Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Prepared by: Wei Fangying Approved by: Fan Guangchang Eurofins TA Technology (Shanghai) Co., Ltd. Building 3, No.145, Jintang Rd, Pudong Shanghai, P.R.China TEL: +86-021-50791141/2/3 FAX: +86-021-50791141/2/3-8000 MPE TEST REPORT Applicant Copeland Comfort Control Lp FCC ID 2A4JN-OS01-SG Product outdoor remote sensor Model OS01-SG Report No. R2407A0862-M1 Issue Date August 22, 2024 Eurofins TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in FCC 47 CFR Part 1 1.1310. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. MPE Test Report Report No.: R2407A0862-M1 Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-014S Page 2 of 9 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. Table of Contents 1 Test Laboratory ................................................................................................................................. 3 1.1 Notes of the Test Report ............................................................................................................ 3 1.2 Test Facility ................................................................................................................................ 3 1.3 Testing Location......................................................................................................................... 3 1.4 Laboratory Environment ............................................................................................................ 3 2 Description of Equipment Under Test ............................................................................................... 4 3 Maximum Output Power (Measured) and Antenna Gain .................................................................. 5 4 MPE Limit .......................................................................................................................................... 6 5 RF Exposure Evaluation Result ........................................................................................................ 8 ANNEX A: The EUT Appearance ............................................................................................................. 9 MPE Test Report Report No.: R2407A0862-M1 Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-014S Page 3 of 9 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. 1 Test Laboratory 1.1 Notes of the Test Report This report shall not be reproduced in full or partial, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. Measurement Uncertainties were not taken into account and are published for informational purposes only. This report is written to support regulatory compliance of the applicable standards stated above. 1.2 Test Facility FCC (Designation number: CN1179, Test Firm Registration Number: 446626) Eurofins TA Technology (Shanghai) Co., Ltd. has been listed on the US Federal Communications Commission list of test facilities recognized to perform measurements. 1.3 Testing Location Company: Eurofins TA Technology (Shanghai) Co., Ltd. Address: Building 3, No.145, Jintang Rd, Pudong Shanghai, P.R.China City: Shanghai Post code: 201201 Country: P. R. China Contact: Fan Guangchang Telephone: +86-021-50791141/2/3 Fax: +86-021-50791141/2/3-8000 Website: https://www.eurofins.com/electrical-and-electronics E-mail: [email protected] 1.4 Laboratory Environment Temperature Min. = 18C, Max. = 25C Relative humidity Min. = 20%, Max. = 80% Ground system resistance < 0.5 Ambient noise is checked and found very low and in compliance with requirement of standards. Reflection of surrounding objects is minimized and in compliance with requirement of standards. MPE Test Report Report No.: R2407A0862-M1 Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-014S Page 4 of 9 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. 2 Description of Equipment Under Test Client Information Applicant Copeland Comfort Control Lp Applicant address 8100 West Florissant Ave, St. Louis, MO 63136, United States Of America Manufacturer Copeland Comfort Control Lp Manufacturer address 8100 West Florissant Ave, St. Louis, MO 63136, United States Of America General Technologies EUT Description Model OS01-SG SN 537900132498973 Hardware Version 0059-5376 ver001 Software Version 0170-1583v02_03 Frequency Band TX (MHz) RX (MHz) Sub-G 902.46 ~ 927.54 902.46 ~ 927.54 Date of Testing July 30, 2024 ~ July 31, 2024 Date of Sample Received July 16, 2024 Note: 1. The EUT is sent from the applicant to Eurofins TA and the information of the EUT is declared by the applicant. 2. All indications of Pass/Fail in this report are opinions expressed by Eurofins TA Technology (Shanghai) Co., Ltd. based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into account and are published for informational purposes only. MPE Test Report Report No.: R2407A0862-M1 Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-014S Page 5 of 9 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. 3 Maximum Output Power (Measured) and Antenna Gain The numeric gain (G) of the antenna with a gain specified in dB is determined by Numeric gain (G)=10^(antenna gain/10) Band Maximum Output Power (Measured) Antenna Gain (dBi) Numeric Gain (dBm) (mW) Sub-G 17.74 59.429 -1.84 0.655 MPE Test Report Report No.: R2407A0862-M1 Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-014S Page 6 of 9 This report shall not be reproduced except in full, without the wr…
Text truncated - open the document above for the full version.
