Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Oct 10, 2023
Application Purpose
Original Equipment
Date of Application
Oct 10, 2023
Equipment Note
HHOLOVE Pet Water Fountain
Frequency Range
0.11030000 - 0.20500000
Company
HHO (Hangzhou) Digital Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

PET WATER FOUNTAIN User Manual <30dB Product introduction Package Main body x1User Manual x1 Drinking tray Filter unit Filter tray Wireless water pump Silicone pipe Bucket Wireless water pump x1 Filter unit x1 Installation and use Before installing, place the filter unit into water, soak and clean it thoroughly.(lt is recommended to soak in water twice, 5 minutes each time and rinse slightly) Soak the filter unit 1 Clean the tray set (drinking tray and filter tray) water storagebarrel and internal accessorieswith clean water before use.(it's recommended to clean twice) Rinse the tray set and bucket 2 Dry the outer surface of the bucket, place it on the charging base, and add clean water to the maximum water mark. Add water 3 1.Take out the silicone pipe and align it with the water pumpoutlet press it tightly. Be careful not to put it upside down. 2.Put the pump, filter tray, filter and drinking tray in proper order. Installation 4 Connect the USB power port to the power plug, and then plug it into a power socket to start. Connect the power supply 5 Maintainance and cleaning Detach the parts, and wash the surfaces of the drinking tray, filter tray, water pump, and bucket. The sponge on the water pump also needs to be taken out and cleaned. It is recommended to clean these components once a week. Specifications When used for the first time ,"black suspended particles" willappear on the water surface? This is the first time activated carbonhas been used.The presence ofactivated carbon components afterbeing dissolvedin wateris a normalphenomenon andis notaproduct quality issue.question! Please clean up the suspendedmatter on the surface. This phenomenon will disappear naturallyafter a few days ofcontinuous use What should I do if the water fountain stops spilling water? This is the first time activated carbonhas been used.The presence ofactivated carbon components afterbeing dissolvedin wateris a normalphenomenon andis notaproduct quality issue.question! Please clean up the suspendedmatter on the surface. This phenomenon will disappear naturallyafter a few days ofcontinuous use How often should the filter be replaced? The filter unit of this product is a consumable. and it is recommended to replace it once every 1-2 months. The filter unit mainly plays the role of filtering water quality impurities, softening water, and removing peculiar smell, so that pets can drink clean all the time. For the sake of your pets' health, please replace the filter frequently according to the use of the filter element. When used for the first time ,"black suspended particles" willappear on the water surface? We recommend cleaning the pet water dispenser and pump every week. Safety Precautions *Failure to comply with the following clauses may lead to that the product cannot be normally used or occurrence of other accidental losses.Please install and use device in strict accordance with the Manual. lt is NOT suggested to use this device for young pets under three months alone. Please use it indoors. Even if when this device is in low-voltage mode, it will still cause electricity leakage if the petchews the wire. Please guide your pets to use it correctly. Please use original USB power cord, or the device will be damaged to produce potentialsafety hazards. Place this device horizontally, and DO NOT overturn it, otherwise it will work abnormally or spill water. lt is prohibited to immerge or soak the bottom of the main machine of this product in water. lf the product is not used or is not moved for a long period of time, please unplug the power cord. lf child uses this device, please ensure that it is used under the guidance of adults. Please repair under the guidance of professionals to avoid various injuries. Be sure to check the remaining water in the Fountain before taking a minor vacation. In case of product use problems, please contact customer service timely. Fcc statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RF Exposure Information This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. Made by HHO Designed with LKK/Produced with PISEN Made in China Address: UNIT 3A-8,12/F KAISER CTR NO18 CENTRE ST,SAI YING PUN,HK [email protected] Email Contact: For FAQ and more help, please visit: https://www.hholove.com/support ©HHO Limited, all rights reserved. HHOLOVE and its logo are trademarks of HHO Limited, registered in the US, EU…

Text truncated - open the document above for the full version.

