FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Green Energy Lighting Co., Ltd./
  3. 2A4SO-FLHL60

2A4SO-FLHL60LED Luminaires

Shenzhen Green Energy Lighting Co., Ltd.
LED Luminaires - FCC ID 2A4SO-FLHL60 - Shenzhen Green Energy Lighting Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 02, 2022
Application Purpose
Original Equipment
Date of Application
Mar 02, 2022
Equipment Note
LED Luminaires
Frequency Range
2412.00000000 - 2462.00000000
Company
Shenzhen Green Energy Lighting Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

RF Exposure Info

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Smart Light User Manual NO.1 Download and Install App Use your phone to scan the QR code below or search "Smart Life" in application market to download and install the App. If you don't have the account of Smart Life APP, register an account or sign in with cellphone number + verification code. Tap "Register" in the upper right 2.1.1 NO.2 Register/Login/Request Password Register 2.1 Please turn ON-OFF-ON-OFF-ON the lights make sure the device’ s instructor light quickly flashes, click "confirm light blinks rapidly" and go on to the next step. 3.1.2 NO.4 Control Device Lamp is of fLamp is on White Mode adjust brightness and temperature of white light Color Mode adjust color, brightness, saturation of colorful light Scene Mode selective modes, one tap to apply ON/OFF Switch timer pic2 pic1 3.1.3 The App interface will go through the changes during the network configuration process as shown in the picture 1. Picture 2 shows the interface when the device is connected successfully 3.1.4 Select the Wi-Fi, enter password and click "Confirm", as shown in the picture below. iPhone 8 Plus Hardware Specification Software Specification Connection: 2.4GHz Wi-Fi Light Appearance: 2700k - 6500K Soft White to Daylight Multicolor: Multiple Color Options(RGB) Dimmable (via app) Feature Be able to change the color by voice control. (No Hub required, Amanzon Alexa and google hoem or other assistant are sold separately). The dimming light can be adjusted from warm white light to white light and color temperature is from 2700K to 6500K. Multiple colors for your choices, adjust it to match your moods anytime. (adjust the color through smart phone APP). Be able to control the LED bulb anytime anywhere with the free APP in your tablet or smart phone (Android 9.0 or higher / IOS 10 or higher). 1. 2. 3. 4. Material: Aluminum+Glass cover Housing Color: Black Not suitable for standard in-wall dimmers. Be able to adjust light via the app only . The range of temperature circumstance is between -20 and +40, Humidity ≤ 95% RH. 6. Important Information Please read and follow all precautions of the smart LED bulb before installing or replacing it, including the following contents. Announcement W arning: not suitable for emergency lighting , having the risk of electric shock and burn. Don't put the product in a metal box because of its wireless function, which avoids the signal shield. Don't use the item under the abnormal circumstances such as chemistry, combustible gas, saturated salt fog and so on. The item should be installed in a place where is non-shaking, non-oscillating, non-wind and non-rain so that there are no gas and dust in the medium, which can not corrode metal, destroy the insulation and explode it. Please turn off the switch and wait the bulb to cool down before trying to replace it. Do not install the Smart Bulb when your hands are wet or 1. 2. 3. 4. 5. NO.3 Add Device Go to the App, on "Devices(Prepare)", tap "+" in the upper right of this page. to add device, as shown in the picture. 3.1.1 Add device 3.1 2. Penetrate the corresponding holes of the fitting through screws, set the gasket, screw the nuts, and then fix the light. 3. Connect the lights in a sequence as per the signal connecting sketch map and take the waterproof measures. 4. Get the power supply connected, and debug the programme. Adjust the angle of elevation as requested. 5.Fragile glass, handle with care, The non-artficial damage of gl ass,can be replaced Maintenances 1. In order to the life time of the product and more safe operation, please keep it clean, maintenance and pr eserve 2.While cleaning the lamp, please use the soft cloth with soap water and wring it, then try to sweep. 3. Don’t use the volatile chemic liquid such as alcoholic, gasoline or pesticide to sweep, otherwise, easily damage the lamp, thereby affect the life time of it. Notes: Do not dispose of electrical appliances as unsorted municipal waste, Use separate collection facilities. Contact you local vernment for Information regarding the collection systems available. If electrical appliances Are groundwater and get into food chain, damaging your health and well- - being. the go Cautions 1.Make sure that the product is installed Before plug in 2.Please notice that don’t use any objectives to cover the lamp. 3. Don’t use the lamp under sealed environment. 4. Maintenance should only be done by a professional technician. 5. 6. 7. 8. 9. In case of any change to the product we retain the right to inform you in advance Terminal block to be used shall conform to EN 609 98-2-1 or EN 60998-2-2; and shall be specified as following: - the type of terminal: screw/screwless; - number of terminals: 3 p oles; - rated voltage: Min. 240 V; - rated connecting capacity: Min. 1,0mm 2 ; - any necessary preparation of the ends of conductors: the le ngth of exposed ends of conductors shall not more than 8 mm;- any fixing method: fixed inside the connecting box. d Technology Parameter Technology Parameter Suitable for wet locations Installation Instruction(Only by an approve electrician) NO Parameter scope Item 2 Operating voltage 4 Beam angle 3 5 Operating humidity 6 Life time IP Rating 7 Weight Max projected area Mounting height Projection distance 8 9 10 11 12 Max power consumption LED Color 60W 1.43kg 120° RGB+++,Soft white to Daylight 10-90% IP66 >50000h 8-12m 9x10m 6m-8m AC120V-277V 50Hz/60Hz 1 Product I ntroduction Features & Applications Features & Applications This LED lighting fixture is consisted of high power LEDs , which is an environmental, energy-saving and the best solution of replacements for conventional Lightings. Various white colors configurations are available, such as cool white, warm white, natural white color. in i on i , hi (1) extended-aluminium housing, 4mm toughened glass, IP65. (2) As a decorative product, could be widely used for scu lptures, landmark buildings,stadiums, plazas, gardens, public parks and so on, especially used in virescence, the wall of , landsca…

