FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. AXEND,Inc./
  3. 2A5R6VF060-F2

2A5R6VF060-F2Perimeter Surveillance Terminal

AXEND,Inc.

Application Details

Equipment Class
FDS - Part 15 Field Disturbance Sensor
Date of Grant
Aug 18, 2026
Application Purpose
Original Equipment
Equipment Note
Perimeter Surveillance Terminal
Frequency Range
61000.00000000 - 61500.00000000
Company
AXEND,Inc.
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗
↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

ID Label/Location Info

Input: DC 12V 3A / POE Power Consumption: ≤30WFCC ID: 2A5R6VF060-F2 www.ax-end.com SN: Model: VF060-F2 Perimeter Surveillance Terminal

RF Exposure Info

Sporton International Inc. (Kunshan) Page Number : 1 of 7 TEL : +86-512-57900158 Report Issued Date : Aug. 11, 2026 FCC ID : 2A5R6VF060-F2 Report Version : Rev. 01 RF Exposure Evaluation Report Report No. : FA642992 RF Exposure Evaluation Report APPLICANT : AXEND,Inc. EQUIPMENT : Perimeter Surveillance Terminal MODEL NAME : VF060-F2, VF060-F1, TXPW60-6/8F, TXPW60-6/4F, RA60, TXPR60 FCC ID : 2A5R6VF060-F2 STANDARD : 47 CFR Part 2.1091 FCC KDB 447498 D01 v06 The product evaluation date was started from Aug. 07, 2026 and completed on Aug. 07, 2026. We, Sporton International Inc. (Kunshan), would like to declare that the device has been evaluated in accordance with 47 CFR Part 2.1091 and FCC KDB 447498 D01 v06, and pass the limit. Without written approval of Sporton International Inc. (Kunshan), the test report shall not be reproduced except in full. Approved by: Si Zhang Sporton International Inc. (Kunshan) No. 1098, Pengxi North Road, Kunshan Economic Development Zone Jiangsu Province 215300 People’s Republic of China Sporton International Inc. (Kunshan) Page Number : 2 of 7 TEL : +86-512-57900158 Report Issued Date : Aug. 11, 2026 FCC ID : 2A5R6VF060-F2 Report Version : Rev. 01 RF Exposure Evaluation Report Report No. : FA642992 Table of Contents 1. ADMINISTRATION DATA ........................................................................................................................... 4 1.1. Testing Laboratory ............................................................................................................................. 4 2. DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ............................................................................. 5 3. MAXIMUM RF OUTPUT TUNE UP POWER (UNIT: DBM) ........................................................................ 5 4. RF EXPOSURE LIMIT INTRODUCTION .................................................................................................... 6 5. RADIO FREQUENCY RADIATION EXPOSURE EVALUATION ............................................................... 7 5.1. Standalone Power Density Calculation ............................................................................................. 7 Sporton International Inc. (Kunshan) Page Number : 3 of 7 TEL : +86-512-57900158 Report Issued Date : Aug. 11, 2026 FCC ID : 2A5R6VF060-F2 Report Version : Rev. 01 RF Exposure Evaluation Report Report No. : FA642992 Revision History REPORT NO. VERSION DESCRIPTION ISSUED DATE FA642992 Rev. 01 Initial issue of report. Aug. 11, 2026 Sporton International Inc. (Kunshan) Page Number : 4 of 7 TEL : +86-512-57900158 Report Issued Date : Aug. 11, 2026 FCC ID : 2A5R6VF060-F2 Report Version : Rev. 01 RF Exposure Evaluation Report Report No. : FA642992 1. Administration Data 1.1. Testing Laboratory Sporton International Inc. (Kunshan) is accredited to ISO/IEC 17025:2017 by American Association for Laboratory Accreditation with Certificate Number 5145.02. Testing Laboratory Test Firm Sporton International Inc. (Kunshan) Test Site Location No. 1098, Pengxi North Road, Kunshan Economic Development Zone Jiangsu Province 215300 People’s Republic of China TEL : +86-512-57900158 Test Site No. Sporton Site No. FCC Designation No. FCC Test Firm Registration No. SAR01-KS CN1257 314309 Applicant Company Name AXEND,Inc. Address 2637 Manhattan Beach Blvd, Redondo Beach,CA 90278,USA Manufacturer Company Name AXEND,Inc. Address 2637 Manhattan Beach Blvd, Redondo Beach,CA 90278,USA Sporton International Inc. (Kunshan) Page Number : 5 of 7 TEL : +86-512-57900158 Report Issued Date : Aug. 11, 2026 FCC ID : 2A5R6VF060-F2 Report Version : Rev. 01 RF Exposure Evaluation Report Report No. : FA642992 2. Description of Equipment Under Test (EUT) Product Feature & Specification EUT Type Perimeter Surveillance Terminal Model Name VF060-F2, VF060-F1, TXPW60-6/8F, TXPW60-6/4F, RA60, TXPR60 FCC ID 2A5R6VF060-F2 Wireless Technology and Frequency Range Radar: 61.0 GHz ~ 61.5 GHz Mode FMCW Antenna Type Radar : Patch array antenna Remark: 1. The above EUT's information was declared by manufacturer. Please refer to the specifications or user's manual for more detailed description. 2. The different model names are intended for different sales territories, and these differences do not affect the MPE analysis results. Comments and Explanations: 1. The declared of product specification for EUT presented in the report are provided by the manufacturer, and the manufacturer takes all the responsibilities for the accuracy of product specification. 2. The maximum RF output tune up power, antenna gain also the safe distance used for evaluate RF exposure were declared by manufacturer. 3. Maximum RF Output Tune Up Power (Unit: dBm) <Radar > Band Maximum EIRP power(dBm) Radar 12.00 Sporton International Inc. (Kunshan) Page Number : 6 of 7 TEL : +86-512-57900158 Report Issued Date : Aug. 11, 2026 FCC ID : 2A5R6VF060-F2 Report Version : Rev. 01 RF Exposure Evaluation Report Report No. : FA642992 4. RF Exposure Limit Introduction According to ANSI/IEEE C95.1-1992, the criteria listed in Table 1 shall be used to evaluate the environmental impact of human exposure to radio frequency (RF) radiation as specified in §1.1310. The MPE was calculated at 20 cm to show compliance with the power density limit. The following formula was used to calculate the Power Density: = Where: S = Power Density P = Output Power at Antenna Terminals G = Gain of Transmit Antenna (linear gain) R = Distance from Transmitting Antenna Sporton International Inc. (Kunshan) Page Number : 7 of 7 TEL : +86-512-57900158 Report Issued Date : Aug. 11, 2026 FCC ID : 2A5R6VF060-F2 Report Version : Rev. 01 RF Exposure Evaluation Report Report No. : FA642992 5. Radio Frequency Radiation Exposure Evaluation 5.1. Standalone Power Density Calculation Band Frequency (MHz) Maximum EIRP (dBm) Maximum EIRP (W) Average EIRP (mW) Power Density at 20cm (mW/cm^2) Limit (mW/cm^2) Radar 61000 12.000 0.016 15.849 0.003 1.000 Note: …

Text truncated - open the document above for the full version.

Test Report

TEL: 886-3-327-0868 Page Number : 1 of 31 FAX: 886-3-327-0855 Issue Date : Aug. 18, 2026 Report Template No.: BU5-FR15.255 Version 1.0 Report Version : 02 FCC RADIO TEST REPORT Report No.: FR650103 FCC RADIO TEST REPORT FCC ID : 2A5R6VF060-F2 Equipment : Perimeter Surveillance Terminal Model Name : VF060-F2, VF060-F1, TXPW60-6/8F, TXPW60-6/4F, RA60, TXPR60 Applicant : AXEND, Inc. 2637 Manhattan Beach Blvd, Redondo Beach, CA 90278, USA Manufacturer : AXEND, Inc. 2637 Manhattan Beach Blvd, Redondo Beach, CA 90278, USA Standard : FCC 47 CFR Part 15.255 The product was received on May 13, 2026 and testing was performed from Jun. 01, 2026 to Aug. 14, 2026. We, Sporton International Inc. Wensan Laboratory, would like to declare that the tested sample has been evaluated in accordance with the test procedures and has been in compliance with the applicable technical standards. The test results in this report apply exclusively to the tested model / sample. Without written approval from Sporton International Inc. Wensan Laboratory, the test report shall not be reproduced except in full. Approved by: Louis Wu Sporton International Inc. Wensan Laboratory No.58, Aly. 75, Ln. 564, Wenhua 3rd, Rd., Guishan Dist., Taoyuan City 333010, Taiwan (R.O.C.) TEL: 886-3-327-0868 Page Number : 2 of 31 FAX: 886-3-327-0855 Issue Date : Aug. 18, 2026 Report Template No.: BU5-FR15.255 Version 1.0 Report Version : 02 FCC RADIO TEST REPORT Report No.: FR650103 Table of Contents History of this test report ................................................................................................................................. 3 Summary of Test Result................................................................................................................................... 4 1 General Description ................................................................................................................................... 5 1.1 Feature of Equipment Under Test ..................................................................................................... 5 1.2 Modification of EUT ........................................................................................................................... 5 1.3 Testing Location ................................................................................................................................ 5 1.4 Applied Standards ............................................................................................................................. 5 2 Test Configuration of Equipment Under Test ......................................................................................... 6 2.1 Test Mode.......................................................................................................................................... 6 2.2 Connection Diagram of Test System ................................................................................................ 6 2.3 Far Field Condition for Frequency above 18GHz.............................................................................. 7 3 Radiated Test Items ................................................................................................................................... 8 3.1 Measuring Instruments ...................................................................................................................... 8 3.2 Test Setup ......................................................................................................................................... 8 3.3 Test Result of Radiated Test ............................................................................................................. 9 3.4 Occupied Bandwidth ....................................................................................................................... 10 3.5 EIRP Power Measurement .............................................................................................................. 12 3.6 Transmit Spurious Emission ............................................................................................................ 15 3.7 Frequency Stability .......................................................................................................................... 25 4 AC conducted Emission Measurement ................................................................................................. 26 4.1 Limit of AC Conducted Emission ..................................................................................................... 26 4.2 Measuring Instruments .................................................................................................................... 26 4.3 Test Procedures .............................................................................................................................. 26 4.4 Test Setup ....................................................................................................................................... 27 4.5 Test Result of AC Conducted Emission .......................................................................................... 27 5 List of Measuring Equipment .................................................................................................................. 28 6 Measurement Uncertainty ....................................................................................................................... 31 Appendix A. AC Conducted Emission Test Result Appendix B. Setup Photographs TEL: 886-3-327-0868 Page Number : 3 of 31 FAX: 886-3-327-0855 Issue Date : Aug. 18, 2026 Report Template No.: BU5-FR15.255 Version 1.0 Report Version : 02 FCC RADIO TEST REPORT Report No.: FR650103 History of this test report Report No. Version Description Issue Date FR650103 01 Initial issue of report Jul. 22, 2026 FR650103 02 Update the version of Applied Standard in section 1.4 Update the test plot and test result in section 3.4 Revise the test procedure in section 3.4.3 Update List…

Text truncated - open the document above for the full version.

Test Report

Manufacturer AXEND,Inc. ModuleName 60GPerimeterSurveillanceTerminalAntenna MaxGain11.95dBi 6dBantennawidth(azimuth)+65.25~-63.62degree 6dBantennawidth(elevation)+10.25~-12.99degree Antennatype Patcharrayantenna(RX) Simulationresults Antennasize Manufacturer AXEND,Inc. ModuleName 60GPerimeterSurveillanceTerminalAntenna MaxGain12.12dBi 6dBantennawidth(azimuth)+57.35~-59.16degree 6dBantennawidth(elevation)+9.69~-12.23degree Antennatype Patcharrayantenna(TX) Simulationresults Antennasize

Contact Information

Applicant

Leo Zhou
[email protected]Fax: N/A

Technical Contact

AXEND,Inc.Leo Zhou

2637 Manhattan Beach Blvd,Redondo Beach, · Los Angeles, California, 90278 · United States

Test Firm

Sporton International Inc. Wensan LaboratoryAlex CHEN
[email protected]Fax: +886-3-327-0978

Technical Specifications

#Rule PartsFrequency RangePower Output
115.25561.00 GHz - 61.50 GHz122.50 mW
Confidentiality
Long Term
Grant Notes
Output power list is EIRP. Device must be operated to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.