Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
SAVE THESE INSTRUCTIONS Operation Instructions G270 SPA Massage Chair Thanks for purchasing this product. Please read this manual instruction carefully in order to know how to use this product correctly before operation. Please pay more attention to some important safety warning and keep this manual book properly for future use. Note: Our Company reserves the right to revise the design and description of this product without any further notice. Please refer to the actual color of this product. CONTENTS 01 02 04 05 06 13 Important Safety Warning Name and function of components Function Method of usage Product specification 0302 Safety and maintenance IMPORTANT SAFETY WARNING Dont allow children to touch moveable part of this product. Please use well-grounding power supply suited to this product. Please pull out the plug after use or before cleaning to avoid injury or Damage to the product. Please operate this product according to this manual instruction. Dont use accessories which are not recommended. Dont use this product outdoors. Please read this manual instruction carefully before operation. Any other usage that is not listed in this manual instruction is forbidden. 20 minutes of usage each time is recommended. Please dont use it if the leather is broken or damaged. Please dont use it if the cover or leather is damaged. Please dont use it if the radiator hole is covered or blocked. Please dont drop anything into this product. Please dont fall asleep while using this product. Please dont use it if drunk or feel unwell. Please dont use it within one hour after having meal. Please dont make the massage function too strong for avoiding Injury. 2. Environment for usage. Please dont use it under high temperature and moist environment such as bathroom. Please dont use it immediately while the environmental temperature changes sharply. Please dont use it under heavy-dusty or caustic environment. Please dont use it where there is not enough space or not good ventilation. 3. People who are not suitable to use this product. People who are suffering from osteoporosis are not suitable to use this product. People who are suffering from heart disease or carrying electronic medical equipment such as heart pacemaker are not suitable to use this product. People who are suffering from fever are not suitable to use this product. Pregnant women or women that are in menses period are not suitable to use thisproduct. People who got injured or skin disease are not suitable to use this product. Children under 14-year old or people mentally unbalanced without being Supervised are not allowed to use this machine. People who are told by doctor to have rest or people who feel unwell are not suitable to use this product. People whose bodies are wet are forbidden to use this product. 4. Safety. Check the voltage if it is suitable to the specification of this product. Dont use wet hand to pull the plug. Dont make water go inside this product to avoid electric shock or cause damage to this product. Dont damage the wires or change the circuit of this product. Dont use wet cloth to clean the electric parts such as switch and plug. Be away from this product under power cut state to avoid injury if the power comeback suddenly. Stop using this product while it works abnormal, and please consult local agent immediately. Stop using this product if you feel unwell, and please consult health care doctor. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the Appliance. If the supply cord is damaged, it must be replaced by the manufacturer, its Service agent or similarly qualified persons in order to avoid a hazard. 5. Maintenance. This product should be maintained by certain appointed agents, users are prohibited to disassemble or maintain by themselves. Please dont forget to cut the power after usage. Dont use this product if the socket looses. If this product will be left unused for long, please curl up the wires and reserve this product in dry and dustless environment. Dont reserve this product under high temperature or near fire and avoid longtime direct sunshine. Please clean this product by dry cloth. Dont use thinner, benzene or alcohol. The mechanical components of this product are specially designed and made, it is not necessary to be specially maintained. Dont use edged res to thrust this product. Dont roll or pull this product above uneven ground, it should be lifted before moving. Please use it intermittently; dont make this product work continuously for long. 6. Solution of ordinary malfunctions. It is nature movement voice if the motor sounds while in usage. If the controller cant work normally, please check the plug and socket if they are connected strongly and make sure the switch is turned on. If the rated working time is over, the product will automatically activate the power-off button; If this product works continuously for long, the temperature protector will make the product automatically power-off, it should be used again after half an hoursr est. If the detachable cord / supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a Hazard. 1.IMPORTANT SAFETY WARNING. 0504 Name and function of components 1 3 1.Detachable pillow pad 2.Controller 3.Armrest 4.Detachable seat cushion 5.The back covering 6.Back pad 7.Tray 4 2 5 6 7 Function Function Designed with a four-wheel driven muted massage mechanism which can move up and down in the backrest. Programmed with five kinds of emulational massage functions of Shiatsu, kneading, flapping, knocking and synchronous kneading and flapping. Programmed with manual and automatic control mode…
Text truncated - open the document above for the full version.
