2A4N45126WWirless fire alarm control panel

YINGKOU TIANCHENG FIRE PROTECTION EQUIPMENT CO., LTD
Wirless fire alarm control panel - FCC ID 2A4N45126W - YINGKOU TIANCHENG FIRE PROTECTION EQUIPMENT CO., LTD
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
May 31, 2022
Application Purpose
Original Equipment
Date of Application
May 31, 2022
Equipment Note
Wirless fire alarm control panel
Frequency Range
470.00000000 - 470.00000000
Company
YINGKOU TIANCHENG FIRE PROTECTION EQUIPMENT CO., LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗
↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Pleasereadtheinstructionsbeforeinstallationanduse. JB-TB-TC5126W WirelessIntelligentFireAlarmControlPanel Installationinstructions Preface TheJB-TB-TC5126Wwirelessintelligentfirealarmcontrolpanelisanew generationofintelligentintegratedwirelessfirealarmcontrolpanel designedanddevelopedunderourcompany'sfullinvestigationofthefire protectionmarketdemand,summarizingthecompany'sfireengineering experienceinthefireprotectionindustryformanyyears,andfullymeeting therequirementsofGB4717-2005firealarmcontrolpanel,GA1151-2014 GeneralRequirementsforWirelessCommunicationFunctionofFireAlarm SystemandGB16806-2006FirelinkageControlSystem. Thecontrolpaneladoptswall-mountedstructureandmodulardesign,and hasthespecificationsoffullfunction,highreliabilityandflexible configuration.ThesystemadoptscolorLCDdisplay,whichiseasyto operate,easytolearnanduse.Thiscontrolpanelcanbeconnectedwith alarmpointsbywirelessway.JB-TB-TC5126Wwirelessintelligentfire alarmcontrolpanelcanbematchedwithpoint-typewirelessheatdetectors, wirelesssmEnteredetectors,MCP,wirelesscombustiblegasdetectors,etc. producedbyourcompanyasrequiredtomeetvariousneedsoffire engineering.Pleasereadthismanualcarefullybeforeusingandoperating thiscontrolpanel.Aftercommissioningandacceptance,thismanualshould betakencareofbyaspecialpersonandproperlykeptforfuturereference! 1.General Chapter1JB-TB-TC5126WWirelessIntelligentFireAlarmControlPanel Introduction 1.1Systemintroduction JB-TB-TC5126WWirelessIntelligentFireAlarmControlPanel(hereinafterreferred toascontrolpanel)isanewgenerationofwirelessfirealarmcontrolpanelintroduced byYingkouTianchengFireProtectionEquipmentCo.,Ltd.,whichcanbeused togetherwithotherrelatedproductsofourcompany.Thecontrolpanelissmallinsize, convenienttoinstallandsimpletooperate,andiswidelyusedinfireprotection engineering.Thefirealarmcontrolsystemcanbewidelyusedinsmall-scalefire protectionprojectssuchashigh-gradeofficebuildings,residentialquarters, departmentstores,gymnasiums,libraries,supermarkets,hotels,etc. Note:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClass Bdigitaldevice,pursuanttopart15oftheFCCrules.Theselimitsaredesignedto providereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation. Thisequipmentgenerates,usesandcanradiateradiofrequencyenergyand,ifnot installedandusedinaccordancewiththeinstructions,maycauseharmfulinterference toradiocommunications. However,thereisnoguaranteethatinterferencewillnotoccurinaparticular installation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevision reception,whichcanbedeterminedbyturningtheequipmentoffandon,theuseris encouragedtotrytocorrecttheinterferencebyoneormoreofthefollowing measures: --Reorientorrelocatethereceivingantenna. --Increasetheseparationbetweentheequipmentandreceiver. --Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthe receiverisconnected. --Consultthedealeroranexperiencedradio/TVtechnicianforhelp. Important:Youarecautionedthatchangesormodificationsnotexpresslyapprovedby thepartyresponsibleforcompliancecouldvoidtheuser'sauthoritytooperatethe equipment. Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothe followingtwoconditions:(1)Thisdevicemaynotcauseharmfulinterference,and(2) thisdevicemustacceptanyinterferencereceived,includinginterferencethatmay causeundesiredoperation. AnyChangesormodificationsnotexpresslyapprovedbythepartyresponsiblefor compliancecouldvoidtheuser'sauthoritytooperatetheequipment. 1.2Systemspecifications Withthenewgenerationofhigh-speedprocessors,comparedwiththetraditional technology,thedataprocessingspeedisfasterandthedatastoragecapacityislarger. Thecontrolpanelisbeautifulinappearance,easytooperate,easytolearnanduse. LCDisadopted,withdisplayresolutionof480×272,andinformationdisplayis intuitive.Systemoperationhistoryrecordingfunction:firealarmhistory,linkage history,faulthistoryandotherhistoryeachhaveacapacityof1000.ItCANsupport CANbusandnetworkwithotherfirealarmcontrolpanelsofourcompany.Wireless 470MHZcommunicationmodeisadoptedtoconnectwiththedetectorsmatchedwith thesystem.Executivestandard:GB4717-2005firealarmcontrolpanelGA1151-2014 generalrequirementsforwirelesscommunicationfunctionoffirealarmsystem GB16806-2006firelinkagecontrolsystem 1.3Introductionofcontrolpanelcomponents Inordertomakeyoumorefamiliarwiththecontrolpanel,thefollowingbriefly introducesthemaincomponentsofthecontrolpanel: ·Maincontrolmodule Themaincontrolboardisresponsibleforanalyzingandprocessingtheinformation datatransmittedbyothercomponentsinthesystem,andaccordingtothedataanalysis results,commandingothercomponentsinthesystemtoexecutecorresponding commands,suchascontrolspeakervoicealarm,etc. ·Displaymodule Thedisplaycomponentprovidesthemainoutputinterfaceofalarminformation,as wellasthedailymaintenanceandqueryinterface. ·Keymodule Matrixbuttonsareusedinthecontrolpanel,whichisveryconvenientforuserstoset upandmaintainthesystem. ·Powermodule Thepowersupplymodulesuppliespowerforthewholesystemequipment,and providespowerfaultsignalssuchasmainpowerfault,standbypowerfaultand standbypowerundervoltage,andhasgoodanti-interferenceability. ·Wireless470module The470MHzFSKcodedbidirectionalcommunicationcancommunicatewith32 wirelessdevices. ·Loopcontrolpanel Thiscontrolpanelcanbeconnectedwith18intelligentloopcontrolpanels,whichhas lesswiringandhighreliability.Eachstart/stopkeyonthemanualfirecontrolstartup panelcanbeassociatedwithanybusequipmentconnectedtothesystembydefinition, andcompletethestart/stopcontrolofthebuslinkageequipment,thusthoroughly solvingtheinherentproblemsofengineeringwiring,equipmentconfigurationand installationanddebuggingofthealarmlinkageintegratedsystem. ·Directcontrolpanel Thiscontrolpanelcanbeequippedwith6-waythree-wiredirectcontrolpanel,and hasthefunctionsofdetectingopencircuitandshortcircuitofoutputline,whichcan guaranteethereliabilityofthecontrolmoduleitselfanditsconnectionwithimportant equipmenttothemaximumextent. 1.4Maintechnicalspecifications 1.4.1powersupply Mainpowersupply:AC220V(3.5A)voltagerange+10%~-15%.…