Attestation Statements

HHO (Hangzhou) Digital Technology Co., Ltd. Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 10/10/2023 U.S. Agent Designation HH O (Hangzhou) Digital Technology Co., Ltd. acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2A5DZ-CT-FTKSD): Name and company of U.S. agent: FCC US Agent, LLC Physical U.S. address of agent: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA FRN of U.S. agent: 0033402884 Email address of U.S. agent: [email protected] FCC US Agent, LLC acknowledges their obligation to accept service of process on behalf of HHO (Hangzhou) Digital Technology Co., Ltd.. HHO (Hangzhou) Digital Technology Co., Ltd. with the FRN 0032046344 accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Since rely, Signature Shouchuang Zhang project manager HHO (Hangzhou) Digital Technology Co., Ltd. Signature Tim Payne Manager FCC US Agent, LLC 48_[model] US_Agent_2.911(d)(7)-U, V05

Attestation Statements

Covered Equipment Identification Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows: We, applicant Company Name: HHO (Hangzhou) Digital Technology Co., Ltd. Address: Room 106-2, Building 1, No. 1818-2, Wenyi West Road, Yuhang Street, Yuhang District Hangzhou, Zhejiang, China Phone: +86-18688939429 certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2023-10-10 Signature Date Printed Name of Signee / Title: Shouchuang Zhang / Product Manager Company: HHO (Hangzhou) Digital Technology Co., Ltd. Address: Room 106-2, Building 1, No. 1818-2, Wenyi West Road, Yuhang Street, Yuhang District, Hangzhou, Zhejiang, China Phone: +86-18688939429 Fax: +86-18688939429 Email: [email protected]

Attestation Statements

Covered Equipment Attestation Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2A5DZ-CT-FTKSD CT-FTKSD We, applicant Company Name: HHO (Hangzhou) Digital Technology Co., Ltd. Address: Room 106-2, Building 1, No. 1818-2, Wenyi West Road, Yuhang Street, Yuhang District Hangzhou, Zhejiang, China Phone: +86-18688939429 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2023-10-10 Signature Date Printed Name of Signee / Title: Shouchuang Zhang / Product Manager Company: HHO (Hangzhou) Digital Technology Co., Ltd. Address: Room 106-2, Building 1, No. 1818-2, Wenyi West Road, Yuhang Street, Yuhang District, Hangzhou, Zhejiang, China Phone: +86-18688939429 Fax: +86-18688939429 Email: [email protected]

Cover Letter(s)

HHO (Hangzhou) Digital Technology Co., Ltd. Room 106-2, Building 1, No. 1818-2, Wenyi West Road, Yuhang Street, Yuhang District, Hangzhou, Zhejiang, China Date: October 10, 2023 FCC ID: 2A5DZ-CT-FTKSD Model Number: CT-FTKSD To: Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21048 To Whom It May Concern, We, HHO (Hangzhou) Digital Technology Co., Ltd. hereby declare that our product (HHOLOVE Pet Water Fountain) Model Number: CT-FTKSD meet item 5.2 of KDB 680106v03r01 as follow; Requirements of KDB 680106 D01 Yes / No Description Power transfer frequency is less than 1 MHz Yes The device operate in the frequency range is 110.3 KHz – 205 KHz Output power from each primary coil is less than or equal to 15 watts. Yes The device supports one primary coils, the maximum output power of the primary coil is 15W The system may consist of more than one source primary coils, charging one or more clients. If more than one primary coil is present, the coil pairs may be powered on at the same time. Yes Charging systems supports one primary coils and clients that are able to detect and allow coupling only between individual pairs of coils and the coils pairs power on at the same time. Client device is placed directly in contact with the transmitter. Yes Client device is placed directly in contact with the transmitter Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion). Yes Mobile exposure condition only The aggregate H-field strengths anywhere at or beyond 15 cm surrounding the device, and 20 cm away from the surface from all coils that by design can simultaneously transmit, and while those coils are simultaneously energized, are demonstrated to be less than 50% of the applicable MPE limit. Yes The EUT H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. HHO (Hangzhou) Digital Technology Co., Ltd. Room 106-2, Building 1, No. 1818-2, Wenyi West Road, Yuhang Street, Yuhang District, Hangzhou, Zhejiang, China Please contact me if you have any question. Sincerely, (Signed) Name/Title: Shouchuang Zhang/ Product Manager Company: HHO (Hangzhou) Digital Technology Co., Ltd. Address: Room 106-2, Building 1, No. 1818-2, Wenyi West Road, Yuhang Street, Yuhang District, Hangzhou, Zhejiang, China Tel: +86-18688939429 Fax: +86-18688939429 E-Mail: [email protected]