iRestHealthScienceandTechnologyCo.,Ltd. 06-26-2024 EurofinsElectricalandElectronicTestingNA,Inc. 914WestPatapscoAvenue Baltimore,MD21230 RE:AttestationStatementsPart2.911(d)(5)(i)requestfor(FCCID:2A4VU-G270F-XXX) [iRestHealthScienceandTechnologyCo.,Ltd.](“theapplicant”)certifiesthatthe equipmentforwhichauthorizationissoughtisnot“covered”equipmentprohibited fromreceivinganequipmentauthorizationpursuanttosection2.903oftheFCCrules. Sincerely, KangminDing iRestHealthScienceandTechnologyCo.,Ltd. 06-26-2024 EurofinsElectricalandElectronicTestingNA,Inc. 914WestPatapscoAvenue Baltimore,MD21230 RE:AttestationStatementsPart2.911(d)(5)(ii)requestfor(FCCID:2A4VU-G270F-XXX) [iRestHealthScienceandTechnologyCo.,Ltd.](“theapplicant”)certifiesthat,asofthe dateofthefilingoftheapplication,theapplicantisnotidentifiedontheCoveredListas anentityproducing“covered”equipment. Sincerely, KangminDing
iRestHealthScienceandTechnologyCo.,Ltd. AgentAuthorizationLetter 2024.06.26 EurofinsElectricalandElectronicTestingNA,Inc. 914WestPatapscoAvenue Baltimore,MD21230 USA RE:LETTEROFAGENTAUTHORIZATION ToWhomItMayConcern: We,theundersigned,herebyauthorizeShenzhenMostTechnologyServiceCo.,Ltd.toact onourbehalfinallmattersrelatingtoapplicationforequipmentauthorization,includingthe signingofalldocumentsrelatingtothesematters. Wealsoherebycertifythatnopartytotheapplicationauthorizedhereunderissubjecttothe denialofbenefits,includingFCCbenefits,pursuanttoSection5301oftheAnti-DrugAbuse Actof1988,21U.S.C.853(a). Thisagreementexpiresoneyearfromthecurrentdate. Sincerely, Name:KangminDing Position:Manager CompanyName:iRestHealthScienceandTechnologyCo.,Ltd. Address:No.1118ShibaliEastRoad,DaqiaoTown,NanhuDistrict,Jiaxing, China Tel/Fax+86-573-89973638/+86-573-89973638-836 E-Mail:[email protected]
iRestHealthScienceandTechnologyCo.,Ltd. LongTermConfidentialityRequestLetter 2024.06.26 EurofinsElectricalandElectronicTestingNA,Inc. 914WestPatapscoAvenue Baltimore,MD21230 USA RE:CONFIDENTIALITYREQUESTFOR(FCCID:2A4VU-G270F-XXX) ToWhomItMayConcern: Thisletterservesasanofficialrequestforconfidentialityundersections0.457and0.459of CFR47.Wehaverequestedthatthe -e.g.Blockdiagram -e.g.SCH -e.g.OperationalDescription requiredtobesubmittedwiththisapplicationbepermanentlywithheldfrompublicreview. Theabovedocumentsarecompanyproprietaryinformationthatcouldnevergetinto thepossessionofyourcompetition. Pleasecontactmeifthereisanyinformationyoumayneed. Sincerely, Name:KangminDing Position:Manager CompanyName:iRestHealthScienceandTechnologyCo.,Ltd. Address:No.1118ShibaliEastRoad,DaqiaoTown,NanhuDistrict,Jiaxing, China Tel/Fax+86-573-89973638/+86-573-89973638-836 E-Mail:[email protected]
Modeldifferenceletter 2024.06.26 DearReviewer, ThisisanewApplicationfromiRestHealthScienceandTechnologyCo., Ltd. Model No.:G270F-XXX,G270-001,G270G-XXX,NS399VX,NS299VX,G460-10X, G490-X,G270-X,G580-3X,G210H,G260-1X,G450-21X,G450-32X,RX, R2X,OS-Lulu UseG270F-XXXforalltests . sincetheelectricalcircuitdesign,layout, componentsusedandinternalwiringwereidenticalfortheabovemodels,with differencebeingmodelnameandappearance. Thankyouforyourcooperation! Thankyouforyourcooperation! Yourssincerely, Signatory: Name:KangminDing Position:Manager CompanyName:iRestHealthScienceandTechnologyCo.,Ltd. Address:No.1118ShibaliEastRoad,DaqiaoTown,NanhuDistrict,Jiaxing, China Tel/Fax+86-573-89973638/+86-573-89973638-836 E-Mail:[email protected]
