FCCCaution: Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowingtwo conditions:(1)thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustacceptany interferencereceived,includinginterferencethatmaycauseundesiredoperation. Anychangesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoid theuser'sauthoritytooperatetheequipment. NOTE:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice, pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainst harmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,usesandcanradiateradio frequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmful interferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurina particularinstallation. Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbe determinedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrecttheinterference byoneormoreofthefollowingmeasures: --Reorientorrelocatethereceivingantenna. --Increasetheseparationbetweentheequipmentandreceiver. --Connecttheequipmentintoanoutletonacircuitdifferent fromthattowhichthereceiverisconnected. --Consultthedealeroranexperiencedradio/TVtechnicianforhelp. TomaintaincompliancewithFCC’sRFExposureguidelines,Thisequipmentshouldbeinstalledand operatedwithminimumdistancebetween20cmtheradiatoryourbody:Useonlythesuppliedantenna. FCCID:2A57V-JC
ShenzhenJichengPhotoelectricTechnologyCo.,Limited OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:2022-07-04 Subject;RequestforConfidentiality FCCID:2A57V-JC ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthesedocuments mightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:YongpingZhou Title:Manager
version01 ShenzhenJichengPhotoelectricTechnologyCo.,Limited Modeldifferencestatement Itisherebydeclaredthattheproduct ProductName:LEDWALLLIGHT Model:JC-TX40-TYW-001 ListedModel(s):JC-TX80-TYW-001,JC-TX120-TYW-001 Mark::JICHENG AllmodelshavethesamecircuitandRFmodule,exceptforthedifferentappearanceshapeandcolor. Sincerely, Signature [YongpingZhou] [Manager] [ShenzhenJichengPhotoelectricTechnologyCo.,Limited]
ShenzhenJichengPhotoelectricTechnologyCo.,Limited LetterofAuthorization Company:ShenzhenJichengPhotoelectricTechnologyCo.,Limited Address:6F,BuildingC,UnigreatIndustrialPark,No.10ofShihuanRoad, ShiyanTown,Shenzhen,China ProductName:LEDWALLLIGHT ModelNumber:JC-TX40-TYW-001,JC-TX80-TYW-001,JC-TX120-TYW-001 Trademark:JICHENG FCCIdentifier:2A57V-JC WeauthorizeMiCOMLabsInc,575BoulderCourt,Pleasanton,California94566, USA,toactonourbehalfonallmattersconcerningtheabovenamedequipment. AnyindividualwithinMiCOMLabsisauthorizedtoactonourbehalfandtake actionontheapplication. WedeclarethatMiCOMLabsInc,575BoulderCourt,Pleasanton,California 94566,USA,isallowedtoforwardallinformationrelatedtotheapprovalproject totheFederalCommunicationCommissionandtodiscussanyissues concerningtheapprovalapplication.AnyandallactscarriedoutbyMiCOMLabs onourbehalfshallhavethesameeffectasactsofourown. Name:YongpingZhouDate:July04.2022 Signatureofapplicant:
Page1of4FCCID:2A57V-JC ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity ExternalPhotosoftheEUT Fig.1 Fig.2 Page2of4FCCID:2A57V-JC ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of4FCCID:2A57V-JC ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of4FCCID:2A57V-JC ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7
Page1of1FCCID:2A57V-JC ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION (Size:L4.5cmx3.5cm) LabelLocation LEDWALLLIGHT Model:JC-TX40-TYW-001 FCCID:2A57V-JC
Page1of5FCCID:2A57V-JC ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity InternalPhotosoftheEUT Fig.1 Fig.2 Page2of5FCCID:2A57V-JC ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of5FCCID:2A57V-JC ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 WIFIANT Page4of5FCCID:2A57V-JC ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8 Page5of5FCCID:2A57V-JC ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.9
