FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Marvel Technology(China)Co.,Ltd/
  3. 2A4MW-MWE-CS3209

2A4MW-MWE-CS3209Touch Inquiry Machine

Marvel Technology(China)Co.,Ltd
Touch Inquiry Machine - FCC ID 2A4MW-MWE-CS3209 - Marvel Technology(China)Co.,Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Dec 17, 2025
Application Purpose
Original Equipment
Equipment Note
Touch Inquiry Machine
Frequency Range
2402.00000000 - 2480.00000000
Company
Marvel Technology(China)Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

RF Exposure Info

Shenzhen Toby Technology Co., Ltd. Report No.: TBR-C-202510-0082-1 Page: 1 of 8 TB-RF-074-1.0 1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China Tel: +86 75526509301 Fax: +86 75526509195 Maximum Permissible Exposure Evaluation FCC ID: 2A4MW-MWE-CS3209 Report No. : TBR-C-202510-0082-1 Applicant : Marvel Technology(China) Co., Ltd Equipment Under Test (EUT) EUT Name : Touch Inquiry Machine Model No. : MWE-CS3209 Series Model No. : MWE-CS2209, MWE-CS5509, MWE-CS6509 Brand Name : MWE Sample ID : HC-C-202510-0082-01-01-1#&HC-C-202510-0082-01-01-2# Receipt Date : 2025-10-24 Test Date : 2025-10-24 to 2025-11-27 Issue Date : 2025-11-27 Standards : FCC Part 2.1091 Test Method : KDB 447498 D01 General RF Exposure Guidance v06 Conclusions : PASS In the configuration tested, the EUT complied with the standards specified above. Test By : Gold. zhang Reviewed By : Wade. Lv Approved By : Ivan Su This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in the report. Report No.: TBR-C-202510-0082-1 Page: 2 of 8 TB-RF-074-1.0 CONTENTS CONTENTS ............................................................................................................................................. 2 1. GENERAL INFORMATION ABOUT EUT.............................................................................. 4 1.1 Client Information ................................................................................................................. 4 1.2 General Description of EUT (Equipment Under Test) ................................................... 4 2. MEASUREMENT UNCERTAINTY .......................................................................................... 5 3. TEST FACILITY.......................................................................................................................... 6 4. METHOD OF MEASUREMENT FOR FCC............................................................................ 7 5. TEST RESULT............................................................................................................................ 8 Report No.: TBR-C-202510-0082-1 Page: 3 of 8 TB-RF-074-1.0 Revision History Report No. Version Description Issued Date TBR-C-202510-0082-1 Rev.01 Initial issue of report 2025-11-27 Report No.: TBR-C-202510-0082-1 Page: 4 of 8 TB-RF-074-1.0 1. General Information about EUT 1.1 Client Information Applicant : Marvel Technology(China) Co., Ltd Address : Block 14, Longbi Industrial Park, No 27 Dafa Rd, Bantian LongGang District, Shenzhen, China Manufacturer : Marvel Technology(China) Co., Ltd Address : Block 14, Longbi Industrial Park, No 27 Dafa Rd, Bantian LongGang District, Shenzhen, China 1.2 General Description of EUT (Equipment Under Test) EUT Name : Touch Inquiry Machine Models No. : MWE-CS3209, MWE-CS2209, MWE-CS5509, MWE-CS6509 