Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 28, 2023
Application Purpose
Original Equipment
Date of Application
Jul 28, 2023
Equipment Note
Automatic Pet Feeder
Frequency Range
2412.00000000 - 2462.00000000
Company
Hangzhou Beiqu Technology Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Thank you for purchasing the Petree automatic feeder. Petree Technology is committed to making pet-raising life better through the power of design. This manual will help you better understand and use this product. Enjoy your using! 1 Automatic feeder host X 1 Bowl holder X 1 stainless steel bowl X 1 Instructions X 1Desiccant X 1Adapter X 1type-c X 1 2 pet automatic feeder Instruction manual Please read the instruction manual carefully before using the product2305 Top cap Food barrel Button Indicator Light Host Bowl holder Dinner bowl 1. Install the desiccant Open the fixed cover and put the desiccant into the slot. 2. Install the food barrel Press the host buckle with both hands at the same time, and the food barrel can be disassembled. 345 4. Disassemble the food barrel Rotate the leakage port. Then food barrel, stirring blades, and distributing blades can be disassembled and cleaned. Distributing bladesv Stirring blades Rotate to open the leakage port 3. Install the bowl and the holder Place the dinner bowl in the bowl holder, insert the bowl holder fixing part into the host positioning groove. host positioning grooves Bowl holder boss StatementProduct listProduct introductionInstallation instructions Notice to users Please check the product list and quantity carefully 1. Please install and use this product strictly according to the instructions. 2. This feeder is only suitable for dry food. Do not put wet food in. 3. The shape and size of food particles can cause a certain deviation in the weight of the food released. 4. Top cap, food barrel, and stainless steel bowl can be washed with water. The host and bowl holder are forbidden to wash. 5. Except for maintenance personnel, no one else is allowed to disassemble and repair this product. 6. Please use the battery safely. Improper use of the battery can cause electrolyte leakage and cause a fire. 7. Please use the battery safely. Improper use of the battery may cause electrolyte leakage and cause a fire. 8. Please keep the feeder away from heat sources, open flames, or other high-temperature countertops. 3. The life of the desiccant Petree pet automatic feeder ACF-23-02 186 x 318 x 326(mm) 1.8 KG 5V 1A GB4706.1-2005 1. The indicator light flashes red 1、Check whether the machine is short of food, please replenish it in time. 2、Please check whether the machine battery is low and replace the battery in time. 2. Indicator light staying red 1、Check whether food is stuck and clean up the blockage. 2、After troubleshooting, double-click the button to produce food normally. The desiccant of the feeder has a usage time of 30 days, which can extend the storage time of food. If the desiccant expires, please replace it in time. 3. Meal tray weighing function (Not available for non weighing feeders) (1)Display the remaining amount in the bowl. You can remotely check the condition of the feeder through the app, making it easy to observe and check feeding situation. (2)Display feeding data. The device records the weight of each pet's meal and generates a data table for you to update feeding plans. (3)Set the maximum food output. The feeder can set the maximum capacity of the bowl to avoid food accumulation and becoming stale. 2. Dismantling and washing equipment The components can be washed with water, except for the bowl holder and the host There are fixed switches on both sides of the barrel, which can be pressed to remove the barrel. Pour out the remaining food from the machine and twist open the leakage port, then you can clean the leakage port and the brush. 891011 Touch button Indicator light Single press White light Red light Double press Press for 3 seconds No response Always on flashing Device standby Distribution network Always on flashing Motor failure Lack of food/low battery power Release a portion of pet Enter the network configuration mode Distribution network Precautions for network distribution 1.Scan QR code to download the app 2.In standby mode, press and hold the button, the indicator light will flash quickly and enter the distribution network. 3.Open the app, follow the instructions to add devices and connect to the network. 4.After successful network distribution, the indicator light will stay white. 5.This product only supports 2.4G Wi-Fi and does not support 5G Wi-Fi. 6.When distributing the network, the phone needs to turn on Bluetooth. 7.If the app cannot discover the device, please power off the device for 5 seconds and then power it on and restart. 8.A device can only be bound to one account. 6 Button and light descriptions Double press the button to release one portion 1. Manual feeding function Double press the button to release one portion of the food. If multiple portions are needed, the operation can be repeated. 2. Automatic food dispensing function Connect the device to the app and set a feeding plan in the app. The feeder will automatically release food by the plan every day. Notification information of feeding will be sent on time. (1) The feeder is suitable for: puffed pet food, freeze-dried food. (2) Maximum supported freeze-drying size: 14 * 14 * 14mm. (3) Do not put oversized particles in. 015 15 10 10 5 5 7 Function description Quick troubleshooting Cleaning instructionsHazardous Substance Description Product parameters After cleaning, wait air drying to complete. And then install the barrel, the bowl holder, and the bowl in sequence. 3. Dry out and install Product name Product model size net weight Rated voltage Execution standards 1. Disassemble the machine Washable Non washable FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference t…

Text truncated - open the document above for the full version.

