST FOR ALL TEST ITEMS 11 4. EMC EMISSION TEST 12 4.1 CONDUCTED EMISSION MEASUREMENT 12 4.1.1 POWER LINE CONDUCTED EMISSION LIMITS 12 4.1.2 TEST PROCEDURE 12 4.1.3 DEVIATION FROM TEST STANDARD 12 4.1.4 TEST SETUP 13 4.1.5 EUT OPERATING CONDITIONS 13 4.1.6 TEST RESULT 14 4.2 RADIATED EMISSION MEASUREMENT 16 4.2.1 RADIATED EMISSION LIMITS 16 4.2.2 TEST PROCEDURE 17 4.2.3 DEVIATION FROM TEST STANDARD 17 4.2.4 TEST SETUP 17 4.2.5 EUT OPERATING CONDITIONS 18 4.2.6 TEST RESULTS 19 5.POWER SPECTRAL DENSITY TEST 61 5.1 APPLIED PROCEDURES / LIMIT 61 5.2 TEST PROCEDURE 61 5.3 DEVIATION FROM STANDARD 61 5.4 TEST SETUP 61 5.5 EUT OPERATION CONDITIONS 62 5.6 TEST RESULT 62 6. -26 DB & 6DBM EMISSION BANDWIDTH 73 6.1 APPLIED PROCEDURES / LIMIT 73 6.2 TEST PROCEDURE 73 6.3 DEVIATION FROM STANDARD 73 6.4 TEST SETUP 73 6.5 EUT OPERATION CONDITIONS 73 Project No.: ZKT-220830L6257-04 Page 4 of 105 6.6 TEST RESULT 73 7. OUTPUT POWER TEST 85 7.1 APPLIED PROCEDURES/LIMIT 85 7.2 DEVIATION FROM STANDARD 85 7.3 TEST SETUP 85 7.4 EUT OPERATION CONDITIONS 85 7.5 TEST RESULT 86 8. OUT OF BAND EDGE EMISSION 87 8.1 TEST PROCEDURE 87 8.2 DEVIATION FROM STANDARD 87 8.3 TEST SETUP 87 8.4 EUT OPERATION CONDITIONS 87 8.5 TEST RESULTS 87 9. FREQUENCY STABILITY MEASUREMENT 96 9.4 TEST RESULT 96 10.ANTENNA REQUIREMENT 104 10. TEST SETUP PHOTO 105 11. EUT CONSTRUCTIONAL DETAILS 105 Project No.: ZKT-220830L6257-04 Page 5 of 105 1. VERSION Report No. Version Description Approved ZKT-220830L6257-04 Rev.01 Initial issue of report Sep. 14, 2022 Project No.: ZKT-220830L6257-04 Page 6 of 105 2. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15 (15.247) , Subpart C Standard Section Test Item Result Remark 15.203/15.247 (c) Antenna requirement PASS 15.207 AC Power Line Conducted Emission PASS 15.407 (a) (b) Spurious Radiated Emissions and Band Edge PASS 15.407 (e) /15.403(i) 6 dB bandwidth, 26dB Emission Bandwidth& 99% Occupied Bandwidth PASS 15.407 (a) Power Spectral Density PASS 15.407 (a)(1)(2)(3) Maximum conducted output power PASS 15.407 (g) Frequency Stability PASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report Project No.: ZKT-220830L6257-04 Page 7 of 105 2.1 TEST FACILITY Shenzhen ZKT Technology Co., Ltd. Add. : 1/F, No. 101, Building B, No. 6, Tangwei Community Industrial Avenue, Fuhai Street, Bao'an District, Shenzhen, China FCC Test Firm Registration Number: 692225 Designation Number: CN1299 IC Registered No.: 27033 2.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %。 Project No.: ZKT-220830L6257-04 Page 8 of 105 3. GENERAL INFORMATION 3.1 GENERAL DESCRIPTION OF E…
Text truncated - open the document above for the full version.
