FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Cloudy Bay Lighting Supply Inc/
  3. 2A4FVCBSHL74BLORBH

2A4FVCBSHL74BLORBHLow voltage smart hardscape paver light

Cloudy Bay Lighting Supply Inc
Low voltage smart hardscape paver light - FCC ID 2A4FVCBSHL74BLORBH - Cloudy Bay Lighting Supply Inc
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 15, 2022
Application Purpose
Original Equipment
Date of Application
Aug 15, 2022
Equipment Note
Low voltage smart hardscape paver light
Frequency Range
2402.00000000 - 2480.00000000
Company
Cloudy Bay Lighting Supply Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

External Photos

Page1of4FCCID:2A4FVCBSHL74BLORBH ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity ExternalPhotosoftheEUT Fig.1 Fig.2 Page2of4FCCID:2A4FVCBSHL74BLORBH ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of4FCCID:2A4FVCBSHL74BLORBH ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of4FCCID:2A4FVCBSHL74BLORBH ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7

ID Label/Location Info

Page1of1FCCID:2A4FVCBSHL74BLORBH ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION (Size:L:3.0cmxW:2.5cm) LabelLocation Lowvoltagesmarthardscapepaverlight Model:CBSHL74BLORBH FCCID:2A4FVCBSHL74BLORBH

Internal Photos

Page1of4FCCID:2A4FVCBSHL74BLORBH ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity InternalPhotosoftheEUT Fig.1 Fig.2 Page2of4FCCID:2A4FVCBSHL74BLORBH ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of4FCCID:2A4FVCBSHL74BLORBH ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Antenna Page4of4FCCID:2A4FVCBSHL74BLORBH ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7