Text truncated - open the document above for the full version.

Attestation Statements

YINGKOU TIANCHENG FIRE PROTECTION EQUIPMENT CO., LTD Date: 2022-4- 26 To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD FCC ID: 2A4N45126W To Whom It May Concern: This letter is to ascertain that YINGKOU TIANCHENG FIRE PROTECTION EQUIPMENT CO., LTD EUT:Wirless fire alarm control panel MODEL No.: JB-TB-TC5126W Has been the units used for conducting FCC compliance testing, the SDoC part have be tested by EMTEK (SHENZHEN) CO., LTD. If you have any question or concerns, pls. contact us. Sincerely, Client’s signature : Client’s name / title :QUN JIAO/Sales director Contact information / address: YINGKOU TIANCHENG FIRE PROTECTION EQUIPMENT CO., LTD / NO11-2 KECHECHANG XILI, XISHI DISTRICT, PILOT FREE TRADE ZONE,

Cover Letter(s)

Rev 11/20/07 YINGKOU TIANCHENG FIRE PROTECTION EQUIPMENT CO., LTD Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: 2A4N45126W Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Block Diagram, Schematics, Operational Description, Block Diagram, Schematics, Operational Description, The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Client’s name / title :QUN JIAO/Sales director Contact information / address: YINGKOU TIANCHENG FIRE PROTECTION EQUIPMENT CO., LTD /NO11-2 KECHECHANG XILI, XISHI DISTRICT, PILOT FREE TRADE ZONE,

