FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Fujian Ronghao Fitness Equipment Co.,Ltd./
  3. 2A45X-HM-001

2A45X-HM-001Massage chair

Fujian Ronghao Fitness Equipment Co.,Ltd.
Massage chair - FCC ID 2A45X-HM-001 - Fujian Ronghao Fitness Equipment Co.,Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 16, 2026
Application Purpose
Original Equipment
Equipment Note
Massage chair
Frequency Range
2402.00000000 - 2480.00000000
Company
Fujian Ronghao Fitness Equipment Co.,Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC WARNING This device complies with part 15 of the FCC Rules. Operation is subject to the follow ing two conditions : (1) this device may not cause harmful interference, and (2) this device must accept any interference received, inc luding interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residentia l installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or televis ion reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technic ian for help. To maintain compliance with FCC’s RF Exposure guidelines, This equipment should be insta lled and operated with minimum distance between 20cm the radiator your body: Use only the supplied antenna.

Attestation Statements

FujianRonghaoFitnessEquipmentCo.,Ltd. Code00018768Ed. 2 Item 1.The deviceis able to install software/programinstallation? ☐Yes, go to Item 2. ☒No. In this case, the rest of the items do not apply.The devicecannotsupport installationof Kasperskycybersecurityor anti-virussoftware. Item 2.TechnicalRequirementsfor KasperskyCybersecuritySoftware: #GeneralRequirements(For all Devices)Yes / No or N/A Comments 1Internetconnectionfor activationand updates(For all OperatingSystems) N/A DeviceMassagechair CompanynameFujianRonghaoFitnessEquipmentCo.,Ltd. Granteecode2A45X FCC ID2A45X-HM-001 FRN0032030041 ContactnameChenzifu AddressNo.90,Budouting,QinxiyangIndustrialZone, FuanCity,NingdeCity,FujianProvinceChina Telephonenumber19105933123 [email protected] Chipset/moduleinformationAC6955F8 OperatingSystem(if applicable)N/A StorageCapacity(hard drive or other permanentmemorystorage, if applicable) N/A 2 #GeneralRequirements(ForWindowsDevices)Yes/Noor N/A Comments 1Storage:1500MBfreespaceontheharddriveN/A 2OperatingSystem: MicrosoftWindows8,8.1,10&11Home/Pro/ EnterpriseMicrosoft Windows7Starter/HomeBasic&Premium/ Professional/UltimateSP1orhigher N/A 3Processor:1GHzorhigher(x86orx64)N/A 4Memory(RAM)1GB(32-bit)or2GB(64-bit)N/A 5ScreenResolution:Minimumresolutionof1024x768N/A #GeneralRequirements(FormacOSdevices)Yes/Noor N/A Comments 1OperatingSystemmacOSÂź13–14N/A 2Memory(RAM)4GBN/A 3Storage:3455MBfreespaceontheharddriveN/A #GeneralRequirements(ForAndroidDevices)Yes/Noor N/A Comments 1Storage:150MBfreespaceN/A 2OperatingSystem:Androidℱ10–14N/A 3ScreenResolution:Minimumresolutionof320x480N/A #GeneralRequirements(foriOSdevices)Yes/Noor N/A Comments 1Storage:150MBfreespaceN/A 2OperatingSystem:iOSÂź17N/A 3 #GeneralRequirements(ForLinuxsystem)Yes/Noor N/A Comments 1Harddrive:1GBoffreespaceN/A 2CPU:IntelPentium1GHzorhigherN/A 3RAM:1GBN/A 4Minimumsoftwarerequirements: AlmaLinuxOS8orlater; AlterOS7.5orlater; AstraLinuxCommonEdition2.12orlater; CentOS6.7orlater; DebianGNU/Linux10.0orlater; EulerOS2.0orlater; OracleLinux7.3orlater; RedHatEnterpriseLinux6.7orlater; RockyLinux8.5orlater; SUSELinuxEnterpriseServer12.5orlater; Ubuntu12.04orlater; UncomOSHome/Business/Education/Enterprise 2.2orlater; ALTLinuxWorkstaton/WorkstationK/Server/ Education8orlater; ROSALinuxWorkstation/Server12orlater; REDOS7.3andlater; N/A Afterreviewedthetechnicalrequirements,isthedevicecapableofsupportingthe installationofKasperskysoftware? ☐Yes,gotoItem3. 4 ☒No. In this case, the rest of the items do not apply.The devicecannotsupport installationof Kasperskysoftware Item 3.ConnectivityCapabilities: #PhysicalInterfacePurposeJustification 1 1 #WirelessInterfacePurposeJustification 1 1 After the reviewof this items,the device: ☒ Cannotsupportinstallationof any cybersecurityor anti-virussoftwareon the covered list. ☐ Potentiallycan operatewith any cybersecurityor anti-virussoftwareon the coveredlist – additionalthird-partyproof is providedto demonstratecompliancewith requirementsas of 2.911(d)5(i),(ii)– “Proof of Compliancewith CoveredList SoftwareRequirements” of this documentapplies Signature:Name: Chen zifu Date: 2026.1.13 1 The justificationfield is usedto justifywhy the softwarecannotbe receivedthroughthat interface.Checkthe annexfor more indications.