RF Exposure Info

Page 1 of 4 FCCID:2A4FVCBSHL74BLORBH ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCRFExposureEvaluation 1.ProductInformation FCCID2A4FVCBSHL74BLORBH ProductnameLowvoltagesmarthardscapepaverlight ModelnumberCBSHL74BLORBH AdditionalModelNo.CBSHL74BLWHH,CBSHL74BLBKH,CBSHL74BLBNH, CBSHL74BLXXH(“XX”representsthe26lettersof“A~Z”) ModelDeclarationPCBboard,structureandinternalofthesemodel(s)arethesame, Sonoadditionalmodelsweretested PowersupplyInput:DC12V ModulationTypeGFSKforBluetoothV5.1(DTS) AntennaTypePCBAntenna AntennaGain1.09dBi(Max.) Hardwareversion/ Softwareversion/ FCCOperationfrequency2402MHz-2480MHz ExposurecategoryGeneralpopulation/uncontrolledenvironment EUTTypeProductionUnit DeviceTypeMobileDevices 2.EvaluationMethod SystemsoperatingundertheprovisionsofFCC47CFRsectionshallbeoperatedinamannerthatensures thatthepublicisnotexposedtoradiofrequencyenergylevelinexcessoftheCommission’sguidelines. Inaccordancewith47CFRFCCPart2SubpartJ,section2.1091thisdevicehasbeendefinedasmobile devicewherebyadistanceof0.2mnormallycanbemaintainedbetweentheuserandthedevice,andbelow RFPermissibleExposurelimitshallcomplywith. InaccordancewithKDB447498D01forSimultaneoustransmissionMPEtestexclusionapplieswhenthesum oftheMPEratiosforallsimultaneoustransmittingantennasincorporatedinahostdevice,basedonthe calculated/estimated,numericallymodelledormeasuredfieldstrengthsorpowerdensity,is≤1.0.TheMPE ratioofeachantennaisdeterminedattheminimumtestseparationdistancerequiredbytheoperating configurationsandexposureconditionsofthehostdevice,accordingtotheratiooffieldstrengthsorpower densitytoMPElimit,atthetestfrequency.Eitherthemaximumpeakorspatiallyaveragedresultsfrom measurementsornumericalsimulationsmaybeusedtodeterminetheMPEratios.Spatialaveragingdoesnot applywhenMPEisestimatedusingsimplecalculationsbasedonfar-fieldplane-waveequivalentconditions. Theantennainstallationandoperatingrequirementsforthehostdevicemustmeettheminimumtest separationdistancesrequiredbyallantennas,inbothstandaloneandsimultaneoustransmissionoperations, tosatisfycompliance. Page 2 of 4 FCCID:2A4FVCBSHL74BLORBH ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 3.Limit 3.1ReferEvaluationMethod ANSIC95.1–1999:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoRadioFrequency ElectromagneticFields,3kHzto300GHz. FCCKDBpublication447498D01General1RFExposureGuidancev06:MobileandPortableDevicesRF ExposureProceduresandEquipmentAuthorizationPolicies. FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1091:Radiofrequencyradiationexposureevaluation:mobiledevices 3.2Limit LimitsforMaximumPermissibleExposure(MPE)/ControlledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100)* (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 LimitsforMaximumPermissibleExposure(MPE)/UncontrolledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100)* (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequencyinMHz *=Plane-waveequivalentpowerdensity 4.MPECalculationMethod PredicationofMPElimitatagivendistance Equationfrompage18ofOETBulletin65,Edition97-01 S=PG/4Ď€R² Where:S=powerdensity P=powerinputtoantenna G=powergainoftheantennainthedirectionofinterestrelativetoanisotropicradiator R=distancetothecenterofradiationoftheantenna 5.AntennaInformation PCBAntennacanonlyuseantennascertificatedasfollowsprovidedbymanufacturer; Internal Identification Antennatypeand antennanumber Operatefrequency band Maximumantenna gain Note AntennaPCBAntenna2400MHz-2500MHz1.09dBiBTAntenna Page 3 of 4 FCCID:2A4FVCBSHL74BLORBH ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 6.ConductedPower <BTLEMaxConductedPower> ModeChannelFrequency(MHz) MaxConductedPower (dBm) GFSK 02402-0.5 192440-0.43 392480-0.29 <BT2LEMaxConductedPower> ModeChannelFrequency(MHz) MaxConductedPower (dBm) GFSK 02402-0.47 192440-0.39 392480-0.26 7.ManufacturingTolerance <BTLE> GFSK(Peak) ChannelChannel0Channel19Channel39 Target(dBm)000 Tolerance±(dB)1.01.01.0 <BT2LE> GFSK(Peak) ChannelChannel0Channel19Channel39 Target(dBm)000 Tolerance±(dB)1.01.01.0 Page 4 of 4 FCCID:2A4FVCBSHL74BLORBH ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 8.MeasurementResults 8.1StandaloneMPE AsdeclaredbytheApplicant,theEUTisawirelessdeviceusedinafixapplication,atleast20cmfromany bodypartoftheuserornearbypersons;fromthemaximumEUTRFoutputpower,theminimumseparation distance,r=20cm,aswellasthegainoftheusedantennarefertoantennainformation,theRFpowerdensity canbeobtained. [Antenna] <BTLE> Band/Mode RFoutputpower AntennaGain (dBi) MPE (mW/cm2) MPE Limits (mW/cm2) dBmmW GFSK1.01.25891.090.00031.0000 <BT2LE> Band/Mode RFoutputpower AntennaGain (dBi) MPE (mW/cm2) MPE Limits (mW/cm2) dBmmW GFSK1.01.25891.090.00031.0000 Remark: 1.Outputpowerincludingtune-uptolerance; 2.MPEevaluatedistanceis20cmfromusermanualprovidebymanufacturer; 8.2Simultan…

Text truncated - open the document above for the full version.

