
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
1/1 US Agent for Service of Process LETTER OF ATTESTATION TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 US Agent for Service of Process: Company Name: GSS SERVICE INC Contact Name: MichouxLogan Address: 6547 N Academy Blvd #2266 Colorado Springs Co 80918 USA FRN: 0033402082 Telephone No: 001-949-2990192 Fax No: 001-949-2990192 Email: [email protected] Applicant: Company name: Shenzhen Zhiqi Technology Co.,LTD Grantee code: 2A4FI FCC ID: 2A4FI-A7 Contact Name: Tom huang Address: 401-2, 4th Floor, No. 466-2, Longcheng Street, Longgang District, Shenzhen Telephone: 15875445943 Fax: 15875445943 E-mail: [email protected] [Shenzhen Zhiqi Technology Co.,LTD] certifies that, as of the date of this filing of the application with the TCB, [GSS SERVICE INC] is our designated US agent for service of process for the above referenced FCC ID. [Shenzhen Zhiqi Technology Co.,LTD] accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission related proceeding involving equipment. [GSS SERVICE INC] accepts, as of the date of the filing of the application, the obligation of the designated US agent for service of process for the above reference FCC ID. The US Agent for Service of Process is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. The Applicant is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. Date: 2023/07/03 Applicant’s Name: Tom huang US Agent’s Name: MichouxLogan Title: Manager Title: Manager Signature Signature
C5266091_X24_Ed.2 1/1 “Attestation Statements” TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 The Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List 1 , which is periodically updated. See the Covered List for more details. This Attestation Statement is to confirm that we follow the Section 2.911(d)(5)(i)-(ii) Applicant Company name: Shenzhen Zhiqi Technology Co.,LTD Grantee code: 2A4FI FCC ID: 2A4FI-A7 Contact Name: Tom huang Address: 401-2, 4th Floor, No. 466-2, Longcheng Street, Longgang District, Shenzhen Telephone: 15875445943 Fax: 15875445943 E-mail: [email protected] i. [Shenzhen Zhiqi Technology Co.,LTD] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. The applicant must sign this certification. ii. [Shenzhen Zhiqi Technology Co.,LTD] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] (as a specifically named entity or any of its subsidiaries or affiliates) identified on the Covered List as an entity producing “covered” equipment. The applicant must sign this certification. [Shenzhen Zhiqi Technology Co.,LTD] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [ is not] identified on the Covered List as an entity producing “covered”equipment . Date: 2023/07/03 Applicant’s Name: Tom huang Title: Manager Signature 1 The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist
Shenzhen Zhiqi Technology Co., Ltd. Product Similarity Declaration Company: Shenzhen Zhiqi Technology Co., Ltd. Address: Baocheng TaizhihuiSquare, No.38 QinfuRoad, LiuyueCommunity, HenggangStreet, Longgang District, Shenzhen, China Product Name: Retro bluetooth speaker Model Number: A7, A3, E300 FCC Identifier: 2A4FI-A7 We (Shenzhen Zhiqi Technology Co., Ltd.) hereby state that all the models are electrical identical including the same software parameter and hardware design (i.e., circuit design, PCB Layout, RF module/circuit, antenna type(s) and antenna location, components on PCB, etc.,), same mechanical structure and design (including product enclosure, materials, etc.,), the only difference is the model name and appearance color. Client’s signature Name: Tom huang Date: 2023-07-03 Title: Manager Signature of applicant:
