Rev. AUG 27, 2025 IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY UNDER-CABINET LIGHTS ITM. / ART. 1938108 INSTRUCTIONS Costco Wholesale Spain S.L.U. Polígono Empresarial Los Gavilanes C/ Agustín de Betancourt, 17 28906 Getafe (Madrid) España NIF: B86509460 900 111 155 www.costco.es Costco Wholesale Japan Ltd. 2 Kakuchi, 2 Gaiku, Kaneda-Nishi 361 Urikura, Kisarazu shi Chiba, 292-0007 Japan 0570-200-800 www.costco.co.jp Costco Wholesale Korea, Ltd. 40, Iljik-ro Gwangmyeong-si Gyeonggi-do, 14347, Korea 1899-9900 www.costco.co.kr Costco Wholesale New Zealand Limited 2 Gunton Drive Westgate Auckland 0814 New Zealand www.costco.co.nz Costco (China) Investment Co., Ltd. Room 01 Mezzanine No. 5178, Kang Xin Highway Pudong New District Shanghai China 201315 +86-21-6257-7065 Costco France 1 avenue de Bréhat 91140 Villebon-sur-Yvette France 01 80 45 01 10 www.costco.fr Costco Wholesale Iceland ehf. Kauptún 3-7, 210 Gardabaer Iceland www.costco.is Distributed by: Costco Wholesale Corporation P.O. Box 34535 Seattle, WA 98124-1535 USA 1-800-774-2678 www.costco.com Costco Wholesale Canada Ltd.* 415 W. Hunt Club Road Ottawa, Ontario K2E 1C5, Canada 1-800-463-3783 www.costco.ca * faisant aaire au Québec sous le nom les Entrepôts Costco Costco Wholesale UK Ltd / Costco Online UK Ltd Hartspring Lane Watford, Herts WD25 8JS United Kingdom 01923 213113 www.costco.co.uk Importado por: Importadora Primex S.A. de C.V. Blvd. Magnocentro No. 4 San Fernando La Herradura Huixquilucan, Estado de México C.P. 52765 RFC: IPR-930907-S70 (55)-5246-5500 www.costco.com.mx Costco Wholesale Australia Pty Ltd 17-21 Parramatta Road Lidcombe NSW 2141 Australia www.costco.com.au Costco Wholesale Sweden AB Box 614 114 11 Stockholm Sweden www.costco.se Made in China FR Points de collecte sur www.quefairedemesdechets.fr Privilégiez la réparation ou le don de votre appareil ! Ces appareils et leurs piles se recyclent À DÉPOSER EN MAGASIN OU À DÉPOSER EN DÉCHÈTERIE FR FR Manufacturer / Fabricant / Fabricante / Tillverkare : ©2021 INFINITY X1 LLC® 3525 Del Mar Heights Rd, Suite 867 San Diego, CA 92130, USA www.infinityx1.com CUSTOMER SERVICE / SERVICE À LA CLIENTÈLE / SERVICIO DE ATENCIÓN A CLIENTE / KUNDTJÄNST: 1-800-942-1666 In English and Spanish / En anglais et en espagnol En inglés y español / På engelska och spanska HOURS / HEURES / HORARIO / TIMMAR: M-F 8AM to 5PM Pacific Time Du lundi au vendredi, de 8 h à 17 h (heure du Pacifique) De lunes a viernes de 8 a. m. a 5 p. m. (solo en EE. UU.), hora estándar del Pacífico Måndag till fredag, kl. 8.00-17.00 (Stillahavstid) SUPPORT IN ENGLISH AND ALTERNATE LANGUAGES (ONLINE ONLY) SOUTIEN EN ANGLAIS ET DANS D'AUTRES LANGUES (SEULEMENT EN LIGNE) ASISTENCIA EN INGLÉS Y OTROS IDIOMAS (SÓLO EN LÍNEA) SUPPORT PÅ ENGELSKA OCH ALTERNATIVA SPRÅK (ENDAST ONLINE) Web / Site Web : myproduct.infinityx1.com Email / Courriel / Correo electrónico / E-post: [email protected] CAUTION: Possible hazardous optical radiation emitted from this product. The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 1.5 m / 4.9 ft is not expected. 