FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shen zhen shi jing cheng xin dian zi ke ji you xian gong si/
  3. 2A52C-EASY30

2A52C-EASY30Proxmark3 EASY3.0

Shen zhen shi jing cheng xin dian zi ke ji you xian gong si
Proxmark3 EASY3.0 - FCC ID 2A52C-EASY30 - Shen zhen shi jing cheng xin dian zi ke ji you xian gong si
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Nov 22, 2023
Application Purpose
Original Equipment
Date of Application
Nov 22, 2023
Equipment Note
Proxmark3 EASY3.0
Frequency Range
0.11000000 - 0.20500000
Company
Shen zhen shi jing cheng xin dian zi ke ji you xian gong si
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 PM3 Easy3.0 Quick start guide ....................................................................................... 3 I.Hardware description .................................................................................................. 4 1. Installation of equipment:................................................................................. 4 A. Install the copper pillar first: .................................................................... 4 B. Install the upper plate: ................................................................................ 5 C. Install low frequency antenna: ................................................................. 5 D. Attach a protective film:.............................................................................. 2. IC high frequency card placement location: .................................................. 6 3. ID low frequency card placement location:.................................................... 7 4. Other parameters: ............................................................................................... 8 II.D r i v e r I n s t a l l a t i o n ............................................................................................ 9 Reasons for unsuccessful driver installation and solutions: ......................... 12 III.Quickly test basic functions ................................................................................. 13 1. Antenna voltage test: ....................................................................................... 13 2. Read high frequency card test: ...................................................................... 14 3. Read low frequency card test: ........................................................................ 14 IV.Card basics ................................................................................................................. 16 Common cards are: ............................................................................................... 16 M1 S50 card introduction ....................................................................................... 16 M1 UID card introduction ....................................................................................... 18 M1 FUID, CUID card introduction ......................................................................... 19 ID, HID, card introduction ....................................................................................... 19 T5577 card introduction .......................................................................................... 19 V.Card security test (whether it can be copied) ...................................................... 23 2 Overall process .......................................................................................................... 23 IC card ideas:........................................................................................................... 24 1. Try to get any key in the 16 sectors of the card ..................................... 24 2. Obtain all sector keys through known keys ........................................... 32 3. Read the card data to the computer ......................................................... 34 4. Read the card data in the computer and write it to the UID card ...... 34 5. Check the data and complete the clone ................................................... 35 VI.Low frequency card operation: ........................................................................... 35 1. R e a d I D , H I D , I N D A L A a n d o t h e r c a r d s: ................................ 35 2. W r i t e d i f f e r e n t t y p e s t o T 5 5 7 7 c a r d t o c l o n e t h e c a r d: 36 Clone into ID card: ......................................................................................... 36 Clone into HID card: ...................................................................................... 37 Clone into INDALA card: ............................................................................... 37 VII.Software introduction: ........................................................................................ 38 VIII.Matters needing attention: .............................................................................. 38 1. Hardware matters: ............................................................................................ 38 2. Software matters: ............................................................................................. 39 a) PC software .................................................................................................... 39 b) Device firmware ............................................................................................ 40 IX.Instruction introduction .......................................................................................... 40 3 PM3 Easy3.0 quick start guide 4 一. Hardware description 1. 1. Installation of equipment: A. Install the copper pillar first: 5 B. And then install the upper plate: Screw the screws and lead copper posts on the upper plate C. Install low frequency antenna: Tip: The low-frequency antenna can also be installed in four symmetrical positions on the top, bottom, left, and right, and you can choose according to your preferences. In the recommended way, the two antennas have the least influence on each other. 6 2. IC HF card placement location: The IC card is recommended to be placed on the back of the device and aligned with the device, which is the most stable. 7 Place the card as shown in the picture above. Normally, there is no problem. In addition, please keep away from metal objects and metal tabletops. Individual keychains or small cards with poor signals can easily interrupt the reading and writing. At this time, you can read the card as shown in the figure below and put the low-frequency antenna under the high-frequency antenna to solve the problem. 3. ID low frequency card placement location: 8 Jus…

Text truncated - open the document above for the full version.