Model Different : All these models are identical in the same PCB layout and electrical circuit, only difference is model name. Product Description : Operation Frequency: Bluetooth V5.1: 2402MHz~2480MHz 802.11b/g/n(HT20): 2412MHz~2462MHz 802.11n(HT40): 2422MHz~2452MHz U-NII-1: 5180MHz~5240MHz U-NII-2A: 5260MHz~5320MHz U-NII-2C: 5500MHz~5700MHz U-NII-3: 5745MHz~5825MHz Modulation Type: GFSK(1Mbps&2Mbps) π/4-DQPSK(2Mbps) 8-DPSK(3Mbps) 802.11b: DSSS (DQPSK, DBPSK, CCK) 802.11g: OFDM (BPSK, QPSK,16QAM, 64QAM) 802.11a: OFDM (QPSK, BPSK, 16QAM) 802.11n: OFDM (QPSK, BPSK, 16QAM, 64QAM) 802.11ac: OFDM (QPSK, BPSK, 16QAM, 64QAM, 256QAM) Antenna Gain: 1.57dBi Dipole Antenna for BT & 2.4G WIFI 3.54dBi Dipole Antenna for 5G WIFI Power Rating : AC 100-240V Software Version : 1.0.1 Hardware Version : 1.0.3 Remark: The above antenna information is declared by manufacturer and for more detailed features description, please refer to the manufacturer's specifications, the laboratory shall not be held responsible. Report No.: TBR-C-202510-0082-1 Page: 5 of 8 TB-RF-074-1.0 2. Measurement Uncertainty The reported uncertainty of measurement y±U,where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %. Test Item Parameters Expanded Uncertainty (ULab) Conducted Emission Level Accuracy: 9kHz~150kHz 150kHz to 30MHz ±3.50 dB ±3.10 dB Radiated Emission Level Accuracy: 9kHz to 30 MHz ±4.60 dB Radiated Emission Level Accuracy: 30MHz to 1000 MHz ±4.50 dB Radiated Emission Level Accuracy: Above 1000MHz ±4.20 dB RF Power-Conducted Level Accuracy: Above 1000MHz ±0.95 dB Power Spectral Density- Conducted Level Accuracy: Above 1000MHz ±3dB Occupied Bandwidth Level Accuracy: 30MHz to 1000 MHz Above 1000MHz ±3.8% Unwanted Emission- Conducted Level Accuracy: 30MHz to 1000 MHz Above 1000MHz ±2.72 dB Temperature / ±0.6°C Humidity / ±4% Supply voltages / ±2% Time / ±4% Report No.: TBR-C-202510-0082-1 Page: 6 of 8 TB-RF-074-1.0 3. Test Facility The testing report were performed by the Shenzhen Toby Technology Co., Ltd., in their facilities located at 1/F., Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. At the time of testing, the following bodies accredited the Laboratory: CNAS (L5813) The Laboratory has been accredited by CNAS to ISO/IEC 17025: 2017 General Requirements for the Competence of Testing and Calibration Laboratories for the competence in the field of testing. And the Registration No.: CNAS L5813. A2LA Certificate No.: 4750.01 The laboratory has been accredited by American Association for Laboratory Accreditation(A2LA) to ISO/IEC 17025:2017 General Requirements for the Competence of Testing and Calibration Laboratories for the technical competence in the field of Electrical Testing. And the A2LA Certificate No.: 4750.01.FCC Accredit…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: 2A4MW-MWE-CS3209 TB-RF-074-1.0 Appendix V EUT Test Photographs Photo of Setup for Conducted Emission Photo of Setup for Radiated Emission (Below 1 GHz) FCC ID: 2A4MW-MWE-CS3209 TB-RF-074-1.0 Photo of Setup for Radiated Emission (Above 1 GHz) Photo of Setup for Radiated Emission (Above 1 GHz) FCC ID: 2A4MW-MWE-CS3209 TB-RF-074-1.0 Photo of Setup for RF Conducted----BT FCC ID: 2A4MW-MWE-CS3209 TB-RF-074-1.0 Photo of Setup for RF Conducted----WIFI Photo of Setup for DFS -----END OF THE REPORT-----