Shenzhen Zhiqi Technology Co., Ltd. 1/1 Letter of Authorization Company: Shenzhen Zhiqi Technology Co., Ltd. Address: Baocheng TaizhihuiSquare, No.38 QinfuRoad, LiuyueCommunity, HenggangStreet, Longgang District, Shenzhen, China Product Name: Retro bluetooth speaker Model Number: A7, A3, E300 FCC Identifier: 2A4FI-A7 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Tom huang Date: 2023-07-03 Title: Manager Signature of applicant:
Shenzhen Zhiqi Technology Co., Ltd. 1/1 Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2023-07-03 Subject: Request for Confidentiality FCC ID: 2A4FI-A7 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual No ☐ Internal Photos No ☐ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, Name: Tom huang Date: 2023-07-03 Title: Manager Signature of applicant:
Size:26*20mm M/N: A7 FCC ID: 2A4FI-A7 IC: 30355-A7 Label location
ANT
FCC ID: 2A4FI-A7 RF Exposure Evaluation According to KDB 447498 D01 V06 and part 2.1093,Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition(s), listed below, is (are) satisfied. For 100 MHz to 6 GHz and test separation distances ≤ 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [√f (GHz) ] ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR, where f (GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison EIRP=E Meas +20log(d Meas )-104.7 EIRP is the equivalent isotropically radiated power, in dBm E Meas is the field strength of the emission at the measurement distance, in dBμV/m d Meas is the measurement distance, in m Here, For EDR Field strength (dBuV/m) EIRP (dBm) Max tune-up (mW) Frequency (MHz) Min. distance(mm) Calc. thresholds limit 84.35 -10.81 0.083 2480 5 0.026 3.0 So a SAR test is not required
Summary Antenna Specification ITEMANT SPEC Model Name2.4G ANT MAX. Gain 1.08dBi PolarizationHorizontal and Vertical Azimuth Beam Pattern Omni-directional Impedance50 Ohm Antenna Length38.20mm Manufacture Shenzhen Zhiqi Technology Co.,LTD ÏÚ 2‹ Œøº∑ø ̈∑±≤ Ω∏øÆøΩ ̈ªÆ∑≠ ̈∑Ω≠ ±∫ ø≤ ̈ª≤≤ø PHI 0° PHI90° THETA90 ° Frequency VNA (MHz) Gain (Peak) (dBi) 2400MHz0.0403503 2410MHz0.0886264 2420MHz0.267381 2430MHz0.193012 2440MHz0.26366 2450MHz0.0723139 2460MHz0.36895 2470MHz0.551525 2480MHz0.640702 2490MHz1.05232 2500MHz1.08443
Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-20230612038E Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 1 of 42 FCC Part 15C Test Report FCC ID: 2A4FI-A7 Applicant: Shenzhen Zhiqi Technology Co.,LTD Address: Baocheng TaizhihuiSquare, No.38 QinfuRoad, LiuyueCommunity, HenggangStreet, Longgang District, Shenzhen, China Manufacturer: Shenzhen Zhiqi Technology Co.,LTD Address: Baocheng TaizhihuiSquare, No.38 QinfuRoad, LiuyueCommunity, HenggangStreet, Longgang District, Shenzhen, China EUT: Retro bluetooth speaker Trade Mark: N/A Model Number: A7 A3, E300 Date of Receipt: Jun. 02, 2023 Test Date: Jun. 02, 2023 - Jun. 13, 2023 Date of Report: Jun. 13, 2023 Prepared By: Shenzhen DL Testing Technology Co., Ltd. Address: 101-201, Building C, Shuanghuan, No.8, Baoqing Road, Baolong Industrial Zone, Baolong Street, Longgang District, Shenzhen, Guangdong, China Applicable Standards: FCC PART 15 C 15.249 ANSI C63.10:2013 Test Result: Pass Report Number: DL-20230612038E Prepared (Test Engineer): Pxing Huang Reviewer (Supervisor): Jack Bu Approved (Manager): Jade Yang This test report is based on a single evaluation of one sample of above mentioned products. It is not permitted to be duplicated in extracts without written approval of Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-20230612038E Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 2 of 42 Table of Contents Page 1 . SUMMARY OF TEST RESULTS 4 1.1 MEASUREMENT UNCERTAINTY 4 2 . GENERAL INFORMATION 5 2.1 GENERAL DESCRIPTION OF EUT 5 2.2 DESCRIPTION OF TEST MODES 7 2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 7 2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE) 8 2.5 TABLE OF PARAMETERS OF TEST SOFTWARE SETTING 8 2.6 EQUIPMENTS LIST FOR ALL TEST ITEMS 9 3 . EMC EMISSION TEST 10 3.1 CONDUCTED EMISSION