Model No.: G270F-XXX FRONT VIEW OF SAMPLE BACK VIEW OF SAMPLE Model No.: G270F-XXX LEFT VIEW OF SAMPLE RIGHT VIEW OF SAMPLE Model No.: G270F-XXX TOP VIEW OF SAMPLE BOTTOM VIEW OF SAMPLE
Model No.: G270F-XXX Page 1 of 5 INTERNAL PHOTO OF SAMPLE INTERNAL PHOTO OF SAMPLE Model No.: G270F-XXX Page 2 of 5 INTERNAL PHOTO OF SAMPLE PCB INTERNAL PHOTO OF SAMPLE PCB Model No.: G270F-XXX Page 3 of 5 INTERNAL PHOTO OF SAMPLE PCB INTERNAL PHOTO OF SAMPLE PCB Model No.: G270F-XXX Page 4 of 5 Model No.: G270F-XXX Page 5 of 5 Antenna
ALPHA's reports is using a digital certificate that is trusted on Adobe's official server. If there is no digital certificate or the digital certificate shows damaged in your report. Please do not accept the report. E-mail: [email protected] Tel: 4008-3008-95 Website: http://www.a-lab.cn FCC TEST REPORT FCC ID: 2A4VU-G270F-XXX On Behalf of iRest Health Science and Technology Co., Ltd. Spa Massage Chair Model No.: G270F-XXX, G270-001, G270G-XXX, NS399 VX, NS299VX, G460-10X, G490-X, G270-X, G580-3X, G210H, G260-1X, G450-21X, G450-32X, RX, R2X, OS-Lulu Prepared for : iRest Health Science and Technology Co., Ltd. Address : No. 1118 Shibali East Road, Daqiao Town, Nanhu District, Jiaxing,China Prepared By : Shenzhen Alpha Product Testing Co., Ltd. Address : Building i, No.2, Lixin Road, Fuyong Street, Bao'an District, 518103, Shenzhen, Guangdong, China Report Number : A2302159-C01-R01 Date of Receipt : July 1, 2024 Date of Test : July 1, 2024 – July 4, 2024 Date of Report : July 4, 2024 Version Number : V0 Test Result : Pass Page 2 of 20 Report No.: A2302159-C01-R01 TABLE OF CONTENTS Description Page 1. Test Result Summary ................................................................................................................................ 5 2. EUT Description ......................................................................................................................................... 6 2.1. Description of Device (EUT) ................................................................................................................ 6 2.2. Accessories of Device (EUT) .............................................................................................................. 7 2.3. Tested Supporting System Details ...................................................................................................... 7 2.4. Block Diagram of Connection between EUT and Simulators.............................................................. 7 2.5. Description of Test Modes................................................................................................................... 7 2.6. Test Conditions ................................................................................................................................... 7 2.7. Test Facility ......................................................................................................................................... 8 2.8. Measurement Uncertainty ................................................................................................................... 8 3. Test Results and Measurement Data ....................................................................................................... 