Test Report

Shenzhen Toby Technology Co., Ltd. Report No.: TBR-C-202510-0082-32 Page: 1 of 36 TB-RF-074-1.0 1/F., Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China Tel: +86 75526509301 Fax: +86 75526509195 RF Test Report FCC ID: 2A4MW-MWE-CS3209 Report No. : TBR-C-202510-0082-32 Applicant : Marvel Technology(China) Co., Ltd Equipment Under Test (EUT) EUT Name : Touch Inquiry Machine Model No. : MWE-CS3209 Series Model No. : MWE-CS2209, MWE-CS5509, MWE-CS6509 Brand Name : MWE Sample ID : HC-C-202510-0082-01-01-1#&HC-C-202510-0082-01-01-2# Receipt Date : 2025-10-24 Test Date : 2025-10-24 to 2025-11-27 Issue Date : 2025-11-27 Standards : FCC Part 15 Subpart C 15.247 Test Method : ANSI C63.10:2020+Cor.1:2023 KDB 558074 D01 15.247 Meas Guidance v05r02 Conclusions : PASS In the configuration tested, the EUT complied with the standards specified above. Tested By : Gold. zhang Reviewed By : Wade. Lv Approved By : Ivan Su This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in the report. Report No.: TBR-C-202510-0082-32 Page: 2 of 36 TB-RF-074-1.0 Contents CONTENTS ............................................................................................................................................. 2 1. GENERAL INFORMATION ABOUT EUT.............................................................................. 5 1.1 Client Information ................................................................................................................. 5 1.2 General Description of EUT (Equipment Under Test) ................................................... 5 1.3 Block Diagram Showing the Configuration of System Tested ...................................... 7 1.4 Description of Support Units .............................................................................................. 7 1.5 Description of Test Mode .................................................................................................... 8 1.6 Description of Test Software Setting ................................................................................ 9 1.7 Measurement Uncertainty ................................................................................................ 10 1.8 Test Facility ......................................................................................................................... 11 2. TEST SUMMARY ..................................................................................................................... 12 3. TEST SOFTWARE ................................................................................................................... 12 4. TEST EQUIPMENT AND TEST SITE ................................................................................... 13 5. CONDUCTED EMISSION TEST ........................................................................................... 15 5.1 Test Standard and Limit .................................................................................................... 15 5.2 Test Setup ........................................................................................................................... 15 5.3 Test Procedure ................................................................................................................... 15 5.4 Deviation From Test Standard ......................................................................................... 16 5.5 EUT Operating Mode ........................................................................................................ 16 5.6 Test Data ............................................................................................................................. 16 6. RADIATED AND CONDUCTED UNWANTED EMISSIONS ............................................ 17 6.1 Test Standard and Limit .................................................................................................... 17 6.2 Test Setup ........................................................................................................................... 19 6.3 Test Procedure ................................................................................................................... 20 6.4 Deviation From Test Standard ......................................................................................... 21 6.5 EUT Operating Mode ........................................................................................................ 21 6.6 Test Data ............................................................................................................................. 21 7. RESTRICTED BANDS REQUIREMENT ............................................................................. 22 7.1 Test Standard and Limit .................................................................................................... 22 7.2 Test Setup ........................................................................................................................... 22 7.3 Test Procedure ................................................................................................................... 23 7.4 Deviation From Test Standard ......................................................................................... 24 Report No.: TBR-C-202510-0082-32 Page: 3 of 36 TB-RF-074-1.0 7.5 EUT Operating Mode ........................................................................................................ 24 7.6 Test Data ............................................................................................................................. 24 8. BANDWIDTH TEST ................................................................................................................. 25 8.1 Test Standard and Limit .....…

Text truncated - open the document above for the full version.

