FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Ningbo Sunpu Led Co.,Ltd/
  3. 2A3ZE-FLD20X11

2A3ZE-FLD20X11LUM-FLD20X110W08BK-3WF

Ningbo Sunpu Led Co.,Ltd
LUM-FLD20X110W08BK-3WF - FCC ID 2A3ZE-FLD20X11 - Ningbo Sunpu Led Co.,Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 19, 2022
Application Purpose
Original Equipment
Date of Application
Jan 19, 2022
Equipment Note
LUM-FLD20X110W08BK-3WF
Frequency Range
2402.00000000 - 2480.00000000
Company
Ningbo Sunpu Led Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

LUM-FLD20X110W08BK-3WF FCC Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Warning: Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: (1) Reorient or relocate the receiving antenna. (2) Increase the separation between the equipment and receiver. (3) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. (4) Consult the dealer or an experienced radio/TV technician for help. FCC Radio Frequency Exposure Statement IC Statement This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil nedoit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. IC RF Statement: When using the product, maintain a distance of 20cm from the body to ensure compliance with RF exposure requirements. Lors de l'utilisation du produit, maintenez une distance de 20 cm du corps afin de vous conformer aux exigences en matière d'exposition RF. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter, End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

External Photos

Page 1 of 4 External Picture Page 2 of 4 External view View of control module Page 3 of 4 View of control module (Optional-only different the connect port) Page 4 of 4 Adaptor of the YN-15WA120075US Adaptor of the AED09-01200750GQIP20-5

ID Label/Location Info

位置示意图: 铭牌粘贴位置 位置示意图: 铭牌粘贴位置

Internal Photos

Page 1 of 5 Internal Picture Page 2 of 5 Internal view Page 3 of 5 View of LED module Page 4 of 5 Interview of control module Antenna Page 5 of 5