Project No.: ZKT-220830L6257-04 Page 73 of 105 6. -26 DB & 6DBM EMISSION BANDWIDTH Test Requirement: Part 15 Subpart C Section 15.407 (e) Test Method: KDB 789033 D02 v02r01 6.1 APPLIED PROCEDURES / LIMIT FCC Part15.407 (e) Bandwidth Limit U-NII-1 N/A U-NII-3 ≥ 500 kHz 6.2 TEST PROCEDURE Place the EUT on the table and set it in the transmitting mode. Remove the antenna from the EUT and then connect a low-loss RF cable from the antenna port to the spectrum analyzer. Set the spectrum analyzers RBW = approximately 1% of the emission bandwidth, VBW >RBW, Detector = Peak, Span>26dB bandwidth, and Sweep = auto ,Trace mode = max hold. Measure the maximum width of the emission that is 26dB down from the maximum of the emission. Compare this with the RBW setting of the analyzer. Readjust RBW and repeat measurement as needed until the RBW/EBW ratio is approximately 1%. Repeat until all the rest channels were investigated. 6.3 DEVIATION FROM STANDARD No deviation. 6.4 TEST SETUP 6.5 EUT OPERATION CONDITIONS The EUT tested system was configured as the statements of 2.4 Unless otherwise a special operating condition is specified in the follows during the testing. 6.6 TEST RESULT Temperature: 26°C Relative Humidity: 54% Pressure: 101kPa Test Voltage : AC120V Test Mode : TX Project No.: ZKT-220830L6257-04 Page 74 of 105 U-NII-1 802.11 Mode Channel No. Frequency [MHz] 26dB Bandwidth [MHz] 99% Bandwidth [MHz] ANT1 ANT2 ANT1 ANT2 a 36 5180 19.06 19.18 16.433 16.448 40 5200 19.19 19.36 16.361 16.402 48 5240 19.23 18.96 16.469 16.413 n (20MHz) 36 5180 20.11 20.12 17.553 17.579 40 5200 20.03 19.83 17.581 17.553 48 5240 19.67 20.13 17.534 17.559 ac (20MHz) 36 5180 19.51 20.12 17.557 17.584 40 5200 19.82 19.88 17.585 17.573 48 5240 19.79 20.16 17.572 17.594 n(40MHz) 38 5190 40.49 41.05 36.118 36.259 46 5230 39.63 40.52 36.230 36.268 ac(40MHz) 38 5190 41.75 41.45 36.288 36.279 46 5230 41.16 41.09 36.186 36.260 ac(80MHz) 42 5210 81.00 80.65 75.547 75.590 U-NII-3 802.11 Mode Channel No. Frequency [MHz] -6db Bandwidth [MHz] Limit ANT1 ANT2 a 149 5745 16.39 16.47 ≥ 500 kHz 157 5785 16.36 16.43 165 5825 16.42 16.49 n (20MHz) 149 5745 17.54 17.32 157 5785 16.65 17.29 165 5825 16.94 17.31 n (40MHz) 151 5755 16.95 17.33 159 5795 17.27 16.80 ac (20MHz) 149 5745 17.31 17.27 157 5785 36.16 36.39 165 5825 35.77 36.46 ac(40MHz) 151 5755 36.05 36.38 159 5795 35.57 36.42 ac(80MHz) 155 5775 75.26 75.24 Test plot as follows: Project No.: ZKT-220830L6257-04 Page 75 of 105 U-NII-1– 802.11a ANT1 ANT2 CH36-5180MHz CH36-5180MHz CH40-5200MHz CH40-5200MHz CH48-5240MHz CH48-5240MHz Project No.: ZKT-220830L6257-04 Page 76 of 105 U-NII-1 – 802.11n (20MHz) ANT1 ANT2 CH36-5180MHz CH36-5180MHz CH40-5200MHz CH40-5200MHz CH48-5240MHz CH48-5240MHz Project No.: ZKT-220830L6257-04 Page 77 of 105 U-NII-1 – 802.11n (40MHz) ANT1 ANT2 CH38-5190MHz CH38-5190MHz CH46-5230MHz CH46-5230MHz U-NII-1 – 802.11ac 20MHz) ANT1 ANT2 CH36-5180MHz CH36-5180MHz Project No.: ZKT-220830L6257-04 Page 78 of 105 CH40-5200MHz CH40-5200MHz CH48-5240MHz CH48-5240MHz