Attestation Statements

(Shen zhen shi jing cheng xin dian zi ke ji you xian gong si) (November 20, 2023) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID: 2A52C-EASY30) [Shen zhen shi jing cheng xin dian zi ke ji you xian gong si] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, (Applicant signature) (Applicant printed name) guohao Chen (Shen zhen shi jing cheng xin dian zi ke ji you xian gong si) (November 20, 2023) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCC ID: 2A52C-EASY30) [Shen zhen shi jing cheng xin dian zi ke ji you xian gong si] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) guohao Chen

Cover Letter(s)

Shen zhen shi jing cheng xin dian zi ke ji you xian gong si (November 17, 2023) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (Proxmark3 EASY3.0 / EASY3.0 / FCC ID: 2A52C-EASY30) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☒ Internal Photos ☐ NOTE 1 ☒ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No required to be submitted with this application be permanently withheld from public review. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely, Signature: Name: guohao Chen Title: Manager

Cover Letter(s)

Shen zhen shi jing cheng xin dian zi ke ji you xian gong si (November 17, 2023) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize (Shenzhen CTB Testing Technology Co., Ltd.) to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Signature: Name: guohao Chen Title: Manager

External Photos

Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 4 Model: EASY3.0 External Photos Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 4 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 3 of 4 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 4 of 4

ID Label/Location Info

FCC ID LABEL: Label Location: FCC ID: 2A52C-EASY30 Model No.: EASY3.0

Internal Photos

Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 2 Model: EASY3.0 Internal Photos 125K ANT 13.56MHz ANT Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 2

RF Exposure Info

FCC §15.247 (i), §2.1091 – RF Exposure FCC ID: 2A52C-EASY30 Applied procedures / limit According to FCC §15.247(i) and §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. Limits for Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm 2 ) Averaging Time |E| 2 ,|H| 2 or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842 / f 4.89 / f (900 / f)* 6 30-300 61.4 0.163 1.0 6 300-1500 F/300 6 1500-100,000 5 6 Note: ƒ is frequency in MHz * = Power density limit is applicable at frequencies greater than 100 MHz Limits for General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm 2 ) Averaging Time |E| 2 ,|H| 2 or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f)* 30 30-300 27.5 0.073 0.2 30 300-1500 F/1500 30 1500-100,000 1.0 30 Note: f = frequency in MHz * = Plane-wave equivalent power density MPE PREDICTION Predication of MPE limit at a given distance, Equation from OET Bulletin 65, Edition 97-01 Where: S = power density P = power input to antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna,R=20cm Test Result of RF Exposure Evaluation 13.56MHz Note:dbm=dbuv/m-95.2=101.07-95.2=5.87dBm(ERP), so the conduct peak power=5.87- 1=4.87dBm 125kHz+13.56MHz supported simultaneous transmission: 125kHz+13.56MHz MIMO : ∑MPE Ratio =0.0062+0.0008=0.007≤1, So passed. Modes& Channel Freq. (MHz) Tune up Produce power Maximu m peak output power (dBm) Output power to antenna (mW) Antenna Gain (numeric) Power Density (S) (mW/ cm2) Limit (mW / cm2 ) Result 13.56MHz ASK 4±1 5 3.1623 1.2589 (1dBi) 0.0008 1 Pass

RF Exposure Info

Shenzhen CTB Testing Co., Ltd. FCC ID: 2A52C-EASY30 Portable device Per § 1.1307(b)(3)(i)(A), a single RF source is exempt RF device (from the requirement to show data demonstrating compliance to RF exposure limits, as previously mentioned) if the available maximum time-averaged power is no more than 1 mW, regardless of separation distance. This exemption applies to all operating configurations and exposure conditions, for the frequency range 100 kHz to 100 GHz, regardless of fixed, mobile, or portable device exposure conditions. This is a standalone exemption, and it cannot be applied in conjunction with any other test exemption. 125kHz: Note:dbm=dbuv/m-95.2=73.14-95.2=-22.06dBm(EIRP), so the maximun averaged power power=0.0062mW Conclusion: For the max result : 0.0062≤ FCC Limit 1mW for 1g SAR. 125kHz+13.56MHz supported simultaneous transmission: 125kHz+13.56MHz MIMO : ∑MPE Ratio =0.0062+0.0008=0.007≤1, So passed.

