Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
User Manual Smart Pet Door Please read and fully understand this manual before use. Functional diagram: 1. The cat door has four access control modes, namely, no entry and no exit, only entry and no exit, only exit and no entry, and entry and exit. 2.Select one of the access control modes through the function key M(Mode Key)on the panel.Press the M key once, the access control mode is switched once,the sound will ring once, the indicator light corresponding to the access control mode will be on, and the light will go out automatically after 2 seconds.The mode selection is completed; the access control will be automatically locked within 15 seconds after no operation;When the cat with the induction key approaches the cat door, the access control will switch to the setting mode,and the indicator light corresponding to the access control mode will be on for 2 seconds and then go out.When the cat pushes the door in and out, the access control will automatically lock after 3 seconds.Or if the cat does not enter the door and leaves for 15 seconds,the rear door is forbidden to lock automatically(no in, no out mode). Select one of the access control modes by pressing the button on the remote controller.There are four access control modes available on the remote controller panel.Press the remote controller once.Once the access control mode is switched,the sound will ring once, the corresponding indicator light will be on,the light will automatically go out after 2 seconds,and the mode selection is completed;Without any operation,the rear door will be locked automatically in 15 seconds,and the remote control distance of the remote control is 10M at unobstructed. 3.RF key: a) Turn the RF key to ON to enable the induction key function; b) Turn the RF key to OFF to disable the induction key function; The RF key, whether on or off, has 4 access control modes to choose from. 4.Factory status of the product: the key is not coded, and the remote controller is not coded. Subsequent replacement of the battery will save the last record status. 1) When there is no key code, all the initial induction keys are identified to be able to open the door, and there is no limit on the number of keys; lf only the key with matching code can open the door after matching code, it can support the identification of 4 keys with matching code at most. 2) When the remote controller has no code, the remote controller cannot be used; it can be used after the code is checked, and only one remote controller is supported. 5. How to use the matching code. 1) Short press the function M button to switch the access control mode, and the indicator light will be on at the corresponding position for 2 seconds and then go out. 2) Induction key code matching: long press the M button for 3 seconds, the sound will ring for 3 times, and the indicator light will display circularly to enter the code matching mode.If the induction key is within 10MM of the induction area and the sound is heard once and the indicator light is off,the code matching is successful.If there is no operaton in the code matching mode for 30 seconds,it will automatically exit the code matching mode,or press the M button for a long time again to hear the sound and exit the code matching mode.If there are more than one sensing key,repeat the above actions. 3) Code matching of remote controller: long press the M button for 3 seconds,the sound will ring for 3 times, and the indicator light will display circularly,then the code matching mode will be entered.Aim the remote controller at the cat door, and press two keys at the same time within 50mm from the cat door for code matching.If the sound is heard once and the indicator light is off,the code matching is successful.If there is no operation after 30 seconds of successful code matching,the code matching mode will be automatically exited,or if the M button is pressed for a long time again and a sound is heard,the code matching mode will be exited. 4) Clear the matching code: After pressing the M button for a long time, the battery is installed and powered on. After the sound rings three times and the indicator light goes out, the saved matching code is successfully cleared. Press the M key again to activate when done. 6. The effective sensing distance of the RFID key is within 20CM of the front of the cat door. 7. When the battery is in a low state, the cat door will continuously emit a "beep beep' sound, and all indicator lights will be on at the same time. The cat door will enter a locked state,prompting to replace the battery 8. When the battery is low or not working, you can manually rotate the center button with a coin to adjust the exit/entry modes. 10. Install step 11. Precautions 1) After the battery is installed, the machine works normally if a "drop" sound ishear d and the indicator light is on. 2) Check that the FP key has been turned to the ON position. 3) After powering on, the induction key of the smart cat door and the remotecont roller are operated by code matching. 4) When the RFID key cannot be recognized, please reset the matching code. 5) When the battery voltage is too low, the cat door will enter a locked state, and the cat door will continuously emit a "beep beep" sound, Do not restart until thebatt ery is replaced with a new one. (Or manual rotation mode) 6) When the door cannot be opened due to the rotation deviation of the cat doorlock, it indicates that the battery power is low and the battery can be replaced. 7)When the cat approaches, the four lights flash. At this time, the Hall switch on the control panel cannot detect the magnet on the door. Please check whether the door is closed. Whether the magnet polarity on the door panel is installed inthe wrong direction,etc. 8) When the cat approaches, the corresponding access control indicator lights up, but the door cannot be opened. Please check whether the shaft plate and the door plate have been pasted,resulting in too much resistance and the mot…
Text truncated - open the document above for the full version.