Page 1 of 4 FCCID:2A57V-JC ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCRFExposureEvaluation 1.ProductInformation FCCID2A57V-JC ProductnameLEDWALLLIGHT ModelnumberJC-TX40-TYW-001,JC-TX80-TYW-001,JC-TX120-TYW-001 PowersupplyInput:AC100-265V,50/60Hz,26W ModulationType IEEE802.11b:DSSS(CCK,DQPSK,DBPSK) IEEE802.11g:OFDM(64QAM,16QAM,QPSK,BPSK) IEEE802.11n:OFDM(64QAM,16QAM,QPSK,BPSK) AntennaTypeInternalAntenna AntennaGain0dBi(Max.) HardwareversionV1.0 Softwareversion1.3.19 FCCOperationfrequency2412MHz-2462MHz ExposurecategoryGeneralpopulation/uncontrolledenvironment EUTTypeProductionUnit DeviceTypeMobileDevices 2.EvaluationMethod SystemsoperatingundertheprovisionsofFCC47CFRsectionshallbeoperatedinamannerthatensures thatthepublicisnotexposedtoradiofrequencyenergylevelinexcessoftheCommission’sguidelines. Inaccordancewith47CFRFCCPart2SubpartJ,section2.1091thisdevicehasbeendefinedasmobile devicewherebyadistanceof0.2mnormallycanbemaintainedbetweentheuserandthedevice,andbelow RFPermissibleExposurelimitshallcomplywith. InaccordancewithKDB447498D01forSimultaneoustransmissionMPEtestexclusionapplieswhenthesum oftheMPEratiosforallsimultaneoustransmittingantennasincorporatedinahostdevice,basedonthe calculated/estimated,numericallymodelledormeasuredfieldstrengthsorpowerdensity,is≤1.0.TheMPE ratioofeachantennaisdeterminedattheminimumtestseparationdistancerequiredbytheoperating configurationsandexposureconditionsofthehostdevice,accordingtotheratiooffieldstrengthsorpower densitytoMPElimit,atthetestfrequency.Eitherthemaximumpeakorspatiallyaveragedresultsfrom measurementsornumericalsimulationsmaybeusedtodeterminetheMPEratios.Spatialaveragingdoesnot applywhenMPEisestimatedusingsimplecalculationsbasedonfar-fieldplane-waveequivalentconditions. Theantennainstallationandoperatingrequirementsforthehostdevicemustmeettheminimumtest separationdistancesrequiredbyallantennas,inbothstandaloneandsimultaneoustransmissionoperations, tosatisfycompliance. Page 2 of 4 FCCID:2A57V-JC ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 3.Limit 3.1ReferEvaluationMethod ANSIC95.1–1999:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoRadioFrequency ElectromagneticFields,3kHzto300GHz. FCCKDBpublication447498D01General1RFExposureGuidancev06:MobileandPortableDevicesRF ExposureProceduresandEquipmentAuthorizationPolicies. FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1091:Radiofrequencyradiationexposureevaluation:mobiledevices 3.2Limit LimitsforMaximumPermissibleExposure(MPE)/ControlledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100)* (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 LimitsforMaximumPermissibleExposure(MPE)/UncontrolledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100)* (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequencyinMHz *=Plane-waveequivalentpowerdensity 4.MPECalculationMethod PredicationofMPElimitatagivendistance Equationfrompage18ofOETBulletin65,Edition97-01 S=PG/4πR² Where:S=powerdensity P=powerinputtoantenna G=powergainoftheantennainthedirectionofinterestrelativetoanisotropicradiator R=distancetothecenterofradiationoftheantenna 5.AntennaInformation ArtemisAntennacanonlyuseantennascertificatedasfollowsprovidedbymanufacturer; Internal Identification Antennatypeand antennanumber Operatefrequency band Maximumantenna gain Note AntennaInternalAntenna2400MHz-2500MHz0dBiWIFIAntenna Page 3 of 4 FCCID:2A57V-JC ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 6.ConductedPower <2.4GWLANMaxConductedPower> ModeChannelFrequency(MHz) MaxConductedPower (dBm) IEEE802.11b 1241215.96 6243715.82 11246215.61 IEEE802.11g 1241214.19 6243713.93 11246213.81 IEEE802.11n HT20 1241213.17 6243712.74 11246214.57 IEEE802.11n HT40 3242211.8 6243711.48 9245211.28 7.ManufacturingTolerance <2.4GWIFI> 11B(Peak) ChannelChannel1Channel6Channel11 Target(dBm)15.015.015.0 Tolerance±(dB)1.01.01.0 11G(Peak) ChannelChannel1Channel6Channel11 Target(dBm)14.013.013.0 Tolerance±(dB)1.01.01.0 11N20SISO(Peak) ChannelChannel1Channel6Channel11 Target(dBm) 13.012.014.0 Tolerance±(dB)1.01.01.0 11N40SISO(Peak) ChannelChannel3Channel6Channel9 Target(dBm) 11.011.011.0 Tolerance±(dB)1.01.01.0 Page 4 of 4 FCCID:2A57V-JC ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 8.MeasurementResults AsdeclaredbytheApplicant,theEUTisawirelessdeviceusedinafixapplication,atleast20cmfromany bodypartoftheuserornearbypersons;fromthemaximumEUTRFoutputpower,theminimumseparation distance,r=20cm,aswellasthegainoftheusedantennarefertoantennainformation,theRFpowerdensity canbeobtained. [Antenna] <2.4GWIFI> Band/Mode RFoutputpower AntennaGain (dBi) MPE (mW/cm2) MPE Limits (mW/cm2) dBmmW IEEE802.11b16.039.8107 0 0.00791.0000 IEEE802.11g15.031.6228 0 0.00631.0000 IEEE802.11nHT2014.025.1189 0 0.00501.0000 IEEE802.11nHT4012.015.8489 0 0.00321.0000 …
Text truncated - open the document above for the full version.