Test Report

Page1of34FCCID:2A4FVCBSHL74BLORBHReportNo.:LCSA072822068EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity AppendixA RFTestDataforBTLE(ConductedMeasurement) ProductName:Lowvoltagesmarthardscapepaverlight TestModel:CBSHL74BLORBH EnvironmentalConditions Temperature: 23.8 ď‚° C RelativeHumidity:52.2% ATMPressure:100.0kPa TestEngineer: MonkeyLi Supervisedby: LiHuan Page2of34FCCID:2A4FVCBSHL74BLORBHReportNo.:LCSA072822068EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.1-6dBBandwidth ConditionModeFrequency(MHz)Antenna-6dBBandwidth(MHz)Limit-6dBBandwidth(MHz)Verdict NVNTBLE1M2402Ant10.658>=0.5Pass NVNTBLE1M2440Ant10.66>=0.5Pass NVNTBLE1M2480Ant10.7>=0.5Pass NVNTBLE2M2402Ant11.172>=0.5Pass NVNTBLE2M2440Ant11.177>=0.5Pass NVNTBLE2M2480Ant11.166>=0.5Pass Page3of34FCCID:2A4FVCBSHL74BLORBHReportNo.:LCSA072822068EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs -6dBBandwidthNVNTBLE1M2402MHzAnt1 -6dBBandwidthNVNTBLE1M2440MHzAnt1 Page4of34FCCID:2A4FVCBSHL74BLORBHReportNo.:LCSA072822068EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity -6dBBandwidthNVNTBLE1M2480MHzAnt1 -6dBBandwidthNVNTBLE2M2402MHzAnt1 Page5of34FCCID:2A4FVCBSHL74BLORBHReportNo.:LCSA072822068EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity -6dBBandwidthNVNTBLE2M2440MHzAnt1 -6dBBandwidthNVNTBLE2M2480MHzAnt1 Page6of34FCCID:2A4FVCBSHL74BLORBHReportNo.:LCSA072822068EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.2MaximumPeakConductedOutputPower ConditionModeFrequency (MHz) AntennaConductedPower (dBm) DutyFactor (dB) TotalPower (dBm) Limit (dBm) Verdict NVNTBLE1M2402Ant1-0.50-0.530Pass NVNTBLE1M2440Ant1-0.430-0.4330Pass NVNTBLE1M2480Ant1-0.290-0.2930Pass NVNTBLE2M2402Ant1-0.470-0.4730Pass NVNTBLE2M2440Ant1-0.390-0.3930Pass NVNTBLE2M2480Ant1-0.260-0.2630Pass Page7of34FCCID:2A4FVCBSHL74BLORBHReportNo.:LCSA072822068EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs PowerNVNTBLE1M2402MHzAnt1 PowerNVNTBLE1M2440MHzAnt1 Page8of34FCCID:2A4FVCBSHL74BLORBHReportNo.:LCSA072822068EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity PowerNVNTBLE1M2480MHzAnt1 PowerNVNTBLE2M2402MHzAnt1 Page9of34FCCID:2A4FVCBSHL74BLORBHReportNo.:LCSA072822068EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity PowerNVNTBLE2M2440MHzAnt1 PowerNVNTBLE2M2480MHzAnt1 Page10of34FCCID:2A4FVCBSHL74BLORBHReportNo.:LCSA072822068EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.3MaximumPowerSpectralDensityLevel ConditionModeFrequency (MHz) AntennaConductedPSD (dBm/3kHz) DutyFactor (dB) TotalPSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNTBLE1M2402Ant1-12.580-12.588Pass NVNTBLE1M2440Ant1-12.270-12.278Pass NVNTBLE1M2480Ant1-13.40-13.48Pass NVNTBLE2M2402Ant1-15.390-15.398Pass NVNTBLE2M2440Ant1-14.190-14.198Pass NVNTBLE2M2480Ant1-14.20-14.28Pass Page11of34FCCID:2A4FVCBSHL74BLORBHReportNo.:LCSA072822068EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs PSDNVNTBLE1M2402MHzAnt1 PSDNVNTBLE1M2440MHzAnt1 Page12of34FCCID:2A4FVCBSHL74BLORBHReportNo.:LCSA072822068EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity PSDNVNTBLE1M2480MHzAnt1 PSDNVNTBLE2M2402MHzAnt1 Page13of34FCCID:2A4FVCBSHL74BLORBHReportNo.:LCSA072822068EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity PSDNVNTBLE2M2440MHzAnt1 PSDNVNTBLE2M2480MHzAnt1 Page14of34FCCID:2A4FVCBSHL74BLORBHReportNo.:LCSA072822068EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,…

Text truncated - open the document above for the full version.

