This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ‐‐Reorient or relocate the receiving antenna. ‐‐Increase the separation between the equipment and receiver. ‐‐Connect the equipment into an outlet on a circuit different fromthat to which the receiver is connected. ‐‐Consult the dealer or an experienced radio/TV technician for help.ct. This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimumdistance of 20cmbetween the radiator and any part of your body.
JiangxiEQiIndustrialCo.,Ltd CERTIFICATIONSCONCERNING“COVERED”EQUIPMENT Date:Dec.28,2023 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,Maryland21046 FCCID:2A4NH-S32 ToWhomItMayConcern: Asrequiredbysection 2.911(d)(5)(i),JiangxiEQiIndustrialCo.,Ltd (“theapplicant”) certifiesthattheequipmentforwhichauthorizationissoughtisnot“covered” equipmentprohibitedfromreceivinganequipmentauthorizationpursuanttosection 2.903oftheFCCrules. Asrequiredbysection2.911(d)(5)(ii), JiangxiEQiIndustrialCo.,Ltd (“theapplicant”) certifiesthat,asofthedateofthefilingoftheapplication,theapplicantisnot identifiedontheCoveredListasanentityproducing“covered”equipment. Thankyouforyourattentiontothismatter. Sincerelyyours, Signature: PrintedName:zhouWei Company:JiangxiEQiIndustrialCo.,Ltd JobTitle:Director Email:[email protected] Telephone:0792-7990988
JiangxiEQiIndustrialCo.,Ltd ProductSimilarityDeclaration Date:2023-12-28 FCCID:2A4NH-S32 Subject:authorizationforaddingfamilymodels TowhomitMayconcern,Statement WewouldliketoconfirmtheproductHouseholdelectrictreadmillwithmodels(T4088,T4076, T4079,T4089,T3802,T3812,T3827A,T3837,T3839,T3840,T3841,T4051,T4052,T4253,T4254, GT5,GT7,LS2,LS6,LS8,LS10,URTM030.)aresameinallrespects.Onlythemodelnamesare differentfordifferentmarket requirement Yourssincerely, Signature PrintedName:zhouWei Company:JiangxiEQiIndustrialCo.,Ltd JobTitle:Director Email:[email protected] Telephone:0792-7990988
JiangxiEQiIndustrialCo.,Ltd RequestforConfidentialityLetter-FCC Date:Dec.28,2023 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,Maryland21046 Re:Requestforconfidentiality FCCID:2A4NH-S32 Towhomitmayconcern, Weherebyrespectfullyrequestthatundertheprovisionof47CFR0.459and0.457(d)the documentslistedbelowandattachedwiththisapplicationforcertificationbeprovidedwith confidentialstatus. Schematics.pdf OperationalDescription.pdf FrequencyBlockDiagrams.pdf Anyexhibit/informationforwhichwehaverequestedconfidentiality,butwhichmaynotbe accordedsuchtreatmentbytheFCC,shouldbereturnedtous. Thedocumentslistedabovecontaintradesecretsthataretreatedasconfidentialbyus. Substantialcompetitiveharmtouscouldresultshouldtheybemadeavailabletothepublic. Sincerely, Signature: PrintedName:zhouWei Company:JiangxiEQiIndustrialCo.,Ltd JobTitle:Director Email:[email protected] Telephone:0792-7990988
ExternalPhotos
FCCID:2A4NH-S32 Thisdevicecomplieswithpart15oftheFCCRules.Operationissubject tothefollowingtwoconditions: (1)thisdevicemaynotcauseharmfulinterference,and(2)Thisdevice mustacceptanyinterferencereceived,includinginterferencethatmay causeundesiredoperation.