9 3.1. RF Exposure Test ............................................................................................................................... 9 3.1.1. Test Specification ....................................................................................................................... 9 3.1.2. Test Instruments ....................................................................................................................... 10 3.1.3. Test data ................................................................................................................................... 10 4. Photos of test setup ................................................................................................................................ 12 5. Photographs of EUT ................................................................................................................................ 20 Page 3 of 20 Report No.: A2302159-C01-R01 TEST REPORT DECLARATION Applicant : iRest Health Science and Technology Co., Ltd. Address : No. 1118 Shibali East Road, Daqiao Town, Nanhu District, Jiaxing,China Manufacturer : iRest Health Science and Technology Co., Ltd. Address : No. 1118 Shibali East Road, Daqiao Town, Nanhu District, Jiaxing,China EUT Description : Spa Massage Chair (A) Model No. : G270F-XXX, G270-001, G270G-XXX, NS399 VX, NS299VX, G460-10X, G490-X, G270-X, G580-3X, G210H, G260-1X, G450-21X, G450-32X, RX, R2X, OS-Lulu (B) Trademark : iRest Measurement Standard Used: FCC CFR Title 47 Part 15 Subpart C FCC KDB 680106 D01 Wireless Transfer v04 The device described above is tested by Shenzhen Alpha Product Testing Co., Ltd. to determine the maximum emission levels emanating from the device and the severe levels of the device can endure and its performance criterion. The test results are contained in this test report and Shenzhen Alpha Product Testing Co., Ltd. is assumed full responsibility for the accuracy and completeness test. Also, this report shows that the EUT is technically compliant with the KDB 680106 D01 requirements. This report applies to above tested sample only. This report shall not be reproduced in parts without written approval of Shenzhen Alpha Product Testing Co., Ltd. Tested by (name + signature).............: Yannis Wen Project Engineer Approved by (name + signature).......: Jack Xu Project Manager Date of issue...... .......................: July 4, 2024 Page 4 of 20 Report No.: A2302159-C01-R01 Revision History Revision Issue Date Revisions Revised By V0 July 4, 2024 Initial released Issue Yannis Wen Page 5 of 20 Report No.: A2302159-C01-R01 1. Test Result Summary Requirement CFR 47 Section Result RF EXPOSURE §1.1307(b)(1) & KDB680106 PASS Note: 1. PASS: Test item meets the requirement. 2. Fail: Test item does not meet the requirement. 3. N/A: Test case does not apply to the test object. 4. The test result judgment is decided by the limit of test standard. Page 6 of 20 Report No.: A2302159-C01-R01 2. EUT Description 2.1. Description of Device (EUT) EUT Name : Spa Massage Chair Model No. : G270F-XXX, G270-001, G270G-XXX, NS399 VX, NS299VX, G460-10X, G490-X, G270-X, G580-3X, G210H, G260-1X, G450-21X, G450-32X, RX, R2X, OS-Lulu DIFF : Only difference is the appearance and shape, and…
Text truncated - open the document above for the full version.