1/1 USAgentforServiceofProcessLETTEROFATTESTATION TO: OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USAgentforServiceofProcess: CompanyName:HOPEKCORPORATIONINC Address:16755CoyoteBushDrUnit84,SanDiego,CA92127UnitedStates FRN:0034562900 ContactName:YangyangXu TelephoneNo:(561)875-9826 E-mail:[email protected] ThisletteristoconfirmthattheUSAgentforServiceofProcessacceptsresponsibilitytoactas alocalrepresentativeonbehalfofShenzhenSenhaiyunyeTechnologyCo.,LTD TheUSAgentforServiceofProcessisawareofandagreestocomplywiththerequirements outlinedintheFCCEquipmentAuthorizationProgram,ReportandOrderFCC22-84,andclause §2.911. Applicant: CompanyName:ShenzhenSenhaiyunyeTechnologyCo.,LTD ProductDescription:RemoteControl FRN:0032105371 GranteeCode:2A5QI FCCID:2A5QI-DM-710RC ContactName:BingTan Address:Floor5th,BuildingB2,No.3IndustrialArea,DawangshanCommunity,Shajing Street,Bao’anDistrict,Shenzhen,China TelephoneNo:13538218145 E-mail:[email protected] TheApplicantisawareofandagreestocomplywiththerequirementsoutlinedintheFCC EquipmentAuthorizationProgram,ReportandOrderFCC22-84,andclause§2.911. ThisAgreementisvaliduntil(Permanentlyvalid). Date:2026/8/29 Applicant’sName: ShenzhenSenhaiyunyeTechnologyCo.,LTD USAgentforServiceofProcess’sName: HOPEKCORPORATIONINC Title:EngineerTitle:Manager SignatureSignature
Rev 1/26/2023 ShenzhenSenhaiyunyeTechnologyCo.,LTD Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: Aug. 13, 2026 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2A5QI-DM-710RC [ShenzhenSenhaiyunyeTechnologyCo.,LTD] certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. [ShenzhenSenhaiyunyeTechnologyCo.,LTD] certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Sincerely, (Applicant signature) (Applicant printed name) Bing Tan Rev 1/26/2023 ShenzhenSenhaiyunyeTechnologyCo.,LTD Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: Aug. 13, 2026 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2A5QI-DM-710RC [ShenzhenSenhaiyunyeTechnologyCo.,LTD] certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) Bing Tan
ShenzhenSenhaiyunyeTechnologyCo.,LTD Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: August 29, 2026 Subject; Request for Confidentiality FCC ID: 2A5QI-DM-710RC To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure Software Security Requirements for UNII devices In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Bing Tan Title: Engineer
Effective Date: April 2, 2020 QSF 7.6.4-8 – Agent Authorization Letter Template Page 1 of 1 Revision Date: Revision: 0 ShenzhenSenhaiyunyeTechnologyCo.,LTD Date: Aug. 13, 2026 Product Model Number: DM-710 FCC ID: 2A5QI-DM-710RC To whom it may concern, Re: Product Certification Representative Authorization Letter We authorize QAI Laboratories Ltd. 3980 North Fraser Way, Burnaby B.C. Canada V5J 5K5 to act on our behalf on all matters concerning the above named equipment. This shall include the following:  Testing  Approval applications and procedures We declare that QAI Laboratories Ltd. is allowed to forward all information related to the approval project to the applied certification body and to the notification entities and to discuss any issues concerning the approval application. Any and all acts carried out by QAI Laboratories Ltd. on our behalf shall have the same effect as acts of our own. By: Contact Listed on FCC Wesbite Title: Engineer Email: [email protected] Telephone: 13538218145 On behalf of: ShenzhenSenhaiyunyeTechnologyCo.,LTD
Ext Photos Model: DM-710 Photo 1 Photo 2 Photo 3 Photo 4 Photo 5 Photo 6 Photo 7
Int Photos Model: DM-710 Photo 1 Photo 2 Photo 3 Photo 4 ANT ANT Photo 5
- Page 1 of 9 - Report No.: HB20260727007E-02 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com RF EXPOSURE Test Report Product: Remote Control Trade Mark: N/A Model Number: DM-710 FCC ID: 2A5QI-DM-710RC Prepared for ShenzhenSenhaiyunyeTechnologyCo.,LTD Floor5th,BuildingB2,No. 3IndustrialArea,DawangshanCommunity, Shajing Street,Bao’anDistrict,Shenzhen,China Prepared by Shenzhen HongBiao Certification& Testing Co., Ltd Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen, China Tel.: +86-755-2998 9321 Fax.: +86-755-2998 5110 Website: http://www.sz-hongbiao.com - Page 2 of 9 - Report No.: HB20260727007E-02 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com Table of Contents 1 GENERAL DESCRIPTION ..................................................................................................................................... 5 1.1 DESCRIPTION OF EUT ................................................................................................................................................ 5 1.2 TEST MODE .............................................................................................................................................................. 5 1.3 TEST SETUP .............................................................................................................................................................. 5 1.4 ANCILLARY EQUIPMENT .............................................................................................................................................. 5 2 TEST FACILITIES AND ACCREDITATIONS .............................................................................................................. 6 2.1 TEST LABORATORY ..................................................................................................................................................... 6 2.2 ENVIRONMENTAL CONDITIONS ..................................................................................................................................... 6 2.3 MEASUREMENT UNCERTAINTY ..................................................................................................................................... 6 2.4 TEST SOFTWARE ........................................................................................................................................................ 6 3 LIST OF TEST EQUIPMENT .................................................................................................................................. 7 4 RF EXPOSURE..................................................................................................................................................... 8 4.1 STANDALONE SAR TEST EXCLUSION CONSIDERATIONS........................................................................................................ 8 4.1.1. Limit ............................................................................................................................................................ 8 4.1.2. Test Procedures ........................................................................................................................................... 8 4.1.3. Test Result ................................................................................................................................................... 9 - Page 3 of 9 - Report No.: HB20260727007E-02 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com TEST RESULT CERTIFICATION Applicant’s Name ................. : ShenzhenSenhaiyunyeTechnologyCo.,LTD Address ................................. : Floor5th,BuildingB2,No.3IndustrialArea,DawangshanCommunity, Shajing Street,Bao’anDistrict,Shenzhen,China Manufacturer's Name .......... : ShenzhenSenhaiyunyeTechnologyCo.,LTD Address ................................. : Floor5th,BuildingB2,No.3IndustrialArea,DawangshanCommunity, Shajing Street,Bao’anDistrict,Shenzhen,China Product description Product name ........................ : Remote Control Model Number ....................... : DM-710 Standards ............................. : FCC CFR 47 PART 1 , 1.1310 Test procedure ....................... : KDB 447498 D01 General RF Exposure Guidance v06 This device described above has been tested by Shenzhen HongBiao Certification& Testing Co., Ltd and the test results show that the equipment under test (EUT) is in compliance with the EMC requirements. And it is applicable only to the tested sample identified in the report. Date of Test ........................................... : Date (s) of performance of tests ............. : July 27, 2026~Aug. 13, 2026 Test Result .............................................. : Pass Testing Engineer : ( Z o e Su) Technical Manager : (M i n g Liu) Authorized Signatory : (L e o S u) - Page 4 of 9 - Report No.: HB20260727007E-02 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com Revision History Revised No. Date of Issue Description 01 Aug. 13, 2026 Original - Page 5 of 9 - Report No.: HB20260727007E-02 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com 1 General Description 1.1 Description o…
Text truncated - open the document above for the full version.
Maximum Antenna Gain: 2.1 dBi Antenna type: Onboard antenna ShenzhenSenhaiyunyeTechnologyCo.,LTD Floor5th,BuildingB2,No.3IndustrialArea,DawangshanCommunity, Shajing Street,Bao’anDistrict,Shenzhen,China
- Page 1 of 33 - Report No.: HB20260727007E-01 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com Test Report Product: Remote Control Trade Mark: N/A Model Number: DM-710 FCC ID: 2A5QI-DM-710RC Prepared for ShenzhenSenhaiyunyeTechnologyCo.,LTD Floor5th,BuildingB2,No. 3IndustrialArea,DawangshanCommunity, Shajing Street,Bao’anDistrict,Shenzhen,China Prepared by Shenzhen HongBiao Certification& Testing Co., Ltd Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen, China Tel.: +86-755-2998 9321 Fax.: +86-755-2998 5110 Website: http://www.sz-hongbiao.com - Page 2 of 33 - Report No.: HB20260727007E-01 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com Table of Contents 1 GENERAL DESCRIPTION ..................................................................................................................................... 5 1.1 DESCRIPTION OF EUT ................................................................................................................................................ 5 1.2 TEST MODE .............................................................................................................................................................. 5 1.3 OPERATION CHANNEL LIST ........................................................................................................................................... 5 1.4 TEST SETUP .............................................................................................................................................................. 5 1.5 ANCILLARY EQUIPMENT .............................................................................................................................................. 5 2 SUMMARY OF TEST RESULT ............................................................................................................................... 6 3 TEST FACILITIES AND ACCREDITATIONS .............................................................................................................. 7 3.1 TEST LABORATORY ..................................................................................................................................................... 7 3.2 ENVIRONMENTAL CONDITIONS ..................................................................................................................................... 7 3.3 MEASUREMENT UNCERTAINTY ..................................................................................................................................... 7 3.4 TEST SOFTWARE ........................................................................................................................................................ 8 4 LIST OF TEST EQUIPMENT .................................................................................................................................. 9 5 TEST ITEM AND RESULTS ...................................................................................................................................11 5.1 ANTENNA REQUIREMENT .......................................................................................................................................... 11 5.1.1 Standard Requirement ............................................................................................................................. 11 5.1.2 Test Result ................................................................................................................................................. 11 5.2 AC POWER LINE CONDUCTED EMISSION ...................................................................................................................... 12 5.2.1 Limits ........................................................................................................................................................ 12 5.2.2 Test Procedures ......................................................................................................................................... 12 5.2.3 Test Setup .................................................................................................................................................. 13 5.2.4 Test Result ................................................................................................................................................. 13 5.3 RADIATED EMISSION FIELD STRENGTH OF FUNDAMENTAL AND HARMONIC EMISSIONS .......................................................... 14 5.3.1 Limits ........................................................................................................................................................ 14 5.3.2 Test Procedures ......................................................................................................................................... 15 5.3.3 Test Setup .................................................................................................................................................. 15 5.3.4 Test Result ................................................................................................................................................. 17 5.4 RADIATED EMISSION AND BAND EDGE SPURIOUS EMISSION............................................................................................. 19 5.4.1 Limit .......................................................................................................................................................... 19 5.4.2 Test Procedure ........................................................................................................................................…
Text truncated - open the document above for the full version.
Test Setup Model: DM-710 Radiated Emission Below 1GHz Radiated Emission Above 1GHz
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.92 MHz - 433.92 MHz | - |

Smart Pet Door
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
GPS Fence
Equipment Class
JAB - Part 15 Class B Digital Device