External Photos

APF-23-01

Internal Photos

APF-23-01

RF Exposure Info

Page 1 of 8 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Add:BuildingC,No.107,ShihuanRoad,ShiyanSub-District,BaoanDistrict,Shenzhen,GuangdongProvince,China Tel:+86-755-23059481Email:[email protected] TESTREPORT ProductName: AutomaticPetFeeder BrandMark: N/A ModelNo.: APF-23-01 ExtensionModel: APF-23-02 FCCID: 2A4L9-APF2301 ReportNumber: BLA-EMC-202306-A11804 DateofSampleReceipt: 2023/6/29 DateofTest: 2023/6/30to2023/7/19 DateofIssue: 2023/7/19 TestStandard: 47CFRPart15,Part1.1307 47CFRPart15,Part2.1093 KDB447498D04GeneralRFExposure Guidancev01 TestResult:Pass Preparedfor: HangzhouBeiquTechnologyCo.,Ltd 1-306JinshaLakeCommercialCenter,QiantangNewDistrict, Hangzhou,Zhejiang Preparedby: BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. BuildingC,No.107,ShihuanRoad,ShiyanSub-District,BaoanDistrict, Shenzhen,GuangdongProvince,China TEL:+86-755-23059481 Compiledby:Reviewby: Approvedby:Date:2023/7/19 ReportNo.:BLA-EMC-202306-A11804 Page 2 of 8 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] REPORTREVISERECORD VersionNo.DateDescription 002023/7/19Original ReportNo.:BLA-EMC-202306-A11804 Page 3 of 8 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] TABLEOFCONTENTS 1TESTSUMMARY..............................................................................................................................................4 2GENERALINFORMATION...............................................................................................................................5 3GENERALDESCRIPTIONOFE.U.T................................................................................................................5 4LABORATORYLOCATION..............................................................................................................................6 5RFEXPOSURECOMPLIANCEREQUIREMENT............................................................................................7 5.1STANDARDREQUIREMENT..................................................................................................................................................7 5.2LIMITS............................................................................................................................................................................7 ReportNo.:BLA-EMC-202306-A11804 Page 4 of 8 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] 1TESTSUMMARY TestitemTestRequirementTestMethodClass/SeverityResult RFExposure 47CFRPart1.1307, Part2.1093,KDB 447498 CFR47Part2.1093CFR47Part2.1093PASS ReportNo.:BLA-EMC-202306-A11804 Page 5 of 8 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] 2GENERALINFORMATION ApplicantHangzhouBeiquTechnologyCo.,Ltd Address 1-306JinshaLakeCommercialCenter,QiantangNewDistrict, Hangzhou,Zhejiang ManufacturerHangzhouBeiquTechnologyCo.,Ltd Address 1-306JinshaLakeCommercialCenter,QiantangNewDistrict, Hangzhou,Zhejiang FactoryZhejiangDaxiongMouldIndustryCo.,Ltd AddressXichengMouldCity,HuangyanDistrict,Taizhou,Zhejiang ProductNameAutomaticPetFeeder TestModelNo.APF-23-01 ExtensionModelAPF-23-02 RemarkWithorwithoutweightsensor 3GENERALDESCRIPTIONOFE.U.T. HardwareVersionN/A SoftwareVersionN/A OperationFrequency: BLE:2402MHz-2480MHz 2.4GWIFI:802.11b/g/n(HT20):2412MHzto2462MHz ModulationType: BLE:GFSK 2.4GWIFI:802.11b:DSSS(CCK,DQPSK,DBPSK) 802.11g/n:OFDM(64QAM,16QAM,QPSK,BPSK) ChannelSpacing: BLE:2MHz 2.4GWIF:5MHz NumberofChannels: BLE:40 2.4GWIFI:802.11b/g/n(HT20):11 AntennaType:PCBAntenna AntennaGain:2.5dBi(Providedbythecustomer) ReportNo.:BLA-EMC-202306-A11804 Page 6 of 8 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] 4LABORATORYLOCATION Alltestswereperformedat: BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. BuildingC,No.107,ShihuanRoad,ShiyanSub-District,BaoanDistrict,Shenzhen,GuangdongProvince,China Telephone:TEL:+86-755-28682673FAX:+86-755-28682673 Notestsweresub-contracted. ReportNo.:BLA-EMC-202306-A11804 Page 7 of 8 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] 5RFEXPOSURECOMPLIANCEREQUIREMENT 5.1STANDARDREQUIREMENT Accordingto447498D04InterimGeneralRFExposureGuidancev01 StandaloneSARtestexclusionconsiderations UnlessspecificallyrequiredbythepublishedRFexposureKDBprocedures,standalone1-gheador bodyand10-gextremitySARevaluationforgeneralpopulationexposureconditions,bymeasurementor numericalsimulation,isnotrequiredwhenthecorrespondingSARExclusionThresholdcondition, listedbelow,issatisfied. 5.2LIMITS ReportNo.:BLA-EMC-202306-A11804 Page 8 of 8 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] EIRP=pt×gt=(E×d)2/30 where: pt=transmitteroutputpowerinwatts, gt=numericgainofthetransmittingantenna(unitless), E=electricfieldstrengthinV/m,---10((dBuV/m)/20)/106 d=measurementdistanceinmeters(m)---3m Sopt=(E×d)2/30×gt Antgain=2.5dBi BLE: MaxOutputpower=1.726dBm@2480MHz ERP=1.726dBm+2.5Bi-2.15=2.076dBm So worsecase: 10^0.2076=1.613mW<3060mW ComplywithRFexposureexemptionlimit. 2.4GWIFI: MaxOutputpower=17.292dBm@11b2462MHz ERP=17.292dBm+2.5Bi-2.15=17.642dBm So worsecase: 10^1.7642=58.103mW<3060mW ComplywithRFexposureexemptionlimit. ----ENDOFREPORT---- Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthis reportreferonlytothesample(s)tested.WithoutwrittenapprovalofBlueAsia,thisreportcan’tbe reproducedexceptinfull.