2402 OutdoorRSPhase1 Sub-' ŶƚĞŶŶĂ^ƉĞĐŝĮĐĂƟŽŶ Antenna Type:PCB Antenna Antenna Model Name:Outdoor RSphase1-Sub-G-Ant Antenna PCB manufacturer:HT SURE ADVANCE CIRCUITS (SHEN ZHEN) LTD. Address:Second Industrial Zone, Gonghe Village,Shajing Town, Baoan District, Shenzhen Antenna Photo: PCB Antenna Antenna Gain: Frequency/MHzAvgGain/dBi 902-1.89 903-1.86 904-1.85 905-2.08 906-2.15 907-2.22 908-2.26 909-2.25 910-1.84 911-1.85 912-1.89 913-1.92 914-1.97 915-2.05 916-2.08 917-2.16 918-2.27 919-2.19 920-2.3 921-2.38 922-2.01 923-1.98 924-1.91 925-1.84 926-1.87 927-1.95 928-2.07 929-2.23 930-3.43 Antenna 3D:
Prepared by: Xu Ying Approved by: Xu Kai Eurofins TA Technology (Shanghai) Co., Ltd. Building 3, No.145, Jintang Rd, Pudong Shanghai, P.R.China TEL: +86-021-50791141/2/3 FAX: +86-021-50791141/2/3-8000 RF TEST REPORT Applicant Copeland Comfort Control Lp FCC ID 2A4JN-OS01-SG Product outdoor remote sensor Model OS01-SG Report No. R2407A0862-R1 Issue Date August 22, 2024 Eurofins TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in FCC CFR47 Part 15C (2023). The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. RF Test Report Report No.: R2407A0862-R1 Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-04-004R Page 2 of 42 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. TABLE OF CONTENT 1 Test Laboratory ................................................................................................................................. 4 1.1 Notes of the Test Report ............................................................................................................ 4 1.2. Test facility ................................................................................................................................. 4 1.3 Testing Location......................................................................................................................... 4 2 General Description of Equipment under Test .................................................................................. 5 2.1 Applicant and Manufacturer Information ................................................................................... 5 2.2 General information ................................................................................................................... 5 3 Applied Standards ............................................................................................................................. 6 4 Information about the FHSS characteristics ..................................................................................... 7 4.1 Frequency Hopping System Requirement ................................................................................ 7 4.2 Test Configuration ...................................................................................................................... 8 5 Test Case Results ............................................................................................................................. 9 5.1 Power Output ............................................................................................................................. 9 5.2 Occupied Bandwidth (20dB) .................................................................................................... 11 5.3 Frequency Separation ............................................................................................................. 13 5.4 Time of Occupancy (Dwell Time) ............................................................................................. 15 5.5 Band Edge Compliance ........................................................................................................... 18 5.6 Number of hopping Frequency ................................................................................................ 21 5.7 Spurious RF Conducted Emissions ......................................................................................... 23 5.8 Unwanted Emission ................................................................................................................. 25 5.9 Conducted Emission ................................................................................................................ 38 6 Main Test Instruments ..................................................................................................................... 40 ANNEX A: The EUT Appearance ........................................................................................................... 41 ANNEX B: Test Setup Photos ................................................................................................................ 42 RF Test Report Report No.: R2407A0862-R1 Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-04-004R Page 3 of 42 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. Summary of Measurement Results Number Test Case Clause in FCC rules Verdict 1 Frequency Hopping System 15.247 (g), (h) PASS 2 Output Power 15.247(b)(2) PASS 3 Occupied Bandwidth (20dB) 15.247(a) (1) (i) PASS 4 Frequency Separation 15.247(a) (1) (i) PASS 5 Time of Occupancy (Dwell Time) 15.247(a) (1) (i) PASS 6 Band Edge Compliance 15.247(d) PASS 7 Number of Hopping Frequency 15.247(a) (1) (i) PASS 8 Spurious RF Conducted Emissions 15.247(d) PASS 9 Unwanted Emissions 15.247(d) PASS 10 Conducted Emissions 15.207 NA Note 1 Date of Testing: July 23, 2024 ~ July 31, 2024 Date of Sample Received: July 16, 2024 Note: PASS: The EUT complies with the essential requirements in the standard. FAIL: The EUT does not comply with the essential requirements in the standard. 1. The equipment is not connected to the public network, so test items do not apply. 2. All indications of Pass/Fail in this report are opinions expressed by Eurofins TA Technology (Shanghai) Co., Ltd. based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into account and are published for informational purposes only. RF Test Report Report No.: R2407A0862-R1 Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-04-004R Page 4 of 42 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. 1 Test Laboratory 1.1 Notes of the Test Report This report shall not be reproduced in full or partial, without the written approval of Eurofins…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 902.46 MHz - 927.54 MHz | 59.00 mW |

Sensi Touch 2 with BT and WiFi
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Sensi Touch 2 Smart Thermostat with BT and WiFi
Equipment Class
DTS - Digital Transmission System