ShenzhenMostTechnologyServiceCo.,Ltd. No.5,2ndLangshanRoad,NorthDistrict,Hi-techIndustrialPark,Nanshan, Shenzhen,Guangdong,China. TESTREPORT FCCPART15.209 ReportReferenceNo. ....................... : FCCID.. ............................................... : MTEB22120327-R 2A4VU-G270F-XXX Compiledby (position+printedname+signature)..:FileadministratorsAlisaLuo Supervisedby (position+printedname+signature)..:TestEngineerSunnyDeng Approvedby (position+printedname+signature) .. : ManagerYvetteZhou Dateofissue ......................................... :Apr.07,2024 RepresentativeLaboratoryName . :ShenzhenMostTechnologyServiceCo.,Ltd. Address.................................................: No.5,2ndLangshanRoad,NorthDistrict,Hi-techIndustrialPark, Nanshan,Shenzhen,Guangdong,China. Applicant’sname...............................:iRestHealthScienceandTechnologyCo.,Ltd. Address ................................................. : No.1118ShibaliEastRoad,DaqiaoTown,NanhuDistrict, Jiaxing,China Testspecification/Standard............: FCCRulesandRegulationsPart15SubpartC(Section15.209), ANSIC63.10:2013 TRFOriginator ...................................... :ShenzhenMostTechnologyServiceCo.,Ltd. ShenzhenMostTechnologyServiceCo.,Ltd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenMostTechnologyServiceCo.,Ltd.isacknowledgedascopyrightownerandsourceofthe material.ShenzhenMostTechnologyServiceCo.,Ltd.takesnoresponsibilityforandwillnotassume liabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. Testitemdescription ........................ : SpaMassageChair TradeMark ............................................ : iRest Model/Typereference.........................: G270F-XXX ListedModels ...................................... : G270-001,G270G-XXX,NS399VX,NS299VX,G460-10X, G490-X,G270-X,G580-3X,G210H,G260-1X,G450-21X, G450-32X,RX,R2X,OS-Lulu ModulationType..................................: MSK OperationFrequency..........................: 110-205KHz Rating.....................................................: AC120V/60Hz HardwareVersion...............................: V1.0 SoftwareVersion...............................: V1.0 Result.....................................................:PASS ReportNo.:MTEB22120327-RPage 2 of 22 TESTREPORT EquipmentunderTest:SpaMassageChair Model/Type:G270F-XXX ListedModels: G270-001,G270G-XXX,NS399VX,NS299VX,G460-10X, G490-X,G270-X,G580-3X,G210H,G260-1X,G450-21X, G450-32X,RX,R2X,OS-Lulu Remark Onlydifferenceistheappearanceandshape,andthewirelesspart hasnodifference.SoallthetestwereperformedonthemodelG270F- XXX Applicant: iRestHealthScienceandTechnologyCo.,Ltd. Address: No.1118ShibaliEastRoad,DaqiaoTown,NanhuDistrict, Jiaxing,China Manufacturer: iRestHealthScienceandTechnologyCo.,Ltd. Address: No.1118ShibaliEastRoad,DaqiaoTown,NanhuDistrict, Jiaxing,China TestResult : PASS Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetest laboratory. ReportNo.:MTEB22120327-RPage 3 of 22 Contents 1.REVISIONHISTORY.........................................................................................................................4 2.TESTSTANDARDS............................................................................................................................5 3.SUMMARY...............................................................................................................................................6 3.1.GeneralRemarks.........................................................................................................................................6 3.2.ProductDescription....................................................................................................................................6 3.3.EquipmentUnderTest................................................................................................................................6 3.4.ShortdescriptionoftheEquipmentunderTest(EUT)............................................................................6 3.5.EUToperationmode....................................................................................................................................6 3.6.BlockDiagramofTestSetup......................................................................................................................7 3.7.TestItem(EquipmentUnderTest)Description*.......................................................................................7 3.8.AuxiliaryEquipment(AE)Description.......................................................................................................7 3.9.AntennaInformation*..................................................................................................................................7 3.10.EUTconfiguration......................................................................................................................................7 3.11.Modifications..............................................................................................................................................7 4.TESTENVIRONMENT.......................................................................................................................8 4.1.Addressofthetestlaboratory...................................................................................................................8 4.2.Environmentalconditions...........................................................................................................................8 4.3.TestDescription...........................................................................................................................................9 4.4.Statementofthemeasurementuncertainty.............................................................................................9 4.5.EquipmentsUsedduringtheTest..........................…
Text truncated - open the document above for the full version.