Test Report

Page 1 of 60 BlueAsia of Technical Services(Shenzhen) Co.,Ltd. Add: Building C, No. 107, Shihuan Road, Shiyan Sub-District, Baoan District, Shenzhen, Guangdong Province, China Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com TEST REPORT Product Name: Automatic Pet Feeder Brand Mark: N/A Model No.: APF-23-01 Extension Model: APF-23-02 Report Number: BLA-EMC-202306-A11803 FCC ID: 2A4L9-APF2301 Date of Sample Receipt: 2023/6/29 Date of Test: 2023/6/30 to 2023/7/19 Date of Issue: 2023/7/19 Test Standard: 47 CFR Part 15, Subpart C 15.247 Test Result:Pass Prepared for: Hangzhou Beiqu Technology Co., Ltd 1-306 Jinsha Lake Commercial Center, Qiantang New District, Hangzhou, Zhejiang Prepared by: BlueAsia of Technical Services(Shenzhen) Co.,Ltd. Building C, No. 107, Shihuan Road, Shiyan Sub-District, Baoan District, Shenzhen, Guangdong Province, China TEL: +86-755-23059481 Compiled by:Review by: Approved by:Date:2023/7/19 Report No.: BLA-EMC-202306-A11803 Page 2 of 60 BlueAsia of Technical Services(Shenzhen) Co.,Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com REPORT REVISE RECORD Version No.DateDescription 002023/7/19Original Report No.: BLA-EMC-202306-A11803 Page 3 of 60 BlueAsia of Technical Services(Shenzhen) Co.,Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com TABLE OF CONTENTS 1 TEST SUMMARY.............................................................................................................................................. 5 2 GENERAL INFORMATION...............................................................................................................................6 3 GENERAL DESCRIPTION OF E.U.T................................................................................................................6 4 TEST ENVIRONMENT...................................................................................................................................... 7 5 TEST MODE......................................................................................................................................................7 6 MEASUREMENT UNCERTAINTY....................................................................................................................7 7 DESCRIPTION OF SUPPORT UNIT................................................................................................................ 8 8 LABORATORY LOCATION.............................................................................................................................. 8 9 TEST INSTRUMENTS LIST..............................................................................................................................9 10 CONDUCTED PEAK OUTPUT POWER......................................................................................................12 10.1 LIMITS...................................................................................................................................................................... 12 10.2 BLOCK DIAGRAM OF TEST SETUP............................................................................................................................ 12 10.3 TEST DATA..................................................................................................................................................................13 11 MINIMUM 6DB BANDWIDTH....................................................................................................................... 14 11.1 LIMITS...................................................................................................................................................................... 14 11.2 BLOCK DIAGRAM OF TEST SETUP............................................................................................................................ 14 11.3 TEST DATA..................................................................................................................................................................14 12 ANTENNA REQUIREMENT..........................................................................................................................15 12.1 CONCLUSION............................................................................................................................................................... 15 13 CONDUCTED EMISSIONS AT AC POWER LINE (150KHZ-30MHZ).........................................................16 13.1 LIMITS...................................................................................................................................................................... 16 13.2 BLOCK DIAGRAM OF TEST SETUP............................................................................................................................ 16 13.3 PROCEDURE............................................................................................................................................................. 16 13.4 TEST DATA..................................................................................................................................................................18 14 CONDUCTED BAND EDGES MEASUREMENT.........................................................................................20 14.1 LIMITS...................................................................................................................................................................... 20 14.2 BLOCK DIAGRAM OF TEST SETUP............................................................................................................................ 21 14.3 TEST DATA..................................................................................................................................................................21 15 RADIATED SPURIOUS EMISSIONS........................................................................................................... 