Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Dec 04, 2025
Application Purpose
Original Equipment
Equipment Note
Rechargeable OTC Hearing Aids
Frequency Range
2402.00000000 - 2480.00000000
Company
Austar Hearing Science and Technology (Xiamen) Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

UserManual Warnings WARNING:Ifyouareyoungerthan18,donotusethis. Youshouldgotoadoctor,preferablyanear-nose-throatdoctor(anENT),because yourconditionneedsspecializedcare.Over-the-counterhearingaidsareonlyfor userswhoareage18orolder. Thisisforuserswhoare18andolder.Peoplewhoareyoungerthan 18withhearinglossshouldseeadoctor,preferablyanENT,becausetheymayneed medicaltestingandmanagement.Hearinglosscanaffectspeechandlearning,so professionalfittingandcontinuingcarearealsoimportant. WARNING:WhentoSeeaDoctor Ifyouhaveanyoftheproblemslistedbelow,pleaseseeadoctor,preferablyan ear-nose-throatdoctor(anENT). · Yourearhasabirthdefectoranunusualshape.Yourearwasinjuredordeformed inanaccident. · Yousawblood,pus,orfluidcomingoutofyourearinthepast6monthsYourear feelspainfuloruncomfortable. · Yourearfeelspainfuloruncomfortable. · Youhavealotofearwax,oryouthinksomethingcouldbeinyourear. · Yougetreallydizzyorhaveafeelingofspinningorswaying(calledvertigo). · Yourhearingchangedsuddenlyinthepast6months. · Yourhearingchanges:itgetsworsethengetsbetteragain. · Youhaveworsehearinginoneear. · Youhearringingorbuzzinginonlyoneear. WARNING:This shouldnotcausepainwheninsertingit. Removethisdevicefromyourearifitcausespainordiscomfortwhenyouinsertor placeit.Totryagain,makesuretofollowtheinstructions.Ifyoufeelpainor discomfortagain,contactthemanufacturer.Ifyourpainordiscomfortdoesn'tgo away,contactyourhearinghealthcareprofessional.YoucanalsoreportthistoFDA asanadverseeventaccordingtotheinstructionsthatappearlater. ThesePRECAUTIONSpointoutsituationswhichcouldcauseminorormoderate injuriestotheuserortothehearingaid. Rechargeable OTC Hearing Aids Rechargeable OTC Hearing Aids · Youshouldfamiliarizeyourselffullywiththeentirecontentsofthisusermanual beforeusingthehearingaidtoensurepersonalsafetyandcorrectuse.Contact themanufacturerforsupportifyouexperienceunexpectedoperationsor performance. · Donotattempttomodifytheshapeoftheor slimtubeyourself. TheseWARNINGSpointoutsituationswhichcouldcauseseriousinjuriestothe userortothehearingaid. · Insomeacousticenvironments,overamplificationcancausediscomfortanddamage tothepatient’shearing. · Ahearingaidshouldonlybeusedasdirectedbyyourphysicianorhearing healthcareprovider. · Donotuseyour inexplosiveoroxygen-enrichedareas.Allergic reactionsto areunlikely.However,ifyouexperienceitching, redness,soreness,inflammation,oraburningsensationinoraroundyourears, informyourhearinghealthcareproviderandcontactyourphysician. · Youmaynoticeacceleratedaccumulationofearwaxwhenusingyour Thisisnormal,butseeyourhearinghealthcareproviderifyoucontinuetohave difficulty. · Intheunlikelycasethatanypartsremainintheearcanalaftertheremovalofthe hearingaid,contactaphysicianimmediately.Reporttheeventtoyourhearing healthcareproviderassoonaspossible. · RemoveyouraidsforCTandMRIscansorforotherelectromagneticprocedures. · Neverleaveyourhearingaidsorbatterieswheresmallchildrenandpetscanreach