产品承认书 Productacknowledgment 版本编号:V1.3 Versionnumber:V1.3 客户名称: ClientName: 产品型号:G509(P03) ProductModelNumber:G509(P03) 产品类型: ProductType: 拟定 Protocol 审核 Examineandverify 批准 Approve 客户确认签名Signone`s日期Data Clientaffirmname 目录Catalogue 1、无线充电器发射端描述Wirelesschargertransmittingterminaldescription 2、发射端电器性能Transmittingterminalelectricalperformance 2.1发射端输入Transmittingterminalinput 2.2发射端额定输出Transmittingterminal ratedoutput 2.3发射端工作指示状态LaunchtheWorkinstructionsstate 3、发射端线圈参数Transmittingterminalcoifsparameter 3.1线圈参数Theparameterofcoil 3.2发射端线圈尺寸Transmittingterminalcoifssize 4、性能Performance 4.1发射端性能Transmittingterminalperformance 5、发射端原理Transmittingterminalprinciple 5.1原理图Schematicdiagram 6、PCBA 6.1发射端PCB原件位置正面TransmittingterminalPCBoriginallocationfront 6.2发射端PCB背面TransmittingterminalPCBback 6.3发射端PCB布线图正面TransmittingterminalPCBwiringdiagramfront 6.4发射板尺寸Launchplatesize 7、物料清单 BOM 7.1接收端清单Receivingendinventory 8、气候条件规格Weatherconditionsstandard 8.1条件Condition 1、无线充电器发射端描述Wirelesschargertransmittingterminal description 本产品适合手机、家具等产品实现无线充电功能。以及基于其他 5V2A 的电池无线充电或者无 线供电。 Thisproductissuitableformobilephones,furnitureforwirelesscharging.Andbasedonthe otherbatteryof5V2Aforwirelesschargingorwirelesspowersupply. 2、发射端电器性能Transmittingterminalelectricalperformance 2.1发射端输入Transmittingterminalinput 输入电压范围 Inputvoltagerange 9.6V----40VDC 额定输入电压范围 RangeInputvoltagerange 11V----32VDC 最大输入电流 Maximumincomingcurrent(adapter) 0.5Amax.在满载条件下 0.5Amax.Intheconditionoffullload 2.2发射端额定输出Transmittingterminal ratedoutput 额定输出电压范围 RangeOutputvoltagerange 5V----9VDC 最大输出电流 MaximumcurrentOutput 1.1Amax.在满载条件下 1.1Amax.Intheconditionoffullload 2.3发射端工作指示状态LaunchtheWorkinstructionsstate 指示灯 Indicatorlight 空闲状态 Idlestate 充电状态 ChargingState 保护状态 ProtectionState 绿色 Green 常亮 Open 熄灭 Close 熄灭 Close 红色 Red 熄灭 Close 常亮 Open 闪烁 Glitter 3、发射端线圈参数 Transmittingterminal c oil`sparameter 3.1线圈参数Theparameterofcoil 测试项目 Testitem 参数特征 Parametercharacteristic 建议误差值 Suggesterrorvalue (μH)6.310% (mΩ) 75.0 MAX最大 3.2发射端线圈尺寸Transmittingterminalcoil'ssize ABCDEFGHIJ 10± 2 3± 1.5 100± 2 20.5± 0.5 43± 2 5.3± 0.5 50± 1 1.25MA X 0.8± 0.15 2.6MA X 单位(Unit):毫米(mm) 圈数 Turn s 线径 WireDia. 