22 Report No.: BLA-EMC-202306…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 91 BlueAsia of Technical Services(Shenzhen) Co.,Ltd. Add: Building C, No. 107, Shihuan Road, Shiyan Sub-District, Baoan District, Shenzhen, Guangdong Province, China Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com TEST REPORT Product Name: Automatic Pet Feeder Brand Mark: N/A Model No.: APF-23-01 Extension Model: APF-23-02 Report Number: BLA-EMC-202306-A11802 FCC ID: 2A4L9-APF2301 Date of Sample Receipt: 2023/6/29 Date of Test: 2023/6/30 to 2023/7/19 Date of Issue: 2023/7/19 Test Standard: 47 CFR Part 15, Subpart C 15.247 Test Result:Pass Prepared for: Hangzhou Beiqu Technology Co., Ltd 1-306 Jinsha Lake Commercial Center, Qiantang New District, Hangzhou, Zhejiang Prepared by: BlueAsia of Technical Services(Shenzhen) Co.,Ltd. Building C, No. 107, Shihuan Road, Shiyan Sub-District, Baoan District, Shenzhen, Guangdong Province, China TEL: +86-755-23059481 Compiled by:Review by: Approved by:Date:2023/7/19 Report No.: BLA-EMC-202306-A11802 Page 2 of 91 BlueAsia of Technical Services(Shenzhen) Co.,Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com REPORT REVISE RECORD Version No.DateDescription 002023/7/19Original Report No.: BLA-EMC-202306-A11802 Page 3 of 91 BlueAsia of Technical Services(Shenzhen) Co.,Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com TABLE OF CONTENTS 1 TEST SUMMARY.............................................................................................................................................. 5 2 GENERAL INFORMATION...............................................................................................................................6 3 GENERAL DESCRIPTION OF E.U.T................................................................................................................6 4 TEST ENVIRONMENT...................................................................................................................................... 7 5 TEST MODE......................................................................................................................................................7 6 MEASUREMENT UNCERTAINTY....................................................................................................................7 7 DESCRIPTION OF SUPPORT UNIT................................................................................................................ 8 8 LABORATORY LOCATION.............................................................................................................................. 8 9 TEST INSTRUMENTS LIST..............................................................................................................................9 10 RADIATED SPURIOUS EMISSIONS........................................................................................................... 12 10.1 LIMITS...................................................................................................................................................................... 12 10.2 BLOCK DIAGRAM OF TEST SETUP............................................................................................................................ 13 10.3 PROCEDURE............................................................................................................................................................. 13 10.4 TEST DATA..................................................................................................................................................................15 11 ANTENNA REQUIREMENT..........................................................................................................................23 11.1 CONCLUSION............................................................................................................................................................... 23 12 RADIATED EMISSIONS WHICH FALL IN THE RESTRICTED BANDS.....................................................24 12.1 LIMITS...................................................................................................................................................................... 24 12.2 BLOCK DIAGRAM OF TEST SETUP............................................................................................................................ 25 12.3 PROCEDURE............................................................................................................................................................. 25 12.4 TEST DATA..................................................................................................................................................................27 13 CONDUCTED SPURIOUS EMISSIONS.......................................................................................................39 13.1 LIMITS...................................................................................................................................................................... 39 13.2 BLOCK DIAGRAM OF TEST SETUP............................................................................................................................ 40 13.3 TEST DATA..................................................................................................................................................................40 14 CONDUCTED BAND EDGES MEASUREMENT.........................................................................................41 14.1 LIMITS...................................................................................................................................................................... 41 14.2 BLOCK DIAGRAM OF TEST SETUP............................................................................................................................ 42 14.3 TEST DATA..................................................................................................................................................................4…