Attestation Statements

FujianRonghaoFitnessEquipmentCo.,Ltd. ProductSimilarityDeclaration Productname:Massagechair Modelname:HM-001 HM-002,HM-003,HM-004,HM-005,HM-006,HM-007,HM-008,HM- 009,HM-010,HM-011,HM-012,HM-013,HM-014,HM-015,HM-016, HM-017,HM-018,HM-019,HM-020,anmoyi-GDYJPSK-HS02- BR/anmoyi-GDYJPSK-HS01-BK 2A45X-HM-001 We(FujianRonghaoFitnessEquipmentCo.,Ltd.)herebystatethatallthe modelsareelectricalidenticalincludingthesamesoftwareparameterand hardwaredesign(i.e.,circuitdesign,PCBLayout,RFmodule/circuit, antennatype(s)andantennalocation,componentsonPCB,etc.,),same mechanicalstructureanddesign(includingproductenclosure,materials, etc.,),Onlyfordifferentmodelname Signature: Name:Chenzifu Title:Manager Place,date:No.90,Budouting,QinxiyangIndustrialZone,FuanCity,Ningde City,FujianProvinceChina

Attestation Statements

TCB CALL pĂĄgina 1 File FCC ID: :2A45X-HM-001 Please upload an exhibit that explains how does the TCB verify the new agent information: 1- Is the address of the agent a valid physical US mailing address (not a US post office box, not a virtual mailbox, not P.O. Boxes, not a vacant lot, not a public building, etc.) ○ We have checked if the address exists in a real and potential building (Google maps) + official US register, after this verification and the evidence below we can guarantee the following: not a US post office box not a virtual mailbox not P.O. Boxes not a vacant lot not a public building(note) â–ș We checked the FCC FRN Search based on the information provided by the grantee. On the official register from : https://www.sos.state.co.us/biz/BusinessEntityDetail.do?quitButtonDestination=BusinessEntityResults&nameTyp=ENT&masterFileId=20248279136&entityId2=20248279136&fileId=20248279136&srchTyp=ENTITY TCB CALL pĂĄgina 2 Google: EIN Number TCB CALL pĂĄgina 3 â–ș CONCLUSION by TCB: The ASOP defined and provided by grantee is VALID and confirmed. Therefore the exhibit "C5266091_X23_Ed1_US_Agent_Letter" included in the file is ok. 2- Is the agent physically located at that valid US address such that the agent can be legally served at that address? Yes , check above 3- Has the listed agent clearly agreed in writing to serve as the agent for the grantee at that address? Yes, it is included in the exhibit "C5266091_X23_Ed1_US_Agent_Letter"

