
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Shenzhen Kerun E-commerce Co., Ltd Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 [December 19, 2025] U.S. Agent Designation [Shenzhen Kerun E-commerce Co., Ltd] acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought FCC ID: 2A5FW-PX3 Name and company of U.S. agent: [GLOCERTS TECHNOLOGY INC] Physical U.S. address of agent: [19784 SUNKISSED RIDGE DR, RIVERSIDE, CA 92507] FRN of U.S. agent: [0036339737] Email address of U.S. agent: [[email protected]] Telephone of U.S.agent: (626) 588-8039 [GLOCERTS TECHNOLOGY INC] acknowledges their obligation to accept service of process on behalf of [Shenzhen Kerun E-commerce Co., Ltd]. [Shenzhen Kerun E-commerce Co., Ltd] with the FRN [0032051864] accepts its obligation to maintain an agent for service of process in the United States for no less than 1 year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. Sincerely, Signature Signature [Shirley long] [Huiying Fan] [Manager] [Director] [Shenzhen Kerun E-commerce Co., Ltd] [GLOCERTS TECHNOLOGY INC]
Shenzhen Kerun E-commerce Co., Ltd (December 19, 2025) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for FCC ID: 2A5FW-PX3 [Shenzhen Kerun E-commerce Co., Ltd] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, the equipment does not utilize cyber-security or anti-virus software from Kaspersky Lab, Inc, or any of its successors and assignees, which is also on the “covered list”. Sincerely, (Applicant signature) (Applicant printed name) Shirley long Shenzhen Kerun E-commerce Co., Ltd (December 19, 2025) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for FCC ID: 2A5FW-PX3 [Shenzhen Kerun E-commerce Co., Ltd] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) Shirley long
Shenzhen Kerun E-commerce Co., Ltd Model Difference Data:December 19, 2025 Product description: Digital Camera Model name: PX3, OX3 Trade Name: N/A FCC ID: 2A5FW-PX3 All the model are the same circuit and RF module, only the model names are different. Regards Sincerely Client’s signature : Client’s name / title : Shirley long(Manager) Contact information / address:Room 813, Building A, Hongshengyuan Information Industry Park, No. 339, Bulong Road, Ma'antang Community, Bantian Street, Shenzhen City
Shenzhen Kerun E-commerce Co., Ltd (December 19, 2025) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (Digital Camera / PX3, OX3 / FCC ID: 2A5FW-PX3) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☒ Internal Photos ☐ NOTE 1 ☒ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No required to be submitted with this application be permanently withheld from public review. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely, Signature: Name: Shirley long Title: Manager
Shenzhen Kerun E-commerce Co., Ltd (December 19, 2025) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize (Shenzhen CTB Testing Technology Co., Ltd.) to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Signature: Name: Shirley long Title: Manager
Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 4 Model: PX3 External Photos Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 4 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 3 of 4 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 4 of 4
FCC ID LABEL: Label Location: FCC ID: 2A5FW-PX3 Model No.: PX3
Shenzhen CTB Testing Co., Ltd. FCC ID:2A5FW-PX3 Portable device According to §15.247(e)(i) and §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to KDB447498 D01 General RF Exposure Guidance V06 The 1-g SAR and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]·[√f(GHZ)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f(GHZ) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. 2.4GWIFI: Modulation Channel Freq. (GHz) Conduct ed power (dBm) Conducte d power (mW) Tune-up power (dBm) Max tune-up power (dBm) Max tune-up power (mW) Distance (mm) Result calculatio n SAR Exclusion threshold SAR test exclusion 2.412 8.053 6.39 8±1 9.00 7.94 <5 2.46728 3.00 YES 2.437 8.215 6.63 8±1 9.00 7.94 <5 2.48003 3.00 YES 2.462 8.939 7.83 8±1 9.00 7.94 <5 2.49272 3.00 YES 2.412 8.052 6.39 8±1 9.00 7.94 <5 2.46728 3.00 YES 2.437 8.393 6.91 8±1 9.00 7.94 <5 2.48003 3.00 YES 2.462 8.338 6.82 8±1 9.00 7.94 <5 2.49272 3.00 YES 2.412 8.428 6.96 8±1 9.00 7.94 <5 2.46728 3.00 YES 2.437 8.447 6.99 8±1 9.00 7.94 <5 2.48003 3.00 YES 2.462 8.081 6.43 8±1 9.00 7.94 <5 2.49272 3.00 YES 802.11b 802.11g 802.11n( HT20) Conclusion: For the max result : 2.49272≤ FCC Limit 3.0 for 1g SAR.
深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址: 深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 承认书 SPECIFICATIONFORAPPROVAL 审批/Approval客户批准/CustomerApproval 制作 PreparedBy 审核 CheckedBy 批准 ApprovalBy 审核 CheckedBy 批准 ApprovalBy 签章 Signature 黄宗宝夏承磊陈华明 日期 Date 2024.11.042024.11.042024.11.04 修订履历/ChangeLog 版本 Version 修订内容 ChangeDescription 责任人 PersoninCharge 核准 ApprovalBy 日期 Date 客户名称 CustomerName 晨芯 客户项目名Customer ProjectName K1-CX 顺达成项目名 SDCProjectName K1-CX 客户编码 CustomerP/N 顺达成料号 SDCP/N WF5931B-0813R-40 频段 Band WIFI2.4G 版本号 Version A1 设计人信息/DesignerInformation 射频工程师 RFEngineer 伍文载 研发主管 R&DDiretor 夏承磊 结构工程师 MEEngineer 黄宗宝 深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址: 深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 目录/Catalogue 序号 No. 项目 Item 页码 PageNo. 1 图纸或实物图片 DrawingorProductImage 3 2 尺寸测量报告 DimensionsTestReport 4 3 射频性能测试报告 RFPerformanceTestReport 5-8 4 可靠性测试报告 ReliabilityTestReport1 9 5 包装文件 PackageDocument 10 6 环境有害物质管控一览表 RoHSControllistforSample 11 7 安装事宜或其它 InstallWizard orOther 11 深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址: 深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 产品图纸或实物图片 DrawingorProductImage 李 瑶 娜 W F 5 9 3 1 B - 0 8 1 3 R - 4 0 K 1 - C X X . X ± 0 . 5 X . X X ± 0 . 2 X X X . ± 1 0 . 0 X X . ± 5 . 0 X . ± 2 . 0 1 4 0 1 注 : 6 0 m m 以 内 的 线 材 , 若 无 客 户 要 求 则 默 认 端 子 头 朝 下 手 撕 位 S D C K 1 W F 深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址: 深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 样品尺寸测量报告 SampleDimensionsTestReport 测试日期 TestDate 2024.11.04 样品数量 SampleQty. 3 测试人 Inspector 许燕芳 尺寸编号 DimensionNo. 标准 Standard 样品1 Sample1 样品2 Sample2 样品3 Sample3 Pass/NG ①长度35±0.2mm3535.135 Pass ②宽度5±0.2mm55.15 Pass ③厚度0.1±0.03mm0.10.10.1 Pass ④线长40±2mm404140 Pass 最终结论 Conclusion PASS 测试人&日期 Inspector&Date 许燕芳2024.11.04 批准&日期 Approval&Date 深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址: 深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 射频性能测量报告 RFPerformanceTestReport 天线测试设备简介 AntennaTestEquipmentIntroduction 测试天线输入特性使用AgilentE5071CandAgilent5062A矢量网络分析仪;辐射特性利用 广屏三维近场暗室进行测试,并分别使用8960E5515和AgilentE4438C进行了分析。暗房的测试坐 标如下: TestofantennainputcharacteristicsusingAgilentE5071CandAgilent5062Avectornetwork analyzer;Theradiationpatternoftheantennaaretestedusingtheguangping3DnearfieldAnechoicChamber, andtheinstrumentisusedtoagilent8960E5515andAgilentE4438C.Thetestcoordinatesofthedarkroomare asfollows: 1.S11参数测量/S11Parameter-VSWR 使用一根50Ω同轴电缆连接到天线,然后该电缆连接到网络分析仪测量S11参数,被测量产品远离金属至少 20厘米。 MeasuringMethodisa50 Ω coaxialcableisconnectedtotheantenna.Thenthiscableisconnectedtoanetworkanalyzerto measuretheS11parameter,Keepingthisfixtureawayfrommetalatleast20cm. 深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址: 深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 S11Parameter-VSWR 2.天线匹配网络/ AntennaMatchingNetwork 深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址: 深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 3.Gain&Efficiency 深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址: 深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 可靠性测试报告 ReliabilityTestReport 测试日期 TestDate 2024.11.04 样品数量 SampleQty. 3 测试人 Inspector 许燕芳 测试项目 TestItem 要求 Requirement 试验设备 testing equipment 样品1 Sample1 样品2 Sample2 样品3 Sample3 判定 PASS/NG 高温存储 在+85°C条件下暴露 24H,恢复2H后进行测 试 恒温恒湿箱OKOKOKPass 低温存储 在-40°C条件下暴露 24H,恢复2H后进行测 试 恒温恒湿箱OKOKOKPass 高温工作 在+60°C条件下通电工 作24H 恒温恒湿箱OKOKOKPass 低温工作 在-20°C条件下通电工 作24H 恒温恒湿箱OKOKOKPass 盐雾试验 (5士0.5)%氯化钠、 pH值为6.5~7.2,实验 箱温度(35±2)°C □24H☑48H 盐雾试验机OKOKOKPass 连接器铆压拉 拔力 1.13线径≥10N 0.81线径≥8N RG174≥60N RG178≥50N 推拉力计≥10N≥10N≥10NPass 最终结论 Conclusion Pass 测试人&日 期 Inspector& Date 许燕芳2024.11.04 批准&日期 Approval&D ate 深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址: 深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址: 深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 安装事宜或其它 InstallWizardorOther 安装过程: 取1PCS产品,用手撕下FPC背面的离型纸,然后将FPC定位孔位置与外壳定位孔位置(定位筋 位或定位线)对齐,平整的贴附与外壳上,具体位置如下图所示: 安装过程注意事项: □粘贴天线后保证FPC完整贴附于外壳; □定位孔与外壳定位柱位置对齐; □FPC边缘与外壳边缘对齐; □带端子天线在将端子扣合到主板PCBA端时请首先对齐端子,然后垂直扣合; □拆卸天线端子时需使用工具(如专用撬棍)垂直翘起端子,不可直接拽线拆卸。 深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址: 深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 产品ROHS证书
TEST REPORT Compiled by: Reviewed by: Approved by: Kai Chen Martin Feng Bin Mei / Director Note: If there is any objection to the inspection results in this report, please submit a written report to the company within 15 days from the date of receiving the report. The test report is effective only with both signature and specialized stamp. This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen CTB Testing Technology Co., Ltd. this report can’t be reproduced except in full. The tested sample(s) and the sample information are provided by the client. “*” indicates the testing items were fulfilled by subcontracted lab. “#” indicates the items are not in CNAS accreditation scope. Test item description: Digital Camera FCC ID: 2A5FW-PX3 Trademark(s): N/A Model/Type reference: PX3 , OX3 Applicant’s name: Shenzhen Kerun E-commerce Co., Ltd Address: Room 813, Building A, Hongshengyuan Information Industry Park, No. 339, Bulong Road, Ma'antang Community, Bantian Street, Shenzhen City Manufacturer: Shenzhen Kerun E-commerce Co., Ltd Address: Room 813, Building A, Hongshengyuan Information Industry Park, No. 339, Bulong Road, Ma'antang Community, Bantian Street, Shenzhen City Prepared By: Shenzhen CTB Testing Technology Co., Ltd. Address: 1&2/F., Building A, No.26, Xinhe Road, Xinqiao, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, China Sample Received Date: Nov. 04, 2025 Sample tested Date: Nov. 04, 2025 to Dec. 08, 2025 Issue Date: Dec. 08, 2025 Report No.: CTB25112613401RF01 Test Standards FCC CFR Title 47 Part 15 Subpart C Section 15.247 ANSI C63.10:2020 Test Results PASS Remark: This is WIFI-2.4GHz band radio test report. Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB25112613401RF01 Report Tel: 4008-707- 283 Web: http://www.ctb-lab.net Page 2 of 52 TABLE OF CONTENT Test Report Declaration Page 1. VERSION ........................................................................................................................................ 3 2. TEST SUMMARY ........................................................................................................................... 4 3. MEASUREMENT UNCERTAINTY ................................................................................................. 5 4. PRODUCT INFORMATION AND TEST SETUP ............................................................................ 6 4.1 Product Information .......................................................................................................................... 6 4.2 Test Setup Configuration .................................................................................................................. 6 4.3 Support Equipment........................................................................................................................... 6 4.4 Channel List ..................................................................................................................................... 6 4.5 Test Mode ........................................................................................................................................ 7 4.6 Test Environment ............................................................................................................................. 7 5. TEST FACILITY AND TEST INSTRUMENT USED ....................................................................... 8 5.1 Test Facility ...................................................................................................................................... 8 5.2 Test Instrument Used ....................................................................................................................... 8 6. AC POWER LINE CONDUCTED EMISSION ................................................................................ 11 6.1 Block Diagram Of Test Setup ......................................................................................................... 11 6.2 Limit ................................................................................................................................................ 11 6.3 Test procedure ............................................................................................................................... 11 6.4 Test Result ..................................................................................................................................... 13 7. RADIATED SPURIOUS EMISSION ............................................................................................. 15 7.1 Block Diagram Of Test Setup ......................................................................................................... 15 7.2 Limit ................................................................................................................................................ 15 7.3 Test procedure ............................................................................................................................... 16 7.4 Test Result ..................................................................................................................................... 17 8. BAND EDGE AND RF COUNDUCTED SPURIOUS EMISSIONS ............................................... 34 8.1 Block Diagram Of Test Setup ......................................................................................................... 34 8.2 Limit ................................................................................................................................................ 34 8.3 Test procedure ............................................................................................................................... 34 8.4 Tes t Result ..................................................................................................................................... 35 9. COUDUCTED OUTPUT POWER ..............................................................................…
Text truncated - open the document above for the full version.
Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 2 Model: PX3 Radiated Emission Below 1G Above 1G Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 2 Conducted emissions RF Conducted
19784 SUNKISSED RIDGE DR, · RIVERSIDE,, California, 92507 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 7.83 mW |

Digital Camera
Equipment Class
DTS - Digital Transmission SystemDigital Camera
Equipment Class
DTS - Digital Transmission System
Digital Video Camera
Equipment Class
DTS - Digital Transmission System