U-NII-1 – 802.11ac (40MHz) ANT1 ANT2 CH38-5190MHz CH38-5190MHz Project No.: ZKT-220830L6257-04 Page 79 of 105 CH46-5230MHz CH46-5230MHz U-NII-1 –802.11ac (80MHz) ANT1 ANT2 CH42 5210MHz CH42 5210MHz U-NII-3 –802.11a ANT1 ANT2 CH149 -5745MHz CH149 -5745MHz Project No.: ZKT-220830L6257-04 Page 80 of 105 CH157 -5785MHz CH157 -5785MHz CH165 -5825MHz CH165 -5825MHz U-NII-3–802.11n (20MHz) ANT1 ANT2 CH149 -5745MHz CH149 -5745MHz Project No.: ZKT-220830L6257-04 Page 81 of 105 CH157 -5785MHz CH157 -5785MHz CH165 -5825MHz CH165 -5825MHz U-NII-3 – 802.11n (40MHz) ANT1 ANT2 CH151 -5755MHz CH151 -5755MHz Project No.: ZKT-220830L6257-04 Page 82 of 105 CH159 -5795MHz CH159 -5795MHz U-NII-3 –802.11ac (20MHz) ANT1 ANT2 CH149 -5745MHz CH149 -5745MHz CH157 -5785MHz CH157 -5785MHz Project No.: ZKT-220830L6257-04 Page 83 of 105 CH165 -5825MHz CH165 -5825MHz U-NII-3 – 802.11ac (40MHz) ANT1 ANT2 CH151 -5755MHz CH151 -5755MHz CH159 -5795MHz CH159 -5795MHz Project No.: ZKT-220830L6257-04 Page 84 of 105 U-NII-3 – 802.11ac (80MHz) ANT1 ANT2 CH155 -5775MHz CH155 -5775MHz Project No.: ZKT-220830L6257-04 Page 85 of 105 7. OUTPUT POWER TEST Test Requirement: 15.407 (a)(1)(2)(3) Test Method: KDB 789033 D02 v02r01 7.1 APPLIED PROCEDURES/LIMIT For client devices in the 5.15-5.25 GHz band, the maximum conducted output power over the frequency band of operation shall not exceed 250 mW provided the maximum antenna gain does not exceed 6 dBi. In addition, the maximum power spectral density shall not exceed 11 dBm in any 1 megahertz band. If transmitting antennas of directional gain greater than 6 dBi are used, both the maximum conducted output power and the maximum power spectral density shall be reduced by the amount in dB that the directional gain of the antenna exceeds 6 dBi. For the band 5.725-5.850 GHz, the maximum conducted output power over the frequency band of operation shall not exceed 1 W. In addition, the maximum power spectral density shall not exceed 30 dBm in any 500-kHz band. If transmitting antennas of directional gain greater than 6 dBi are used, both the maximum conducted output power and the maximum power spectral density shall be reduced by the amount in dB that the directional gain of the antenna exceeds 6 dBi. Test Item Band Limit Result Max conducted output power U-NII-1 0.25W / 23.98dbm Pass Max conducted output power U-NII-3 1 W / 30dbm Pass 7.2 DEVIATION FROM STANDARD No deviation. 7.3 TEST SETUP 7.4 EUT OPERATION CONDITIONS The EUT tested system was configured as the statements of 2.4 Unless otherwise a special operating condition is specified in the follows during the testing. Project No.: ZKT-220830L6257-04 Page 86 of 105 7.5 TEST RESULT Temperature: 26°C Relative Humidity: 54% Pressure: 101kPa Test Voltage : AC120V U-NII-1 802.11 Mode Channel No. Frequency [MHz] Conducted Power [dBm] Limit [dBm] MIMO [dBm] Limit [dBm] ANT1 ANT2 a 36 5180 13.79 14.93 23.98 / / 40 5200 11.72 12.32 23.98 / / 48 5240 12.16 13.86 23.98 / /…
Text truncated - open the document above for the full version.