External Photos

Page1of5FCCID:2A5DZ-CT-FTKSD ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity EXTERIORPHOTOGRAPHS Fig.1 Fig.2 Page2of5FCCID:2A5DZ-CT-FTKSD ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of5FCCID:2A5DZ-CT-FTKSD ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of5FCCID:2A5DZ-CT-FTKSD ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8 Page5of5FCCID:2A5DZ-CT-FTKSD ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.9

ID Label/Location Info

Page1of1FCCID:2A5DZ-CT-FTKSD ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION (Size:L:6.0cmxW:6.0cm) LabelLocation HHOLOVEPetWaterFountain Model:CT-FTKSD FCCID:2A5DZ-CT-FTKSD

Internal Photos

Page1of3FCCID:2A5DZ-CT-FTKSD ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity INTERIORPHOTOGRAPHS Fig.1 Fig.2 Page2of3FCCID:2A5DZ-CT-FTKSD ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of3FCCID:2A5DZ-CT-FTKSD ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Coilantenna

RF Exposure Info

Page1of10FCCID:2A5DZ-CT-FTKSDReportNo.:LCSA09183177EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RFExposureEvaluationReport 1.ProductInformation FCCID:2A5DZ-CT-FTKSD ProductNameHHOLOVEPetWaterFountain ModelNumberCT-FTKSD PowerSupply Input:5V1A ForACAdapterModel:TEKA-UCA10US Input:100-240V~,50/60Hz,0.2AMax Output:5.0V1.0A ModulationTypeASK FrequencyRange110.3~205.0KHz AntennaTypeCoilAntenna Hardwareversion/ Softwareversion/ Accessories/ ExposurecategoryGeneralpopulation/uncontrolledenvironment EUTTypeProductionUnit DeviceTypeMobileDevice 2.EvaluationMethod PerKDB680106D01Section3.RFExposureRequirements; 1)ConsumerwirelesspowertransferdevicesapprovedunderPart18in somecaseshavetodemonstratecompliancewithRFexposurerequirements.Thepotentialfor exposuremustbeassessedaccordingtotheoperatingconfigurationsofthewirelesssystem andtheexposureconditionsofusersandbystanders.RFexposuremustbeevaluatedwiththe clientdevice(s)beingchargedbytheprimaryatmaximumoutputpower.TheRFexposure requirementsmustbedeterminedinconjunctionwiththedeviceoperatingcharacteristics, accordingtothemobileandportableexposurerequirementsinSection2.1091andSection 2.1093oftherules.SARandMPElimitsdonotcoverthefrequencyrangeforwirelesspower transferapplicationswhichoperatebelow100kHzand300kHzrespectively;therefore,RF exposurecomplianceneedstobedeterminedwithrespectto1.1307(c)and(d)oftheFCC rules. 2)Basedonthedesignandimplementationofthepowertransfer application,itmustbeclearlyidentifiedifmobileorportableRFexposureconditionsapply. Devicesthatareinstalledtoprovideseparationofatleast20cmfromusersandbystanders mayqualifyformobileexposureconditions.Forsomeconditionswhereusersandbystanders maybeexposedatcloserthan20cm,section2.1091(d)(4)oftherulesmayapply. 