Test Report

ANT PHTOT All measurements were performed radiated and therefore additional antenna gain documentation is not required. 13.56MHz ANT 125KHz ANT

Test Report

TEST REPORT Compiled by: Reviewed by: Approved by: Zhou Kui Arron Liu Bin Mei / Director Note: If there is any objection to the inspection results in this report, please submit a written report to the company within 15 days from the date of receiving the report. The test report is effective only with both signature and specialized stamp. This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen CTB Testing Technology Co., Ltd. this report can’t be reproduced except in full. The tested sample(s) and the sample information are provided by the client. “*” indicates the testing items were fulfilled by subcontracted lab. “#” indicates the items are not in CNAS accreditation scope. Product Name: Proxmark3 EASY3.0 FCC ID: 2A52C-EASY30 Trademark: N/A Model Number: EASY3.0 Prepared For: Shen zhen shi jing cheng xin dian zi ke ji you xian gong si Address: Bao an qu, Sha jing street, Gong he she qu, tong fu road 3dong 3-7E, shen zhen city, guangdong province, China Manufacturer: Shenzhen Liju Technology Co.,Ltd Address: Rong 502, jinghongpeng Daxia, No.1, South America west road, xiner community, Xinqiao street, Bao an district, Shenzhen, China Prepared By: Shenzhen CTB Testing Technology Co., Ltd. Address: 1&2/F., Building A, No.26, Xinhe Road, Xinqiao, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, China Sample Received Date: Nov. 08, 2023 Sample tested Date: Nov. 08, 2023 to Nov. 13, 2023 Issue Date: Nov. 13, 2023 Report No.: CTB231113060RFX Test Standards FCC Part 15 C Test Results PASS Remark: This is 125kHz test report. Shenzhen CTB Testing Technology Co., Ltd. Report No.:CTB231113060RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 22 TABLE OF CONTENTS 1. GENERAL INFORMATION ........................................................................................................................ 3 1.1. Report information ................................................................................................................................. 3 1.2. Measurement Uncertainty ..................................................................................................................... 3 1.3. Test Facility ........................................................................................................................................... 3 1.4. Test Uncertainty .................................................................................................................................... 4 2. PRODUCT DESCRIPTION ......................................................................................................................... 5 2.1. EUT Description .................................................................................................................................... 5 2.2. Block Diagram of EUT Configuration ..................................................................................................... 5 2.3. Test Conditions ..................................................................................................................................... 5 2.4. DescriptionOfSupport Units (Conducted Mode) .................................................................................... 6 3. TEST RESULTS SUMMARY ...................................................................................................................... 7 4. TEST EQUIPMENT USED .......................................................................................................................... 8 4.1. MEASUREMENT INSTRUMENTS LIST ............................................................................................... 8 5. CONDUCTED EMISSION TEST ............................................................................................................... 10 5.1. Block Diagram of Test Setup ............................................................................................................... 10 5.2. Test Standard ...................................................................................................................................... 10 5.3. Conducted Emission Limit ................................................................................................................... 10 5.4. EUT Configuration on Test .................................................................................................................. 10 5.5. Operating Condition of EUT ................................................................................................................ 10 5.6. Test Procedure .................................................................................................................................... 11 5.7. Test Result .......................................................................................................................................... 11 6. RADIATED EMISSION MEASUREMENT ................................................................................................ 14 6.1. Block Diagram of Test Setup ............................................................................................................... 14 6.2. Test Standard ...................................................................................................................................... 15 6.3. EMI Test Receiver Setup..................................................................................................................... 15 6.4. Test Procedure .................................................................................................................................... 15 6.5. Test Result .......................................................................................................................................... 15 7. OCCUPIED BANDWIDTH ........................................................................................................................ 19 7.1. Block Diagram of Test Setup .........................…

Text truncated - open the document above for the full version.

Test Setup Photos

Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 2 Model: EASY3.0 Radiated Emission 30MHz-1GHz 9KHz-30MHz Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 2 Conducted emissions

Contact Information

Applicant

guohao Chen
[email protected]13538218145Fax: 13538218145

Test Firm

Shenzhen CTB Testing Technology Co., Ltd.Rita Xiao
[email protected]86-13538218145

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.11 MHz - 0.205 MHz-
Confidentiality
Long Term
Grant Notes
The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter device.