Shenzhen QinXin Technology Co.,Ltd Antenna Test Report •• The antenna characteristics use the microwave anechoic chamber of the ETS test system, the size of the microwave anechoic chamber is 7m x 4m x 3m, and the test frequency is 700MHz---6GHz. •• S11 testing using Agilent E5071B network analyzer test environment wifi-1 2.4G+5G Return Loss Graph 2.4G WiFi Antenna efficiency wifi-1 240040.76-3.90 241042.45-3.720.22 242043.38-3.630.44 243047.9-3.21.03 244051.62-2.871.6 245054.02-2.672.03 246054.21-2.662.07 247053.49-2.722.06 248057.48-2.42.5 249061.63-2.12.84 250061.09-2.142.94 Passive Test For WII2.4 FreqEffiEffiGain (MHz)(%)(dB)(dBi) 深圳勤新科技有限公司 5GWiFi Antenna efficiency WIFI-1 Passive Test For WII5.8 FreqEffiEffiGainFreqEffiEffiGainFreqEffiEffiGain (MHz)(%)(dB)(dBi)(MHz)(%)(dB)(dBi)(MHz)(%)(dB)(dBi) 515066.74-1.763.77539060.78-2.163.65563061.33-2.123.52 516060.43-2.193.38540064.91-1.883.91564059.89-2.233.09 517056.71-2.463.09541072.63-1.394.79565064.52-1.93.75 518054.98-2.62.8542077.7-1.15.19566060.59-2.183.12 519066.96-1.743.56543070.33-1.534.8567062.53-2.043.03 520065.3-1.853.39544071.5-1.465.06568057.46-2.412.74 521064.17-1.933.29545065.21-1.864.78569056.09-2.512.46 522058.75-2.312.95546069.19-1.65.22570056.25-2.52.3 523060.85-2.163.06547072.51-1.45.52571053.82-2.692.75 524066.08-1.83.39548068.57-1.645.16572056.32-2.492.45 525064.69-1.893.2549073.55-1.335.59573056.09-2.512.15 526064.2-1.923.08550067.87-1.685.2574054.18-2.662.37 527059.08-2.292.69551064.8-1.885.01575053.79-2.692.42 528056.44-2.482.43552070.88-1.494.78576048.62-3.132.43 529060.21-2.22.49553067.1-1.734.68577050.43-2.972.75 530057.13-2.432.19554072.56-1.395.12578048.22-3.172.84 531063.59-1.972.67555070.8-1.54.62579049.24-3.082.53 532065.44-1.842.86556068.84-1.624.47580047.58-3.232.61 533057.86-2.382.46557069.35-1.594.42581045.44-3.432.45 534060.92-2.152.4558066.65-1.763.91582044.36-3.532.59 535056.8-2.462.55559067.24-1.724.23583043.14-3.653 536068.21-1.663.68560071.03-1.494.4584045.79-3.391.83 537070.21-1.543.65561063.01-2.013.92585044.15-3.552.96 538062.36-2.053.47562067.25-1.723.76 wifi-2 2.4G+5G Return Loss Graph 2.4G WiFi Antenna efficiency wifi-2 240058.94-2.36.71 241055.46-2.566.44 242049.78-3.035.88 243050.43-2.975.74 244050.51-2.975.6 245048.43-3.155.32 246046.2-3.355.02 247041.67-3.84.57 248041.17-3.854.42 249044.24-3.544.69 250042.98-3.674.49 Passive Test For WII2.4 FreqEffiEffiGain (MHz)(%)(dB)(dBi) 5GWiFi Antenna efficiency WIFI-2 Passive Test For WII5.8 FreqEffiEffiGainFreqEffiEffiGainFreqEffiEffiGain (MHz)(%)(dB)(dBi)(MHz)(%)(dB)(dBi)(MHz)(%)(dB)(dBi) 515059.84-2.233.6539063.72-1.962.62563060.54-2.183.49 516057.69-2.393.36540074.98-1.253.61564057.36-2.413.23 517054.96-2.63.41541077.56-1.13.78565060.97-2.153.62 518057.45-2.413.7542079.5-13.95566056.9-2.453.38 519059.58-2.254.1543074.18-1.33.9567060.67-2.173.63 520057.64-2.394.05544073.59-1.333.77568055.34-2.573.36 521056.03-2.523.94545073.04-1.363.83569052.42-2.83.13 522051.05-2.923.45546073.42-1.343.97570052.55-2.793.06 523059.85-2.234.08547074.83-1.264.03571048.86-3.112.63 524060.72-2.173.85548072.41-1.44.07572051.46-2.892.95 525059.48-2.263.66549073.76-1.324.16573051-2.923.08 526059.15-2.283.38550073.13-1.364.13574048.22-3.172.7 527052.84-2.772.56551069.01-1.613.89575048.05-3.182.89 528058.22-2.352.96552073.18-1.364.06576041-3.872.22 529061.43-2.123.13…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15E | 5.75 GHz - 5.83 GHz | 108.10 mW |