Test Report

Shenzhen Toby Technology Co., Ltd. Report No.: TBR-C-202510-0082-31 Page: 1 of 36 TB-RF-074-1.0 1/F., Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China Tel: +86 75526509301 Fax: +86 75526509195 RF Test Report FCC ID: 2A4MW-MWE-CS3209 Report No. : TBR-C-202510-0082-31 Applicant : Marvel Technology(China) Co., Ltd Equipment Under Test (EUT) EUT Name : Touch Inquiry Machine Model No. : MWE-CS3209 Series Model No. : MWE-CS2209, MWE-CS5509, MWE-CS6509 Brand Name : MWE Sample ID : HC-C-202510-0082-01-01-1#&HC-C-202510-0082-01-01-2# Receipt Date : 2025-10-24 Test Date : 2025-10-24 to 2025-11-27 Issue Date : 2025-11-27 Standards : FCC Part 15 Subpart C 15.247 Test Method : ANSI C63.10:2020+Cor.1:2023 KDB 558074 D01 15.247 Meas Guidance v05r02 Conclusions : PASS In the configuration tested, the EUT complied with the standards specified above. Tested By : Gold. zhang Reviewed By : Wade. Lv Approved By : Ivan Su This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in the report. Report No.: TBR-C-202510-0082-31 Page: 2 of 36 TB-RF-074-1.0 Contents CONTENTS ............................................................................................................................................. 2 1. GENERAL INFORMATION ABOUT EUT.............................................................................. 5 1.1 Client Information ................................................................................................................. 5 1.2 General Description of EUT (Equipment Under Test) ................................................... 5 1.3 Block Diagram Showing the Configuration of System Tested ...................................... 7 1.4 Description of Support Units .............................................................................................. 8 1.5 Description of Test Mode .................................................................................................... 8 1.6 Description of Test Software Setting ................................................................................ 9 1.7 Measurement Uncertainty ................................................................................................ 10 1.8 Test Facility ......................................................................................................................... 11 2. TEST SUMMARY ..................................................................................................................... 12 3. TEST SOFTWARE ................................................................................................................... 12 4. TEST EQUIPMENT AND TEST SITE ................................................................................... 13 5. CONDUCTED EMISSION ....................................................................................................... 15 5.1 Test Standard and Limit .................................................................................................... 15 5.2 Test Setup ........................................................................................................................... 15 5.3 Test Procedure ................................................................................................................... 15 5.4 Deviation From Test Standard ......................................................................................... 16 5.5 EUT Operating Mode ........................................................................................................ 16 5.6 Test Data ............................................................................................................................. 16 6. RADIATED AND CONDUCTED UNWANTED EMISSIONS ............................................ 17 6.1 Test Standard and Limit .................................................................................................... 17 6.2 Test Setup ........................................................................................................................... 19 6.3 Test Procedure ................................................................................................................... 20 6.4 Deviation From Test Standard ......................................................................................... 21 6.5 EUT Operating Mode ........................................................................................................ 21 6.6 Test Data ............................................................................................................................. 21 7. RESTRICTED BANDS AND BAND EDGE REQUIREMENT .......................................... 22 7.1 Test Standard and Limit .................................................................................................... 22 7.2 Test Setup ........................................................................................................................... 22 7.3 Test Procedure ................................................................................................................... 23 7.4 Deviation From Test Standard ......................................................................................... 24 Report No.: TBR-C-202510-0082-31 Page: 3 of 36 TB-RF-074-1.0 7.5 EUT Operating Mode ........................................................................................................ 24 7.6 Test Data ............................................................................................................................. 24 8. BANDWIDTH TEST ................................................................................................................. 25 8.1 Test Standard and Limit ...................…

Text truncated - open the document above for the full version.

Test Report

Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202510-0082-32 Page: 24 of 30 FCC ID: 2A4MW-MWE-CS3209 TB-RF-074-1.0 7.2 Test Graphs NTNV-11B-Ant1-2412 NTNV-11B-Ant1-2437 NTNV-11B-Ant1-2462 NTNV-11G-Ant1-2412 NTNV-11G-Ant1-2437 NTNV-11G-Ant1-2462 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202510-0082-32 Page: 25 of 30 FCC ID: 2A4MW-MWE-CS3209 TB-RF-074-1.0 NTNV-11N20SISO-Ant1-2412 NTNV-11N20SISO-Ant1-2437 NTNV-11N20SISO-Ant1-2462 NTNV-11N40SISO-Ant1-2422 NTNV-11N40SISO-Ant1-2437 NTNV-11N40SISO-Ant1-2452 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202510-0082-32 Page: 26 of 30 FCC ID: 2A4MW-MWE-CS3209 TB-RF-074-1.0 8: Emissions in Restricted Bands 8.1 Test Result TestMode Ant. ChName Freq. [MHz] Detector Freq [MHz] Result [dBm] Limit [dBm] Result [dBuV/m] Limit [dBuV/m] Verdict 11B Ant1 Low 2412 Peak 2390.000 -35.52 ≤-21.20 59.68 ≤74 PASS 11B Ant1 Low 2412 Peak 2310.000 -36.97 ≤-21.20 58.23 ≤74 PASS 11B Ant1 Low 2412 Peak 2340.696 -32.63 ≤-21.20 62.57 ≤74 PASS 11B Ant1 Low 2412 AV 2390.000 -62.92 ≤-41.20 32.28 ≤54 PASS 11B Ant1 Low 2412 AV 2310.000 -63.96 ≤-41.20 31.24 ≤54 PASS 11B Ant1 Low 2412 AV 2346.159 -60.74 ≤-41.20 34.46 ≤54 PASS 11B Ant1 High 2462 Peak 2483.500 -35.53 ≤-21.20 59.67 ≤74 PASS 11B Ant1 High 2462 Peak 2500.000 -36.13 ≤-21.20 59.07 ≤74 PASS 11B Ant1 High 2462 Peak 2487.986 -33.09 ≤-21.20 62.11 ≤74 PASS 11B Ant1 High 2462 AV 2483.500 -57.03 ≤-41.20 38.17 ≤54 PASS 11B Ant1 High 2462 AV 2500.000 -63.28 ≤-41.20 31.92 ≤54 PASS 11B Ant1 High 2462 AV 2484.000 -56.7 ≤-41.20 38.50 ≤54 PASS 11G Ant1 Low 2412 Peak 2390.000 -38.48 ≤-21.20 56.72 ≤74 PASS 11G Ant1 Low 2412 Peak 2310.000 -35.55 ≤-21.20 59.65 ≤74 PASS 11G Ant1 Low 2412 Peak 2320.725 -32.06 ≤-21.20 63.14 ≤74 PASS 11G Ant1 Low 2412 AV 2390.000 -60.69 ≤-41.20 34.51 ≤54 PASS 11G Ant1 Low 2412 AV 2310.000 -62.76 ≤-41.20 32.44 ≤54 PASS 11G Ant1 Low 2412 AV 2340.507 -60.48 ≤-41.20 34.72 ≤54 PASS 11G Ant1 High 2462 Peak 2483.500 -34.72 ≤-21.20 60.48 ≤74 PASS 11G Ant1 High 2462 Peak 2500.000 -36.44 ≤-21.20 58.76 ≤74 PASS 11G Ant1 High 2462 Peak 2499.304 -34.07 ≤-21.20 61.13 ≤74 PASS 11G Ant1 High 2462 AV 2483.500 -53.82 ≤-41.20 41.38 ≤54 PASS 11G Ant1 High 2462 AV 2500.000 -63.27 ≤-41.20 31.93 ≤54 PASS 11G Ant1 High 2462 AV 2483.522 -53.82 ≤-41.20 41.38 ≤54 PASS 11N20SISO Ant1 Low 2412 Peak 2390.000 -36.86 ≤-21.20 58.34 ≤74 PASS 11N20SISO Ant1 Low 2412 Peak 2310.000 -36.12 ≤-21.20 59.08 ≤74 PASS 11N20SISO Ant1 Low 2412 Peak 2342.203 -31.76 ≤-21.20 63.44 ≤74 PASS 11N20SISO Ant1 Low 2412 AV 2390.000 -59.58 ≤-41.20 35.62 ≤54 PASS 11N20SISO Ant1 Low 2412 AV 2310.000 -62.62 ≤-41.20 32.58 ≤54 PASS 11N20SISO Ant1 Low 2412 AV 2389.870 -59.77 ≤-41.20 35.43 ≤54 PASS 11N20SISO Ant1 High 2462 Peak 2483.500 -34.54 ≤-21.20 60.66 ≤74 PASS 11N20SISO Ant1 High 2462 Peak 2500.000 -36.58 ≤-21.20 58.62 ≤74 PASS 11N20SISO Ant1 High 2462 Peak 2488.623 -32.81 ≤-21.20 62.39 ≤74 PASS 11N20SISO Ant1 High 2462 AV 2483.500 -53.4 ≤-41.20 41.80 ≤54 PASS 11N20SISO Ant1 High 2462 AV 2500.000 -62.88 ≤-41.20 32.32 ≤54 PASS 11N20SISO Ant1 High 2462 AV 2483.522 -53.4 ≤-41.20 41.80 ≤54 PASS 11N40SISO Ant1 Low 2422 Peak 2390.000 -35.43 ≤-21.20 59.77 ≤74 PASS 11N40SISO Ant1 Low 2422 Peak 2310.000 -35.01 ≤-21.20 60.19 ≤74 PASS 11N40SISO Ant1 Low 2422 Peak 2338.261 -33.75 ≤-21.20 61.45 ≤74 PASS 11N40SISO Ant1 Low 2422 AV 2390.000 -51.11 ≤-41.20 44.09 ≤54 PASS Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202510-0082-32 Page: 27 of 30 FCC ID: 2A4MW-MWE-CS3209 TB-RF-074-1.0 11N40SISO Ant1 Low 2422 AV 2310.000 -63.11 ≤-41.20 32.09 ≤54 PASS 11N40SISO Ant1 Low 2422 AV 2389.783 -51.92 ≤-41.20 43.28 ≤54 PASS 11N40SISO Ant1 High 2452 Peak 2483.500 -34.05 ≤-21.20 61.15 ≤74 PASS 11N40SISO Ant1 High 2452 Peak 2500.000 -36.02 ≤-21.20 59.18 ≤74 PASS 11N40SISO Ant1 High 2452 Peak 2496.739 -33.56 ≤-21.20 61.64 ≤74 PASS 11N40SISO Ant1 High 2452 AV 2483.500 -47.35 ≤-41.20 47.85 ≤54 PASS 11N40SISO Ant1 High 2452 AV 2500.000 -63.29 ≤-41.20 31.91 ≤54 PASS 11N40SISO Ant1 High 2452 AV 2483.514 -47.35 ≤-41.20 47.85 ≤54 PASS Note: 1. The Antenna Gain is compensated in the graph. 2. The limit in dBm for average detector is conversion from 54dBuV/m, according to 15.209(a), The limit in dBm for peak detector is 20dB above the limit of average detector in dBm. Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202510-0082-32 Page: 28 of 30 FCC ID: 2A4MW-MWE-CS3209 TB-RF-074-1.0 8.2 Test Graphs 11B-Ant1-2412-PASS 11B-Ant1-2412-PASS 11B-Ant1-2462-PASS 11B-Ant1-2462-PASS 11G-Ant1-2412-PASS 11G-Ant1-2412-PASS Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202510-0082-32 Page: 29 of 30 FCC ID: 2A4MW-MWE-CS3209 TB-RF-074-1.0 11G-Ant1-2462-PASS 11G-Ant1-2462-PASS 11N20SISO-Ant1-2412-PASS 11N20SISO-Ant1-2412-PASS 11N20SISO-Ant1-2462-PASS 11N20SISO-Ant1-2462-PASS Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202510-0082-32 Page: 30 of 30 FCC ID: 2A4MW-MWE-CS3209 TB-RF-074-1.0 11N40SISO-Ant1-2422-PASS 11N40SISO-Ant1-2422-PASS 11N40SISO-Ant1-2452-PASS 11N40SISO-Ant1-2452-PASS -----END OF THE REPORT-----