Cover Letter(s)

YINGKOU TIANCHENG FIRE PROTECTION EQUIPMENT CO., LTD Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Date: 2022-4-26 SUBJECT: FCC Application for FCC ID: 2A4N45126W To Whom It May Concern: We, the undersigned, hereby authorize Lisa Wangat EMTEK (SHENZHEN) CO., LTD.on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by EMTEK (SHENZHEN) CO., LTD.on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti- Drug Abuse Act. We, the applicant, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Regards, Client’s name / title :QUN JIAO/Sales director Contact information / address: YINGKOU TIANCHENG FIRE PROTECTION EQUIPMENT CO., LTD /NO11-2 KECHECHANG XILI, XISHI DISTRICT, PILOT FREE TRADE ZONE,

External Photos

EUT View 1 Sucker Antenna

Internal Photos

Module

Test Report

Customer/ ProjectName RAK-470Msucker antenna freque ncy range 470-510MHz P/NV1799-020-A-01 editio n A radio frequency LY affir m charac ter XY affir m structureJWA PM MD date 2019.8.27 Customer confirmatio n RFartisan □satisfied □bebasically satisfied □discontent Structural technician □satisfied□bebasically satisfied □discontent ProjectManagement(PM Manager) □satisfied□bebasically satisfied □discontent Recommendationdescription: FormNo.:HD-QR-EN-002Version:A0SavePeriod:5yearsEffectiveDate:2020-1-41 (Content) 1.CoverCover(Cover)..........................................................................1 2.Catalogue(Content)...........................................................................2 3.Productsurface(ProductPicture).......................................................3 4.ProductSpecificationDescription(Productspeciticationdescribes)4 5.ElectricalTestReport(RadiationReport).......................................5 FormNo.:HD-QR-EN-002Version:A0SavePeriod:5yearsEffectiveDate:2020-1-42 FormNo.:HD-QR-EN-002Version:A0SavePeriod:5yearsEffectiveDate:2020-1-43 4.ProductSpecificationDescription(Productspeciticationdescribes) Electricalparameters(Parameter) FrequencyRange(Frequency) 470-510MHz Inputimpedance(Impedance) 50Ω ResidentBobby(VSWR) ≤2.0 Gaingain(Gain) 5dBi Maximumefficiency(Max.Efficiency ) ≥20% Polarizationmode(Polarization) Linearpolarization/Vertical RadiationDirectionMap(Radiation pattern) Omni-directional InterfaceType(Connector) RP-SMA-J Mechanicalparameters(MechanicalParameter) Totallength(Length) 147±3.0mm Saltspraytest(SaltSprayTest) 48H Environmentalparameters(Environment Parameter) Operatingtemperature(Operation Temperature) -30°C~65°C Storagetemperature(Storage Temperature) -30°C~75°C FormNo.:HD-QR-EN-002Version:A0SavePeriod:5yearsEffectiveDate:2020-1-44 directionaldiagram FormNo.:HD-QR-EN-002Version:A0Period:5yearsEffectiveDate:2020-1-45