them.Ifbatteriesareswallowedorinhaled,contactthelocalpoisoncontrolcenter immediately. · Ifyoufeelpaininorbehindyourear,ifitisinflamed,ifskinirritationor accumulationsofearwaxoccur,pleasecheckwithyourhearinghealthcare providerorphysician. · Yourhearingaidshavebeenadjustedforyourhearingneeds;pleasedonotshare yourhearingdevicewithotherpeople. Cautionandnoticesforusers Caution:Thisisnothearingprotection. Youshouldremovethisdeviceifyouexperienceoverlyloudsounds,whethershort orlong-lasting.Ifyou'reinaloudplace,youshouldusetherightkindofhearing protectioninsteadofwearingthisdevice.Ingeneral,ifyouwoulduseearplugsina loudplace,youshouldremovethisdeviceanduseearplugs. Caution:Thesoundoutputshouldnotbeuncomfortableorpainful Youshouldturndownthevolumeorremovethedeviceifthesoundoutputis uncomfortablyloudorpainful.Ifyouconsistentlyneedtoturnthevolumedown, youmayneedtofurtheradjustyourdevice. Rechargeable OTC Hearing Aids Rechargeable OTC Hearing Aids Rechargeable OTC Hearing Aids Rechargeable OTC Hearing Aids. Caution:Youmightneedmedicalhelpifapiecegetsstuckinyourear. Ifanypartofyourhearingaid,liketheeartip,getsstuckinyourear,andyoucan't easilyremoveitwithyourfingers,getmedicalhelpassoonasyoucan.Youshould nottrytousetweezersorcottonswabsbecausetheycanpushthepartfartherinto yourear,injuringyoureardrumorearcanal,possiblyseriously. Note:Ifyouremainconcerned,consultwithaprofessional. Ifyoutrythisdeviceandcontinuetostrugglewithorremainconcernedaboutyour hearing,youshouldconsultwithahearinghealthcareprofessional. Note:WhatyoumightexpectwhenyoustartusingaRechargeable Ahearingaidcanbenefitmanypeoplewithhearingloss.However,youshould knowitwillnotrestorenormalhearing,andyoumaystillhavesomedifficulty hearingovernoise.Further,ahearingaidwillnotpreventorimproveamedical conditionthatcauseshearingloss. Peoplewhostartusinghearingaidssometimesneedafewweekstogetusedto them.Similarly,manypeoplefindthattrainingorcounselingcanhelpthemget moreoutoftheirdevices. Ifyouhavehearinglossinbothears,youmightgetmoreoutofusinghearingaids inboth,especiallyinsituationsthatmakeyoutiredfromlistening-forexample, noisyenvironments. Note:TellFDAaboutinjuries,malfunctions,orotheradverseevents. Toreportaprobleminvolvingyourhearingaid,youshouldsubmitinformationto FDAassoonaspossibleaftertheproblem.FDAcallsthem"adverseevents,"and theymightinclude:skinirritationinyourear,injuryfromthedevice(likecutsor scratches,orburnsfromanoverheatedbattery),piecesofthedevicegettingstuck inyourear,suddenlyworseninghearinglossfromusingthedevice,etc. Instructionsforreportingareavailableathttps://www.fda.gov/Safety/MedWatch,or call1-800-FDA-1088.YoucanalsodownloadaformtomailtoFDA. Dearcustomer: Thankyouforchoosingour Thehearingaidisaverysophisticatedelectronicequipmentwhichisusedforhearing compensationfortheonewhohashearingimpaired. Thismanualwillintroduceyousomebasicusemethodsofhearingaidandthe solutionsofcommonproblemstohelpyouusehearingaidbetter.Pleasereadit carefullyandregarditasauserguide. Withanyquestion,pleasebefreetocontactthecustomerservicecenter. OTC HearingAids. Rechargeable OTC Hearing Aids! 1.Overview Th…