Test Report

Page1of32FCCID:2A4FVCBSHL74BLORBHReportNo.:LCSA072822068EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT For CloudyBayLightingSupplyInc Lowvoltagesmarthardscapepaverlight TestModel:CBSHL74BLORBH AdditionalModelNo.:PleaseRefertoPage6 Preparedfor:CloudyBayLightingSupplyInc Address:131217thStreetSuite692DenverCO80202UnitedStates Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:July30,2022 Numberoftestedsamples:2 SampleNo.:A072822068-1,A072822068-2 Serialnumber:Prototype DateofTest:July30,2022~August04,2022 DateofReport:August04,2022 Page2of32FCCID:2A4FVCBSHL74BLORBHReportNo.:LCSA072822068EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FCCCFR47PART15C(15.247) ReportReferenceNo......................:LCSA072822068EA DateofIssue.......................................:August04,2022 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China TestingLocation/Procedure............:FullapplicationofHarmonisedstandardsâ–  PartialapplicationofHarmonisedstandardsâ–ˇ Otherstandardtestingmethodâ–ˇ Applicant’sName.............................:CloudyBayLightingSupplyInc Address................................................:131217thStreetSuite692DenverCO80202UnitedStates TestSpecification Standard..............................................: FCCCFR47PART15C(15.247) TestReportFormNo......................:LCSEMC-1.0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceofthe material.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. EUTDescription...............................:Lowvoltagesmarthardscapepaverlight TradeMark..........................................:CloudyBay TestModel...........................................: CBSHL74BLORBH Ratings.................................................: Input:DC12V Result...................................................:Positive Compiledby:Supervisedby:Approvedby: RoryHuang/AdministratorCaryLuo/TechniqueprincipalGavinLiang/Manager Page3of32FCCID:2A4FVCBSHL74BLORBHReportNo.:LCSA072822068EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCC--TESTREPORT TestModel...............................:CBSHL74BLORBH EUT.........................................:Lowvoltagesmarthardscapepaverlight Applicant...............................:CloudyBayLightingSupplyInc Address..................................:131217thStreetSuite692DenverCO80202UnitedStates Telephone...............................:/ Fax..........................................:/ Manufacturer........................:CloudyBayLightingSupplyInc Address...................................:131217thStreetSuite692DenverCO80202UnitedStates Telephone...............................: / Fax..........................................: / Factory...................................:FoshanNanhaiPingyiElectronicCo.,Ltd Address...................................:No7,TaojinRoad,WujinIndustrialArea,DanzhaoTown,Nanhai District,FoshanCity,Guangdong,PRC528000 Telephone...............................:/ Fax..........................................:/ TestResultPositive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCSA072822068EA August04,2022 Dateofissue Page4of32FCCID:2A4FVCBSHL74BLORBHReportNo.:LCSA072822068EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000August04,2022InitialIssue-- Page5of32FCCID:2A4FVCBSHL74BLORBHReportNo.:LCSA072822068EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TABLEOFCONTENTS 1.GENERALINFORMATION........................................................................................................................6 1.1.DESCRIPTIONOFDEVICE(EUT).............................................................................................................6 1.2.HOSTSYSTEMCONFIGURATIONLISTANDDETAILS.................................................................................7 1.3.EXTERNALI/OCABLE.............................................................................................................................7 1.4…

Text truncated - open the document above for the full version.

Test Setup Photos

Page1of1FCCID:2A4FVCBSHL74BLORBH ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestSetupPhotosoftheEUT TestSetupPhoto(s)ofRadiatedEmissionsMeasurement Fig.1 Fig.2

Contact Information

Applicant

Larry Lee(Product Manager)
[email protected]281 201 8879Fax: 281 201 8879

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz900.00 µW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from Cloudy Bay Lighting Supply Inc

3 Inch RGB Smart Recessed Lighting with Gradient Accent Light and Night Light - FCC ID 2A4FVLJD005SMG2WH - Cloudy Bay Lighting Supply Inc
2A4FVLJD005SMG2WH

3 Inch RGB Smart Recessed Lighting with Gradient Accent Light and Night Light

Aug 23, 2024

Equipment Class

DTS - Digital Transmission System
3inch Wifi-BLE Narrow Flood Recessed Down Light - FCC ID 2A4FVLJD003NFSMWH - Cloudy Bay Lighting Supply Inc
2A4FVLJD003NFSMWH

3inch Wifi-BLE Narrow Flood Recessed Down Light

Jul 01, 2024

Equipment Class

DTS - Digital Transmission System
7 Inch Bluetooth Hardscape Light - FCC ID 2A4FVCBHL7BLORB - Cloudy Bay Lighting Supply Inc
2A4FVCBHL7BLORB

7 Inch Bluetooth Hardscape Light

Jun 16, 2024

Equipment Class

DTS - Digital Transmission System
12 Inch Wi-Fi Smart Semi Circle Wall light - FCC ID 2A4FVHM1215SMBN - Cloudy Bay Lighting Supply Inc
2A4FVHM1215SMBN

12 Inch Wi-Fi Smart Semi Circle Wall light

Aug 06, 2023

Equipment Class

DTS - Digital Transmission System
HIGH WATTAGE SMART LED TRACK HEAD - FCC ID 2A4FVLTHR006SMWH - Cloudy Bay Lighting Supply Inc
2A4FVLTHR006SMWH

HIGH WATTAGE SMART LED TRACK HEAD

Aug 06, 2023

Equipment Class

DTS - Digital Transmission System