2A5AD-4100938Hydraulic Levelling System

Alois Kober GmbH

Application Details

Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Date of Grant
Mar 12, 2024
Application Purpose
Original Equipment
Date of Application
Mar 12, 2024
Equipment Note
Hydraulic Levelling System
Frequency Range
902.00000000 - 915.00000000
Company
Alois Kober GmbH
Country
Germany

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗

ID Label/Location Info

↗
↗

Test Report

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Test Report

The test results relate only to the individual items which have been tested. This report shall not be reproduced in parts without the written approval of the testing laboratory © Copyright: All rights reserved by CETECOM Annex 1: Measurement diagrams to Test Report 21-1-0116002T02a-C1-A1 Number of pages: 5 Date of Report: 2022-Jan-06 Testing company: CETECOM GmbH Im Teelbruch 116 45219 Essen Germany Tel. + 49 (0) 20 54 / 95 19-0 Fax: + 49 (0) 20 54 / 95 19-150 Applicant: Alois Kober GmbH Test Object / Tested Device(s): E&P levelsystem E&P levelsystem Touchpanel FCC ID: 2A5AD-4100938 ISED ID: N/A Testing has been carried out in accordance with: Title 47 CFR, Chapter I FCC Regulations, Subchapter A Subpart B: §15.109 (Class B limits) ISED Regulations ICES-003, Issue 6 (Class B limits) Deviations, modifications or clarifications (if any) to above mentioned documents are written in each section under "Test method and limit". Test Report 21-1-0116002T02a-C1-A1 CETECOM_TR21-1-0116002T02a-C1-A1 2 / 5 1 Measurement diagrams 3.01_lying Common Information Test Description: Radiated field strength emission in 3m distance Test Site: CETECOM GmbH Essen Test Standard: FCC 15.109 Unintentional Radiator Antenna polarisation: horizontal/vertical Operating Mode: OP. Mode 1 Environmental Conditions:: Humidity : 50%rH; Temperature: 20°C Operator: JRi/PGrundmann/LKnopp Verdict: Passed EUT Information PMT number: 21-1-01160S04_C01 Manufacturer: ALOIS KOBER GMBH Final_Result Frequency (MHz) QuasiPeak (dBμV/m) Limit (dBμV/m) Margi n (dB) Meas. Time (ms) Bandwidt h (kHz) Heigh t (cm) Pol Azimut h (deg) Corr. (dB/m) 117.599000 34.21 43.50 9.29 1000.0 120.000 105.0 V 105.0 7.9 126.755000 34.65 43.50 8.85 1000.0 120.000 105.0 V 136.0 8.5 193.475000 39.16 43.50 4.34 1000.0 120.000 105.0 V 16.0 11.5 928.469000 39.61 46.00 6.39 1000.0 120.000 298.0 H 293.0 27.0 Level in dBμV/m Test Report 21-1-0116002T02a-C1-A1 CETECOM_TR21-1-0116002T02a-C1-A1 3 / 5 3.02_standing Common Information Test Description: Radiated field strength emission in 3m distance Test Site: CETECOM GmbH Essen Test Standard: FCC 15.109 Unintentional Radiator Antenna polarisation: horizontal/vertical Operating Mode: Environmental Conditions:: Humidity : 50%rH; Temperature: 20°C Operator: JRi/PGrundmann/LKnopp Verdict: Passed EUT Information PMT number: 21-1-01160S04_C01 Manufacturer: ALOIS KOBER GMBH Final_Result Frequency (MHz) QuasiPeak (dBμV/m) Limit (dBμV/m) Margi n (dB) Meas. Time (ms) Bandwidt h (kHz) Heigh t (cm) Pol Azimut h (deg) Corr. (dB/m) 72.535000 28.78 40.00 11.22 1000.0 120.000 111.0 V 256.0 6.6 96.745000 43.35 43.50 0.15 1000.0 120.000 105.0 V 276.0 8.2 126.785000 35.34 43.50 8.16 1000.0 120.000 109.0 V 100.0 8.5 175.165000 30.60 43.50 12.90 1000.0 120.000 109.0 V 62.0 10.4 193.505000 38.88 43.50 4.62 1000.0 120.000 105.0 V 22.0 11.5 928.405000 40.87 46.00 5.13 1000.0 120.000 115.0 H 278.0 27.0 Level in dBμV/m Test Report 21-1-0116002T02a-C1-A1 CETECOM_TR21-1-0116002T02a-C1-A1 4 / 5 4.01 Common Information Test Description: Radiated Filed Strength Emission Test Site Location: CETECOM GmbH Essen Test Site: Fully Anechoic Chamber (FAC1) - EMC32 V10.60.20 Test Standard: FCC Part 15.109, class B / RSS-Gen., Issue 4 Operating Mode: Op mode 1 Equipment Class: Class B Environmental Conditions:: Humidity : %rH; Temperature: °C Operator: HLa EUT Setup: 1 Verdict: Passed Comment: EUT Information PMT number: 21-1-01160S04_C01 Manufacturer: ALOIS KOBER GMBH Level in dBμV/m Test Report 21-1-0116002T02a-C1-A1 CETECOM_TR21-1-0116002T02a-C1-A1 5 / 5 4.02 Common Information Test Description: Radiated Filed Strength Emission Test Site Location: CETECOM GmbH Essen Test Site: Fully Anechoic Chamber (FAC1) - EMC32 V10.60.20 Test Standard: FCC Part 15.109, class B / RSS-Gen., Issue 4 Operating Mode: Op mode 1 Equipment Class: Class B Environmental Conditions:: Humidity : %rH; Temperature: °C Operator: HLa EUT Setup: 1 Verdict: Passed Comment: EUT Information PMT number: 21-1-01160S04_C01 Manufacturer: ALOIS KOBER GMBH End Of Annex 1

Contact Information

Applicant

Sebastian Weis
[email protected]+498221979191Fax: +498221978560

Test Firm

cetecom advanced GmbHGerald Schmidt
[email protected]+49 681 598 0Fax: +49 681 598 8775

Technical Specifications

#Rule PartsFrequency RangePower Output
115B902 MHz - 915 MHz-
Confidentiality
Long Term