Text truncated - open the document above for the full version.

Attestation Statements

Austar Hearing Science and Technology (Xiamen) Co., Ltd. Add: B8, Biomedical Industrial Park, No.2064 Wengjiao West Road, Haicang Dist. Xiamen, Fujian, China Tel: +86-18650110816 Fax: +86-0592-5970067 E-mail: [email protected] Attestation Letter Date: 08/22/2025 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(i)(ii) Filing FCC ID: 2A445FAX916-B-R Austar Hearing Science and Technology (Xiamen) Co., Ltd. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Austar Hearing Science and Technology (Xiamen) Co., Ltd. (“the applicant”) certifies that as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Austar Hearing Science and Technology (Xiamen) Co., Ltd. (“the applicant”) certifies that our product does not use Kaspersky's software information. Sincerely, Signature Contact Person: Ula Yang Title: RA Engineer

Attestation Statements

U.S. AGENT LETTER OF ATTESTATION Date: 2025-08-22 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(7) Filing FCC ID: 2A445FAX916-B-R Austar Hearing Science and Technology (Xiamen) Co., Ltd., Limited certifies that, as of the date of the filing of the application, Iconsigh Inc. is our designated U.S. agent for service of process for the above referenced FCC ID. Austar Hearing Science and Technology (Xiamen) Co., Ltd. accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Iconsigh Inc. accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Company Name: Iconsigh Inc. Address: 2310 Homestead Road, Suite C1, Los Altos, CA, 94024, USA FRN: 0033398652 Tel.: +1 (408) 320-9867 Email: [email protected] Signed by (printed name): Benjamin Kaur Signature: Applicant: Austar Hearing Science and Technology (Xiamen) Co., Ltd. Address: B8, Biomedical Industrial Park, No.2064 Wengjiao West Road, Haicang Dist. Xiamen, Fujian, China FRN: 0031993454 Tel: +86-18650110816 Email: [email protected] Signed by (printed name): Ula Yang Signature:

Attestation Statements

Austar Hearing Science and Technology (Xiamen) Co., Ltd. Add: B8, Biomedical Industrial Park, No.2064 Wengjiao West Road, Haicang Dist. Xiamen, Fujian, China Tel: +86-18650110816 Fax: +86-0592-5970067 E-mail: [email protected] Date: 2025-08-22 To: FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Dear Sir/Madam, We, Austar Hearing Science and Technology (Xiamen) Co., Ltd., hereby authorize Bay Area Compliance Laboratories Corp. (Xiamen) to act as a laboratory for testing and test report generation for the following project(s): (Product name: Rechargeable OTC Hearing Aids, Model Name: FAX916-B, Atom X, FCC ID: 2A445FAX916-B-R) The product only supports BT(GFSK, π/4-DQPSK, 8DPSK),BLE 1M, 2M(GFSK), other functions has been shielded by software, and end user cannot activate them. Sincerely, Signature: Printed name: Ula Yang Title: RA Engineer

Cover Letter(s)

QA-FR-170-B Austar Hearing Science and Technology (Xiamen) Co., Ltd. Add: B8, Biomedical Industrial Park, No.2064 Wengjiao West Road, Haicang Dist. Xiamen, Fujian, China Tel: +86-18650110816 Fax: +86-0592-5970067 E-mail: [email protected] FCC Authorization Date: 2025-08-22 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We , Austar Hearing Science and Technology (Xiamen) Co., Ltd., Hereby authorizes Bay Area Compliance Laboratories Corp. (Xiamen) to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratories Corp. (Xiamen) on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Client’s signature Contact Person: Ula Yang Title: RA Engineer

Cover Letter(s)

QA-FR-171-A Austar Hearing Science and Technology (Xiamen) Co., Ltd. Add: B8, Biomedical Industrial Park, No.2064 Wengjiao West Road, Haicang Dist. Xiamen, Fujian, China Tel: +86-18650110816 Fax: +86-0592-5970067 E-mail: [email protected] FCC Confidential Authorization Date: 2025-08-22 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: 2A445FAX916-B-R In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Austar Hearing Science and Technology (Xiamen) Co., Ltd. hereby requests long-term confidential treatment of information accompanying this application as outlined below:  Block Diagram  Schematics  Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely, Signature: Contact Person: Ula Yang Title: RA Engineer

Cover Letter(s)

Austar Hearing Science and Technology (Xiamen) Co., Ltd. Add: B8, Biomedical Industrial Park, No.2064 Wengjiao West Road, Haicang Dist. Xiamen, Fujian, China Tel: +86-18650110816 Fax: +86-0592-5970067 E-mail: [email protected] DECLARATION OF SIMILARITY Date: 2025-07-22 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Dear Sir or Madam: We, Austar Hearing Science and Technology (Xiamen) Co., Ltd., hereby declare that the product: Rechargeable OTC Hearing Aids, model: Atom X are electrically identical with the model: FAX916-B which was tested by Bay Area Compliance Laboratories Corp. (Xiamen) with the same electromagnetic emissions and electromagnetic compatibility characteristics. A description of the differences between those models and that are declared similar are as follows: They are the same product, just different model name, the rest are the same. Please contact me should there be need for any additional clarification or information. Best Regards, Signature: Printed name: Ula Yang Title: RA Engineer

Cover Letter(s)