Attestation Statements

1/1 USAgentforServiceofProcessLETTEROFATTESTATION TO: OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USAgentforServiceofProcess: CompanyName:GOLDENVICTORYINTERNATIONALTRADINGCOLTD FRN:0036377570 ContactName:LeonHowar Address:11016THSTREETSUITE1400DENVER,CO80202UnitedStates TelephoneNo:(337)255-0461 Email:[email protected] Applicant: Companyname:FujianRonghaoFitnessEquipmentCo.,Ltd. ProductDescription:Massagechair Granteecode:2A45X FRN:0032030041 FCCID:2A45X-HM-001 ContactName:Chenzifu Address:No.90,Budouting,QinxiyangIndustrialZone,FuanCity,NingdeCity,FujianProvince China TelephoneNo.:19105933123 Email:[email protected] [FujianRonghaoFitnessEquipmentCo.,Ltd.]certifiesthat,asofthedateofthis filingoftheapplicationwiththeTCB,[GOLDENVICTORYINTERNATIONAL TRADINGCOLTD]isourdesignatedUSagentforserviceofprocessforthe abovereferencedFCCID.[FujianRonghaoFitnessEquipmentCo.,Ltd.]accepts tomaintainanagentfornolessthanoneyearafterthegranteehasterminated allmarketingandimportationortheconclusionofanycommissionrelated proceedinginvolvingequipment.[GOLDENVICTORYINTERNATIONAL TRADINGCOLTD]accepts,asofthedateofthefilingoftheapplication,the obligationofthedesignatedUSagentforserviceofprocessfortheabove referenceFCCID. TheUSAgentforServiceofProcessisawareofandagreestocomplywiththerequirements outlinedintheFCCEquipmentAuthorizationProgram,ReportandOrderFCC22-84,andclause §2.911. TheApplicantisawareofandagreestocomplywiththerequirementsoutlinedintheFCC EquipmentAuthorizationProgram,ReportandOrderFCC22-84,andclause§2.911. Date:2026.1.13 Applicant’sName:ChenzifuUSAgent’sName:LeonHowar Title:ManagerTitle:Manager Signature Signature

Attestation Statements

AttestationStatement. OldCode:C526609124NewCode:00015544Ed.3 Changereason:FRNisaddedtotheApplicantinformationsection. 1/1 TO: OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 TheCommissionadoptedrulesthatprohibitequipmentauthorizationfor“covered” telecommunicationsequipmentandvideosurveillanceequipmentproducedbyentitiesidentified ontheCommission’sCoveredList 1 ,whichisperiodicallyupdated.SeetheCoveredListformore details.ThisAttestationStatementistoconfirmthatwefollowtheSection2.911(d)(5)(i)-(ii) Applicant Companyname:FujianRonghaoFitnessEquipmentCo.,Ltd. Granteecode:2A45X FRN:0032030041 FCCID:2A45X-HM-001 ContactName:Chenzifu Address:No.90,Budouting,QinxiyangIndustrialZone,FuanCity,NingdeCity,FujianProvince China TelephoneNo.:19105933123 Email:[email protected] i.FujianRonghaoFitnessEquipmentCo.,Ltd.(“theapplicant”)certifiesthatthe equipmentforwhichauthorizationissoughtisnot“covered”equipment prohibitedfromreceivinganequipmentauthorizationpursuanttosection 2.903oftheFCCrules.Theapplicantmustsignthiscertification. ii.FujianRonghaoFitnessEquipmentCo.,Ltd.(“theapplicant”)certifiesthat,as ofthedateofthefilingoftheapplication,theapplicant[isnot](asa specificallynamedentityoranyofitssubsidiariesoraffiliates)identifiedon theCoveredListasanentityproducing“covered”equipment.Theapplicant mustsignthiscertification. [FujianRonghaoFitnessEquipmentCo.,Ltd.](“theapplicant”)certifiesthat,asof thedateofthefilingofthe application,theapplicant[isnot]identifiedontheCoveredList asanentityproducing“covered” equipment. Date:2026.1.13 Applicant’sName:Chenzifu Title:Manager Signature 1 TheCommission’sCoveredListispublishedbythePublicSafetyandHomelandSecurityBureauandpostedonthe Commission’swebsite.ThisCoveredList,whichisperiodicallyupdated,identifiesparticularequipment,producedby particularentities,thatconstitutes“covered”equipment.https://www.fcc.gov/supplychain/coveredlist