RF Exposure Info

Ningbo Sunpu Led Co Ltd MPE ASSESSMENT REPORT Report Type: FCC MPE assessment report Model: LUM-FLD20X110W08BK-3WF REPORT NUMBER: 210800239HZH-003 ISSUE DATE: December 30, 2021 DOCUMENT CONTROL NUMBER: TTRFFCCMPE-01_V1 © 2018 Intertek Intertek Testing Services Shanghai Building No.86, 1198 Qinzhou Road (North) Caohejing Development Zone Shanghai 200233, China Telephone: 86 21 6127 8200 www.intertek.com TEST REPORT This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. TTRFFCCMPE-01_V1© 2018 Intertek Page 2 of 9 Report no.: 210800239HZH-003 Applicant: Ningbo Sunpu Led Co Ltd No.150, Xin Hui Road Hi-Tech Park, NINGBO Zhejiang 315040, China. Manufacturer: Ningbo Sunpu Led Co Ltd No.150, Xin Hui Road Hi-Tech Park, NINGBO Zhejiang 315040, China. Factory Ningbo Sunpu Led Co Ltd No.150, Xin Hui Road Hi-Tech Park, NINGBO Zhejiang 315040, China. FCC ID: 2A3ZE-FLD20X11 SUMMARY: The equipment complies with the requirements according to the following standard(s) or Specification: KDB447498 D01 General RF Exposure Guidance v06 FCC Part2.1091, FCC Part2.1093 FCC Part1.1307(b) PREPARED BY: REVIEWED BY: Project Engineer Scout Gong Reviewer Wakeyou Wang Report No.: 210800239HZH-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 3 of 9 Revision History Report No. Version Description Issued Date 210800239HZH-003 Rev. 01 Initial issue of report December 30, 2021 Report No.: 210800239HZH-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 4 of 9 1 GENERAL INFORMATION 1.1 Description of Equipment Under Test (EUT) Product name: LED Floor Light Type/Model: LUM-FLD20X110W08BK-3WF Description of EUT: The EUT is a led lamp for household use, the EUT has the controller box, which is including the Wi-Fi and BLE module. The EUT is powered by adaptor which have two models: AED09- 01200750GQIP20-5 and YN-15WA120075US. The ratting of the adaptor: Input: 100-240VAC, 50/60Hz, 0.25A. Output: 12VDC, 0.75A Max, class 2 circuit output. The worst results were listed in this report as representative. Rating: 120VAC, 50/60Hz, 8W EUT type: Tabletop Floor standing Brand name: Software Version: / Hardware Version: / Sample received date: October 15, 2021 Date of test: October 15, 2021~November 25, 2021 Report No.: 210800239HZH-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 5 of 9 1.2 Technical Specification Wifi Frequency Band: 2400MHz ~ 2483.5MHz Support Standards: IEEE 802.11b, IEEE 802.11g, IEEE 802.11n(HT20), IEEE 802.11n(HT40) Type of Modulation: IEEE 802.11b: DSSS (CCK, DQPSK, DBPSK) IEEE 802.11g: OFDM (64-QAM, 16-QAM, QPSK, BPSK) IEEE 802.11n(HT20): OFDM (64-QAM, 16-QAM, QPSK, BPSK) IEEE 802.11n(HT40): OFDM (64-QAM, 16-QAM, QPSK, BPSK) Channel Number: 11 Channels for 802.11b, 802.11g and 802.11n(HT20) 7 Channels for 802.11n(HT40) Data Rate: IEEE 802.11b: Up to 11Mbps IEEE 802.11g: Up to 54Mbps IEEE 802.11n(HT20): Up to MCS7 IEEE 802.11n(HT40): Up to MCS7 Channel Separation: 5 MHz Antenna Information: PCB Antenna, 2.2dBi Bluetooth Frequency Band: 2400MHz to 2483.5MHz Support Standards: Bluetooth Low Energy Type of Modulation: GFSK Channel Number: 40 (0 ~ 39) Channel Rate: 1Mbps Channel Separation: 2MHz Antenna Information: PCB Antenna, 2.2dBi Report No.: 210800239HZH-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 6 of 9 1.3 Description of Test Facility Name: Intertek Testing Services Shanghai Address: Building 86, No. 1198 Qinzhou Road (North), Shanghai 200233, P.R. China Telephone: 86 21 61278200 Telefax: 86 21 54262353 The test facility is recognized, certified, or accredited by these organizations: CNAS Accreditation Lab Registration No. CNAS L0139 FCC Accredited Lab Designation Number: CN1175 IC Registration Lab CAB identifier.: CN0051 VCCI Registration Lab Registration No.: R-14243, G-10845, C-14723, T-12252 A2LA Accreditation Lab Certificate Number: 3309.02 Report No.: 210800239HZH-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 7 of 9 2 MPE Assessment Test result: Pass 2.1 MPE Assessment Limit Mobile device exposure for standalone operations: Frequency range E-field strength (V/m) H-field strength (A/m) B-field (uT) Equivalent plane wave power density S eq (W/m 2 ) 0-1 Hz - 3,2 × 10 4 4 × 10 4 - 1-8 Hz 10 000 3,2 × 10 4 /f 2 4 × 10 4 /f 2 - 8-25 Hz 10 000 4 000/f 5 000/f - 0,025-0,8 kHz 250/f 4/f 5/f - 0,8-3 kHz 250/f 5 6,25 - 3-150 kHz 87 5 6,25 - 0,15-1 MHz 87 0,73/f 0,92/f - 1-10 MHz 87/f 1/2 0,73/f 0,92/f - 10-400 MHz 28 0,073 0,092 2 400-2 000 MHz 1,375 f 1/2 0,0037 f 1/2 0,0046 f 1/2 f/200 2-300 GHz 61 0,16 0,20 10 Mobile device exposure for simultaneous transmission operations: the sum of the MPE ratios for all simultaneously transmitting antennas incorporated in a host device is ≤ 1.0 Report No.: 210800239HZH-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 8 of 9 2.2 Assessment Results Power density (S) is calculated according to the formula: S = PG / (4πR²) Where S = power density in mW/cm² P = Radiated transmit power in mW G = numeric gain of transmit antenna R = distance (cm) As we can see from the test report 210800239HZH-001&210800239HZH-002: The calculations in the table below use the highest gain of antenna for client EUT. These calculations …

Text truncated - open the document above for the full version.