335.2 mm (13.25 in) 1m 10 h 10 m 30cd 200 LUMENS / LÚMENES HIGH FL1 STANDARD NORME FL1 NORMA FL1 OUTSIDEOUTSIDE 139.7 mm (5.5 in) OUTSIDE 139.7 mm (5.5 in)139.7 mm (5.5 in) OUTSIDE 139.7 mm (5.5 in) OUTSIDE ENGLISH UNDER-CABINET LIGHTS ITM. / ART. 1938108 1. 2. 3. Quick press the GREY power button on each light to turn them ON. Remove protective film from lens of each light. Place the 2 small metal plates over the magnetic markings on the back of each light. Peel one side of the 3M sticker. Install the Under-Cabinet Lights on the wall or anywhere. 4. Magnetic Back Place the small, circular metal plate on the remote’s back, peel one side of the 3M sticker. INSTALLATION 5. Install the remote control in the area near the Under-Cabinet Light. READY TO USE REMOTE CONTROL The lights and remote come with a factory preset code to function in Zone 1 with the motion detection set at 10' for each unit. Motion sensor turns on light when motion is detected in darkness USB-C USB-C IN to charge remote 1. Select desired ZONE on back of the remote 2. Press front of remote to activate Long-press for dimming RF Band: 2.4G Transmitter Power: 0.15W The indicator is red when charging and turns green when unit is fully charged. Long-press for dimming SWITCH AND LIGHT MODE FUNCTION Click to adjust color temperature 1x 1x 1x Zone Selection OFF - ZONE 1 - ZONE 2 To Activate Remote Control Adjust Motion Sensing Distance OFF / up to 5 ft / up to 10 ft / up to 20 ft Line of sight distance ZONE CONTROL MODE ALL ACTIVATES ZONE 1 AND ZONE 2 MODE 1 ACTIVATES ZONE 1 ONLY MODE 2 ACTIVATES ZONE 2 ONLY ZONE 1 ZONE 2 ZONE 1 ZONE 2 ZONE 1 ZONE 2 CHARGING LIGHT USB-C The indicator is red when charging and turns green when unit is fully charged. WIRELESS LINKING RESET (Advanced Troubleshooting) Using the supplied 3M stickers and metal plates, simply mount the lights anywhere you need lighting, power on and start using! 1. Align the magnets located on the back of the wall light to attract the metal plate. 2. The metal plate can be fixed on a smooth surface with 3M sticker (included). Installation completed 1. Set the lights Zone setting to “OFF” (the other settings do not aect this). 2. On each light hold down the power button for 15 seconds. Factory reset is complete when the light flashes 3 times quickly. 3. Set the remote to “ALL” and hold down the grey link reset button for 15 seconds. Factory reset is complete when the blue perimeter light flashes 3 times quickly. HOW TO RESET CODES TO FACTORY SETTINGS 1. Select Zone 1 or Zone 2 on each light and remote for the desired group. Hold the power button for 5 seconds. Repeat for all devices within 30 seconds. 2. Lights will begin to dim, then one light will flash on and o during pairing mode. The flashing light will turn o when all the lights are linked to your newly created code. CREATE A NEW UNIQU…
Text truncated - open the document above for the full version.