3)Fordevicesdesignedfortypicaldesktopapplications,suchawireless chargingpads,RFexposureevaluationshouldbeconductedassumingauserseparation distanceof15cm.EandHfieldstrengthmeasurementsornumericalmodelingmaybeusedto demonstratecompliance.Measurementsshouldbemadefromallsidesandthetopofthe primary/clientpair,withthe15cmmeasuredfromthecenteroftheprobe(s)totheedgeofthe device.Emissionsbetween100kHzto300kHzshouldbeassessedversusthelimitsat300 kHzinTable1ofSection1.1310:614V/mand1.63A/m.AKDBinquiryisrequiredtodetermine Page2of10FCCID:2A5DZ-CT-FTKSDReportNo.:LCSA09183177EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity theapplicableexposurelimitsbelow100kHz. 4)Portableexposureconditionsfrom100kHzto6GHzaredetermined withrespecttoSARrequirements.ExistingSARsystemsandtestproceduresaregenerally intendedformeasurementsabove100MHz.Whilenumericalmodelingcanbeanalternative, theconstraintsofsubstantialcomputationalresourcesatlowfrequenciescouldintroduce furtherlimitations.Underthesecircumstances,includingoperationsbelow100kHz,the Commissionmayconsideracombinationofanalyticalanalysis,fieldstrength,radiatedand conductedpowermeasurements,inconjunctionwithsomelimitednumericalmodelingto assesscompliance. 5)Dependingontheoperatingfrequency,existingSARandMPE measurementproceduresmaybeadaptedtoevaluatewirelesspowertransferdevicesfor compliancewithrespecttomobileorportableexposureconditions.Ifthegranteeoritstestlab haveanyquestionsregardingRFexposureevaluationtheyshouldcontacttheFCCLaboratory withsufficientsystemoperatingconfigurationdetailstodetermineifRFexposureevaluationis necessaryand,ifrequired,howtoapplyspecifictestprocedures.Below100MHz,whenSAR testingisrequiredandthedeviceisoperatingatcloseproximitytopersons,informationon devicedesign,implementation,operatingconfigurations,exposureconditionsofusersand bystandersareneededtodeterminetheevaluationandtestingrequirements.Inaddition,the influenceofnearbyobjectsmayalsoneedconsiderationaccordingtothewirelesspower transfersystemimplementation;forexample,theeffectsofplacingthedevice,itscoilsor radiatingelementsonornearmetallicsurfaces 3.EvaluationLimit 3.1Referevaluationmethod ANSIC95.1–1999:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoRadio FrequencyElectromagneticFields,3kHzto300GHz. FCCKDBpublication680106D01RFExposureWirelessChargingAppsv03:RFExposure ConsiderationsforLowPowerConsumerWirelessPowerTransferApplications FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1091:Radiofrequencyradiationexposureevaluation:mobiledevices FCCCFR47part18.107:Indusial,Scientific,andMedicalEquipment Page3of10FCCID:2A5DZ-CT-FTKSDReportNo.:LCSA09183177EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 3.2Limit LimitsforMaximumPermissibleExposure(MPE)/ControlledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3-3.06141.63*1006 3.0-301842/f4.89/f*900/f 2 6 30-30061.40.1631.06 300-1,500//f/3006 1,500-100,000//56 LimitsforMaximumPermissibleExposure(MPE)/UncontrolledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforGeneralPopulation/UncontrolledExposure 0.3-1.346141.63*10030 1.34-30824/f2.19/f*180/f 2 30 30-30027.50.0730.230 300-1,500//f/150030 1,500-100,000//1.030 F=frequencyinMHz *=Plane-waveequivalentpowerdensity AccordingtoFCCKDB680106D01Section3.RFExposureRequirementsclause3the Emission-Limitsinthefrequencyrangefrom100KHzto300KHzshouldbeassessedversus thelimitsat300KHzinTable1ofCFR47–Section1.310asfollowing(measureddistan…

Text truncated - open the document above for the full version.