Test Report

Ningbo Sunpu Led Co Ltd RF TEST REPORT Report Type: FCC Part 15.247 & ISED RSS-247 RF report Model: LUM-FLD20X110W08BK-3WF REPORT NUMBER: 210800239HZH-001 ISSUE DATE: December 30, 2021 DOCUMENT CONTROL NUMBER: TTRF15.247-02_V1 © 2018 Intertek Intertek Testing Services Shanghai Building No.86, 1198 Qinzhou Road (North) Caohejing Development Zone Shanghai 200233, China Telephone: 86 21 6127 8200 www.intertek.com TEST REPORT This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. TTRF15.247-02_V1 © 2018 Intertek Page 2 of 41 Report no. 210800239HZH-001 Applicant: Ningbo Sunpu Led Co Ltd No.150, Xin Hui Road Hi-Tech Park, NINGBO Zhejiang 315040, China. Manufacturer: Ningbo Sunpu Led Co Ltd No.150, Xin Hui Road Hi-Tech Park, NINGBO Zhejiang 315040, China. PRODUCT NAME: LED Floor Light TYPE/MODEL: LUM-FLD20X110W08BK-3WF FCC ID: 2A3ZE-FLD20X11 IC: 27902-FLD20X11 SUMMARY: The equipment complies with the requirements according to the following standard(s) or Specification: 47CFR Part 15 (2020): Radio Frequency Devices (Subpart C) ANSI C63.10 (2013): American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices RSS-247 Issue 2 (February 2017): Digital Transmission Systems (DTSs), Frequency Hopping Systems (FHSs) and Licence-Exempt Local Area Network (LE-LAN) Devices RSS-Gen Issue 5 (March 2019) Amendment 1: General Requirements for Compliance of Radio Apparatus PREPARED BY: REVIEWED BY: Project Engineer Scout Gong Reviewer Wakeyou Wang Report No.: 210800239HZH-001 TEST REPORT TTRF15.247-02_V1 © 2018 Intertek Page 3 of 41 Content REVISION HISTORY................................................................................................................................................ 5 MEASUREMENT RESULT SUMMARY ..................................................................................................................... 6 1 GENERAL INFORMATION ............................................................................................................................. 7 1.1 DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ..................................................................................................... 7 1.2 TECHNICAL SPECIFICATION .................................................................................................................................... 7 1.3 DESCRIPTION OF TEST FACILITY .............................................................................................................................. 8 2 TEST SPECIFICATIONS ................................................................................................................................... 9 2.1 STANDARDS OR SPECIFICATION ............................................................................................................................... 9 2.2 MODE OF OPERATION DURING THE TEST ................................................................................................................... 9 2.3 TEST SOFTWARE LIST .......................................................................................................................................... 10 2.4 TEST PERIPHERALS LIST ....................................................................................................................................... 10 2.5 TEST ENVIRONMENT CONDITION: .......................................................................................................................... 10 2.6 INSTRUMENT LIST .............................................................................................................................................. 11 2.7 MEASUREMENT UNCERTAINTY ............................................................................................................................. 13 3 MINIMUM 6DB BANDWIDTH ..................................................................................................................... 14 3.1 LIMIT .............................................................................................................................................................. 14 3.2 MEASUREMENT PROCEDURE ............................................................................................................................... 14 3.3 TEST CONFIGURATION ........................................................................................................................................ 14 3.4 TEST RESULTS OF MINIMUM 6DB BANDWIDTH ....................................................................................................... 14 4 MAXIMUM CONDUCTED OUTPUT POWER AND E.I.R.P. ............................................................................. 15 4.1 LIMIT .............................................................................................................................................................. 15 4.2 MEASUREMENT PROCEDURE ............................................................................................................................... 15 4.3 TEST CONFIGURATION .....................................................................................…

Text truncated - open the document above for the full version.