Test Report

Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202510-0082-32 Page: 1 of 30 FCC ID: 2A4MW-MWE-CS3209 TB-RF-074-1.0 RF Test Data for 2.4G Wi-Fi (Conducted Measurements) General Description of EUT EUT Name: Touch Inquiry Machine Model: MWE-CS3209 Sample ID: HC-C-202510-0082-01-01-2# Test Standard: FCC Part 15.247 Environmental Conditions Ambient Temperature: 25°C Ambient Humidity: 45%RH Test Power Supply: AC 120V/60Hz Test Engineer: Gold. zhang Note: For a more detailed features description, please refer to the report TBR-C-202510-0082-32 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202510-0082-32 Page: 2 of 30 FCC ID: 2A4MW-MWE-CS3209 TB-RF-074-1.0 Contents 1: DTS Bandwidth ............................................................................................................................................... 3 1.1Test Result .......................................................................................................................................... 3 1.2 Test Graphs ....................................................................................................................................... 4 2: Occupied Channel Bandwidth ........................................................................................................................ 6 2.1 Test Result ......................................................................................................................................... 6 2.2 Test Graphs ....................................................................................................................................... 7 3: Maximum conducted output power .............................................................................................................. 9 3.1 Test Result Average .......................................................................................................................... 9 4: Maximum power spectral density ............................................................................................................... 10 4.1 Test Result ....................................................................................................................................... 10 4.2 Test Graphs ..................................................................................................................................... 11 5: Band edge measurements ........................................................................................................................... 13 5.1 Test Result ....................................................................................................................................... 13 5.2 Test Graphs ..................................................................................................................................... 14 6: Conducted Spurious Emission ...................................................................................................................... 16 6.1 Test Result ....................................................................................................................................... 16 6.2 Test Graphs ..................................................................................................................................... 17 7: Duty Cycle .................................................................................................................................................... 23 7.1 Test Result ....................................................................................................................................... 23 7.2 Test Graphs ..................................................................................................................................... 24 8: Emissions in Restricted Bands ...................................................................................................................... 26 8.1 Test Result ....................................................................................................................................... 26 8.2 Test Graphs ..................................................................................................................................... 28 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202510-0082-32 Page: 3 of 30 FCC ID: 2A4MW-MWE-CS3209 TB-RF-074-1.0 1: DTS Bandwidth 1.1Test Result TestMode Ant. Frequency [MHz] DTS BW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 11B Ant1 2412 8.12 2408.04 2416.16 0.5 PASS 11B Ant1 2437 8.60 2433.04 2441.64 0.5 PASS 11B Ant1 2462 9.08 2457.56 2466.64 0.5 PASS 11G Ant1 2412 13.80 2405.76 2419.56 0.5 PASS 11G Ant1 2437 16.08 2429.16 2445.24 0.5 PASS 11G Ant1 2462 16.48 2453.88 2470.36 0.5 PASS 11N20SISO Ant1 2412 14.64 2405.76 2420.40 0.5 PASS 11N20SISO Ant1 2437 17.32 2428.52 2445.84 0.5 PASS 11N20SISO Ant1 2462 17.32 2453.56 2470.88 0.5 PASS 11N40SISO Ant1 2422 33.84 2406.56 2440.40 0.5 PASS 11N40SISO Ant1 2437 35.68 2419.24 2454.92 0.5 PASS 11N40SISO Ant1 2452 36.00 2434.08 2470.08 0.5 PASS Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, …

Text truncated - open the document above for the full version.

Contact Information

Applicant

Qing hu Zhou(Manager)
[email protected]Fax: 0755-28222764

Test Firm

Shenzhen Toby Technology Co., Ltd.Ray Lai
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz5.10 mW
215C2.41 GHz - 2.46 GHz31.80 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is conducted. This device supports 802.11b, 802.11g and 802.11n with a 20 MHz and 40 MHz bandwidth mode. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from Marvel Technology(China)Co.,Ltd

Floor Standing Advertizing Digital Signage - FCC ID 2A4MW-MWE813 - Marvel Technology(China)Co.,Ltd
2A4MW-MWE813

Floor Standing Advertizing Digital Signage

Dec 02, 2023

Equipment Class

DTS - Digital Transmission System
Ipad photo booth - FCC ID 2A4MW-MWEA55 - Marvel Technology(China)Co.,Ltd
2A4MW-MWEA55

Ipad photo booth

Jun 05, 2023

Equipment Class

DTS - Digital Transmission System