Text truncated - open the document above for the full version.

External Photos

FCCID:2A4SO-FLHL60

ID Label/Location Info

LabelLocationOnEUT Label ProductName:LEDLuminaires ModelNo.:FLHL60 FCCID:2A4SO-FLHL60 ThisdevicecomplieswithPart15oftheFCCRules.Operationis subjecttothefollowingtwoconditions: (1)Thisdevicemaynotcauseharmfulinterference,and (2)Thisdevicemustacceptanyinterferencereceived,including interferencethatmaycauseundesiredoperation.

Internal Photos

FCCID:2A4SO-FLHL60 ANT

Operational Description

version01 ShenzhenGreenEnergyLightingCo.,Ltd. DeclarationconcerningAntennaSpecification Itisherebydeclaredthattheproduct ModelNo.:FLHL60,WPXW30,FLHX200,FLHX300,FLHX240,WPXW60,WPXW45, WPXW100,WPXW120,WPXW150,WPXW80,FLH40,FLHL80,FLHL100, FLHL150,CPXW100,CPXW120,FLHL40R,FLHL80R,FLHL100R,FLHL150R FCCID:2A4SO-FLHL60 fulfillstherequirementinFCCtestrelatingtotheantennatype. ThedevicespecifiedaboveconfirmstotheFCCrecommendationsfor internal antennatype(s) describedbelow: ModelNo.ofantenna:N/A Typeofantenna:FPCantenna Gainoftheantenna:2.07dBi Frequencyrange:2412-2462MHzfor802.11b/g/n(HT20) Themountingoftheantennaisfixedtotheradiomoduleandnootherantennashouldbeused. Companyname:ShenzhenGreenEnergyLightingCo.,Ltd. Address:1-5Floor,AArea,NO.303PolaoVillage,GuiyueRoad,PotouxiaCommunity, GuanlanStreet,LonghuaDist.,Shenzhen,China City:Shenzhen ZIP/Postalcode:518110 Country:China Place:Date:3/1/2022 Signature:

Test Report

Page1of37 AppendixTestData ReportNo.:18220WC20022501TestDate:2022.2.26 TestEngineer:Auditor: Temperature:24.3 °C RelativeHumidity:57% Pressure:1012hPa AppendixA:DTSBandwidth TestResult TestModeAntennaChannel DTSBW[MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict 11BAnt1 24129.6002406.9602416.560≥0.5PASS 24379.6002432.4402442.040≥0.5PASS 24629.1202457.9202467.040≥0.5PASS 11GAnt1 241214.9602404.0802419.040≥0.5PASS 243715.9602429.1202445.080≥0.5PASS 246215.5202454.4002469.920≥0.5PASS 11N20Ant1 241215.1602404.4002419.560≥0.5PASS 243715.1202429.4402444.560≥0.5PASS 246216.0802454.4402470.520≥0.5PASS Page2of37 TestGraphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 Page3of37 11G_Ant1_2412 11G_Ant1_2437 Page4of37 11G_Ant1_2462 11N20_Ant1_2412 11N20_Ant1_2437 Page5of37 11N20_Ant1_2462 Page6of37 AppendixB:OccupiedChannelBandwidth TestResult TestModeAntennaChannel OCB[MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict 11BAnt1 241212.5472405.6862418.233---PASS 243712.4522430.7932443.245---PASS 246212.4272455.8882468.315---PASS 11GAnt1 241216.9122403.5112420.423---PASS 243717.0342428.4742445.508---PASS 246217.0932453.5412470.634---PASS 11N20Ant1 241217.7142403.1322420.846---PASS 243717.8292428.0852445.914---PASS 246217.8652453.1562471.021---PASS Page7of37 TestGraphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 Page8of37 11G_Ant1_2412 11G_Ant1_2437 Page9of37 11G_Ant1_2462 11N20_Ant1_2412 11N20_Ant1_2437 Page10of37 11N20_Ant1_2462 Page11of37 AppendixC:Maximumconductedoutputpower TestResult TestModeAntennaChannelResult[dBm]Limit[dBm]Verdict 11BAnt1 241214.95≤30PASS 243712.87≤30PASS 246212.99≤30PASS 11GAnt1 241214.92≤30PASS 243715.13≤30PASS 246215.27≤30PASS 11N20Ant1 241215.20≤30PASS 243715.17≤30PASS 246215.32≤30PASS Page12of37 AppendixD:Maximumpowerspectraldensity TestResult TestModeAntennaChannelResult[dBm/3kHz]Limit[dBm/3kHz]Verdict 11BAnt1 2412-11.48≤8PASS 2437-12.11≤8PASS 2462-12.3≤8PASS 11GAnt1 2412-14.88≤8PASS 2437-16.75≤8PASS 2462-16.26≤8PASS 11N20Ant1 2412-16.08≤8PASS 2437-16.7≤8PASS 2462-16.29≤8PASS Page13of37 TestGraphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 Page14of37 11G_Ant1_2412 11G_Ant1_2437 Page15of37 11G_Ant1_2462 11N20_Ant1_2412 11N20_Ant1_2437 Page16of37 11N20_Ant1_2462 Page17of37 AppendixE:Bandedgemeasurements TestResult TestModeAntennaChNameChannelRefLevel[dBm]Result[dBm]Limit[dBm]Verdict 11BAnt1 Low24122.89-40.24≤-17.11PASS High24621.52-54.88≤-18.48PASS 11GAnt1 Low2412-2.77-40.13≤-22.77PASS High2462-2.84-42.72≤-22.84PASS 11N20Ant1 Low2412-3.21-37.56≤-23.21PASS High2462-1.63-40.53≤-21.63PASS Page18of37 TestGraphs 11B_Ant1_Low_2412 11B_Ant1_High_2462 11G_Ant1_Low_2412 Page19of37 11G_Ant1_High_2462 11N20_Ant1_Low_2412 Page20of37 11N20_Ant1_High_2462 Page21of37 AppendixF:ConductedSpuriousEmission TestResult TestModeAntennaChannel FreqRange [Mhz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict 11BAnt1 2412 Reference2.702.70---PASS 30~10002.70-70.58≤-17.3PASS 1000~265002.70-31.18≤-17.3PASS 2437 Reference0.490.49---PASS 30~10000.49-70.71≤-19.51PASS 1000~265000.49-36.22≤-19.51PASS 2462 Reference0.710.71---PASS 30~10000.71-70.42≤-19.29PASS 1000~265000.71-40.24≤-19.29PASS 11GAnt1 2412 Reference-3.76-3.76---PASS 30~1000-3.76-70.17≤-23.76PASS 1000~26500-3.76-47.11≤-23.76PASS 2437 Reference-2.09-2.09---PASS 30~1000-2.09-70≤-22.09PASS 1000~26500-2.09-45.96≤-22.09PASS 2462 Reference-3.08-3.08---PASS 30~1000-3.08-62.73≤-23.08PASS 1000~26500-3.08-49.59≤-23.08PASS 11N20Ant1 2412 Reference-2.70-2.70---PASS 30~1000-2.70-70.39≤-22.7PASS 1000~26500-2.70-47.78≤-22.7PASS 2437 Reference-1.60-1.60---PASS 30~1000-1.60-68.61≤-21.6PASS 1000~26500-1.60-46.17≤-21.6PASS 2462 Reference-1.76-1.76---PASS 30~1000-1.76-66.52≤-21.76PASS 1000~26500-1.76-51.41≤-21.76PASS Page22of37 TestGraphs 11B_Ant1_2412_0~Reference 11B_Ant1_2412_30~1000 11B_Ant1_2412_1000~26500 Page23of37 11B_Ant1_2437_0~Reference 11B_Ant1_2437_30~1000 Page24of37 11B_Ant1_2437_1000~26500 11B_Ant1_2462_0~Reference 11B_Ant1_2462_30~1000 Page25of37 11B_Ant1_2462_1000~26500 11G_Ant1_2412_0~Reference Page26of37 11G_Ant1_2412_30~1000 11G_Ant1_2412_1000~26500 11G_Ant1_2437_0~Reference Page27of37 11G_Ant1_2437_30~1000 11G_Ant1_2437_1000~26500 Page28of37 11G_Ant1_2462_0~Reference 11G_Ant1_2462_30~1000 11G_Ant1_2462_1000~26500 Page29of37 11N20_Ant1_2412_0~Reference 11N20_Ant1_2412_30~1000 Page30of37 11N20_Ant1_2412_1000~26500 11N20_Ant1_2437_0~Reference 11N20_Ant1_2437_30~1000 Page31of37 11N20_Ant1_2437_1000~26500 11N20_Ant1_2462_0~Reference Page32of37 11N20_Ant1_2462_30~1000 11N20_Ant1_2462_1000~26500 Page33of37 AppendixG:DutyCycle TestResult TestModeAntennaChannel Transmission Duration[ms] Transmission Period[ms] Duty Cycle[%] LimitVerdict 11BAnt1 24128.398.4299.64---PASS 24378.388.4199.64---PASS 24628.388.4199.64---PASS 11GAnt1 24121.391.4397.20---PASS 24371.391.4397.20---PASS 24621.401.4397.90---PASS 11N20Ant1 24121.301.3497.01---PASS 24371.301.3497.01---PASS 24621.301.3397.74---PASS Page34of37 TestGraphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 Page35of37 11G_Ant1_2412 11G_Ant1_2437 Page36of37 11G_Ant1_2462 11N20_Ant1_2412 11N20_Ant1_2437 Page37of37 11N20_Ant1_2462 ---End---

Test Report

ReportNo.:18220WC20022501FCCID:2A4SO-FLHL60Page1of39 Code:AB-RF-05-a FCCTESTREPORT ClientName:ShenzhenGreenEnergyLightingCo.,Ltd. Address: 1-5Floor,AArea,NO.303PolaoVillage,GuiyueRoad, PotouxiaCommunity,GuanlanStreet,LonghuaDist., Shenzhen,China ProductName:LEDLuminaires Date:Mar.01,2022 ShenzhenAnbotekComplianceLaboratoryLimited ReportNo.:18220WC20022501FCCID:2A4SO-FLHL60Page2of39 Code:AB-RF-05-a Contents 1.GeneralInformation ............................................................................................................................................... 5 1.1.ClientInformation ....................................................................................................................................... 5 1.2.DescriptionofDevice(EUT) ..................................................................................................................... 5 1.3.AuxiliaryEquipmentUsedDuringTest ................................................................................................... 6 1.4.DescriptionofTestModes ........................................................................................................................ 6 1.5.Listofchannels ........................................................................................................................................... 7 1.6.DescriptionOfTestSetup ......................................................................................................................... 8 1.7.TestEquipmentList .................................................................................................................................... 9 1.8.MeasurementUncertainty ....................................................................................................................... 10 1.9.DescriptionofTestFacility ...................................................................................................................... 10 2.SummaryofTestResults ................................................................................................................................... 11 3.ConductedEmissionTest ................................................................................................................................... 12 3.1.TestStandardandLimit .......................................................................................................................... 12 3.2.TestSetup .................................................................................................................................................. 12 3.3.TestProcedure .......................................................................................................................................... 12 4.RadiationSpuriousEmissionandBandEdge ................................................................................................ 15 4.1.TestStandardandLimit .......................................................................................................................... 15 4.2.TestSetup .................................................................................................................................................. 15 4.3.TestProcedure .......................................................................................................................................... 16 4.4.TestData .................................................................................................................................................... 17 5.MaximumOutputPowerTest ............................................................................................................................ 26 5.1.TestStandardandLimit .......................................................................................................................... 26 5.2.TestSetup .................................................................................................................................................. 26 5.3.TestProcedure .......................................................................................................................................... 26 5.4.TestData .................................................................................................................................................... 26 6.6DBOccupyBandwidthTest ............................................................................................................................. 27 6.1.TestStandardandLimit .......................................................................................................................... 27 6.2.TestSetup .................................................................................................................................................. 27 6.3.TestProcedure .......................................................................................................................................... 27 6.4.TestData .................................................................................................................................................... 27 7.PowerSpectralDensityTest .............................................................................................................................. 28 7.1.TestStandardandLimit .......................................................................................................................... 28 7.2.TestSetup .................................................................................................................................................. 28 7.3.TestProcedure .......................................................................................................................................... 28 7.4.TestData .................................................................................................................................................... 28 8.100kHzBandwidthofFrequencyBandEdgeRequirement ...................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

FCCID:2A4SO-FLHL60 PhotoofConductedEmissionTest PhotoofRadiationEmissionTest

Contact Information

Applicant

Steven Wong(Manager)
[email protected]0755-23760903Fax: 075536810310

Test Firm

Shenzhen Anbotek Compliance Laboratory LimitedJeff Zhu
[email protected]86-755-26064492Fax: 86-755-26014772

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz34.10 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted. This device supports 20MHz bandwidth operation only.