Test Report

Ningbo Sunpu Led Co Ltd RF TEST REPORT Report Type: FCC Part 15.247 & ISED RSS-247 RF report Model: LUM-FLD20X110W08BK-3WF REPORT NUMBER: 210800239HZH-002 ISSUE DATE: December 30, 2021 DOCUMENT CONTROL NUMBER: TTRF15.247-03_V1 © 2018 Intertek Intertek Testing Services Shanghai Building No.86, 1198 Qinzhou Road (North) Caohejing Development Zone Shanghai 200233, China Telephone: 86 21 6127 8200 www.intertek.com TEST REPORT This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. TTRF15.247-03_V1 © 2018 Intertek Page 2 of 62 Report no. 210800239HZH-002 Applicant: Ningbo Sunpu Led Co Ltd No.150, Xin Hui Road Hi-Tech Park, NINGBO Zhejiang 315040, China. Manufacturer: Ningbo Sunpu Led Co Ltd No.150, Xin Hui Road Hi-Tech Park, NINGBO Zhejiang 315040, China. PRODUCT NAME: LED Floor Light TYPE/MODEL: LUM-FLD20X110W08BK-3WF FCC ID: 2A3ZE-FLD20X11 IC: 27902-FLD20X11 SUMMARY: The equipment complies with the requirements according to the following standard(s) or Specification: 47CFR Part 15 (2020): Radio Frequency Devices (Subpart C) ANSI C63.10 (2013): American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices RSS-247 Issue 2 (February 2017): Digital Transmission Systems (DTSs), Frequency Hopping Systems (FHSs) and Licence-Exempt Local Area Network (LE-LAN) Devices RSS-Gen Issue 5 (March 2019) Amendment 1: General Requirements for Compliance of Radio Apparatus PREPARED BY: REVIEWED BY: Project Engineer Scout Gong Reviewer Wakeyou Wang Report No.: 210800239HZH-002 TEST REPORT TTRF15.247-03_V1 © 2018 Intertek Page 3 of 62 Content REVISION HISTORY................................................................................................................................................ 5 MEASUREMENT RESULT SUMMARY ..................................................................................................................... 6 1 GENERAL INFORMATION ............................................................................................................................. 7 1.1 DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ..................................................................................................... 7 1.2 TECHNICAL SPECIFICATION .................................................................................................................................... 7 1.3 ANTENNA INFORMATION....................................................................................................................................... 8 1.4 DESCRIPTION OF TEST FACILITY .............................................................................................................................. 9 2 TEST SPECIFICATIONS ................................................................................................................................. 10 2.1 STANDARDS OR SPECIFICATION ............................................................................................................................. 10 2.2 MODE OF OPERATION DURING THE TEST ................................................................................................................. 10 2.3 TEST SOFTWARE LIST .......................................................................................................................................... 11 2.4 TEST PERIPHERALS LIST ....................................................................................................................................... 11 2.5 TEST ENVIRONMENT CONDITION: .......................................................................................................................... 11 2.6 INSTRUMENT LIST .............................................................................................................................................. 12 2.7 MEASUREMENT UNCERTAINTY ............................................................................................................................. 14 3 MINIMUM 6DB BANDWIDTH ..................................................................................................................... 15 3.1 LIMIT .............................................................................................................................................................. 15 3.2 MEASUREMENT PROCEDURE ............................................................................................................................... 15 3.3 TEST CONFIGURATION ........................................................................................................................................ 15 3.4 TEST RESULTS OF MINIMUM 6DB BANDWIDTH ....................................................................................................... 15 4 MAXIMUM CONDUCTED OUTPUT POWER AND E.I.R.P. ............................................................................. 16 4.1 LIMIT .............................................................................................................................................................. 16 4.2 MEASUREMENT PROCEDURE .................................................................................…

Text truncated - open the document above for the full version.

Test Report

Report No.: 210800239HZH-002 TEST REPORT TTRF15.247-03_V1 © 2018 Intertek Page 51 of 62 802.11g 2462 Ant0 2 Band Edge -50.06 Pass 802.11g 2462 Ant0 3 30MHz~2310MHz -54.40 Pass 802.11g 2462 Ant0 4 2500MHz~5000MHz -54.78 Pass 802.11g 2462 Ant0 5 5000MHz~25000MHz -41.85 Pass 802.11n (HT20) 2412 Ant0 1 Reference Level 2.08 Pass 802.11n (HT20) 2412 Ant0 2 Band Edge -43.89 Pass 802.11n (HT20) 2412 Ant0 3 30MHz~2310MHz -56.06 Pass 802.11n (HT20) 2412 Ant0 4 2500MHz~5000MHz -54.92 Pass 802.11n (HT20) 2412 Ant0 5 5000MHz~25000MHz -42.21 Pass 802.11n (HT20) 2437 Ant0 1 Reference Level 2.41 Pass 802.11n (HT20) 2437 Ant0 2 Band Edge -51.32 Pass 802.11n (HT20) 2437 Ant0 3 30MHz~2310MHz -55.42 Pass 802.11n (HT20) 2437 Ant0 4 2500MHz~5000MHz -54.66 Pass 802.11n (HT20) 2437 Ant0 5 5000MHz~25000MHz -41.81 Pass 802.11n (HT20) 2462 Ant0 1 Reference Level 1.20 Pass 802.11n (HT20) 2462 Ant0 2 Band Edge -49.34 Pass 802.11n (HT20) 2462 Ant0 3 30MHz~2310MHz -56.34 Pass 802.11n (HT20) 2462 Ant0 4 2500MHz~5000MHz -55.04 Pass 802.11n (HT20) 2462 Ant0 5 5000MHz~25000MHz -42.19 Pass 802.11n (HT40) 2422 Ant0 1 Reference Level -3.81 Pass 802.11n (HT40) 2422 Ant0 2 Band Edge -42.43 Pass 802.11n (HT40) 2422 Ant0 3 30MHz~2310MHz -52.50 Pass 802.11n (HT40) 2422 Ant0 4 2500MHz~5000MHz -53.23 Pass 802.11n (HT40) 2422 Ant0 5 5000MHz~25000MHz -42.15 Pass 802.11n (HT40) 2437 Ant0 1 Reference Level -4.16 Pass 802.11n (HT40) 2437 Ant0 2 Band Edge -49.30 Pass 802.11n (HT40) 2437 Ant0 3 30MHz~2310MHz -51.12 Pass 802.11n (HT40) 2437 Ant0 4 2500MHz~5000MHz -52.77 Pass Report No.: 210800239HZH-002 TEST REPORT TTRF15.247-03_V1 © 2018 Intertek Page 52 of 62 802.11n (HT40) 2437 Ant0 5 5000MHz~25000MHz -41.94 Pass 802.11n (HT40) 2452 Ant0 1 Reference Level -4.96 Pass 802.11n (HT40) 2452 Ant0 2 Band Edge -45.82 Pass 802.11n (HT40) 2452 Ant0 3 30MHz~2310MHz -52.63 Pass 802.11n (HT40) 2452 Ant0 4 2500MHz~5000MHz -53.22 Pass 802.11n (HT40) 2452 Ant0 5 5000MHz~25000MHz -41.90 Pass Report No.: 210800239HZH-002 TEST REPORT TTRF15.247-03_V1 © 2018 Intertek Page 53 of 62 Test Plots 802.11b,2412MHz,Ant0,Plot 1,Reference Level 802.11b,2412MHz,Ant0,Plot 2,Band Edge 802.11b,2412MHz,Ant0,Plot 3,30MHz~231 0MHz 802.11b,2412MHz,Ant0,Plot 4,2500MHz~5 000MHz 802.11b,2412MHz,Ant0,Plot 5,5000MHz~2 5000MHz 802.11b,2437MHz,Ant0,Plot 1,Reference Level Report No.: 210800239HZH-002 TEST REPORT TTRF15.247-03_V1 © 2018 Intertek Page 54 of 62 802.11b,2437MHz,Ant0,Plot 2,Band Edge 802.11b,2437MHz,Ant0,Plot 3,30MHz~231 0MHz 802.11b,2437MHz,Ant0,Plot 4,2500MHz~5 000MHz 802.11b,2437MHz,Ant0,Plot 5,5000MHz~2 5000MHz 802.11b,2462MHz,Ant0,Plot 1,Reference Level 802.11b,2462MHz,Ant0,Plot 2,Band Edge Report No.: 210800239HZH-002 TEST REPORT TTRF15.247-03_V1 © 2018 Intertek Page 55 of 62 802.11b,2462MHz,Ant0,Plot 3,30MHz~231 0MHz 802.11b,2462MHz,Ant0,Plot 4,2500MHz~5 000MHz 802.11b,2462MHz,Ant0,Plot 5,5000MHz~2 5000MHz 802.11g,2412MHz,Ant0,Plot 1,Reference Level 802.11g,2412MHz,Ant0,Plot 2,Band Edge 802.11g,2412MHz,Ant0,Plot 3,30MHz~231 0MHz Report No.: 210800239HZH-002 TEST REPORT TTRF15.247-03_V1 © 2018 Intertek Page 56 of 62 802.11g,2412MHz,Ant0,Plot 4,2500MHz~5 000MHz 802.11g,2412MHz,Ant0,Plot 5,5000MHz~2 5000MHz 802.11g,2437MHz,Ant0,Plot 1,Reference Level 