Text truncated - open the document above for the full version.

Test Report

Report No.: BLA-EMC-202306-A11802 Page 51 of 91 BlueAsia of Technical Services(Shenzhen) Co.,Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 3. Final Level =Receiver Read level + LISN Factor + Cable Loss. Report No.: BLA-EMC-202306-A11802 Page 52 of 91 BlueAsia of Technical Services(Shenzhen) Co.,Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 19 APPENDIX Appendix1 19.1 MAXIMUM CONDUCTED OUTPUT POWER ConditionModeFrequency (MHz)AntennaConducted Power (dBm)Limit (dBm)Verdict NVNTb2412Ant116.87030Pass NVNTb2437Ant116.61030Pass NVNTb2462Ant117.20030Pass NVNTg2412Ant116.73630Pass NVNTg2437Ant116.80530Pass NVNTg2462Ant117.29230Pass NVNTn202412Ant116.6830Pass NVNTn202437Ant116.76330Pass NVNTn202462Ant117.19130Pass Power NVNT b 2412MHzAnt1 Report No.: BLA-EMC-202306-A11802 Page 53 of 91 BlueAsia of Technical Services(Shenzhen) Co.,Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com Power NVNT b 2437MHzAnt1 Power NVNT b 2462MHzAnt1 Report No.: BLA-EMC-202306-A11802 Page 54 of 91 BlueAsia of Technical Services(Shenzhen) Co.,Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com Power NVNT g 2412MHzAnt1 Power NVNT g 2437MHzAnt1 Report No.: BLA-EMC-202306-A11802 Page 55 of 91 BlueAsia of Technical Services(Shenzhen) Co.,Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com Power NVNT g 2462MHzAnt1 Power NVNT n20 2412MHzAnt1 Report No.: BLA-EMC-202306-A11802 Page 56 of 91 BlueAsia of Technical Services(Shenzhen) Co.,Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com Power NVNT n20 2437MHzAnt1 Power NVNT n20 2462MHzAnt1 Report No.: BLA-EMC-202306-A11802 Page 57 of 91 BlueAsia of Technical Services(Shenzhen) Co.,Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 19.2 -6DB BANDWIDTH ConditionModeFrequency (MHz) Antenna-6 dB Bandwidth (MHz) Limit -6 dB Bandwidth (MHz) Verdict NVNTb2412Ant19.0960.5Pass NVNTb2437Ant19.0460.5Pass NVNTb2462Ant19.060.5Pass NVNTg2412Ant116.1560.5Pass NVNTg2437Ant116.3470.5Pass NVNTg2462Ant116.320.5Pass NVNTn202412Ant117.5730.5Pass NVNTn202437Ant117.5710.5Pass NVNTn202462Ant117.5560.5Pass -6dB Bandwidth NVNT b 2412MHzAnt1 Report No.: BLA-EMC-202306-A11802 Page 58 of 91 BlueAsia of Technical Services(Shenzhen) Co.,Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com -6dB Bandwidth NVNT b 2437MHzAnt1 -6dB Bandwidth NVNT b 2462MHzAnt1 Report No.: BLA-EMC-202306-A11802 Page 59 of 91 BlueAsia of Technical Services(Shenzhen) Co.,Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com -6dB Bandwidth NVNT g 2412MHzAnt1 -6dB Bandwidth NVNT g 2437MHzAnt1 Report No.: BLA-EMC-202306-A11802 Page 60 of 91 BlueAsia of Technical Services(Shenzhen) Co.,Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com -6dB Bandwidth NVNT g 2462MHzAnt1 -6dB Bandwidth NVNT n20 2412MHzAnt1 Report No.: BLA-EMC-202306-A11802 Page 61 of 91 BlueAsia of Technical Services(Shenzhen) Co.,Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com -6dB Bandwidth NVNT n20 2437MHzAnt1 -6dB Bandwidth NVNT n20 2462MHzAnt1 Report No.: BLA-EMC-202306-A11802 Page 62 of 91 BlueAsia of Technical Services(Shenzhen) Co.,Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 19.3 OCCUPIED CHANNEL BANDWIDTH ConditionModeFrequency (MHz)Antenna99% OBW (MHz) NVNTb2412Ant114.066 NVNTb2437Ant114.096 