FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Ningbo XiaoE Electronic Technology Co., LTD/
  3. 2A5FX-BS60

2A5FX-BS60Under desk charging station

Ningbo XiaoE Electronic Technology Co., LTD
Under desk charging station - FCC ID 2A5FX-BS60 - Ningbo XiaoE Electronic Technology Co., LTD
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Jul 01, 2024
Application Purpose
Original Equipment
Date of Application
Jun 30, 2024
Equipment Note
Under desk charging station
Frequency Range
0.11500000 - 0.20500000
Company
Ningbo XiaoE Electronic Technology Co., LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Under desk charging station This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. FCC RF exposure statement: The equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance between 20cm the radiator your body. 7. FCC Warning 7

Attestation Statements

OasisCompliance,Inc.FCCID: 2A5FX-BS60 CFR47§2.911(d)(7)FCCUSAgentLetterofAttestation Date:05-20-2024 FCCID:2A5FX-BS60FRN:0032051880 To:FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 ToWhomItMayConcern, ThisletteristoconfirmthatwehaveacceptedtheresponsibilitytoactasUSAgentonbehalf ofNingboXiaoEElectronicTechnologyCo.,LTD(“theapplicant”)fortheabovereferenced FCCID. Weareawareoftherequirementsandresponsibilitiesoftheapplicant’sagentforserviceof processasoutlinedintheFCCsection2.911(d)(7)andReportandOrderFCC22-84paragraph 63. U.S.AgentInformation: OasisCompliance,Inc. FRN:0033464157 JamesHe 3313VerdiDr,SanJose,CA95111 Cell:2026028330 Sincerelyyours, JamesHe GlobalMarketAccessManager OasisCompliance,Inc. Email:[email protected]

Attestation Statements

C5266091_X24_Ed.2 1/1 “Attestation Statements” TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 The Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List 1 , which is periodically updated. See the Covered List for more details. This Attestation Statement is to confirm that we follow the Section 2.911(d)(5)(i)-(ii) Applicant Company name: Ningbo XiaoE Electronic Technology Co., LTD FRN: 0032051880 Grantee code: 2A5FX FCC ID: 2A5FX-BS60 Contact Name: Jason Xu Address: 3rd Floor, Building A2-1, East District, New Materials Innovation Center, High-tech Zone, Ningbo City, Zhejiang Province, China. Telephone No: 13957872276 Fax No: Email: [email protected] i. [Ningbo XiaoE Electronic Technology Co., LTD] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. The applicant must sign this certification. ii. [ Ningbo XiaoE Electronic Technology Co., LTD] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not (as a specifically named entity or any of its subsidiaries or affiliates) identified on the Covered List as an entity producing “covered” equipment. The applicant must sign this certification. Ningbo XiaoE Electronic Technology Co., LTD certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Date: 05.23.2024 Applicant’s Name: Jason Xu Title: General Manager Signature 1 The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist

Attestation Statements

CFR47§2.911(d)(7)AgentDesignationAttestation Date:05-20-2024 FCCID:2A5FX-BS60FRN:0032051880 To:FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 NingboXiaoEElectronicTechnologyCo.,LTD(“theapplicant”)asrequiredbysection 2.911(d)(7),designatesthefollowingagent,locatedintheUnitedStates,forpurposesofacting astheapplicant’sagentforserviceofprocess. Theapplicantacknowledgesthattheywillmaintainanagentfornolessthanoneyearafterthe granteehasterminatedallmarketingandimportationortheconclusionofanyCommission- relatedproceedinginvolvingtheequipment.Theapplicantfurtheracknowledgestheir responsibilitytoinformtheFCCwhenevertheagentinformationchanges. U.S.AgentInformation: JamesHe OasisCompliance,Inc. 3313VerdiDr,SanJose,CA95111 [email protected] cell:2026028330 Sincerelyyours, _________________________________ JasonXu Manager NingboXiaoEElectronicTechnologyCo.,LTD Address:3rdFloor,BuildingA2-1,EastDistrict,NewMaterialsInnovationCenter,High-tech Zone,NingboCity,ZhejiangProvince,China. Email:[email protected] Phone:+8613957872276

Attestation Statements

Ningbo XiaoE Electronic Technology Co., LTD Product Similarity Declaration Product name: Under desk charging station Model name: BS60, BS18, BS60-B FCC ID: 2A5FX-BS60 We (Ningbo XiaoE Electronic Technology Co., LTD) hereby state that all the models are electrical identical including the same software parameter and hardware design (i.e., circuit design, PCB Layout, RF module/circuit, antenna type(s) and antenna location, components on PCB, etc.,), same mechanical structure and design (including product enclosure, materials, etc.,), the only difference is the model name. Signature: Name: Jason Xu Title: General Manager Date: 05.23.2024

Cover Letter(s)

C5266091_X8_Ed.1 1/1 Letter of Authorization Company: Ningbo XiaoE Electronic Technology Co., LTD Address: 3rd Floor, Building A2-1, East District, New Materials Innovation Center, High-tech Zone, Ningbo City, Zhejiang Province, China. Product Name: Under desk charging station Model Number: BS60, BS18, BS60-B FCC Identifier: 2A5FX-BS60 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Jason Xu Date: 5/23/2024 Title: General Manager Signature of applicant:

Cover Letter(s)

C5266091_X10_Ed.2 1/1 Ningbo XiaoE Electronic Technology Co., LTD Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 5/23/2024 Subject: Request for Confidentiality FCC ID: 2A5FX-BS60 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☐ Internal Photos ☐ NOTE 1 ☐ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of ______ days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name: Jason Xu Title: General Manager

External Photos

Page 1 of 5 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Photographs of the EUT (External Photos) Model: BS60 Page 2 of 5 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 3 of 5 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 4 of 5 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 5 of 5 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected]

ID Label/Location Info

Label Location

Internal Photos

Page 1 of 9 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Photographs of the EUT (Internal Photos) Model: BS60 Page 2 of 9 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 3 of 9 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 4 of 9 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] ANT Page 5 of 9 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 6 of 9 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 7 of 9 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 8 of 9 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 9 of 9 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] ----End of Report----

RF Exposure Info

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Test Report Report No.: MTi240223020-05E2 Date of issue: 2024-03-27 Applicant: Ningbo XiaoE Electronic Technology Co., Ltd Product: Under desk charging station Model(s): BS60, BS18, BS60-B FCC ID: 2A5FX-BS60 Shenzhen Microtest Co., Ltd. http://www.mtitest.com Page 2 of 13 Report No.: MTi240223020-05E2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Instructions 1. This test report shall not be partially reproduced without the written consent of the laboratory. 2. The test results in this test report are only responsible for the samples submitted 3. This test report is invalid without the seal and signature of the laboratory. 4. This test report is invalid if transferred, altered, or tampered with in any form without authorization. 5. Any objection to this test report shall be submitted to the laboratory within 15 days from the date of receipt of the report. Page 3 of 13 Report No.: MTi240223020-05E2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Contents 1 General Description ........................................................................................................................ 5 1.1 Description of the EUT ....................................................................................................................................... 5 1.2 Description of test modes ................................................................................................................................... 5 1.3 Description of support units ................................................................................................................................ 6 2 Measurement uncertainty ............................................................................................................... 6 3 Test facilities and accreditations .................................................................................................... 7 3.1 Test laboratory .................................................................................................................................................... 7 4 List of test equipment ..................................................................................................................... 8 5 Test result ........................................................................................................................................ 9 5.2 Test setup ......................................................................................................................................................... 10 5.3 Test Procedures ................................................................................................................................................ 10 5.4 Equipment Approval Considerations ................................................................................................................ 11 5.5 Test results ....................................................................................................................................................... 12 Photographs of the Test Setup ............................................................................................................ 13 Photographs of the EUT....................................................................................................................... 13 Page 4 of 13 Report No.: MTi240223020-05E2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Test Result Certification Applicant: Ningbo XiaoE Electronic Technology Co., Ltd Address: 3rd Floor, Building A2-1, East District, New Materials Innovation Center, High-tech Zone, Ningbo City, Zhejiang Province, China. Manufacturer: Ningbo XiaoE Electronic Technology Co., Ltd Address: 3rd Floor, Building A2-1, East District, New Materials Innovation Center, High-tech Zone, Ningbo City, Zhejiang Province, China. Product description Product name: Under desk charging station Trademark: Xiaoe Model name: BS60 Series Model: BS18, BS60-B Standards: FCC CFR 47 PART 1, § 1.1310 FCC CFR 47 PART 2, § 2.1091 Test method: KDB 680106 D01 Wireless Power Transfer v04 Date of Test Date of test: 2024-03-08 to 2024-03-27 Test result: Pass Test Engineer : (Letter Lan) Reviewed By: : (Leon Chen) Approved By: : (Tom Xue) Page 5 of 13 Report No.: MTi240223020-05E2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] 1 General Description 1.1 Description of the EUT Product name: Under desk charging station Model name: BS60 Series Model(s): BS18, BS60-B Model difference: All the models are the same circuit and module, except the model name. Electrical rating: Type-C Input: 5Vdc 3A USB-A Output: 5Vdc 3A, 9Vdc 2A, 12Vdc 1.5A Type-C Output: 5Vdc 3A, 9Vdc 3A, 12Vdc 3A, 15Vdc 3A, 20Vdc 3A Wireless Output: 5W/10W/15W Battery: 3.7Vdc 20000mAh Hardware version: N/A Software version: PC-708 Test sample(s) number: 9995 RF specification Operating frequency range: 115-205KHz Modulation type: ASK Antenna(s) type: Coil Antenna 1.2 Description of test modes All the test modes were carried out with the EUT in normal operation, the final test mode of the…

Text truncated - open the document above for the full version.

Test Report

The test report is only used for customer scientific research, teaching, internal quality control and other purposes, and is for internal reference only. Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Test Report Report No.: MTi240223020-05E1 Date of issue: 2024-03-27 Applicant: Ningbo XiaoE Electronic Technology Co., Ltd Product: Under desk charging station Model(s): BS60, BS18, BS60-B FCC ID: 2A5FX-BS60 Shenzhen Microtest Co., Ltd. http://www.mtitest.com Page 2 of 21 Report No.: MTi240223020-05E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Instructions 1. This test report shall not be partially reproduced without the written consent of the laboratory. 2. The test results in this test report are only responsible for the samples submitted 3. This test report is invalid without the seal and signature of the laboratory. 4. This test report is invalid if transferred, altered, or tampered with in any form without authorization. 5. Any objection to this test report shall be submitted to the laboratory within 15 days from the date of receipt of the report. Page 3 of 21 Report No.: MTi240223020-05E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Table of contents 1 General Description ......................................................................................................................... 5 1.1 Description of the EUT ............................................................................................................................... 5 1.2 Description of test modes .......................................................................................................................... 5 1.3 Environmental Conditions .......................................................................................................................... 6 1.4 Description of support units ....................................................................................................................... 6 1.5 Measurement uncertainty .......................................................................................................................... 6 2 Summary of Test Result .................................................................................................................. 7 3 Test Facilities and accreditations ................................................................................................... 8 3.1 Test laboratory ........................................................................................................................................... 8 4 List of test equipment ...................................................................................................................... 9 5 Evaluation Results (Evaluation) .................................................................................................... 10 5.1 Antenna requirement ............................................................................................................................... 10 6 Radio Spectrum Matter Test Results (RF) .................................................................................... 11 6.1 20dB Occupied Bandwidth ...................................................................................................................... 11 6.2 Emissions in frequency bands (below 30MHz)........................................................................................ 14 6.3 Emissions in frequency bands (30MHz - 1GHz)...................................................................................... 17 Photographs of the test setup ............................................................................................................. 20 Photographs of the EUT....................................................................................................................... 21 Page 4 of 21 Report No.: MTi240223020-05E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Test Result Certification Applicant: Ningbo XiaoE Electronic Technology Co., Ltd Address: 3rd Floor, Building A2-1, East District, New Materials Innovation Center, High-tech Zone, Ningbo City, Zhejiang Province, China. Manufacturer: Ningbo XiaoE Electronic Technology Co., Ltd Address: 3rd Floor, Building A2-1, East District, New Materials Innovation Center, High-tech Zone, Ningbo City, Zhejiang Province, China. Product description Product name: Under desk charging station Trademark: Xiaoe Model name: BS60 Series Model(s): BS18, BS60-B Standards: 47 CFR Part 15C Test Method: ANSI C63.10-2020 Date of Test Date of test: 2024-03-08 to 2024-03-27 Test result: Pass Test Engineer : (Letter Lan) Reviewed By : (Leon Chen) Approved By : (Tom Xue) Page 5 of 21 Report No.: MTi240223020-05E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] 1 General Description 1.1 Description of the EUT Product name: Under desk charging station Model name: BS60 Series Model(s): BS18, BS60-B Model difference: All the models are the same circuit and module, except the model name. Electrical rating: Type-C Input: 5Vdc 3A USB-A Output: 5Vdc 3A, 9Vdc 2A, 12Vdc 1.5A Type-C Output: 5Vdc…

Text truncated - open the document above for the full version.

Test Report

LTHPage1of4 承認書 SPECIFICATIONFORAPPROVAL 客戶: CUSTOMER: WeiE 客戶料號: CUSTP/N: 音泽料號: FINEP/N: G43.5*0.5-13.8-0.08*105P-12T-6.8UH-W39.3-L180MM+ BJ 産品型號: DESC: Φ 43.5MMX0.8MM 日期: DATE: 2023/10/27 版本: Version: A.0 擬制 PREPAREDBY 審核 CHECKEDBY 批准 APPROVEDBY 客戶承認 CUSTOMERAPPROVE 黄小定 东莞市来特好科技有限公司 DongguanLaiTeHaoTechnologyCo.,LTD Factoryaddress:Room301,Building9,No.2,DongshanIndustrialStreet,ZhangluoTown,Dongguan, Guangdong,China LTHPage2of4 版本變更履歷 VersionChangeHistory 版本 Rev. 變更前 BeforeChange 變更後 AfterChange 更改日期 ChangeDate 批准 ApprovedBy A.0 新发行 ----2023.10.27 LTHPage3of4 SPECIFICATION 産品型號: DESC G43.5*0.8-13.8-0.08*105P-12 T*6.8UH-W39.3-L180MM+BJ 版本 Rev:A.0 客戶CUST: 微鹅 客户料号CUSTP/N: 一、尺寸DIMENSION:(mm) 二、原理图SCHEMATICDIAGRAM: A 43.5±0.5 B 39.3±0.5 C 13.8±0.5 D 180 ±2 E 3±2 F 5.3±0.2 G H I K 注: 1.交叉出线; 2.线圈贴43.5双槽磁片,磁 片尺寸43.5 ± 0.5mm,,厚度 为0.8±0.05mm. 3.磁片背面贴背胶 三、绕线参数WindingSpecification: 序号 NO. 端子 TERMINAL 线径 WIRE 圈数 Turns 绕线方向 WindingDirection 1SF丝包线0.08*105P12TsCCW 四、电气特性ELECTRICALCHARACTERISTICS: 温度TEMPERATURE:25±10°C,湿度RELATIVEHUMIDITY:65±20% 序号 NO. 项目 ITEM 端子 TERMINAL 标准 SPECIFICATION 测试条件 TESTFREQUENCY 测试仪器 TESTEQUIPMENTS 1IND.S-F 3.8u H±10%单独线圈100KHz/1.0VLCZMETER1062B 2IND.S-F6.8H±10%加磁片100KHz/1.0VLCZMETER1062B 3DCRS-F≤55mΩLCZMETER502B LTHPage4of4 擬制 / 日期 PREPAREDBY/DATE 審核 / 日期 CHECKEDBY/DATE 黄小定2023.10.27

Test Setup Photos

Page 1 of 2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel : (8 6-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Photographs of the test setup Model: BS60 Emissions in frequency bands (below 30MHz) Emissions in frequency bands (30MHz - 1GHz) Page 2 of 2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel : (8 6-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] MPE

Contact Information

Applicant

Jason Xu(General Manager)
[email protected]13957872276Fax: 13957872276

Technical Contact

Shenzhen Microtest Co., LtdLeon Chen
[email protected]+86-755 88850135

Shenzhen · China

Test Firm

Shenzhen Microtest Co., Ltd.Phoebe Cui
[email protected]0755 88850135 1393

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.115 MHz - 0.205 MHz-
Confidentiality
Long Term
Grant Notes
The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons. End-users must be provided with operating procedures for satisfying RF exposure compliance.