QA-FR-169-B Austar Hearing Science and Technology (Xiamen) Co., Ltd. Add: B8, Biomedical Industrial Park, No.2064 Wengjiao West Road, Haicang Dist. Xiamen, Fujian, China Tel: +86-18650110816 Fax: +86-0592-5970067 E-mail: [email protected] To FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia,MD 21046 Dear Sir/Madam, We, Austar Hearing Science and Technology (Xiamen) Co., Ltd., hereby submits justification for placing the FCC ID label to the charging box. According to the FCC Regulation and Guidence (KDB Publication 784748 D01 v09R01) allows for the FCC to be removed to charging box if the device is unquestionably too small for the FCC ID label to be printed. The measurement of headset: Length (16.25mm)*Width (11.27mm)*High (27.42mm), charging box label: (22.5mm)*Width (18.6mm), charging box:72.1(mm)*53.1 (mm)*25.4(mm). Refer to the above quote, as the headset are too small for the FCC ID label to be printed, so the FCC ID label will be moved to the charging box. For details, please see below photos: Headset size and photo: Charging box size and photo: Label: QA-FR-169-B Sincerely, Printed Name: Ula Yang Title: RA Engineer

External Photos

Bay Area Compliance Laboratories Corp. (Xiamen) Report No.: 2507V00610E-RF-EXP Page 1 / 6 EUT EXTERNAL PHOTOS FAX916-B Bay Area Compliance Laboratories Corp. (Xiamen) Report No.: 2507V00610E-RF-EXP Page 2 / 6 Bay Area Compliance Laboratories Corp. (Xiamen) Report No.: 2507V00610E-RF-EXP Page 3 / 6 Bay Area Compliance Laboratories Corp. (Xiamen) Report No.: 2507V00610E-RF-EXP Page 4 / 6 Atom X Bay Area Compliance Laboratories Corp. (Xiamen) Report No.: 2507V00610E-RF-EXP Page 5 / 6 Bay Area Compliance Laboratories Corp. (Xiamen) Report No.: 2507V00610E-RF-EXP Page 6 / 6

Internal Photos

Bay Area Compliance Laboratories Corp. (Xiamen) Report No.: 2507V00610E-RF-INP Page 1 / 3 EUT INTERNAL PHOTOS Antenna Bay Area Compliance Laboratories Corp. (Xiamen) Report No.: 2507V00610E-RF-INP Page 2 / 3 Bay Area Compliance Laboratories Corp. (Xiamen) Report No.: 2507V00610E-RF-INP Page 3 / 3