绕线方式 疏/密 Wdg.Type Spred/Clos e 绕线方向 Wdg.Direction 相交是/ 否 Intersec t Yes/Not 线圈正/反贴 Coil Positive/Anti Paste 10TS 0.08*105P丝包 线 (Silk-Covere dWire) 密绕 (Close) 逆时针 (Anticlockwise) 是(Yes)反贴 (Anti-Paste) 所有材料要求合格ROHS标准 4、发射端线圈参数 Transmittingterminal c oil`sparameter 4.1发射端性能Transmittingterminalperformance ParameterNotesandConditions MinTypeMax Unit INPUTCHARACTERISTICS VINInputVoltage 112432 IINInputCurrent VIN=Nom,IOUT=Max 0.250.5 A InputNoLoadCurrent VIN=Nom,IOUT=0A2050 mA OUTPUTCHARACTERISTICS VOUT OutputVoltage VIN=Nom,IOUT=Nom599.1 V OutputRipple VIN=Nom,IOUT=Max 200 mVPP IOUT VIN=MintoMaxVIN=MintoMax O1A 5、发射端原理图Transmittingterminalprinciple 5.1原理图(部分)SchematicDiagram(Part) 6、PCBA 6.1发射端PCB原件位置正面TransmittingterminalPCBoriginallocationfront 6.2发射端 PCB 背面 TransmittingterminalPCBback 6.3发射端PCB布线图正面TransmittingterminalPCBwiringdiagramfront 6.4发射板尺寸Launchplatesize 35X75mm 7、物料清单BOM 7.1 发射端清单 transmittingterminalendinventory 序 号 CommentDesignatorFootprintQuantity 1 线路板 1 2 47nF/10%/50VC2,C10,C18,C19,C20HT_0603_C5 3 10uF/10%/16VC3,C24,C26HT_0805_C3 4 0.1uF/10%/50VC4,C7,C9HT_0603_C3 5 2.2nF/10%/50VC6,C17HT_0603_C2 6 1nF/10%/50VC8HT_0603_C1 7 1uF/10%/16VC11,C13,C14HT_0603_C3 8 2.2uF/10%/16VC12HT_0603_C1 9 15nF/50VC15,C16,C21,C23HT_0603_C4 10 22uF/10%/16VC25,C27HT_0805_C2 11 SS36D1SMA1 12 1N5819(k14)D2,D3,D4SOD-1233 13 1206/3A/60VF1HT_1206_R1 14 IP6522UIC1SO-81 15 IP6808IC2HT_IP68081 16 LM321IC3HT_SOT_23_51 17 KJ0603QDIC4,IC5HT_KJ0603QD2 18 LED_Red红 LED1HT_0603_R1 19 LED_Green 绿 LED2HT_0603_R1 20 SDNT1608X103F3450FTFNTC1HT_0603_R1 21 10mR/1%R1HT_1206_R1 22 1K/1%R2,R7,R16HT_0603_R3 23 2R/5%R3,R4,R5,R18,R19,R20,R21HT_0603_R7 24 10K/1%R10HT_0603_R1 25 3.3K/1%R8,'R9,R13HT_0603_R3 26 33K/1%R11HT_0603_R1 27 100K/1%R12,R17HT_0603_R2 28 100R/5%R14HT_0603_R1 29 20mR/1%R15HT_1206_R1 30 100Ω电感 LF1HT_1206_R1 31 SMBJ30ATVS1HT_SMBJ_D1 32 22uH/5AL1HT_10X101 33 A11A1HT_SIP21 34 220uF/16V高频低阻(蓝色) C1HT_220UF/16V1 35 100uF/35V高频低阻(蓝色) C5HT_100UF/35V1 36 CBB电容 C22404J/100V1 37 Header2 带卡扣( HA-2WAP ) P2HT_2.54MM_2P_W1 8、气候条件规格Weatherconditionsstandard 8.1气候条件Weathercondition 工作温度:0°C~40°C. Operatingtemperature0°C~40°C. 工作湿度:10%~80%(没有水气凝结) Operatinghumidity:10%~80%(Nosteamcondensation) 存储温度:-20°C~70°C Storagetemperature:-20°C~70°C 存储湿度:to20,000ft. Storagehumidity:to20,000ft.
Model No.: G270F-XXX CE TEST SETUP RE TEST SETUP Model No.: G270F-XXX RE TEST SETUP
No.5, 2nd Langshan Road, North District, · Shenzhen, Guangdong · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.11 MHz - 0.205 MHz | - |

Spa Massage Chair
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Spa Massage Chair
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Massage Chair
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter