FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Jiangxi EQi Industrial Co., Ltd./
  3. 2A4NH-L2301

2A4NH-L2301Power Station

Jiangxi EQi Industrial Co., Ltd.
Power Station - FCC ID 2A4NH-L2301 - Jiangxi EQi Industrial Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 07, 2024
Application Purpose
Original Equipment
Date of Application
Apr 07, 2024
Equipment Note
Power Station
Frequency Range
2402.00000000 - 2480.00000000
Company
Jiangxi EQi Industrial Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

AC 120V 60Hz L2301 FCC Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: — Reorient or relocate the receiving antenna. — Increase the separation between the equipment and receiver. — Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. — Consult the dealer or an experienced radio/TV technician for help. Note: The Grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. such modifications could void the user's authority to operate the equipment. The device has been evaluated to meet general RF exposure requirement. To maintain compliance with FCC's RF exposure guidelines, the distance must be at least 20 cm between the radiator and your body, and fully supported by the operating and installation IC Warning This device complies with Industry Canada license-exempt RSS standard (s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le present appareil est conforme aux CNR d"industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisee aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2)l’utilisateur de l' appareil doit accepter tout brouillage radioelectrique subi, meme si le brouillage est susceptible d'en compromettre le fonctionnement. CAN ICES-003(B) / NMB-003(B) The device has been evaluated to meet general RF exposure requirement. To maintaincompliance withRSS-102-Radio Frequency (RF) Exposure guidelines, this equipment shouldbe installed and operated with a minimum distance of 20cm between the radiator and your body. le dispositif de a ete evalue a repondre general rf exposition exigence. pour maintenir laconformite avec les directives d'exposition du RSS-102-Radio Frequence (RF).ce materiel doitetre installe et exploite a une distance minimale de 20 cm entre le radiateur et votre corps.

External Photos

Appendix- L2301-Photos Model L2301 FCC ID: 2A4NH-L2301 Page 3 of 17 2. Photographs –Constructional Details 2.1. EUT – External View Appendix- L2301-Photos Model L2301 FCC ID: 2A4NH-L2301 Page 4 of 17 Appendix- L2301-Photos Model L2301 FCC ID: 2A4NH-L2301 Page 5 of 17 Appendix- L2301-Photos Model L2301 FCC ID: 2A4NH-L2301 Page 6 of 17

Internal Photos

Appendix- L2301-Photos Model L2301 FCC ID: 2A4NH-L2301 Page 7 of 17 2.2. EUT – Internal View Appendix- L2301-Photos Model L2301 FCC ID: 2A4NH-L2301 Page 8 of 17 Appendix- L2301-Photos Model L2301 FCC ID: 2A4NH-L2301 Page 9 of 17 Appendix- L2301-Photos Model L2301 FCC ID: 2A4NH-L2301 Page 10 of 17 Appendix- L2301-Photos Model L2301 FCC ID: 2A4NH-L2301 Page 11 of 17 Appendix- L2301-Photos Model L2301 FCC ID: 2A4NH-L2301 Page 12 of 17 Appendix- L2301-Photos Model L2301 FCC ID: 2A4NH-L2301 Page 13 of 17 Appendix- L2301-Photos Model L2301 FCC ID: 2A4NH-L2301 Page 14 of 17 Appendix- L2301-Photos Model L2301 FCC ID: 2A4NH-L2301 Page 15 of 17 BT Ant. BLE Ant. 433M RX Ant. Appendix- L2301-Photos Model L2301 FCC ID: 2A4NH-L2301 Page 16 of 17 Appendix- L2301-Photos Model L2301 FCC ID: 2A4NH-L2301 Page 17 of 17

RF Exposure Info

Waltek Testing Group Co., Ltd. http://www.waltek.com.cn Page 1 of 8 TEST REPORT Referen ce No. .................... : WTD24D02030231W004 FCC ID ................................ : 2A4NH-L2301 Applicant ............................ : Jiangxi EQi Industrial Co., Ltd Address .............................. : Luliang Road, Yining Town, Xiushui County, Jiujiang City, Jiangxi Province,China Manufacturer .................... : Jiangxi EQi Industrial Co., Ltd Address .............................. : Luliang Road, Yining Town, Xiushui County, Jiujiang City, Jiangxi Province,China Product ............................... : Power Station Model(s). ............................ : L2301 Standards........................... : FCC 47CFR Part 2 Subpart J Section 2.1091 Date of Receipt sample .... : 2024-02-26 Date of Test ....................... : 2024-02-26 to 2024-03-14 Date of Issue ...................... : 2024-03-29 Test Result ......................... : Pass Remarks: The re sults shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Testing Group Co., Ltd. Address: No. 77, Houjie Section, Guantai Road, Houjie Town, Dongguan City, Guangdong, China Tel: +86-769-2267 6998 Fax: +86-769-2267 6828 Compiled by: Approved by: Estel Qian / Project Engineer Deval Qin / Designated Reviewer Reference No.: WTD24D02030231W004 Page 2 of 8 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 2. Contents Page 1 COVER PAGE ........................................................................................................................................... 1 2. CONTENTS ............................................................................................................................................................ 2 3. REVISION HISTORY ............................................................................................................................................ 3 4. GENERAL INFORMATION .................................................................................................................................. 4 4.1. GENERAL DESCRIPTION OF E.U.T. ............................................................................................................ 4 4.2. DETAILS OF E.U.T. ..................................................................................................................................... 4 4.3. TEST FACILITY ............................................................................................................................................ 5 4.4. SUBCONTRACTED ....................................................................................................................................... 5 4.5. ABNORMALITIES FROM STANDARD CONDITIONS ....................................................................................... 5 5. TEST SUMMARY .................................................................................................................................................. 6 6. RF EXPOSURE ...................................................................................................................................................... 7 6.1. REQUIREMENTS .......................................................................................................................................... 7 6.2. THE PROCEDURES / LIMIT ........................................................................................................................... 7 6.3. MPE CALCULATION METHOD .................................................................................................................... 8 6.4. RADIO FREQUENCY RADIATION EXPOSURE EVALUATION ......................................................................... 8 Reference No.: WTD24D02030231W004 Page 3 of 8 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 3. Revision History Test Report No. Date of Receipt Sample Date of Test Date of Issue Purpose Comment Approved WTD24D02030231W004 2024-02-26 2024-02-26 to 2024-03-14 2024-03-29 Original - Valid Reference No.: WTD24D02030231W004 Page 4 of 8 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 4. General Information 4.1. General Description of E.U.T. Product: Power Station Model(s): L2301 Model Description: N/A BT Version: BT: V5.1 BLE: V4.2 Hardware Version: WR-FS-BT V1.3 Software Version: L2301 V1.0 4.2. Details of E.U.T. Operation Frequency: 2402-2480MHz Max. RF output power: Bluetooth: 2.46dBm BLE: 2.60dBm Modulation Technology: Bluetooth: GFSK, π/4DQPSK, 8DPSK BLE: GFSK Antenna installation: PCB Antenna Antenna Gain: 5.3dBi Note: #: The antenna gain is provided by the applicant, and the applicant should be responsible for its authenticity, WALTEK lab has not verified the authenticity of its information. Ratings: AC 120V, 60Hz Reference No.: WTD24D02030231W004 Page 5 of 8 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 4.3. Test Facility The test facility has a test site registered with the following organizations: ISED CAB identifier: CN0013. Test Firm Registration No.: 7760A. Waltek Testing Group Co., Ltd. Has been registered and fully described in a report filed with the Industry Canada. The acceptance letter from the Industry Canada is maintained in our files. Registration number 7760A, October 15, 2016. FCC Designation No.: CN1201. Test Firm Registration No.: 523476. Waltek Testing Group Co., Ltd. EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. Registration number 523476, September 10, 2019. 4.4. Subcontracted Whether parts of tests for the product have been subcontracted to other labs: Yes No If Yes, list the related test items and lab i…

Text truncated - open the document above for the full version.

Test Report

Waltek Testing Group Co., Ltd. http://www.waltek.com.cn Page 1 of 33 TEST REPORT Referen ce No. .................... : WTD24D02030231W002 FCC ID ................................ : 2A4NH-L2301 Applicant ............................ : Jiangxi EQi Industrial Co., Ltd Address .............................. : Luliang Road, Yining Town, Xiushui County, Jiujiang City, Jiangxi Province,China Manufacturer .................... : Jiangxi EQi Industrial Co., Ltd Address .............................. : Luliang Road, Yining Town, Xiushui County, Jiujiang City, Jiangxi Province,China Product ............................... : Power Station Model(s). ............................ : L2301 Standards........................... : FCC 47CFR Part 15.247 Date of Receipt sample .... : 2024-02-26 Date of Test ....................... : 2024-02-26 to 2024-03-14 Date of Issue ...................... : 2024-03-29 Test Result ......................... : Pass Remarks: The re sults shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Testing Group Co., Ltd. Address: No. 77, Houjie Section, Guantai Road, Houjie Town, Dongguan City, Guangdong, China Tel: +86-769-2267 6998 Fax: +86-769-2267 6828 Compiled by: Approved by: Estel Qian / Project Engineer Deval Qin / Designated Reviewer Reference No.: WTD24D02030231W002 Page 2 of 33 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 2 Contents Page 1 COVER PAGE ........................................................................................................................................... 1 2 CONTENTS ............................................................................................................................................... 2 3 REVISION HISTORY ................................................................................................................................. 4 4 GENERAL INFORMATION ....................................................................................................................... 5 4.1 General Description of E.U.T. ....................................................................................................... 5 4.2 Details of E.U.T. ............................................................................................................................ 5 4.3 Channel List .................................................................................................................................. 5 4.4 Test Facility ................................................................................................................................... 6 4.5 Subcontracted ............................................................................................................................... 6 4.6 Abnormalities from Standard Conditions ...................................................................................... 6 4.7 Test Mode ..................................................................................................................................... 6 5 TEST SUMMARY ...................................................................................................................................... 7 6 EQUIPMENT USED DURING TEST ......................................................................................................... 8 6.1 Equipments List ............................................................................................................................ 8 6.2 Description of Support Units ......................................................................................................... 9 6.3 Measurement Uncertainty ............................................................................................................ 9 6.4 Test Equipment Calibration .......................................................................................................... 9 7 DUTY CYCLE .......................................................................................................................................... 10 8 CONDUCTED EMISSION ....................................................................................................................... 11 8.1 E.U.T. Operation ......................................................................................................................... 11 8.2 EUT Setup .................................................................................................................................. 11 8.3 Measurement Description ........................................................................................................... 11 8.4 Conducted Emission Test Result ............................................................................................... 12 9 RADIATED EMISSIONS ......................................................................................................................... 14 9.1 EUT Operation ............................................................................................................................ 14 9.2 Test Setup .................................................................................................................................. 15 9.3 Spectrum Analyzer Setup ........................................................................................................... 16 9.4 Test Procedure ........................................................................................................................... 17 9.5 Corrected Amplitude & Margin Calculation ................................................................................ 17 9.6 Summary of Test Results ........................................................................................................... 18 10 CONDUCTED SPURIOUS EM…

Text truncated - open the document above for the full version.