InternalPhotos BLEANT ※※※※※ENDOFREPORT※※※※※
FCCID:2A4NH-S32 RFExposureEvaluation Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactofhumanexposure toradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE) Frequencyrange (MHz) Electricfield strength (V/m) Magneticfieldstrength (A/m) Powerdensity (mW/cm 2 ) Averagingtime (minutes) (A)LimitsforOccupational/ControlledExposures 0.3–3.06141.63*(100)6 3.0–301842/f4.89/f*(900/f 2 )6 30–30061.40.1631.06 300–1500f/3006 1500–100,00056 (B)LimitsforGeneralPopulation/UncontrolledExposure 0.3–1.346141.63*(100)30 1.34–30824/f2.19/f*(180/f 2 )30 30–30027.50.0730.230 300–1500f/150030 1500–100,0001.030 f=frequencyinMHz Friistransmissionformula:Pd=(Pout*G)/(4*pi*r 2 ) Where Pd=powerdensityinmW/cm 2 ,Pout=outputpowertoantennainmW; G=gainofantennainlinearscale,Pi=3.1416; R=distancebetweenobservationpointandcenteroftheradiatorincm PdidthelimitofMPE,1mW/cm 2 .Ifweknowthemaximumgainoftheantennaandthetotalpowerinputto theantenna,throughthecalculation,wewillknowthedistancerwheretheMPElimitisreached. TestProcedure SoftwareprovidedbyclientenabledtheEUTtotransmitandreceivedataatlowest,middleandhighest channelindividually. TestResultofRFExposureEvaluation BLEmode Channel Antenna Gain Antenna Gain (numeric) PeakOutput Power(dBm) PeakOutput Power(mW) PowerDensity (mW/cm2) Limitof Power Density (mW/cm2) Result 2480MHz-0.680.8550.531.130.0001921 PASS Remark:antennagain=-0.68dBi
dBi 2450MHz 2450MHz Jiangxi EQi Industrial Co., Ltd 4.0
BSLTestingCo.,LTD.ProjectNo.:BSL2305318275069F Page 1 of 41 FCCPART15C MeasurementandTestReport For JiangxiEQiIndustrialCo.,Ltd FCCID:2A4NH-S32 FCCRule(s)/Methods: FCCCFRTitle47Part15SubpartCSection15.247 ANSIC63.10:2013 ProductDescription: Householdelectrictreadmill Trademark Urevo,Superfit,costway,EQi Model/Typereference.: T4088,T4076,T4079,T4089,T3802,T3812, T3827A,T3837,T3839,T3840,T3841,T4051, T4052,T4253,T4254,GT5,GT7,LS2,LS6, LS8,LS10,URTM030. ReportNo.:BSL2305318275069F Dateofreceiptoftestitem:Nov.29,2023 Dateofsampling:Nov.29,2023 TestedDate:Nov.29,2023toDec.07,2023 IssuedDate:Dec.07,2023 TestedBy: LrisYao/Engineer ReviewedBy: LeviXiao/EMCManager Approved&AuthorizedBy: SalonOuyang/PSQManager BSLTestingCo.,LTD. 1/F,BuildingB,XinshidaiGRPark,ShiyanStreet,Bao'anDistrict,Shenzhen,Shiyan Street,Bao'anDistrict,Shenzhen,Guangdong,518052,People’sRepublicofChina Tel:400-882-9628Fax:86-755-26508703 BSLTestingCo.,LTD.ProjectNo.:BSL2305318275069F Page 2 of 41 TableofContents Page 1.VERSION4 2.SUMMARYOFTESTRESULTS5 2.1TESTFACILITY6 2.2MEASUREMENTUNCERTAINTY6 3.GENERALINFORMATION7 3.1GENERALDESCRIPTION7 3.2DESCRIPTIONOFTESTMODES9 3.3BLOCKDIGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED9 