Ningbo Yada Electric Products Co., Ltd 625Xidian Wangjia Ninghai Ningbo, China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2026/01/26 U.S. Agent Designation Ningbo Yada Electric Products Co., Ltd acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2A4B2-01938108): Name and company of U.S. agent: GLOCERTS TECHNOLOGY INC Physical U.S. address of agent: 19784 SUNKISSED RIDGE DR RIVERSIDE, CA 92507 United States FRN of U.S. agent: 0036339737 Email address of U.S. agent: [email protected] GLOCERTS TECHNOLOGY INC acknowledges their obligation to accept service of process on behalf of Ningbo Yada Electric Products Co., Ltd Ningbo Yada Electric Products Co., Ltd with the FRN [0031865090] accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. An expiration date for this letter does not exist. Sincerely, Signature Tina Chung Manager Ningbo Yada Electric Products Co., Ltd Signature Huiying Fan Director GLOCERTS TECHNOLOGY INC 48_[mo del] US_Agent_2.911(d)(7) - U, V0 5
FCC ID:2A4B2-01938108 External Photos of the EUT FCC ID:2A4B2-01938108 FCC ID:2A4B2-01938108
Label and Location Size: L: 1.0cm*W: 0.5cm Label and Location FCC ID : 2A4B2-01938108
FCC ID:2A4B2-01938108 Internal Photos of the EUT FCC ID:2A4B2-01938108 BT ANT
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn RF Exposure evaluation Report Reference No. .................... : FCC ID. ........................................... : CTA25122600802 2A4B2-01938108 Compiled by ( position+printed name+signature) . : File administrators Zoey Cao Supervised by ( position+printed name+signature) . : Project Engineer Ace Chai Approved by ( position+printed name+signature) . : RF Manager Eric Wang Date of issue .................................... : Jan. 04, 2026 Testing Laboratory Name ............. : Shenzhen CTA Testing Technology Co., Ltd. Address ........................................... : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name ........................... : Ningbo Yada Electric Products Co., Ltd Address ........................................... : 625Xidian Wangjia Ninghai Ningbo, China Standard .......................................... : 47CFR §1.1310 47CFR §2.1093 KDB447498 D01 General RF Exposure Guidance v06 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purpses as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : undercabinet light Trade Mark ...................................... : N/A Manufacturer .................................... : Ningbo Yada Electric Products Co., Ltd Model/Type reference ...................... : 1938108 Listed Models ................................... : N/A Ratings ............................................. : DC 3.7V From battery and DC 5.0V From external circuit Result ............................................... : PASS Report No.: CTA25122600802 Page 2 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : undercabinet light Model /Type : 1938108 Listed Models : N/A Applicant : Ningbo Yada Electric Products Co., Ltd Address : 625Xidian Wangjia Ninghai Ningbo, China Manufacturer : Ningbo Yada Electric Products Co., Ltd Address : 625Xidian Wangjia Ninghai Ningbo, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA25122600802 Page 3 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS ............................................................................................................ 4 2 SUMMARY .......................................................................................................................... 5 2.1 General Remarks ..................................................................................................... 5 2.2 Product Description ................................................................................................. 5 2.3 Special Accessories ................................................................................................. 5 2.4 Modifications ............................................................................................................ 5 3 TEST ENVIRONMENT ....................................................................................................... 6 3.1 Address of the test laboratory .................................................................................. 6 3.2 Test Facility .............................................................................................................. 6 3.3 Statement of the measurement uncertainty ............................................................. 6 4 Test limit .............................................................................................................................. 7 4.1 Requirement ............................................................................................................ 7 4.2 Conducted Power Results ....................................................................................... 7 4.3 Manufacturing tolerance .......................................................................................... 8 4.4 Evaluation Result ..................................................................................................... 8 4.5 Simultaneous Transmission for SAR Exclusion ...................................................... 8 5 Conclusion ........................................................................................................................... 8 Report No.: CTA25122600802 Page 4 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 1 T E S T S T A N D A R D S The tests were performed according to following standards: ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagneti…
Text truncated - open the document above for the full version.