Test Report

Application Note AN043 Small Size 2.4 GHz PCB antenna By Audun Andersen 1 KEYWORDS • CC25xx • CC24xx • CC2480 • PCB antenna • USB dongle • 2.4 GHz • Inverted F Antenna 2 INTRODUCTION The PCB antenna used on the CC2511 USB dongle reference design is described in this application note. Even if the antenna presented is for a USB dongle design it can be used in all 2.4 GHz designs, especially where small space is required for the antenna. This application note describes the antenna dimensions, the RF performance and considerations for complying with regulatory limits when using this design. The suggested antenna design requires no more than 15.2 x 5.7 mm of space and ensures a VSWR ratio of less than 2 across the 2.4 GHz ISM band when connected to a 50 ohm source. Figure 1: CC2511 USB Dongle SWRA117D Page 1 of 21 Application Note AN043 Table of Contents 1 KEYWORDS...................................................................................................................1 2 INTRODUCTION.............................................................................................................1 3 ABBREVIATIONS...........................................................................................................2 4 ANTENNA DESIGN........................................................................................................3 4.1 DESIGN GOALS..........................................................................................................3 4.2 SIMULATION...............................................................................................................3 4.3 LAYOUT AND IMPLEMENTATION...................................................................................4 5 TEST RESULTS.............................................................................................................5 5.1 REFLECTION..............................................................................................................5 5.2 RADIATION PATTERN..................................................................................................7 5.3 OUTPUT POWER......................................................................................................15 5.4 SPURIOUS EMISSION AND HARMONICS......................................................................17 6 CONCLUSION ..............................................................................................................20 7 GENERAL INFORMATION..........................................................................................21 7.1 DOCUMENT HISTORY................................................................................................21 3 ABBREVIATIONS CAD Computer Aided Design CC24xx CC2400, CC2420, CC2430 and CC2431 CC25xx CC2500, CC2510, CC2511, CC2550 and CC2520 CC2480 Z-Accel ZigBee Processor IFA Inverted F Antenna ISM Industrial, Scientific and Medical LOS Line Of Sight PCB Printed Circuit Board PER Packet Error Rate VSWR Voltage Standing Wave Ratio SWRA117D Page 2 of 21 Application Note AN043 4 ANTENNA DESIGN The PCB antenna on the CC2511 USB dongle reference design is a meandered Inverted F Antenna (IFA). The IFA was designed to match an impedance of 50 ohm at 2.45 GHz. Thus no additional matching components are necessary. 4.1 Design Goals The reflection at the feed point of the antenna determines how much of the applied power is delivered to the antenna. A reflection of less than -10 dB across the 2.4 GHz ISM band, when connected to a 50 ohm source, was a design goal. Reflection of less than -10 dB, or VSWR less than 2, ensures that more than 90% of the available power is delivered to the antenna. Bandwidth is in this document defined as the frequency band where more than 90% of the available power is delivered to the antenna. Another design goal was to fit the size of the PCB antenna on a USB dongle and to obtain good performance also when the dongle is connected to a computer. 4.2 Simulation IE3D from Zeland, which is an electromagnetic simulation tool, was used to design the antenna. The accuracy of the simulation is controlled by the mesh. An increase of the mesh increases the simulation time. Thus, for initial simulations mesh = 1 should be used. When a fairly good result is achieved a higher mesh should be used to obtain more accurate results. Comparison of simulation and measurement results shows that the measured reflection is between the result obtained with mesh = 5 and mesh = 1; see Figure 2 for details. Figure 2: Comparison of Simulation and Measurements Results SWRA117D Page 3 of 21 Application Note AN043 4.3 Layout and Implementation Small changes of the antenna dimensions may have large impact on the performance. Therefore it is strongly recommended to make an exact copy of the reference design to achieve optimum performance. The easiest way to implement the antenna is to import the gerber or DXF file showing the antenna layout. These files are named IFA_USB.spl and IFA_USB.dxf respectively and are included in the CC2511 USB dongle reference design available from http://www.ti.com\lpw. The imported file can be used as a template when drawing the antenna. By using this procedure it should be possible to make an exact copy. If the PCB CAD tool being used does not support import of DXF or gerber files, Figure 3 and Table 1 should be used to ensure correct implementation. It is recommended to generate a gerber file for comparison with IFA_USB.spl when making a manual implementation. Most gerber viewers have the possibility to import several gerber files at the same time. Thus by placing the gerber file, showing the manually implemented antenna, on top of IFA_USB.spl it is easy to verify that the antenna is correctly implemented. It is also recommended to use the same thickness and type of PCB material as used in the reference design. Information about the PCB can be found in a separate readme file included in the reference design. To compensate for a thicker/thinner P…

Text truncated - open the document above for the full version.