Test Report

Report No. ENS2201270046W00201R Page 1 of 27 Ver.1.0 TEST REPORT Product Name : Wirless fire alarm control panel Model Number : JB-TB-TC5126W FCC ID : 2A4N45126W Prepared for : YINGKOU TIANCHENG FIRE PROTECTION EQUIPMENT CO., LTD Address : NO11-2 KECHECHANG XILI, XISHI DISTRICT, PILOT FREE TRADE ZONE, YINGKOU CITY, CHINA Prepared by : EMTEK (SHENZHEN) CO., LTD. Address : Building 69, Majialong Industry Zone, Nanshan District, Shenzhen, Guangdong, China Tel: (0755) 26954280 Fax: (0755) 26954282 Report Number : ENS2201270046W00201R Date(s) of Tests : February 1, 2022 to March 11, 2022 Date of issue : March 11, 2022 Report No. ENS2201270046W00201R Page 2 of 27 Ver.1.0 TEST RESULT CERTIFICATION Applicant : YINGKOU TIANCHENG FIRE PROTECTION EQUIPMENT CO., LTD Address : NO11-2 KECHECHANG XILI, XISHI DISTRICT, PILOT FREE TRADE ZONE, YINGKOU CITY, CHINA Manufacturer : YINGKOU TIANCHENG FIRE PROTECTION EQUIPMENT CO., LTD Address : NO11-2 KECHECHANG XILI, XISHI DISTRICT, PILOT FREE TRADE ZONE, YINGKOU CITY, CHINA EUT : Wirless fire alarm control panel Model Name : JB-TB-TC5126W Trademark : Tiancheng Measurement Procedure Used: APPLICABLE STANDARDS STANDARD TEST RESULT FCC 47 CFR Part 2, Subpart J FCC 47 CFR Part 15, Subpart C PASS The above equipment was tested by SHENZHEN EMTEK CO., LTD. The test data, data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.10 (2013) and the energy emitted by the sample EUT tested as described in this report is in compliance with the requirements of FCC Rules Part 2 and Part 15.231 REQUIREMENTS. The test results of this report relate only to the tested sample identified in this report. Date of Test : February 1, 2022 to March 11, 2022 Prepared by : Luo peiye /Editor Reviewer : Joe Xia/Supervisor Approve & Authorized Signer : Lisa Wang/Manager Report No. ENS2201270046W00201R Page 3 of 27 Ver.1.0 Table of Contents 1 EUT TECHNICAL DESCRIPTION ................................................................................................................ 4 2 SUMMARY OF TEST RESULT .................................................................................................................... 5 3 TEST METHODOLOGY ................................................................................................................................ 6 3.1 GENERAL DESCRIPTION OF APPLIED STANDARDS ....................................................................... 6 3.2 MEASUREMENT EQUIPMENT USED .................................................................................................. 6 3.3 DESCRIPTION OF TEST MODES ........................................................................................................ 6 4 FACILITIES AND ACCREDITATIONS ......................................................................................................... 8 4.1 FACILITIES ............................................................................................................................................ 8 4.2 LABORATORY ACCREDITATIONS AND LISTINGS ............................................................................ 8 5 TEST SYSTEM UNCERTAINTY ................................................................................................................... 9 6 SETUP OF EQUIPMENT UNDER TEST .................................................................................................... 10 6.1 RADIO FREQUENCY TEST SETUP 1 ................................................................................................ 10 6.2 RADIO FREQUENCY TEST SETUP 2 ................................................................................................ 10 6.3 CONDUCTED EMISSION TEST SETUP ............................................................................................ 12 6.4 BLOCK DIAGRAM CONFIGURATION OF TEST SYSTEM ................................................................ 13 6.5 SUPPORT EQUIPMENT ...................................................................................................................... 13 7 TEST REQUIREMENTS.............................................................................................................................. 14 7.1 OCCUPIED BANDWIDTH .................................................................................................................... 14 7.2 FREQUENCY STABILITY .................................................................................................................... 16 7.3 RADIATED SPURIOUS EMISSION ..................................................................................................... 17 7.4 TRANSMISSION REQUIREMENT ...................................................................................................... 24 7.5 CONDUCTED EMISSION TEST ......................................................................................................... 26 7.6 Antenna Application ............................................................................................................................. 27 Report No. ENS2201270046W00201R Page 4 of 27 Ver.1.0 1 EUT TECHNICAL DESCRIPTION Characteristics Description Product: Wirless fire alarm control panel Model Number: JB-TB-TC5126W Modulation: FSK modulation Operating Frequency Range(s): 470MHz Number of Channels: 1 channel Max Transmit Power: 87.06dBuV/m@3m Antenna Type : Sucker Antenna Antenna Gain: 5 dBi Power supply: AC 120V/60Hz Date of Received: February 1, 2022 Note: for more details, please refer to the User’s manual of the EUT. Report No. ENS2201270046W00201R Page 5 of 27 Ver.1.0 2 SUMMARY OF TEST RESULT FCC Part Clause Test Parameter Verdict Remark 15.231(c) Occupied Bandwidth PASS 15.231(d) Frequency stability N/A 15.231(b) Radiated Spurious Emissions PASS 15.231(a) Transmission Requirement PASS 15.203 Antenna Requirement PASS 15.207(a) Conducted Emission PASS NOTE1: N/A (Not Applicable) RELAT…

Text truncated - open the document above for the full version.

Test Setup Photos

1.1. Photos of Radiation Emission Measurement Spurious Emission Test Setup (Below 1GHz) Spurious Emission Test Setup (Above 1GHz) ----------------The end----------------

Contact Information

Applicant

QUN JIAO(Sales director)
[email protected]0086-18841788877Fax: N/A

Test Firm

EMTEK (Shenzhen) Co., Ltd.Lisa Wang
[email protected]86 755 26954280

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231470 MHz - 470 MHz-
Confidentiality
Long Term