NVNTb2462Ant114.069 NVNTg2412Ant116.608 NVNTg2437Ant116.632 NVNTg2462Ant116.592 NVNTn202412Ant117.695 NVNTn202437Ant117.754 NVNTn202462Ant117.749 OBW NVNT b 2412MHzAnt1 Report No.: BLA-EMC-202306-A11802 Page 63 of 91 BlueAsia of Technical Services(Shenzhen) Co.,Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com OBW NVNT b 2437MHzAnt1 OBW NVNT b 2462MHzAnt1 Report No.: BLA-EMC-202306-A11802 Page 64 of 91 BlueAsia of Technical Services(Shenzhen) Co.,Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com OBW NVNT g 2412MHzAnt1 OBW NVNT g 2437MHzAnt1 Report No.: BLA-EMC-202306-A11802 Page 65 of 91 BlueAsia of Technical Services(Shenzhen) Co.,Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com OBW NVNT g 2462MHzAnt1 OBW NVNT n20 2412MHzAnt1 Report No.: BLA-EMC-202306-A11802 Page 66 of 91 BlueAsia of Technical Services(Shenzhen) Co.,Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com OBW NVNT n20 2437MHzAnt1 OBW NVNT n20 2462MHzAnt1 Report No.: BLA-EMC-202306-A11802 Page 67 of 91 BlueAsia of Technical Services(Shenzhen) Co.,Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 19.4 MAXIMUM POWER SPECTRAL DENSITY LEVEL ConditionModeFrequency (MHz)AntennaMax PSD (dBm)Limit (dBm)Verdict NVNTb2412Ant1-6.9088Pass NVNTb2437Ant1-5.7218Pass NVNTb2462Ant1-7.2278Pass NVNTg2412Ant1-13.1598Pass NVNTg2437Ant1-12.2428Pass NVNTg2462Ant1-12.178Pass NVNTn202412Ant1-12.0688Pass NVNTn202437Ant1-12.5648Pass NVNTn202462Ant1-11.4088Pass PSD NVNT b 2412MHzAnt1 Report No.: BLA-EMC-202306-A11802 Page 68 of 91 BlueAsia of Technical Services(Shenzhen) Co.,Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com PSD NVNT b 2437MHzAnt1 PSD NVNT b 2462MHzAnt1 Report No.: BLA-EMC-202306-A11802 Page 69 of 91 BlueAsia of Technical Services(Shenzhen) Co.,Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com PSD NVNT g 2412MHzAnt1 PSD NVNT g 2437MHzAnt1 Report No.: BLA-EMC-202306-A11802 Page 70 of 91 BlueAsia of Technical Services(Shenzhen) Co.,Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com PSD NVNT g 2462MHzAnt1 PSD NVNT n20 2412MHzAnt1 Report No.: BLA-EMC-202306-A11802 Page 71 of 91 BlueAsia of Technical Services(Shenzhen) Co.,Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com PSD NVNT n20 2437MHzAnt1 PSD NVNT n20 2462MHzAnt1 Report No.: BLA-EMC-202306-A11802 Page 72 of 91 BlueAsia of Technical Servic…

Text truncated - open the document above for the full version.

Test Report

AntennaSpecification Manufacture:TUYA ProductName:WBR3Antenna AntennaType:PCB TestDate:2021.05.20 Testedby:LongWang Approvedby:Licco Content 1.GeneralDescription.................................................................................1 2.TestConfigurations...................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Ye qing
[email protected]15858279866Fax: 15858279866

Test Firm

BlueAsia of Technical Services (Shenzhen)Blue Zheng
[email protected]+86 755-23059481-815

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz53.60 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be colocated or operating in conjunction with any other antenna or transmitter, except the co-location described in this filing or in accordance with FCC multitransmitter product procedures. End-users must be provided with instructions and operating conditions for satisfying RF exposure compliance.