Cover Letter(s)

C5266091_X10_Ed.2 1/1 FujianRonghaoFitnessEquipmentCo.,Ltd. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:2026.1.13 Subject:RequestforConfidentiality FCCID:2A45X-HM-001 ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality NOTE2 IDLabel/LocationNoNo AttestationStatementNoNo ExternalPhotosNo ☐ BlockDiagram ☒☐ Schematics ☒☐ TestReportNoNo TestSetupPhotosNo ☐ User’sManual ☐ NOTE 1 ☐ InternalPhotos ☐ NOTE 1 ☐ PartsList/TuneUp ☐☐ RFExposureInfoNoNo OperationalDescription ☒☐ CoverLetter(s)NoNo SDRSoftware/SecurityInfo ☐ No NOTE1:Long-TermConfidentialitymaybepermittedunderspecialconditions(SeeII.LONG-TERMCONFIDENTIALITY,Section3of KDB726920,uselastinforce) NOTE2:Short-TermConfidentialitycanberequestedforamaximumof180daysfromthedateofthegrant. Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. Incaseofshort-termConfidentiality,theapplicantrequeststheexhibitsselected abovearewithheldfrompublicviewforaperiodof______daysfromthedateofthe GrantofEquipmentAuthorizationandpriortomarketing. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name:Chenzifu Title:Manager

Cover Letter(s)

C5266091_X8_Ed.1 1/1 LetterofAuthorization FujianRonghaoFitnessEquipmentCo.,Ltd. Company:FujianRonghaoFitnessEquipmentCo.,Ltd. Address:No.90,Budouting,QinxiyangIndustrialZone,FuanCity, NingdeCity,FujianProvinceChina ProductName:Massagechair ModelNumber:HM-001,HM-002,HM-003,HM-004,HM-005,HM-006, HM-007,HM-008,HM-009,HM-010,HM-011,HM-012,HM-013,HM- 014,HM-015,HM-016,HM-017,HM-018,HM-019,HM-020,anmoyi- GDYJPSK-HS02-BR/anmoyi-GDYJPSK-HS01-BK FCCIdentifier:2A45X-HM-001 WeauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdelCarme,s/n, 08193Bellaterra,Spain,toactonourbehalfonallmattersconcerningthe abovenamedequipment. AnyindividualwithinLGAITechnologicalCenterS.A.isauthorizedtoactonour behalfandtakeactionontheapplication. WedeclarethatauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdel Carme,s/n,08193Bellaterra,Spain,isallowedtoforwardallinformation relatedtotheapprovalprojecttotheFederalCommunicationCommissionand todiscussanyissuesconcerningtheapprovalapplication.Anyandallacts carriedoutbyLGAITechnologicalCenterS.A.onourbehalfshallhavethe sameeffectasactsofourown. Name:ChenzifuDate:2026.1.13 Title:Manager Signatureofapplicant:

External Photos

EUTPHOTO(ExternalPhotos) TestModel:HM-001 ※※※※※ENDOFREPORT※※※※※

ID Label/Location Info

Labelandlabellocation FCCIDLABEL: High:4cm Wide:8cm LabelLocation: Massagechair FCCID:2A45X-HM-001