Test Report

Waltek Testing Group Co., Ltd. http://www.waltek.com.cnPage 1 of 15 TEST REPORT Reference No. .................... : WTD24D02030231W001 Applicant ............................ : Jiangxi EQi Industrial Co., Ltd Address .............................. : Luliang Road, Yining Town, Xiushui County, Jiujiang City, Jiangxi Province,China Manufacturer .................... : Jiangxi EQi Industrial Co., Ltd Address ............................. : Luliang Road, Yining Town, Xiushui County, Jiujiang City, Jiangxi Province,China Product............................... : Power Station Model(s). ............................ : L2301 Standards .......................... : FCC Part 15 Subpart B:2021 Date of Receipt sample .... : 2024-02-26 Date of Test ....................... : 2024-02-26 to 2024-03-14 Date of Issue ...................... : 2024-03-29 Test Result ......................... : Pass Remarks: The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company.The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Testing Group Co., Ltd. Address: No. 77, Houjie Section, Guantai Road, Houjie Town, Dongguan City, Guangdong, China Tel: +86-769-2267 6998 Fax: +86-769-2267 6828 Compiled by: Approved by: Estel Qian / Project Engineer Deval Qin / Designated Reviewer Reference No.: WTD24D02030231W001 Page 2 of 15 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 1 Contents Page COVER PAGE ················································································································· 1 1 CONTENTS ............................................................................................................................................... 2 2 REVISION HISTORY ................................................................................................................................ 3 3 GENERAL INFORMATION ....................................................................................................................... 4 3.1 GENERAL DESCRIPTION OF E.U.T. ................................................................................................... 4 3.2 DETAILS OF E.U.T. ......................................................................................................................... 4 3.3 SUBCONTRACTED ........................................................................................................................... 4 3.4 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................ 4 4 TEST SUMMARY ...................................................................................................................................... 5 5 EQUIPMENT USED DURING TEST ......................................................................................................... 6 5.1 EQUIPMENT LIST ............................................................................................................................. 6 5.2 DESCRIPTION OF SUPPORT UNITS .................................................................................................... 6 5.3 MEASUREMENT UNCERTAINTY ......................................................................................................... 6 5.4 TEST MODE .................................................................................................................................... 7 6 EMISSION TEST RESULTS ..................................................................................................................... 8 6.1 AC POWER LINE CONDUCTED EMISSION, 150KHZ TO 30MHZ ........................................................... 8 6.2 RADIATION EMISSION, 30MHZ TO 1000MHZ .................................................................................. 11 7 PHOTOGRAPHS – TEST SETUP .......................................................................................................... 14 7.1 PHOTOGRAPH –AC POWER LINE CONDUCTED EMISSION TEST SETUP ............................................ 14 7.2 PHOTOGRAPH – RADIATED EMISSION TEST SETUP FOR 30MHZ-1000MHZ ..................................... 14 8 PHOTOGRAPHS – CONSTRUCTIONAL DETAILS .............................................................................. 15 Reference No.: WTD24D02030231W001 Page 3 of 15 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 2 Revision History Test Report No. Date of Receipt sample Date of Test Date of Issue Purpose CommentApproved WTD24D02030231W001 2024-02-26 2024-02-26 to 2024-03-14 2024-03-29Original - Valid Reference No.: WTD24D02030231W001 Page 4 of 15 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 3 General Information 3.1 General Description of E.U.T. Product ..................................... : Power Station Model(s) .................................... : L2301 Model Description ..................... : N/A Remark ..................................... : N/A 3.2 Details of E.U.T. Technical data .......................... : AC 120V, 60Hz 3.3 Subcontracted Whether parts of tests for the product have been subcontracted to other labs: Yes No If Yes, list the related test items and lab information: Test Lab: N/A Lab address: N/A Test items: N/A 3.4 Abnormalities from Standard Conditions None. Reference No.: WTD24D02030231W001 Page 5 of 15 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 4 Test Summary Test Item Test Requirement Test Result AC Power Line Conducted Emission (150kHz to 30MHz) FCC Part 15 Subpart B Pass Disturbance voltage at the antenna terminals (30MHz to 2150MHz) FCC Part 15 Subpart B N/A Radiated Emission (30MHz to 1GHz) FCC Part 15 Subpart B Pass Radiated Emission (Above 1GHz) FCC Part 15 Subpart B N/A Remark: Pass Test item meets the requirement Fail Test item does not meet the requirement N/A Test case does not apply to the test ob…

Text truncated - open the document above for the full version.

Test Setup Photos

Appendix- L2301-Photos Model L2301 FCC ID: 2A4NH-L2301 Page 1 of 17 1. Test Setup photos 1.1 Photograph – Conducted Emission Test Setup For Conducted Emission Test Site 1# 1.2 Photograph – Radiated Emissions For 9kHz-30MHz Test Site 2# Appendix- L2301-Photos Model L2301 FCC ID: 2A4NH-L2301 Page 2 of 17 For 30MHz-1000MHz Test Site 2# For Above 1GHz Test Site 1#

Contact Information

Applicant

zhou wei(director)
[email protected]0792-7990988Fax: 0792-7990988

Test Firm

WALTEK TESTING GROUP CO., LTD.Joy Zhou
[email protected]0769-22676998

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.82 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted.

Other Applications from Jiangxi EQi Industrial Co., Ltd.

Remote control - FCC ID 2A4NH-AS21 - Jiangxi EQi Industrial Co., Ltd.
2A4NH-AS21

Remote control

Aug 21, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Remote control - FCC ID 2A4NH-AS10 - Jiangxi EQi Industrial Co., Ltd.
2A4NH-AS10

Remote control

Aug 21, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Household electric treadmill - FCC ID 2A4NH-A013 - Jiangxi EQi Industrial Co., Ltd.
2A4NH-A013

Household electric treadmill

Jan 26, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
2A4NH-A012

Household electric treadmill

Nov 22, 2025

Equipment Class

DTS - Digital Transmission System
Fitness Walker - FCC ID 2A4NH-A008 - Jiangxi EQi Industrial Co., Ltd.
2A4NH-A008

Fitness Walker

Sep 15, 2024

Equipment Class

DTS - Digital Transmission System