3.4DESCRIPTIONOFSUPPORTUNITS(CONDUCTEDMODE)9 3.5EQUIPMENTSLISTFORALLTESTITEMS10 4.EMCEMISSIONTEST12 4.1CONDUCTEDEMISSIONMEASUREMENT12 4.1.11POWERLINECONDUCTEDEMISSIONLIMITS12 4.1.2TESTPROCEDURE12 4.1.3DEVIATIONFROMTESTSTANDARD12 4.1.4TESTSETUP13 4.1.5EUTOPERATINGCONDITIONS13 4.1.6TESTRESULTS13 4.2RADIATEDEMISSIONMEASUREMENT13 4.2.1RADIATEDEMISSIONLIMITS16 4.2.2TESTPROCEDURE17 4.2.3DEVIATIONFROMTESTSTANDARD17 4.2.4TESTSETUP17 4.2.5EUTOPERATINGCONDITIONS18 5.RADIATEDBANDEMISSIONMEASUREMENT23 5.1TESTREQUIREMENT:23 5.2TESTPROCEDURE23 5.3DEVIATIONFROMTESTSTANDARD23 5.4TESTSETUP24 5.5EUTOPERATINGCONDITIONS24 5.6TESTRESULT25 6.POWERSPECTRALDENSITYTEST26 6.1APPLIEDPROCEDURES/LIMIT26 6.2TESTPROCEDURE26 6.3DEVIATIONFROMSTANDARD26 6.4TESTSETUP26 BSLTestingCo.,LTD.ProjectNo.:BSL2305318275069F Page 3 of 41 TableofContentsPage 6.5EUTOPERATIONCONDITIONS26 6.6TESTRESULTS27 7.CHANNELBANDWIDTH29 7.1APPLIEDPROCEDURES/LIMIT29 7.2TESTPROCEDURE29 7.3DEVIATIONFROMSTANDARD29 7.4TESTSETUP29 7.5EUTOPERATIONCONDITIONS29 7.6TESTRESULTS30 8.PEAKOUTPUTPOWERTEST32 8.1APPLIEDPROCEDURES/LIMIT32 8.2TESTPROCEDURE32 8.3DEVIATIONFROMSTANDARD32 8.4TESTSETUP32 8.5EUTOPERATIONCONDITIONS32 8.6TESTRESULTS33 9.CONDUCTEDBANDEDGEANDSPURIOUSEMISSION34 9.1APPLICABLESTANDARD34 9.2TESTPROCEDURE34 9.3DEVIATIONFROMSTANDARD34 9.4TESTSETUP34 9.5EUTOPERATIONCONDITIONS34 10.ANTENNAREQUIREMENT40 11.TESTSETUPPHOTO41 12.EUTCONSTRUCTIONALDETAILS41 BSLTestingCo.,LTD.ProjectNo.:BSL2305318275069F Page 4 of 41 1.VERSION ReportNo.VersionDescriptionApproved BSL2305318275069FRev.01InitialissueofreportDec.07,2023 BSLTestingCo.,LTD.ProjectNo.:BSL2305318275069F Page 5 of 41 2.SUMMARYOFTESTRESULTS Testproceduresaccordingtothetechnicalstandards: FCCPart15(15.247),SubpartC Standard Section TestItemJudgmentRemark FCCpart15.203/15.247 (c) AntennarequirementPASS FCCpart15.207ACPowerLineConductedEmissionPASS FCCpart15.247(b)(3)ConductedPeakOutputPowerPASS FCCpart15.247(a)(2)ChannelBandwidth&99%OCBPASS FCCpart15.247(e)PowerSpectralDensityPASS FCCpart15.247(d)BandEdgePASS FCCpart15.205/15.209SpuriousEmissionPASS NOTE: (1)“N/A”denotestestisnotapplicableinthisTestReport BSLTestingCo.,LTD.ProjectNo.:BSL2305318275069F Page 6 of 41 2.1TESTFACILITY BSLTESTINGCO.,LTD Add.:1/F,BuildingB,XinshidaiGRPark,ShiyanStreet,Bao'anDistrict,Shenzhen,ShiyanStreet, Bao'anDistrict,Shenzhen,Guangdong,518052,People’sRepublicofChina FCCTestFirmRegistrationNumber:562200 DesignationNumber:CN1338 ICRegisteredNo.:11093A DesignationNumber:CN0019 2.2MEASUREMENTUNCERTAINTY Thereporteduncertaintyofmeasurementy±U,whereexpendeduncertaintyUisbasedonastandard uncertaintymultipliedbyacoveragefactorofk=2,providingalevelofconfidenceofapproximately95 %。 No.ItemUncertainty 1 3mcamberRadiatedspurious emission(9KHz-30MHz) U=4.5dB 2 3mcamberRadiatedspurious emission(30MHz-1GHz) U=4.8dB 3 3mchamberRadiatedspurious emission(1GHz-6GHz) U=4.9dB 4 3mchamberRadiatedspurious emission(6GHz-40GHz) U=5.0dB 5ConducteddisturbanceU=3.2dB 6RFBandEdgeU=1.68dB 7RFpowerconductedU=1.86dB 8RFconductedSpuriousEmissionU=2.2dB 9RFOccupiedBandwidthU=1.8dB 10RFPowerSpectralDensityU=1.75dB 11humidityuncertaintyU=5.3% 12Temperatureuncertainty U=0.59°C BSLTestingCo.,LTD.ProjectNo.:BSL2305318275069F Page 7 of 41 3.GENERALINFORMATION 3.1GENERALDESCRIPTION Applicant: JiangxiEQiIndustrialCo.,Ltd Addressofapplicant: LuliangRoad,YiningTown,XiushuiCounty,JiujiangCity, JiangxiProvince,China Manufacturer: JiangxiEQiIndustrialCo.,Ltd Addressofmanufacturer: LuliangRoad,YiningTown,XiushuiCounty,JiujiangCity, JiangxiProvince,China ProductName: Householdelectrictreadmill ModelNo.: T4088,T4076,T4079,T4089,T3802,T3812,T3827A,T3837, T3839,T3840,T3841,T4051,T4052,T4253,T4254,GT5,GT7, LS2,LS6,LS8,LS10,URTM030. ModelDifferent.: Onlythemodelnamesaredifferent.(Maintestmodel:T4088) Hardwareversion V1.0 Softwareversion V1.0 SerialNo.: N/A Sample(s)Status:Engineersample OperationFrequency:2402MHz~2480MHz ChannelNumbers:40 ChannelSeparation:2MHz ModulationType:GFSK AntennaType: PCBAntenna Antennagain:-0.68dBi Powersupply: Input:AC100-120V,50/60Hz550W SWITCHINGPOWER ADAPTER: N/A BSLTestingCo.,LTD.ProjectNo.:BSL2305318275069F Page 8 of 41 OperationFrequencyeachofchannel ChannelFrequencyChannelFrequencyChannelFrequencyChannelFrequency 12402MHz112422MHz212442MHz312462MHz 22404MHz122424MHz222444MHz322464MHz 32406MHz132426MHz232446MHz332466MHz 42408MHz142428MHz242448MHz342468MHz 52410MHz152430MHz252450MHz352470MHz 62412MHz162432MHz262452MHz362472MHz 72414MHz172434MHz272454MHz372474MHz 82416MHz182436MHz282456MHz382476MHz 92418MHz192438MHz292458MHz392478MHz 102420MHz202440MHz302460MHz402480MHz Note: Insection15.31(m),regardstotheoperatingfrequencyrangeover10MHz,theLowestfrequency, themiddlefrequency,andthehighestfrequencyofchannelwereselectedtoperformthetest,and theselectedchannelseebelow: Chann…
Text truncated - open the document above for the full version.
EUTTESTPHOTO
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.10 mW |

Remote control
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Remote control
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Household electric treadmill
Equipment Class
DSC - Part 15 Security/Remote Control TransmitterHousehold electric treadmill
Equipment Class
DTS - Digital Transmission System
Fitness Walker
Equipment Class
DTS - Digital Transmission System