RF Exposure Info

RF EXPOSURE REPORT For Austar Hearing Science and Technology (Xiamen) Co., Ltd. B8, Biomedical Industrial Park, No.2064 Wengjiao West Road, Haicang Dist. Xiamen, Fujian, China FCC ID: 2A445FAX916-B-R Report Type: Original Report Product Name: Rechargeable OTC Hearing Aids Report Number: 2507V00610E-RF-03 Re port Date: 2025-08-08 Reviewed By: Ash Lin Approved By: Miles Chen Prepared By: Ba y Area Compliance Laboratories Corp. (Xiamen) Unit 102, No. 902 Meifeng South Road, Binhai West Avenue, Science and Technology Innovation Park, Torch High tech Zone XiaMen Tel: +86-592-3200111 www.baclcorp.com.cn Bay Area Compliance Laboratories Corp. (Xiamen) Report No.: 2507V00610E-RF-03 Page 2 of 7 TABLE OF CONTENTS REPORT REVISION HISTORY................................................................................................................................. 3 GENERAL INFORMATION ....................................................................................................................................... 4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 4 RF EXPOSURE EVALUATION ................................................................................................................................. 5 EUT PHOTOGRAPHS ................................................................................................................................................. 6 Bay Area Compliance Laboratories Corp. (Xiamen) Report No.: 2507V00610E-RF-03 Page 3 of 7 REPORT REVISION HISTORY Number of Revisions Report No. Version Issue Date Description 0 2507V00610E-RF-03 R1V1 2025-08-08 Initial Release Bay Area Compliance Laboratories Corp. (Xiamen) Report No.: 2507V00610E-RF-03 Page 4 of 7 GENERAL INFORMATION Product Description for Equipment under Test (EUT) Product Name: Rechargeable OTC Hearing Aids Tested Model: FAX916-B Multiple Model(s): Atom X Trade mark: Power Supply: DC 3.7V from battery Maximum Conducted Peak Output Power: Classic BT: 4.54dBm BLE: 2.81dBm Frequency Range: 2402-2480MHz Modulation Technique: Classic BT: GFSK, π/4-DQPSK, 8DPSK BLE: GFSK Antenna Type: FPC Antenna ★Maximum Antenna Gain: 2.69dBi EUT Received Status: Good Note: 1. The Maximum Antenna Gain was declared by manufacturer. 2. The test model is identify with the series model except for the model name, please refer to declaration letter for more detail. 3. The EUT supplied by the applicant was received on 2025-07-17 Objective This test report is prepared for Austar Hearing Science and Technology (Xiamen) Co., Ltd. in accordance with Part 2-Subpart J, Part 15-Subparts A and C of the Federal Communication Commissions rules. Test Facility The Test site used by Bay Area Compliance Laboratories Corp. (Xiamen) to collect test data is located on the Unit 102, No. 902 Meifeng South Road, Binhai West Avenue, Science and Technology Innovation Park, Torch High tech Zone XiaMen. Bay Area Compliance Laboratories Corp. (Xiamen) Lab is accredited to ISO/IEC 17025 by A2LA (Certificate Number: 7134.01) and the lab has been recognized as the FCC accredited lab under the KDB 974614 D01, the FCC Designation No. : CN1384. Bay Area Compliance Laboratories Corp. (Xiamen) Report No.: 2507V00610E-RF-03 Page 5 of 7 RF EXPOSURE EVALUATION Applicable Standard According to§2.1093, systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission's guideline According to KDB447498 D01 General RF Exposure Guidance v06 The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances < 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] - [√f(GHz)] < 3.0 for 1-g SAR and < 7.5 for 10-g extremity SAR, where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is <5 mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion. Measurement Result For BT: The max conducted power including tune-up tolerance is 5 dBm (3.16 mW). [(max. power of channel, mW)/(min. test separation distance, mm)][√f(GHz)] =3.16/5*(√2.480) = 1.0< 3.0 For BLE: The max conducted power including tune-up tolerance is 3 dBm (2 mW). [(max. power of channel, mW)/(min. test separation distance, mm)][√f(GHz)] =2/5*(√2.480) = 0.6< 3.0 Result: Compliant. The stand-alone SAR evaluation is not necessary Bay Area Compliance Laboratories Corp. (Xiamen) Report No.: 2507V00610E-RF-03 Page 6 of 7 EUT PHOTOGRAPHS Please refer to the attachment 2507V00610E-RF-EXP EUT EXTERNAL PHOTOGRAPHS and 2507V00610E-RF-INP EUT INTERNAL PHOTOGRAPHS. Bay Area Compliance Laboratories Corp. (Xiamen) Report No.: 2507V00610E-RF-03 Page 7 of 7 Declarations 1. Bay Area Compliance Laboratories Corp. (Xiamen) is not responsible for authenticity of any information provided by the applicant. Information from the applicant that may affect test results are marked with an asterisk “★”. 2. Unless otherwise stated, the results shown in this test report refer only to the sample(s) tested. 3. Unless required by the rule provided by the applicant or product regulations, then decision rule in this report did not consider the uncertainty. 4. The extended uncertainty given in this report is obtained by combining the standard uncertainty times the coverage factor k=2 with the 95% confidence interval. 5. This report cannot be reproduced except in full, without prior written approval of Bay Area Compl…

Text truncated - open the document above for the full version.

Test Report

FCC PART 15.247 TEST REPORT For Austar Hearing Science and Technology (Xiamen) Co., Ltd. B8, Bio medical Industrial Park, No.2064 Wengjiao West Road, Haicang Dist. Xiamen, Fujian, China FCC ID: 2A445FAX916-B-R R eport Type: Original Report Product Name: Rechargeable OTC Hearing Aids Re port Number: 2507V00610E-RF-02 Re port Date: 2025-08-07 Reviewed By: Ash Lin Approved By: Miles Chen Prepared By : Bay Area Compliance Laboratories Corp. (Xiamen) Unit 102, No. 902 Meifeng South Road, Binhai West Avenue, Science and Technology Innovation Park, Torch High tech Zone XiaMen Tel: +86-592-3200111 www.baclcorp.com.cn Bay Area Compliance Laboratories Corp. (Xiamen) Report No.: 2507V00610E-RF-02 FCC Part 15.247 Page 2 of 72 TABLE OF CONTENTS REPORT REVISION HISTORY ................................................................................................................................ 4 GENERAL INFORMATION ....................................................................................................................................... 5 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 5 OBJECTIVE ................................................................................................................................................................... 5 TEST METHODOLOGY .................................................................................................................................................. 5 MEASUREMENT UNCERTAINTY .................................................................................................................................... 6 SYSTEM TEST CONFIGURATION .......................................................................................................................... 7 TEST MODE AND VOLTAGE .......................................................................................................................................... 7 DESCRIPTION OF TEST CONFIGURATION ...................................................................................................................... 7 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 7 ★EUT EXERCISE SOFTWARE ...................................................................................................................................... 8 DUTY CYCLE ............................................................................................................................................................... 8 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 9 EXTERNAL I/O CABLE ................................................................................................................................................. 9 BLOCK DIAGRAM OF TEST SETUP .............................................................................................................................. 10 SUMMARY OF TEST RESULTS ............................................................................................................................. 12 TEST EQUIPMENT LIST ......................................................................................................................................... 13 FCC §15.203 - ANTENNA REQUIREMENT .......................................................................................................... 14 APPLICABLE STANDARD ............................................................................................................................................ 14 ANTENNA CONNECTOR CONSTRUCTION .................................................................................................................... 14 FCC §15.207 (a) – AC LINE CONDUCTED EMISSIONS ..................................................................................... 15 APPLICABLE STANDARD ............................................................................................................................................ 15 EUT SETUP ................................................................................................................................................................ 15 EMI TEST RECEIVER SETUP ....................................................................................................................................... 15 TEST PROCEDURE ...................................................................................................................................................... 15 RESULT &MARGIN CALCULATION ............................................................................................................................. 16 TEST DATA ................................................................................................................................................................ 16 FCC §15.209, §15.205 - SPURIOUS EMISSIONS .................................................................................................... 17 APPLICABLE STANDARD ............................................................................................................................................ 17 EUT SETUP ................................................................................................................................................................ 17 EMI TEST RECEIVER & SPECTRUM ANALYZER SETUP .............................................................................................. 18 RESULT &MARGIN CALCULATION ............................................................................................................................. 19 TEST DATA ................................................................................................................................................................ 2…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 4 9/2/2025 Antenna Specification 1. Antenna Description: Antenna 2.4G BT Antenna Max. Antenna Gain 2.69 dBi Frequency Range 2402-2480MHz Manufacturer Austar Hearing Science and Technology (Xiamen) Co., Ltd. Address B8, Biomedical Industrial Park, No.2064 Wengjiao West Road, Haicang Dist. Xiamen, Fujian, China Page 2 of 4 9/2/2025 2 Antenna Picture: Page 3 of 4 9/2/2025 3 Antenna Pattern: phi=0º,theta=0º Frequency: 2402MHz, Gain: 1.93dBi phi=0º,theta=0º, Frequency: 2441MHz, Gain; 2.69dBi Page 4 of 4 9/2/2025 phi=0º,theta=0º, Frequency: 2480MHz, Gain; 2.21dBi

Test Setup Photos

Bay Area Compliance Laboratories Corp. (Xiamen) Report No.: 2507V00610E-RF-TSP Page 1 / 4 EUT SETUP PHOTOS RE (9kHz~30MHz) RE – Front View (30MHz~1GHz) Bay Area Compliance Laboratories Corp. (Xiamen) Report No.: 2507V00610E-RF-TSP Page 2 / 4 RE – Back View (30MHz~1GHz) RE – Back View (1 GHz~18 GHz) Bay Area Compliance Laboratories Corp. (Xiamen) Report No.: 2507V00610E-RF-TSP Page 3 / 4 RE – Rear View (1 GHz~18 GHz) RE – Front View (Above 18 GHz) Bay Area Compliance Laboratories Corp. (Xiamen) Report No.: 2507V00610E-RF-TSP Page 4 / 4 RE – Rear View (Above 18 GHz)

Contact Information

Applicant

Ula Yang(RA Engineer)
[email protected]Fax: +86-0592-5970067

Test Firm

Bay Area Compliance Laboratories Corp.(Xiamen)Mike Tu
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.

Other Applications from Austar Hearing Science and Technology (Xiamen) Co., Ltd.

Rechargeable OTC Hearing Aids - FCC ID 2A445FAX916-B-L - Austar Hearing Science and Technology (Xiamen) Co., Ltd.
2A445FAX916-B-L

Rechargeable OTC Hearing Aids

Dec 04, 2025

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Rechargeable OTC Hearing Aids - FCC ID 2A445FAX916-B-C - Austar Hearing Science and Technology (Xiamen) Co., Ltd.
2A445FAX916-B-C

Rechargeable OTC Hearing Aids

Dec 04, 2025

Equipment Class

DTS - Digital Transmission System