1. Antenna Description: Antenna type PCB antenna Model 1938108 Frequency range 2400-2500MHz Manufacturer Ningbo Yada Electric Products Co., Ltd Address 625Xidian Wangjia Ninghai Ningbo, China ANT Peak Gain 0.68 dBi 2. Antenna Photo: Length :12.39mm Width:3.75mm 3. Test Equipment & Conditions 3.1 Test instrument VSWR is tested using Agilent E5071B connected to a hand mechanism, and the status is free space. 3.2 Test environment and methods 4.Antenna Radiation Pattern 2400MHz 2450MHz 2500MHz
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn FCC PART 15 SUBPART C TEST REPORT FCC PART 15.247 Report Reference No. ...................: FCC ID. ......................................... : CTA25122600801 2A4B2-01938108 Compiled by ( position+printed name+signature) : File administrators Zoey Cao Supervised by ( position+printed name+signature) : Project Engineer Ace Chai Approved by ( position+printed name+signature) : RF Manager Eric Wang Date of issue ...................................: Jan. 04, 2026 Testing Laboratory Name .............: Shenzhen CTA Testing Technology Co., Ltd. Address ..........................................: Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name...........................: Ningbo Yada Electric Products Co., Ltd Address ...........................................: 625Xidian Wangjia Ninghai Ningbo, China Test specification ......................... : Standard ..........................................: FCC Part 15.247 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Equipment description ................ : undercabinet light Trade Mark ......................................: N/A Manufacturer ...................................: Ningbo Yada Electric Products Co., Ltd Model/Type reference .....................: 1938108 Listed Models ..................................: N/A Modulation ......................................: GFSK Frequency .......................................: From 2402MHz to 2480MHz Ratings ............................................: DC 3.7V From battery and DC 5.0V From external circuit Result ..............................................: PASS Report No.: CTA25122600801 Page 2 of 34 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : undercabinet light Model /Type : 1938108 Listed Models : N/A Applicant : Ningbo Yada Electric Products Co., Ltd Address : 625Xidian Wangjia Ninghai Ningbo, China Manufacturer : Ningbo Yada Electric Products Co., Ltd Address : 625Xidian Wangjia Ninghai Ningbo, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA25122600801 Page 3 of 34 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS ...................................................................................................................................... 4 2 SUMMARY .................................................................................................................................................... 5 2.1 General Remarks .............................................................................................................................. 5 2.2 Product Description* ......................................................................................................................... 5 2.3 Equipment Under Test ...................................................................................................................... 5 2.4 Short description of the Equipment under Test (EUT) ..................................................................... 5 2.5 EUT configuration ............................................................................................................................. 5 2.6 EUT operation mode ........................................................................................................................ 5 2.7 Block Diagram of Test Setup ............................................................................................................ 6 2.8 Related Submittal(s) / Grant (s) ........................................................................................................ 6 2.9 Modifications ..................................................................................................................................... 6 3 TEST ENVIRONMENT ................................................................................................................................. 7 3.1 Address of the test laboratory ........................................................................................................... 7 3.2 Test Facility ....................................................................................................................................... 7 3.3 Environmental conditions ................................................................................................................. 7 3.4 Summary of measurement results .................................................................................................... 8 3.5 Statement of the measurement uncertainty ............................................................................…
Text truncated - open the document above for the full version.
1 FCC Appendix RF Test Data for BLE FCC ID : 2A4B2-01938108 Company : Ningbo Yada Electric Products Co., Ltd EUT : undercabinet light Model Number : 1938108 Report No. : CTA25122600801 Reviewed By : Eric Wang 2 Appendix A: DTS Bandwidth Test Result TestMode Antenna Freq(MHz) DTS BW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant1 2402 0.652 2401.692 2402.344 0.5 PASS 2440 0.640 2439.692 2440.332 0.5 PASS 2480 0.644 2479.696 2480.340 0.5 PASS 3 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 4 5 Appendix B: Occupied Channel Bandwidth Test Result TestMode Antenna Freq(MHz) OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant1 2402 1.0081 2401.5186 2402.5267 --- --- 2440 1.0109 2439.5174 2440.5283 --- --- 2480 1.0096 2479.5194 2480.5290 --- --- 6 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 7 8 Appendix C: Maximum conducted output power Test Result Peak TestMode Antenna Freq(MHz) Conducted Peak Powert[dBm] Conducted Limit[dBm] Verdict BLE_1M Ant1 2402 -0.18 ≤30 PASS 2440 -0.50 ≤30 PASS 2480 -0.47 ≤30 PASS 9 Appendix D: Maximum power spectral density Test Result TestMode Antenna Freq(MHz) Result[dBm/3kHz] Limit[dBm/3kHz] Verdict BLE_1M Ant1 2402 -15.70 ≤8.00 PASS 2440 -15.92 ≤8.00 PASS 2480 -16.00 ≤8.00 PASS 10 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 11 12 Appendix E: Band edge measurements Test Result TestMod e Antenn a ChNam e Freq(MHz ) RefLevel[dBm ] Result[dBm ] Limit[dBm ] Verdic t BLE_1M Ant1 Low 2402 -1.48 -53.57 ≤-21.48 PASS High 2480 -0.59 -52.58 ≤-20.59 PASS 13 Test Graphs BLE_1M_Ant1_Low_2402 BLE_1M_Ant1_High_2480 14 Appendix F: Conducted Spurious Emission Test Result TestMode Antenna Freq(MHz) FreqRange [MHz] RefLevel [dBm] Result[dBm] Limit[dBm] Verdict BLE_1M Ant1 2402 Reference -1.80 -1.80 --- PASS 30~1000 -1.80 -68.31 ≤-21.8 PASS 1000~26500 -1.80 -41.33 ≤-21.8 PASS 2440 Reference -1.88 -1.88 --- PASS 30~1000 -1.88 -68.64 ≤-21.88 PASS 1000~26500 -1.88 -42.9 ≤-21.88 PASS 2480 Reference -2.32 -2.32 --- PASS 30~1000 -2.32 -68.61 ≤-22.32 PASS 1000~26500 -2.32 -42.07 ≤-22.32 PASS 15 Test Graphs BLE_1M_Ant1_2402_0~Reference BLE_1M_Ant1_2402_30~1000 BLE_1M_Ant1_2402_1000~26500 16 BLE_1M_Ant1_2440_0~Reference BLE_1M_Ant1_2440_30~1000 17 BLE_1M_Ant1_2440_1000~26500 BLE_1M_Ant1_2480_0~Reference BLE_1M_Ant1_2480_30~1000 18 BLE_1M_Ant1_2480_1000~26500 19 Appendix G: Duty Cycle Test Result TestMode Antenna Freq(MHz) ON Time [ms] Period [ms] X DC [%] xFactor Limit Verdict BLE_1M Ant1 2402 0.41 0.62 0.6613 66.13 1.80 --- --- 2440 0.41 0.62 0.6613 66.13 1.80 --- --- 2480 0.41 0.62 0.6613 66.13 1.80 --- --- 20 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 21 22 Appendix H: Emissions in Restricted Bands Test Result TestMod e Antenn a ChNam e Freq(MH z) Detector Freq [MHz] Result [dBm] Gain [dB] Result [dBuV/m] Limit [dBuV/m] Verdict BLE_1M Ant1 Low 2402 AV 2310.000 -60.25 2.00 36.95 ≤54 PASS AV 2363.420 -58.88 2.00 38.32 ≤54 PASS AV 2390.000 -60.11 2.00 37.09 ≤54 PASS Peak 2310.000 -51.91 2.00 45.29 ≤74 PASS Peak 2380.640 -48.93 2.00 48.27 ≤74 PASS Peak 2390.000 -51.94 2.00 45.26 ≤74 PASS High 2480 AV 2483.500 -58.2 2.00 39.00 ≤54 PASS AV 2484.880 -57.69 2.00 39.51 ≤54 PASS AV 2500.000 -59.67 2.00 37.53 ≤54 PASS Peak 2483.500 -48.53 2.00 48.67 ≤74 PASS Peak 2484.320 -46.17 2.00 51.03 ≤74 PASS Peak 2500.000 -51.71 2.00 45.49 ≤74 PASS Note:The limit in dBm for average detector is conversion from 54dBuV/m, according to 15.209(a). The limit in dBm for peak detector is 20dB above the limit of average detector in dBm. 23 Test Graphs BLE_1M_Ant1_Low_2402_AV BLE_1M_Ant1_Low_2402_Peak BLE_1M_Ant1_High_2480_AV 24 BLE_1M_Ant1_High_2480_Peak
FCC ID:2A4B2-01938108 Test Setup Photos of the EUT FCC ID:2A4B2-01938108
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.00 mW |