802.11g,2437MHz,Ant0,Plot 2,Band Edge 802.11g,2437MHz,Ant0,Plot 3,30MHz~231 0MHz 802.11g,2437MHz,Ant0,Plot 4,2500MHz~5 000MHz Report No.: 210800239HZH-002 TEST REPORT TTRF15.247-03_V1 © 2018 Intertek Page 57 of 62 802.11g,2437MHz,Ant0,Plot 5,5000MHz~2 5000MHz 802.11g,2462MHz,Ant0,Plot 1,Reference Level 802.11g,2462MHz,Ant0,Plot 2,Band Edge 802.11g,2462MHz,Ant0,Plot 3,30MHz~231 0MHz 802.11g,2462MHz,Ant0,Plot 4,2500MHz~5 000MHz 802.11g,2462MHz,Ant0,Plot 5,5000MHz~2 5000MHz Report No.: 210800239HZH-002 TEST REPORT TTRF15.247-03_V1 © 2018 Intertek Page 58 of 62 802.11n(HT20),2412MHz,Ant0,Plot 1,Reference Level 802.11n(HT20),2412MHz,Ant0,Plot 2,Band Edge 802.11n(HT20),2412MHz,Ant0,Plot 3,30MHz~2310MHz 802.11n(HT20),2412MHz,Ant0,Plot 4,2500MHz~5000MHz 802.11n(HT20),2412MHz,Ant0,Plot 5,5000MHz~25000MHz 802.11n(HT20),2437MHz,Ant0,Plot 1,Reference Level Report No.: 210800239HZH-002 TEST REPORT TTRF15.247-03_V1 © 2018 Intertek Page 59 of 62 802.11n(HT20),2437MHz,Ant0,Plot 2,Band Edge 802.11n(HT20),2437MHz,Ant0,Plot 3,30MHz~2310MHz 802.11n(HT20),2437MHz,Ant0,Plot 4,2500MHz~5000MHz 802.11n(HT20),2437MHz,Ant0,Plot 5,5000MHz~25000MHz 802.11n(HT20),2462MHz,Ant0,Plot 1,Reference Level 802.11n(HT20),2462MHz,Ant0,Plot 2,Band Edge Report No.: 210800239HZH-002 TEST REPORT TTRF15.247-03_V1 © 2018 Intertek Page 60 of 62 802.11n(HT20),2462MHz,Ant0,Plot 3,30MHz~2310MHz 802.11n(HT20),2462MHz,Ant0,Plot 4,2500MHz~5000MHz 802.11n(HT20),2462MHz,Ant0,Plot 5,5000MHz~25000MHz 802.11n(HT40),2422MHz,Ant0,Plot 1,Reference Level 802.11n(HT40),2422MHz,Ant0,Plot 2,Band Edge 802.11n(HT40),2422MHz,Ant0,Plot 3,30MHz~2310MHz Report No.: 210800239HZH-002 TEST REPORT TTRF15.247-03_V1 © 2018 Intertek Page 61 of 62 802.11n(HT40),2422MHz,Ant0,Plot 4,2500MHz~5000MHz 802.11n(HT40),2422MHz,Ant0,Plot 5,5000MHz~25000MHz 802.11n(HT40),2437MHz,Ant0,Plot 1,Reference Level 802.11n(HT40),2437MHz,Ant0,Plot 2,Band Edge 802.11n(HT40),2437MHz,Ant0,Plot 3,30MHz~2310MHz 802.11n(HT40),2437MHz,Ant0,Plot 4,2500MHz~5000MHz Report No.: 210800239HZH-002 TEST REPORT TTRF15.247-03_V1 © 2018 Intertek Page 62 of 62 802.11n(HT40),2437MHz,Ant0,Plot 5,5000MHz~25000MHz 802.11n(HT40),2452MHz,Ant0,Plot 1,Reference Level 802.11n(HT40),2452MHz,Ant0,Plot 2,Band Edge 802.11n(HT40),2452MHz,Ant0,Plot 3,30MHz~2310MHz 802.11n(HT40),2452MHz,Ant0,Plot 4,2500MHz~5000MHz 802.11n(HT40),2452MHz,Ant0,Plot 5,5000MHz~25000MHz **************************************** END ***************************************

Test Setup Photos

Page 1 of 3 Test Setup Page 2 of 3 1.Conducted Emission 2. Radiated Emission Page 3 of 3 3. Conducted RF test

Contact Information

Applicant

HongQiang Niu(Engineer)
[email protected]13615887592Fax: +8657487901518

Technical Contact

Intertek Testing Services ShanghaiScout Gong
[email protected]86 21 61215125

Building No.86, 1198 Qinzhou Road(North) · Shanghai · China

Non-Technical Contact

Intertek Testing Services ShanghaiScout Gong
[email protected]86 21 61215125

Test Firm

Intertek Testing Services ShanghaiLeah Xu
[email protected]+86 21 61278200

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.40 GHz - 2.48 GHz2.40 mW
Confidentiality
Long Term
Grant Notes
Power Output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20 MHz and 40 MHz bandwidth modes.