Page1of55FCCID:2A57V-JCReportNo.:LCS220322113AEA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity AppendixA RFTestDatafor2.4GWIFI(ConductedMeasurement) ProductName:LEDWALLLIGHT TestModel:JC-TX40-TYW-001 EnvironmentalConditions Temperature: 23.5  C RelativeHumidity:52.2% ATMPressure:100.0kPa TestEngineer: NickPeng Supervisedby: LiHuan Page2of55FCCID:2A57V-JCReportNo.:LCS220322113AEA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity B.16dBBandwidth ConditionModeFrequency(MHz)Antenna6dBBandwidth(MHz)Limit6dBBandwidth(MHz)Verdict NVNTb2412Ant19.8510.5Pass NVNTb2437Ant112.0110.5Pass NVNTb2462Ant111.0630.5Pass NVNTg2412Ant113.8020.5Pass NVNTg2437Ant116.0090.5Pass NVNTg2462Ant114.7710.5Pass NVNTn202412Ant114.0030.5Pass NVNTn202437Ant113.20.5Pass NVNTn202462Ant111.710.5Pass NVNTn402422Ant130.0680.5Pass NVNTn402437Ant127.6340.5Pass NVNTn402452Ant130.6310.5Pass Page3of55FCCID:2A57V-JCReportNo.:LCS220322113AEA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs 6dBBandwidthNVNTb2412MHzAnt1 6dBBandwidthNVNTb2437MHzAnt1 Page4of55FCCID:2A57V-JCReportNo.:LCS220322113AEA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 6dBBandwidthNVNTb2462MHzAnt1 6dBBandwidthNVNTg2412MHzAnt1 Page5of55FCCID:2A57V-JCReportNo.:LCS220322113AEA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 6dBBandwidthNVNTg2437MHzAnt1 6dBBandwidthNVNTg2462MHzAnt1 Page6of55FCCID:2A57V-JCReportNo.:LCS220322113AEA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 6dBBandwidthNVNTn202412MHzAnt1 6dBBandwidthNVNTn202437MHzAnt1 Page7of55FCCID:2A57V-JCReportNo.:LCS220322113AEA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 6dBBandwidthNVNTn202462MHzAnt1 6dBBandwidthNVNTn402422MHzAnt1 Page8of55FCCID:2A57V-JCReportNo.:LCS220322113AEA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 6dBBandwidthNVNTn402437MHzAnt1 6dBBandwidthNVNTn402452MHzAnt1 Page9of55FCCID:2A57V-JCReportNo.:LCS220322113AEA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity B.2MaximumConductedOutputPower ConditionModeFrequency(MHz)AntennaTotalPower(dBm)Limit(dBm)Verdict NVNTb2412Ant115.9630Pass NVNTb2437Ant115.8230Pass NVNTb2462Ant115.6130Pass NVNTg2412Ant114.1930Pass NVNTg2437Ant113.9330Pass NVNTg2462Ant113.8130Pass NVNTn202412Ant113.1730Pass NVNTn202437Ant112.7430Pass NVNTn202462Ant114.5730Pass NVNTn402422Ant111.830Pass NVNTn402437Ant111.4830Pass NVNTn402452Ant111.2830Pass Page10of55FCCID:2A57V-JCReportNo.:LCS220322113AEA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity B.3MaximumPowerSpectralDensityLevel ConditionModeFrequency (MHz) AntennaConductedPSD (dBm/3kHz) Duty Factor (dB) TotalPSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNTb2412Ant1-10.190-10.198Pass NVNTb2437Ant1-9.690-9.698Pass NVNTb2462Ant1-10.280-10.288Pass NVNTg2412Ant1-12.860-12.868Pass NVNTg2437Ant1-12.730-12.738Pass NVNTg2462Ant1-13.060-13.068Pass NVNTn202412Ant1-14.870-14.878Pass NVNTn202437Ant1-13.960-13.968Pass NVNTn202462Ant1-15.050-15.058Pass NVNTn402422Ant1-18.640-18.648Pass NVNTn402437Ant1-18.810-18.818Pass NVNTn402452Ant1-18.890-18.898Pass Page11of55FCCID:2A57V-JCReportNo.:LCS220322113AEA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs PSDNVNTb2412MHzAnt1 PSDNVNTb2437MHzAnt1 Page12of55FCCID:2A57V-JCReportNo.:LCS220322113AEA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity PSDNVNTb2462MHzAnt1 PSDNVNTg2412MHzAnt1 Page13of55FCCID:2A57V-JCReportNo.:LCS220322113AEA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|We…
Text truncated - open the document above for the full version.
Page1of37FCCID:2A57V-JCReportNo.:LCS220322113AEA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT For ShenzhenJichengPhotoelectricTechnologyCo.,Limited LEDWALLLIGHT TestModel:JC-TX40-TYW-001 Preparedfor:ShenzhenJichengPhotoelectricTechnologyCo.,Limited Address:6F,BuildingC,UnigreatIndustrialPark,No.10ofShihuanRoad, ShiyanTown,Shenzhen,China Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:March31,2022 Numberoftestedsamples:2 Samplenumber:220322113A-1,220322113A-2 Serialnumber:Prototype DateofTest:March31,2022~June16,2022 DateofReport:June21,2022 Page2of37FCCID:2A57V-JCReportNo.:LCS220322113AEA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FCCCFR47PART15C(15.247) ReportReferenceNo......................:LCS220322113AEA DateofIssue.......................................:June21,2022 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China TestingLocation/Procedure............:FullapplicationofHarmonisedstandards■PartialapplicationofHarmonisedstandards□ Otherstandardtestingmethod□ Applicant’sName.............................: ShenzhenJichengPhotoelectricTechnologyCo.,Limited Address................................................: 6F,BuildingC,UnigreatIndustrialPark,No.10ofShihuanRoad, ShiyanTown,Shenzhen,China TestSpecification Standard..............................................: FCCCFR47PART15C(15.247) TestReportFormNo......................:LCSEMC-1.0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceofthe material.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. EUTDescription...............................:LEDWALLLIGHT TradeMark..........................................:JICHENG TestModel...........................................:JC-TX40-TYW-001 Ratings.................................................:Input:AC100-265V,50/60Hz,26W Result...................................................:Positive Compiledby:Supervisedby:Approvedby: RoryHuang/AdministratorJinWang/TechniqueprincipalGavinLiang/Manager Page3of37FCCID:2A57V-JCReportNo.:LCS220322113AEA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCC--TESTREPORT EUT.........................................:LEDWALLLIGHT TestModel...............................:JC-TX40-TYW-001 Applicant...............................:ShenzhenJichengPhotoelectricTechnologyCo.,Limited Address..................................:6F,BuildingC,UnigreatIndustrialPark,No.10ofShihuanRoad, ShiyanTown,Shenzhen,China Telephone...............................:/ Fax..........................................:/ Manufacturer........................:ShenzhenJichengPhotoelectricTechnologyCo.,Limited Address...................................:6F,BuildingC,UnigreatIndustrialPark,No.10ofShihuanRoad, ShiyanTown,Shenzhen,China Telephone...............................: / Fax..........................................: / Factory...................................:ShenzhenJichengPhotoelectricTechnologyCo.,Limited Address...................................:6F,BuildingC,UnigreatIndustrialPark,No.10ofShihuanRoad, ShiyanTown,Shenzhen,China Telephone...............................:/ Fax..........................................:/ TestResultPositive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCS220322113AEA June21,2022 Dateofissue Page4of37FCCID:2A57V-JCReportNo.:LCS220322113AEA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000June21,2022InitialIssue-- Page5of37FCCID:2A57V-JCReportNo.:LCS220322113AEA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TABLEOFCONTENTS 1.GENERALINFORMATION........................................................................................................................6 1.1.DESCRIPTIONOFDEVICE(EUT).............................................................................................................6 1.2.HOSTSYSTEMCONFIGURATIONLISTANDDETAILS.................................................................................7 1.3.EXTERNALI/OCABLE...............…
Text truncated - open the document above for the full version.
Page1of2FCCID:2A57V-JC ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestSetupPhotosoftheEUT TestSetupPhoto(s)ofRadiatedEmissionsMeasurement Fig.1 Fig.2 Page2of2FCCID:2A57V-JC ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestSetupPhotoofLineConductedEmissionsMeasurement
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 39.81 mW |