Internal Photos

EUTPHOTO(InternalPhotos) TestModel:HM-001 ※※※※※ENDOFREPORT※※※※※ ANT

RF Exposure Info

FCCID:2A45X-HM-001 AccordingtoKDB447498D01GeneralRFExposureGuidancev06andpart2.1091 RFExposureEvaluation Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactofhumanexposure toradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE) Frequencyrange (MHz) Electricfield strength (V/m) Magneticfieldstrength (A/m) Powerdensity (mW/cm 2 ) Averagingtime (minutes) (A)LimitsforOccupational/ControlledExposures 0.3–3.06141.63*(100)6 3.0–301842/f4.89/f*(900/f 2 )6 30–30061.40.1631.06 300–1500f/3006 1500–100,00056 (B)LimitsforGeneralPopulation/UncontrolledExposure 0.3–1.346141.63*(100)30 1.34–30824/f2.19/f*(180/f 2 )30 30–30027.50.0730.230 300–1500f/150030 1500–100,0001.030 f=frequencyinMHz Friistransmissionformula:Pd=(Pout*G)/(4*pi*r 2 ) Where Pd=powerdensityinmW/cm 2 ,Pout=outputpowertoantennainmW; G=gainofantennainlinearscale,Pi=3.1416; R=distancebetweenobservationpointandcenteroftheradiatorincm PdidthelimitofMPE,1mW/cm 2 .Ifweknowthemaximumgainoftheantennaandthetotalpowerinputto theantenna,throughthecalculation,wewillknowthedistancerwheretheMPElimitisreached. TestProcedure SoftwareprovidedbyclientenabledtheEUTtotransmitandreceivedataatlowest,middleandhighest channelindividually. TestResultofRFExposureEvaluation ForBLE Mode Output powerto antenna (dBm) TuneUP tolerance (dBm) MaxTune UPpower (dBm) MaxTune UPpower (mW) Power Densityat R=20cm (mW/cm2) Limit (mW/cm2) Result GFSK3.2213±142.510.0004371.0PASS Antennagainfor:2.4G:-0.58dB SoaSARtestisnotrequired

Test Report

C DL-Cert ert DL-Cert DL D L-Cert DL-Cert DL-Cer D L-Cert DL-Cert DL-Cert Cert D L-Cert DL-Cert DL-Cert DL-C DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert ert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert D DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert DL-Ce DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert DL-Cert Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL- DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert ert DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert D DL-Cert DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-C DL-Cert DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert Cert DL-Cert DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert ert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Ce L-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert DL-Cert D DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert DL-C L-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert rt DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Ce DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL Cert DL-Cert DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-C L-Cert DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert rt DL-Cert DL-Cert DL-Cert D L-Cert DL-Ce DL-Cert DL-Cert DL-Cert D L-Cert DL Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert D L-C L-Cert DL-Cert rt DL-Cer DL Shenzhen DL Testing Technology Co., Ltd.Report No.:DLE-260109005R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 1 of 39 FCC TEST REPORT FCC ID:2A45X-HM-001 Applicant: Fujian Ronghao Fitness Equipment Co.,Ltd. Address: No.90, Budouting, Qinxiyang Industrial Zone, Fuan City, Ningde City, Fujian Province, China Manufacturer: Fujian Ronghao Fitness Equipment Co.,Ltd. Address: No.90, Budouting, Qinxiyang Industrial Zone, Fuan City, Ningde City, Fujian Province, China EUT:Massage chair Trade Mark:N/A Model Number: HM-001 HM-002, HM-003, HM-004, HM-005, HM-006, HM-007, HM-008, HM-009, HM-010, HM-011, HM-012, HM-013, HM-014, HM-015, HM-016, HM-017, HM-018, HM-019, HM-020, anmoyi-GDYJPSK-HS02-BR/anmoyi-GDYJPSK-HS01-BK Date of Receipt:Dec. 22, 2025 Test Date:Dec. 22, 2025 - Dec. 31, 2025 Date of Report:Dec. 31, 2025 Prepared By:Shenzhen DL Testing Technology Co., Ltd. Address: 101-201, Building C, Shuanghuan, No.8, Baoqing Roa Baolong Industrial Zone, Baolong Street, Longgang Shenzhen, Guangdong, China Applicable Standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 ANSI C63.10:2020 Test Result:Pass Report Number:DLE-260109005R Prepared (Test Engineer): Dimon Tan Reviewer (Supervisor): Jack Bu Approved (Manager): Jade Yang This test report is based on a single evaluation of one sample of above mentioned products. It is not permitted to be duplicated in extracts without written approval of Shenzhen DL Testing Technology Co., Ltd. C DL-Cert ert DL-Cert DL D L-Cert DL-Cert DL-Cer D L-Cert DL-Cert DL-Cert Cert D L-Cert DL-Cert DL-Cert DL-C DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert ert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert D DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert DL-Ce DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert DL-Cert Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL- DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert ert DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert D DL-Cert DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-C DL-Cert DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert Cert DL-Cert DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert ert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Ce L-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert DL-Cert D DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert DL-C L-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert rt DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Ce DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL Cert DL-Cert DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-C L-Cert DL-Cert DL-Cert DL-Cert D L-Cert DL-Cert rt DL-Cert DL-Cert DL-Cert D L-Cert DL-Ce DL-Cert DL-Cert DL-Cert D L-Cert DL Cert DL-Cert DL-Cert D L-Cert DL-Cert DL-Cert D L-C L-Cert DL-Cert rt DL-Cer DL Shenzhen DL Testing Technology Co., Ltd.Report No.:DLE-260109005R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 2 of 39 Table of ContentsPage 1.VERSION....................................................................................................................4 2. SUMMARY OF TEST RESULTS............................................................................... 5 2.1 TEST FACILITY.................................................................................................................6 2.2 MEASUREMENT UNCERTAINTY....................................................................................6 3. GENERAL INFORMATION........................................................................................7 3.1 GENERAL DESCRIPTION OF EUT................................................................................. 7 3.2 DESCRIPTION OF TEST MODES.........................................


Text truncated - open the document above for the full version.

Test Report

Inverted F Antenna Specification Summary ITEM ANT SPEC Model Name 2.4G ANT Horizontal Vertical 2400MHz 24 50MHz 2500MHz2400MHz 24 50MHz 2500MHz Center Frequency -1.26-0.76-0.58- 5.25-2.46-1.86 MAX. Gain -0.58dBi Polarization Horizontal and Vertical Azimuth Beam Pattern Omni-directional Impedance 50 Ohm Manufacture ZHUHAI JIELI TECHNOLOGY CO.,LTD Antenna Photo & Length (mm) 11.6 No. 333 Kexing Road, Xiangzhou District, Zhuhai City, Guangdong Province Horizontal: 2400 MHz 2450 MHz 2500 M Hz Power (dBi) Max : 0 Min: -40 Scale: 5/div Gain(dBi) Frequency (MHz) MaxMinAvg 2400-1.26174-30.0801-7.18716 2450-0.765802-36.5604-7.48023 2500-0.585582-22.0315-6.59127 Vertical: 2400 MHz 2450 MHz 2500 M Hz Power (dBi) Max : 0 Min: -30 Scale: 5/div Gain(dBi) Frequency (MHz) MaxMinAvg 2400-5.2537-22.1424-12.4294 2450-2.4652-24.5837-10.4702 2500-1.86120-29.5214-9.20432 ANT Test LabsAttestation of Global Compliance Co., Ltd.

Test Setup Photos

EUTTESTPHOTO TestModel:HM-001

Contact Information

Applicant

Chen zifu
[email protected]Fax: 19105933123

Technical Contact

GOLDEN VICTORY INTERNATIONAL TRADING CO LTDLeon Howar
[email protected]

110 16TH STREET SUITE 1400 DENVER, CO 80202 United · DENVER, Colorado, 80202 · United States

Test Firm

Shenzhen DL Testing Technology Co., Ltd.Jade Yang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.10 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End-users must be provided with operating procedures for satisfying RF exposure compliance.