Test Report

广州市睿晶晶研新材料科技有限公司 地址( Add ) : 广州市花都区狮岭镇芙蓉大道 88 号 电话( Tel ) : 020 - 81000895 1. 传真( Fax ) : 020 - 81000896 产品规格承认书 SPECIFICATON APPROVAL 客户名称: CUSTOMER 客户品名: Product Name ofCustomer 43双槽发射模组 我方产品名(材质): Product Mame ofOurs(Matenial) 43双槽发射模组 承 认: APPROVED 核准: 制表: 日期: APPROVED DRAWN 吕沈娟 DATE 2023.9.20 Guangzhou Ruijingjingyan New Material Technology Co., Ltd. 88 Furong Average,Shiling Town, Huadou Disctrit, Guangzhou, China All measurements were performed radiated and therefore additional antenna gain documentation is not required. , Specifications Reference Designs Version1.0.0 part 2 of 5 产品型号: Model Number 客户料号: Customer P / N A11双槽发射摸组 供应商料号: Supplier P / N 20.5*37-6.5Uh-8TS 一,外观与尺寸(Appearance Size):(单位/mm) A 5.0±0.1 B 20±1 C 36±2 D 43±0.5 E 2.5±1 F 15±3 G 1.8 H 0.8 J K L M N O P Q R S T U V W X Y Z Specifications Reference Designs Version1.0.0 part 3 of 5 二,原理图(Schematic Diagram): 三,绕线参数(Winding Parameters): 绕组 Winding 开始 Start 结束 Finish 圈数 Turns 线径 Line Diameter 绕线方式 Winding Way 绕线方向 Winding Direction 层数&圈数 Layer&Circle S F 8TS 0.07*100P 密绕 逆时针反 贴 1层/8TS 四,电气特性(Electrical Characteristics): 项目 Item 端子 Terminal 测试条件 Test Conditions 测试仪器 Test Instrument 参数 Parameter 单位 Unit 数值 Numerical Value 电感 S-F 100KHz/ 1.00V/100Ω 1062电桥 Inductance@1 00KHz/1V μH 6.5μH±10% Q值 S-F 100KHz/ 1.00V/100Ω 1062电桥 Q@100KHz/1V 75MIN 电阻 S-F 100KHz/ 1.00V/100Ω 1062电桥 DCR@100KHz/ 1V mΩ 55MAX Materiel Bill Of Materials Version1.0.0 part 4 of 5 材料清单 Material List 客户料号: Customer P / N 制造商料号: Supplier P / N 序号 No. 材料名称 Material Name 材料规格 Material Specification 材料代号 Material Code 制作商 Manufacturer 1 丝包线 0.07*100P 2 无铅锡条 高温 3 高温胶带 8mm 4 胶水 白胶 5 白色普通双面胶(0.07皇 冠油胶) 厚度0.07MM皇冠油胶- 外径42.5MM内孔7MM 6 带槽磁片 43*0.8 7 珍珠棉 8 纸箱 9 10 11 承认人员 Approver 校对人员 Proofreader 制图员 Cartographer 日期 Date 余昌政 2022.8.22 Encasement Package Criterion 样品检测报告 客户名称 Customer 客户料号 Customer P/N 样品数量 Total Of Sample 检测数量 Quantity Of Test 检测日期 Date Of Testing 检测事项 Inspection Items 项次 No. 项目/规格 Item/Specifications 1 2 3 4 5 测量仪器 Measuring Instrument 判定 Judge 1 外径 B 2 内径 B 3 磁片外径 B 4 厚度 B 5 引线 B 6 焊锡 B 7 电感 H 8 电阻 H 9 Q值 H 测量仪器: A.目视 B.游标卡尺 C.分离卡 D.高度规 E.角度规 F.投影机 G.标准针规 H.电桥 外观检查 Visual Inspection 外观检查无异常 检测人员 Testing Personnel 审核人员 Auditor

Test Report

Page 1 of 26 FCCID:2A5DZ-CT-FTKSDReportNo.:LCSA09183177EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT For HHO(Hangzhou)DigitalTechnologyCo.,Ltd. HHOLOVEPetWaterFountain TestModel:CT-FTKSD Preparedfor:HHO(Hangzhou)DigitalTechnologyCo.,Ltd. Address:Room106-2,Building1,No.1818-2,WenyiWestRoad, YuhangStreet,YuhangDistrict,HangzhouCity,Zhejiang Province,China Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address: 101,201BldgA&301BldgC,JujiIndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:September19,2023 Numberoftestedsamples:2 Serialnumber:A09183177-1,A09183177-2 DateofTest:September19,2023~September28,2023 DateofReport:September28,2023 Page 2 of 26 FCCID:2A5DZ-CT-FTKSDReportNo.:LCSA09183177EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FCCCFR47PART15C ReportReferenceNo......................:LCSA09183177EA DateOfIssue......................................:September28,2023 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................: 101,201BldgA&301BldgC,JujiIndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China TestingLocation/Procedure............:FullapplicationofHarmonisedstandards■ PartialapplicationofHarmonisedstandards□ Otherstandardtestingmethod□ Applicant’sName.............................:HHO(Hangzhou)DigitalTechnologyCo.,Ltd. Address................................................: Room106-2,Building1,No.1818-2,WenyiWestRoad,Yuhang Street,YuhangDistrict,HangzhouCity,ZhejiangProvince,China TestSpecification Standard..............................................:FCCCFR47PART15C TestReportFormNo.........................:LCSEMC-1.0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceof thematerial.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialdueto itsplacementandcontext. TestItemDescription.....................:HHOLOVEPetWaterFountain TradeMark..........................................:HHOLOVE TestModel...........................................:CT-FTKSD PowerSupply......................................: Input:5V1A ForACAdapterModel:TEKA-UCA10US Input:100-240V~,50/60Hz,0.2AMax Output:5.0V1.0A Result..................................................:Positive Compiledby:Supervisedby:Approvedby: LiHuan/AdministratorCaryLuo/TechniqueprincipalGavinLiang/Manager Page 3 of 26 FCCID:2A5DZ-CT-FTKSDReportNo.:LCSA09183177EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT TestResultPositive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetest laboratory. TestReportNo.:LCSA09183177EA September28,2023 Dateofissue TestModel..........................:CT-FTKSD EUT....................................:HHOLOVEPetWaterFountain Applicant...........................:HHO(Hangzhou)DigitalTechnologyCo.,Ltd. Address..............................: Room106-2,Building1,No.1818-2,WenyiWestRoad, YuhangStreet,YuhangDistrict,HangzhouCity,Zhejiang Province,China Telephone..........................:/ Fax.....................................:/ Manufacturer.....................:HHO(Hangzhou)DigitalTechnologyCo.,Ltd. Address..............................: Room106-2,Building1,No.1818-2,WenyiWestRoad, YuhangStreet,YuhangDistrict,HangzhouCity,Zhejiang Province,China Telephone..........................:/ Fax.....................................:/ Factory..............................:HeyuanPeituTechnologyCo.,Ltd. Address..............................: Room9014,ServiceCenter,ButterflyRidgeIndustrial Park,XiantangTown,DongyuanCounty,HeyuanCity, China Telephone..........................:/ Fax.....................................:/ Page 4 of 26 FCCID:2A5DZ-CT-FTKSDReportNo.:LCSA09183177EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000September28,2023InitialIssue--- Page 5 of 26 FCCID:2A5DZ-CT-FTKSDReportNo.:LCSA09183177EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TABLEOFCONTENTS 1.GENERALINFORMATION ................................................................................................................. 6 1.1DescriptionofDevice(EUT)........................................................................................................................6 1.2SupportequipmentList .............................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Page1of2FCCID:2A5DZ-CT-FTKSD ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Shouchuang Zhang
[email protected]18688939429Fax: 18688939429

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.1103 MHz - 0.205 MHz-
Confidentiality
Long Term

Other Applications from HHO (Hangzhou) Digital Technology Co., Ltd.

HHOLOVE Yuno AI Automatic Feeder - FCC ID 2A5DZ-CT-CMWYN - HHO (Hangzhou) Digital Technology Co., Ltd.
2A5DZ-CT-CMWYN

HHOLOVE Yuno AI Automatic Feeder

Apr 10, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Automatic Cat Litter Box Pro - FCC ID 2A5DZ-CL-TYW - HHO (Hangzhou) Digital Technology Co., Ltd.
2A5DZ-CL-TYW

Automatic Cat Litter Box Pro

Jul 31, 2024

Equipment Class

DTS - Digital Transmission System
HHOGene Gpods - FCC ID 2A5DZ-GLA001 - HHO (Hangzhou) Digital Technology Co., Ltd.
2A5DZ-GLA001

HHOGene Gpods

Aug 25, 2022

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter