2A5Q7-XG100Thermal imaging camera

Wuhan Xinguan Instrument Co.,Ltd
Thermal imaging camera - FCC ID 2A5Q7-XG100 - Wuhan Xinguan Instrument Co.,Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 10, 2022
Application Purpose
Original Equipment
Date of Application
Apr 10, 2022
Equipment Note
Thermal imaging camera
Frequency Range
2412.00000000 - 2462.00000000
Company
Wuhan Xinguan Instrument Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

UserManualofDPseriesHandheldThermalImagingCamera UserManualofDPseries HandheldThermalImaging Camera V2.2 UserManualofDPseriesHandheldThermalImagingCamera ©2021AllrightsreservedShenzhenDianyangTechnologyCo.,Ltd. UserManualofDPseriesHandheldThermal ImagingCamera Version number DateModifiedAuthorApprovedByNote V1.0202001New V2.0202008Updatesomespecification V2.1202103Addhumanbodytemperaturefeature V2.2202202Modify ©2021ShenzhenDianYangTechnology.Allrightsreserved. 2021CopyrightShenzhenDianyangTechnologyCo.,Ltd.Allrightsreserved. CopyrightNotice: ThecopyrightofthisdocumentisownedbyShenzhenDianyangTechnologyCo.,Ltd.The articlereferstotheproprietaryinformationofShenzhenDianyangTechnologyCo.,Ltd.,and nounitorindividualmayuseordisclosethedocumentandanypictures,forms,dataand otherinformationcontainedinthedocumentwithoutthewrittenpermissionofShenzhen DianyangTechnologyCo.,Ltd. Theinformationinthisdocumentwillbecontinuouslyupdatedwiththeadvancementof productsandtechnologyofShenzhenDianyangTechnologyCo.,Ltd.,andShenzhen DianyangTechnologyCo.,Ltd.willnotnotifytheupdateofsuchinformation. UserManualofDPseriesHandheldThermalImagingCamera ©2021AllrightsreservedShenzhenDianyangTechnologyCo.,Ltd. Contents OVERVIEW ......................................................................................................................................... 1 1.1APPEARANCE .......................................................................................................................... 1 1.2POWERON/OFF ..................................................................................................................... 4 1.3QUICKMEASUREMENT ............................................................................................................. 4 1.4SAVE,DELETEANDVIEWINFRAREDTHERMALIMAGE .................................................................... 9 1.5MAINPAGE ......................................................................................................................... 13 1.6CONTROLANDTRIGGERKEYS .................................................................................................. 13 1.7CHARGEANDEXPORTPICTURES .............................................................................................. 14 1.7.1Charge ................................................................................................................ 14 1.7.2ExportPicture .................................................................................................... 14 OPERATIONANDSETTINGS ............................................................................................................ 15 2.1MAINPAGEOPERATION ........................................................................................................ 15 2.1.1QuickOperation ................................................................................................. 15 2.1.1.1QuickSwitchColorPalettes ........................................................... 15 2.1.1.2QuicklySwitchImageModes ......................................................... 15 2.1.2FirstLevelMenu ................................................................................................. 16 2.1.3SecondLevelMenu ............................................................................................ 17 2.1.3.1Measurement ................................................................................. 18 2.1.3.2ImageMode ................................................................................... 19 2.1.3.3ThermalAGC .................................................................................. 20 2.1.3.4ColorPalette ................................................................................... 20 2.2SETTINGS ............................................................................................................................. 21 2.2.1Language ............................................................................................................ 21 2.2.2Emissivity ............................................................................................................ 23 2.2.3Temperaturealarm ............................................................................................ 23 2.2.3.1Alarmabovethreshold ................................................................... 24 UserManualofDPseriesHandheldThermalImagingCamera ©2021AllrightsreservedShenzhenDianyangTechnologyCo.,Ltd. 2.2.3.2Alarmbelowthreshold ................................................................... 25 2.2.4WiFi .................................................................................................................... 25 2.2.4.1EnableandDisableWiFi ................................................................. 25 2.2.4.2WiFiConfiguration ......................................................................... 25 2.2.5LED ..................................................................................................................... 26 2.2.6More ................................................................................................................... 26 2.2.6.1TemperatureUnit .......................................................................... 27 2.2.6.2Storage ........................................................................................... 27 2.2.6.3Date ................................................................................................ 28 2.2.6.4AutomaticPowerOff ..................................................................... 29 2.2.7TemperatureBar ................................................................................................ 29 2.2.8Brightness .......................................................................................................... 30 2.2.9Restorefactorysettings ..................................................................................... 30 2.2.10humanbodytemperaturemeasurement ..................................…

Text truncated - open the document above for the full version.

External Photos

FCCID:2A5Q7-XG100

ID Label/Location Info

LabelLocationOnEUT Label ProductName:Thermalimagingcamera ModelNo.:XG100 FCCID:2A5Q7-XG100 ThisdevicecomplieswithPart15oftheFCCRules.Operationis subjecttothefollowingtwoconditions: (1)Thisdevicemaynotcauseharmfulinterference,and (2)Thisdevicemustacceptanyinterferencereceived,including interferencethatmaycauseundesiredoperation.

Internal Photos

FCCID:2A5Q7-XG100 ANT

Operational Description

version01 WuhanXinguanInstrumentCo.,Ltd DeclarationconcerningAntennaSpecification Itisherebydeclaredthattheproduct ModelNo.:Thermalimagingcamera FCCID:2A5Q7-XG100 fulfillstherequirementinFCCtestrelatingtotheantennatype. ThedevicespecifiedaboveconfirmstotheFCCrecommendationsfor internal antennatype(s) describedbelow: ModelNo.ofantenna:N/A Typeofantenna:Monopoleantenna Gainoftheantenna:1dBi Frequencyrange:2412-2462MHz Themountingoftheantennaisfixedtotheradiomoduleandnootherantennashouldbeused. Companyname:WuhanXinguanInstrumentCo.,Ltd Address:B2-2621,Wandaplaza,hanyangdongfengroadNo.236 City:Wuhan ZIP/Postalcode:/ Country:China Place:WuhanDate:4/1/2022 Signature:

RF Exposure Info

RFEXPOSUREEVALUATION FCCID:2A5Q7-XG100 AccordingtoFCC1.1310:Thecriterialistedinthefollowingtableshallbeused toevaluatetheenvironmentimpactofhumanexposuretoradiofrequency(RF) Radiationasspecifiedin§1.1307(b): RoutineSARevaluationreferstothatspecificallyrequiredby§2.1093,using measurementsorcomputersimulation.WhenroutineSARevaluationisnot required,portabletransmitterswithoutputpowergreaterthantheapplicable lowthresholdrequireSARevaluationtoqualifyforTCBapproval. Channel (MHz) Maximum output power (dBm) Tuneup tolerance (dBm) MaxTuneUp Power(dBm) Distance (mm) Calculation results Limit Operating Mode 24129.529.52 ±1 10.52053.5017.5 802.11b24379.429.42±110.42053.4397.5 24629.39.3±110.30053.3637.5 24129.119.11 ±1 10.11053.1867.5 802.11g24379.479.47±110.47053.4797.5 24629.539.53±110.53053.5457.5 24129.249.24 ±1 10.24053.2837.5 802.11n (HT20) 24379.569.56±110.56053.5527.5 24629.039.03±110.03053.1607.5 24228.418.41 ±1 9.41052.7177.5 802.11n (HT40) 24378.338.33±19.33052.6767.5 24528.128.12±19.12052.5577.5 Result:NoStandaloneSARtestisrequired.

Test Report

Page1of46 AppendixTestData ReportNo.:18220WC20048601TestSampleNo.:1-2-2 StartTestDate:2022.3.22FinishTestDate:2022.3.23 TestEngineer:Auditor: Temperature:24.3 °C RelativeHumidity:56% Pressure:1012hPa AppendixA:DTSBandwidth TestResult TestModeAntennaChannel DTSBW [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict 11BAnt1 24129.1602407.4402416.600≥0.5PASS 24379.6002432.4402442.040≥0.5PASS 24629.1602457.4002466.560≥0.5PASS 11GAnt1 241216.4802403.8002420.280≥0.5PASS 243716.3602428.8402445.200≥0.5PASS 246216.4802453.7602470.240≥0.5PASS 11N20Ant1 241217.4002403.4402420.840≥0.5PASS 243717.6402428.2002445.840≥0.5PASS 246217.6802453.1602470.840≥0.5PASS 11N40Ant1 242235.8202404.4202440.240≥0.5PASS 243735.5802419.3602454.940≥0.5PASS 245236.0602434.1802470.240≥0.5PASS Page2of46 TestGraphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 Page3of46 11G_Ant1_2412 11G_Ant1_2437 Page4of46 11G_Ant1_2462 11N20_Ant1_2412 11N20_Ant1_2437 Page5of46 11N20_Ant1_2462 11N40_Ant1_2422 Page6of46 11N40_Ant1_2437 11N40_Ant1_2452 Page7of46 AppendixB:OccupiedChannelBandwidth TestResult TestModeAntennaChannel OCB[MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict 11BAnt1 241212.3082405.9542418.262---PASS 243712.2612430.9092443.170---PASS 246212.3022455.8662468.168---PASS 11GAnt1 241217.1552403.4792420.634---PASS 243717.0702428.4842445.554---PASS 246217.0782453.4782470.556---PASS 11N20Ant1 241217.9452403.0902421.035---PASS 243717.9342428.0672446.001---PASS 246217.9702453.0392471.009---PASS 11N40Ant1 242236.1682404.0782440.246---PASS 243736.0742419.0612455.135---PASS 245236.1532433.9452470.098---PASS Page8of46 TestGraphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 Page9of46 11G_Ant1_2412 11G_Ant1_2437 Page10of46 11G_Ant1_2462 11N20_Ant1_2412 11N20_Ant1_2437 Page11of46 11N20_Ant1_2462 11N40_Ant1_2422 Page12of46 11N40_Ant1_2437 11N40_Ant1_2452 Page13of46 AppendixC:Maximumconductedoutputpower TestResult TestModeAntennaChannelResult[dBm]Limit[dBm]Verdict 11BAnt1 24129.52≤30PASS 24379.42≤30PASS 24629.30≤30PASS 11GAnt1 24129.11≤30PASS 24379.47≤30PASS 24629.53≤30PASS 11N20Ant1 24129.24≤30PASS 24379.56≤30PASS 24629.03≤30PASS 11N40Ant1 24228.41≤30PASS 24378.33≤30PASS 24528.12≤30PASS Page14of46 AppendixD:Maximumpowerspectraldensity TestResult TestModeAntennaChannelResult[dBm/3kHz]Limit[dBm/3kHz]Verdict 11BAnt1 2412-10.02≤8PASS 2437-10.39≤8PASS 2462-6.64≤8PASS 11GAnt1 2412-15.48≤8PASS 2437-15.71≤8PASS 2462-15.64≤8PASS 11N20Ant1 2412-15.88≤8PASS 2437-15.72≤8PASS 2462-15.79≤8PASS 11N40Ant1 2422-17.65≤8PASS 2437-18.12≤8PASS 2452-18.65≤8PASS Page15of46 TestGraphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 Page16of46 11G_Ant1_2412 11G_Ant1_2437 Page17of46 11G_Ant1_2462 11N20_Ant1_2412 11N20_Ant1_2437 Page18of46 11N20_Ant1_2462 11N40_Ant1_2422 Page19of46 11N40_Ant1_2437 11N40_Ant1_2452 Page20of46 AppendixE:Bandedgemeasurements TestResult TestModeAntennaChNameChannelRefLevel[dBm]Result[dBm]Limit[dBm]Verdict 11BAnt1 Low24122.78-51.31≤-17.22PASS High24623.42-55.79≤-16.58PASS 11GAnt1 Low2412-1.87-45.11≤-21.87PASS High2462-1.88-51.53≤-21.88PASS 11N20Ant1 Low2412-2.56-45.67≤-22.56PASS High2462-1.23-50.18≤-21.23PASS 11N40Ant1 Low2422-3.88-45.23≤-23.88PASS High2452-4.66-47.85≤-24.66PASS Page21of46 TestGraphs 11B_Ant1_Low_2412 11B_Ant1_High_2462 11G_Ant1_Low_2412 Page22of46 11G_Ant1_High_2462 11N20_Ant1_Low_2412 Page23of46 11N20_Ant1_High_2462 11N40_Ant1_Low_2422 11N40_Ant1_High_2452 Page24of46 Page25of46 AppendixF:ConductedSpuriousEmission TestResult TestModeAntennaChannel FreqRange [Mhz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict 11BAnt1 2412 Reference2.712.71---PASS 30~10002.71-70.41≤-17.29PASS 1000~265002.71-55.27≤-17.29PASS 2437 Reference2.982.98---PASS 30~10002.98-69.93≤-17.02PASS 1000~265002.98-55.47≤-17.02PASS 2462 Reference3.263.26---PASS 30~10003.26-69.84≤-16.74PASS 1000~265003.26-54.37≤-16.74PASS 11GAnt1 2412 Reference-1.92-1.92---PASS 30~1000-1.92-69.86≤-21.92PASS 1000~26500-1.92-55.89≤-21.92PASS 2437 Reference-2.22-2.22---PASS 30~1000-2.22-70.11≤-22.22PASS 1000~26500-2.22-55.79≤-22.22PASS 2462 Reference-2.27-2.27---PASS 30~1000-2.27-70.32≤-22.27PASS 1000~26500-2.27-43.08≤-22.27PASS 11N20Ant1 2412 Reference-1.95-1.95---PASS 30~1000-1.95-71.09≤-21.95PASS 1000~26500-1.95-55.74≤-21.95PASS 2437 Reference-2.02-2.02---PASS 30~1000-2.02-69.3≤-22.02PASS 1000~26500-2.02-54.77≤-22.02PASS 2462 Reference-1.28-1.28---PASS 30~1000-1.28-69.54≤-21.28PASS 1000~26500-1.28-55.09≤-21.28PASS 11N40Ant1 2422 Reference-3.69-3.69---PASS 30~1000-3.69-70.21≤-23.69PASS 1000~26500-3.69-55.26≤-23.69PASS 2437 Reference-4.25-4.25---PASS 30~1000-4.25-69.58≤-24.25PASS 1000~26500-4.25-54.71≤-24.25PASS 2452 Reference-4.45-4.45---PASS 30~1000-4.45-66.26≤-24.45PASS 1000~26500-4.45-55.06≤-24.45PASS Page26of46 TestGraphs 11B_Ant1_2412_0~Reference 11B_Ant1_2412_30~1000 11B_Ant1_2412_1000~26500 Page27of46 11B_Ant1_2437_0~Reference 11B_Ant1_2437_30~1000 Page28of46 11B_Ant1_2437_1000~26500 11B_Ant1_2462_0~Reference 11B_Ant1_2462_30~1000 Page29of46 11B_Ant1_2462_1000~26500 11G_Ant1_2412_0~Reference Page30of46 11G_Ant1_2412_30~1000 11G_Ant1_2412_1000~26500 11G_Ant1_2437_0~Reference Page31of46 11G_Ant1_2437_30~1000 11G_Ant1_2437_1000~26500 Page32of46 11G_Ant1_2462_0~Reference 11G_Ant1_2462_30~1000 11G_Ant1_2462_1000~26500 Page33of46 11N20_Ant1_2412_0~Reference 11N20_Ant1_2412_30~1000 Page34of46 11N20_Ant1_2412_1000~26500 11N20_Ant1_2437_0~Reference 11N20_Ant1_2437_30~1000 Page35of46 11N20_Ant1_2437_1000~26500 11N20_Ant1_2462_0~Reference Page36of46 11N20_Ant1_2462_30~1000 11N20_Ant1_2462_1000~26500 11N40_Ant1_2422_0~Reference Page37of46 11N40_Ant1_2422_30~1000 11N40_Ant1_2422_1000~26500 Page38of46 11N40_Ant1_2437_0~Reference 11N40_Ant1_2437_30~1000 11N40_Ant1_2437_1000~26500 Page39of46 11N40_Ant1_2452_0~Reference 11N40_Ant1_2452_30~1000 Page40of46 11N40_Ant1_2452_1000~26500 Page41of46 AppendixG:DutyCycle TestResult TestModeAntennaChannel Transmission Duration[ms] Transmission Period[ms] Duty Cycle[%] LimitVerdict 11BAnt1 24128.398.4299.64---PASS 24378.398.4199.76---PASS 24628.398.4199.76---PASS 11GAnt1 24121.391.4…

Text truncated - open the document above for the full version.

Test Report

ReportNo.:18220WC20048601FCCID:2A5Q7-XG100Page1of51 Code:AB-RF-05-a FCCTESTREPORT ClientName:WuhanXinguanInstrumentCo.,Ltd Address: B2-2621,Wandaplaza,hanyangdongfengroadNo.236, Wuhan,Hubei,China ProductName:Thermalimagingcamera Date:Apr.08,2022 ShenzhenAnbotekComplianceLaboratoryLimited ReportNo.:18220WC20048601FCCID:2A5Q7-XG100Page2of51 Code:AB-RF-05-a Contents 1.GeneralInformation ............................................................................................................................................... 5 1.1.ClientInformation ....................................................................................................................................... 5 1.2.DescriptionofDevice(EUT) ..................................................................................................................... 5 1.3.AuxiliaryEquipmentUsedDuringTest ................................................................................................... 6 1.4.DescriptionofTestModes ........................................................................................................................ 6 1.5.Listofchannels ........................................................................................................................................... 7 1.6.DescriptionOfTestSetup ......................................................................................................................... 8 1.7.TestEquipmentList .................................................................................................................................... 9 1.8.MeasurementUncertainty ....................................................................................................................... 10 1.9.DescriptionofTestFacility ...................................................................................................................... 10 2.SummaryofTestResults ................................................................................................................................... 11 3.ConductedEmissionTest ................................................................................................................................... 12 3.1.TestStandardandLimit .......................................................................................................................... 12 3.2.TestSetup .................................................................................................................................................. 12 3.3.TestProcedure .......................................................................................................................................... 12 4.RadiationSpuriousEmissionandBandEdge ................................................................................................ 15 4.1.TestStandardandLimit .......................................................................................................................... 15 4.2.TestSetup .................................................................................................................................................. 15 4.3.TestProcedure .......................................................................................................................................... 16 4.4.TestData .................................................................................................................................................... 17 5.MaximumOutputPowerTest ............................................................................................................................ 27 5.1.TestStandardandLimit .......................................................................................................................... 27 5.2.TestSetup .................................................................................................................................................. 27 5.3.TestProcedure .......................................................................................................................................... 27 5.4.TestData .................................................................................................................................................... 27 6.6DBOccupyBandwidthTest ............................................................................................................................. 28 6.1.TestStandardandLimit .......................................................................................................................... 28 6.2.TestSetup .................................................................................................................................................. 28 6.3.TestProcedure .......................................................................................................................................... 28 6.4.TestData .................................................................................................................................................... 28 7.PowerSpectralDensityTest .............................................................................................................................. 29 7.1.TestStandardandLimit .......................................................................................................................... 29 7.2.TestSetup .................................................................................................................................................. 29 7.3.TestProcedure .......................................................................................................................................... 29 7.4.TestData .................................................................................................................................................... 29 8.100kHzBandwidthofFrequencyBandEdgeRequirement ......................................................................... 30 8.1.TestStandardan…

Text truncated - open the document above for the full version.

Test Setup Photos

FCCID:2A5Q7-XG100 PhotoofPowerLineConductedEmissionTest PhotoofRadiationEmissionTest

Contact Information

Applicant

Eddie Lu(Sales Manager)
[email protected]15971411257Fax: N.A

Test Firm

Shenzhen Anbotek Compliance Laboratory LimitedJeff Zhu
[email protected]86-755-26064492Fax: 86-755-26014772

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz9.10 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted. This device supports 20 and 40MHz bandwidth operation.