MEASUREMENT 10 3.1.1 POWER LINE CONDUCTED EMISSION LIMITS 10 3.1.2 TEST PROCEDURE 10 3.1.3 DEVIATION FROM TEST STANDARD 10 3.1.4 TEST SETUP 11 3.1.5 EUT OPERATING CONDITIONS 11 3.1.6 TEST RESULTS 11 3.2 RADIATED EMISSION MEASUREMENT 14 3.2.1 RADIATED EMISSION LIMITS 14 3.2.2 TEST PROCEDURE 15 3.2.3 DEVIATION FROM TEST STANDARD 15 3.2.4 TEST SETUP 15 3.2.5 EUT OPERATING CONDITIONS 16 3.2.6 TEST RESULTS (BETWEEN 9KHZ – 30 MHZ) 17 3.2.7 TEST RESULTS (BETWEEN 30MHZ – 1GHZ) 18 3.2.8 TEST RESULTS (1GHZ~25GHZ) 20 3.3 RADIATED BAND EMISSION MEASUREMENT 23 3.3.1 TEST REQUIREMENT: 23 3.3.2 TEST PROCEDURE 23 3.3.3 DEVIATION FROM TEST STANDARD 23 3.3.4 TEST SETUP 24 3.3.5 EUT OPERATING CONDITIONS 24 4 . BANDWIDTH TEST 28 4.1 APPLIED PROCEDURES / LIMIT 28 4.1.1 TEST PROCEDURE 28 4.1.2 DEVIATION FROM STANDARD 28 4.1.3 TEST SETUP 28 4.1.4 EUT OPERATION CONDITIONS 28 Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-20230612038E Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 3 of 42 Table of Contents Page 4.1.5 TEST RESULTS 29 5 . ANTENNA REQUIREMENT 32 5.1 STANDARD REQUIREMENT 32 5.2 EUT ANTENNA 32 6 . TEST SEUUP PHOTO 33 7 . EUT PHOTO 35 Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-20230612038E Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 4 of 42 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15 (15.249) , Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission PASS 15.205(a), 15.209(a) 15.249(a), 15.249(c) Fundamental &Radiated Spurious Emission Measurement PASS 15.249(d) Band Edge Emission PASS 15.215(c) 20dB Bandwidth PASS 15.203 Antenna Requirement PASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report 1.1 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 Conducted Emission Test ±2.56dB 2 RF power,conducted ±0.42dB 3 Spurious emissions,conducted ±2.76dB 4 All emissions,radiated(<1G) ±3.65dB 5 All emissions,radiated(>1G) ±4.89dB 6 Temperature ±0.5°C 7 Humidity ±2% 8 20dB Bandwidth ±0.2MHz Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-20230612038E Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 5 of 42 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF EUT Product Name: Retro bluetooth speaker Trademark N/A Model No.: A7 A3, E300 Model Difference The product's different for model number and appearance color. Operation Frequency: 2402~2480MHz Channel numbers: 79 Channels Channel separation: 1M Modulation technology: GFSK, PI/4 DQPSK, 8DPSK Antenna Type: PCB antenna Antenna gain: 1.08dBi Power supply: DC 5V from adapter Adapter: Model Number: C006-050100-AVV1 Input: 100-240V~ 50/60Hz 0.2A Output: DC 5.0V/1.0A Note: 1.For a more detailed features description, please refer to the manufacturer’s specifications or the User's Manual. 2.The EUT’s all information provided by client. Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-20230612038E Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 6 of 42 3. Channel List Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) 00 2402 27 2429 54 2456 01 2403 28 2430 55 2457 02 2404 29 2431 56 2458 03 2405 30 2432 57 2459 04 2406 31 2433 58 2460 05 2407 32 2434 59 2461 06 2408 33 2435 60 2462 07 2409 34 2436 61 2463 08 2410 35 2437 62 2464 09 2411 36 2438 63 2465 10 2412 37 2439 64 2466 11 2413 38 2440 65 2467 12 2414 39 2441 66 2468 13 2415 40 2442 67 2469 14 2416 41 2443 68 2470 15 2417 42 2444 69 2471 16 2418 43 2445 70 2472 17 2419 44 2446 71 2473 18 2420 45 2447 72 2474 19 2421 46 2448 73 2475 20 2422 47 2449 74 2476 21 2423 48 2450 75 2477 22 2424 49 2451 76 2478 23 2425 50 2452 77 2479 24 2426 51 2453 78 2480 25 2427 52 2454 26 2428 53 2455 Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-20230612038E Test Report…
Text truncated - open the document above for the full version.
Radiated Measurement Photos Conducted Measurement Photos
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | - |