FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

ยฉ 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Zhejiang Unionx Electric Machinery Technology Co., LTD./
  3. 2A5TU-XP0501

2A5TU-XP0501Automatic Key Cutting Machine with Bluetooth

Zhejiang Unionx Electric Machinery Technology Co., LTD.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 27, 2024
Application Purpose
Original Equipment
Date of Application
Mar 27, 2024
Equipment Note
Automatic Key Cutting Machine with Bluetooth
Frequency Range
2402.00000000 - 2480.00000000
Company
Zhejiang Unionx Electric Machinery Technology Co., LTD.
Country
China

Documents & Files

Select a file to view

Attestation Statements

โ†—
โ†—

Cover Letter(s)

โ†—
โ†—

ID Label/Location Info

โ†—

RF Exposure Info

โ†—

Test Report

โ†—
โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

,CHINA ,USA Automatic Key Cutting Machine

ID Label/Location Info

1ใ€Label 2ใ€location(on the back)

RF Exposure Info

NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 1 of 9 REPORT No.๏ผšSZ23110292S01 RF EXPOSURE EXEMPT REPORT APPLICANT : Zhejiang Unionx Electric Machinery Technology Co., LTD. PRODUCT NAME : Automatic Key Cutting Machine MODEL NAME : XP-005 BRAND NAME : Xhorse FCC ID : 2A5TU-XP0501 STANDARD(S) : 47 CFR Part 2(2.1093) RECEIPT DATE : 2023-11-27 TEST DATE : 2023-12-20 to 2024-02-27 ISSUE DATE : 2024-03-25 Edited by: Peng Mi (Rapporteur) Approved by: Shen Junsheng (Supervisor) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 2 of 9 REPORT No.๏ผšSZ23110292S01 DIRECTORY 1. Technical Information โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 3 1.1 Applicant and Manufacturer Information โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 3 1.2 Equipment Under Test (EUT) Description โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 3 1.3 Applied Reference Documents โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 4 2. Device Category and RF Exposure Limit โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 5 3. Maximum Average Power Summary โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 6 4. RF Exposure Assessment โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 7 Annex A Testing Laboratory Information โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 9 Change History Version Date Reason for change 1.0 2024-03-25 First edition MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 3 of 9 REPORT No.๏ผšSZ23110292S01 1. Technical Information Note: Provide by applicant. 1.1 Applicant and Manufacturer Information Applicant: Zhejiang Unionx Electric Machinery Technology Co., LTD. Applicant Address: NO.28 YUNSHAN MIDDLE ROAD, SANQISHI TOWN, YUYAO, ZHEJIANG PROVINCE Manufacturer: Zhejiang Unionx Electric Machinery Technology Co., LTD. Manufacturer Address: NO.28 YUNSHAN MIDDLE ROAD, SANQISHI TOWN, YUYAO, ZHEJIANG PROVINCE 1.2 Equipment Under Test (EUT) Description Product Name: Automatic Key Cutting Machine Sample No.: 10# Hardware Version: V2.1.6 Software Version: V4.2.0 Equipment Type: Bluetooth LE Operating Frequency Range: 2402 MHzโ€“2480 MHz Modulation Type: GFSK Antenna Type: PCB Antenna Antenna Gain: 1.56 dBi MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 4 of 9 REPORT No.๏ผšSZ23110292S01 1.3 Applied Reference Documents Leading reference documents for testing: Identity Document Title Method Determination /Remark 47 CFR Part 2(2.1093) Radio Frequency Radiation Exposure Assessment: Portable devices No deviation KDB 447498 D04v01 RF Exposure Procedures and Equipment Authorization Policies for Mobile and Portable Devices No deviation Note 1: Additions to, deviation, or exclusions from the method shall be judged in the "method determination" column of add, deviate or exclude from the specific method shall be explained in the "Remark" of the above table. Note 2: When the test result is a critical value, we will use the measurement uncertainty give the judgment result based on the 95% confidence intervals. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 5 of 9 REPORT No.๏ผšSZ23110292S01 2. Device Category and RF Exposure Limit Per user manual, based on 47 CFR 2.1093, this device belongs to portable device category with General Population/Uncontrolled exposure. Portable Devices: 47 CFR 2.1093(b) For purposes of this section, a portable device is defined as a transmitting device designed to be used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the user. General Population/Uncontrolled Exposure: 47 CFR 2.1093(d) (2) Limits for General Population/Uncontrolled exposure: 0.08 W/kg as averaged over the whole-body and spatial peak SAR not exceeding 1.6 W/kg as averaged over any 1 gram of tissue (defined as a tissue volume in the shape of a cube). Exceptions are the hands, wrists, feet and ankles where the spatial peak SAR shall not exceed 4 W/kg, as averaged over any 10 grams of tissue (defined as a tissue volume in the shape of a cube). General Population/Uncontrolled limits apply when the general public may be exposed, or when persons that are exposed as a consequence of their employment may not be fully aware of the potential for exposure or do not exercise control over their exposure. Warning labels plaโ€ฆ

Text truncated - open the document above for the full version.

Test Report

Manufacturer:ZhejiangUnionxElectricMachineryTechnologyCo.,LTD. Address:NO.28YUNSHANMIDDLEROAD,SANQISHITOWN,YUYAO,ZHEJIANGPROVINCE Model:BT934IFA Gain:1.56dBi Antennasize: Antennapatterns:

Test Report

NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 1 of 56 REPORT No.๏ผšSZ23110292W01 TEST REPORT APPLICANT : Zhejiang Unionx Electric Machinery Technology Co., LTD. PRODUCT NAME : Automatic Key Cutting Machine MODEL NAME : XP-005 BRAND NAME : Xhorse FCC ID : 2A5TU-XP0501 STANDARD(S) : 47 CFR Part 15 Subpart C RECEIPT DATE : 2023-11-27 TEST DATE : 2023-12-20 to 2024-02-27 ISSUE DATE : 2024-03-25 Edited by: Peng Mi (Rapporteur) Approved by: Shen Junsheng (Supervisor) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 2 of 56 REPORT No.๏ผšSZ23110292W01 DIRECTORY 1. Summary of Test Result ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 4 1.1. Testing Applied Standards ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 5 1.2. Test Equipment List ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 6 1.3. Measurement Uncertainty ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 8 1.4. Testing Laboratory ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 8 2. General Description ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 9 2.1. Information of Applicant and Manufacturer ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 9 2.2. Information of EUT ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 9 2.3. Channel List of EUT ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 10 2.4. Test Configuration of EUT ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 11 2.5. Test Conditions ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 11 2.6. Test Setup Layout Diagram ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 11 3. Test Results ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 14 3.1. Antenna Requirement ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 14 3.2. Duty Cycle of Test Signal ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 15 3.3. Maximum Peak Conducted Output Power ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 16 3.4. Maximum Average Conducted Output Power ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 17 3.5. 6 dB Bandwidth ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 18 3.6. Conducted Spurious Emissions and Band Edge ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 19 3.7. Power Spectral Density ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 20 3.8. Conducted Emission ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 21 3.9. Restricted Frequency Bands ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 22 3.10. Radiated Emission ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 23 Annex A Test Data and Result ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 25 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 3 of 56 REPORT No.๏ผšSZ23110292W01 Change History Version Date Reason for change 1.0 2024-03-25 First edition MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 4 of 56 REPORT No.๏ผšSZ23110292W01 1. Summary of Test Result No. Section Description Test Date Test Engineer Result Method Determination /Remark 1 15.203 Antenna Requirement N/A N/A PASS No deviation 2 N/A Duty Cycle of Test Signal Feb. 26, 2024 Zhong Yanshan PASS No deviation 3 15.247(b) Maximum Peak Conducted Output Power Feb. 26, 2024 Zhong Yanshan PASS No deviation 4 15.247(b) Maximum Average Conducted Output Power Feb. 26, 2024 Zhong Yanshan PASS No deviation 5 15.247(a) Bandwidth Feb. 26, 2024 Zhong Yanshan PASS No deviation 6 15.247(d) Conducted Spurious Emission and Band Edge Feb. 26, 2024 Zhong Yanshan PASS No deviation 7 15.247(e) Power Spectral Density Feb. 26, 2024 Zhong Yanshan PASS No deviation 8 15.207 Conducted Emission Dec. 25, 2023 to Jan. 30,2024 Wang Deyong PASS No deviation 9 15.247(d) Restricted Frequency Bands Feb. 21, 2024 Yang Lian PASS No deviation 10 15.209, 15.247(d) Radiated Emission Dec. 20, 2023 Gao Jianrou PASS No deviation Note 1: The tests were performed according to the method of measurements prescribed in ANSI C63.10-2013 and KDB 558074 D01 v05r02. Note 2: Additions to, deviation, or exclusions from the method shall be judged in the โ€œmethod determinationโ€ column of add, deviate or exclude from the specific method shall be explained in the โ€œRemarkโ€ of the above table. Note 3: When โ€ฆ

Text truncated - open the document above for the full version.

Contact Information

Applicant

Qiang Zhu(Business Manager)
[email protected]0755-86704336Fax: 0755-86704336

Test Firm

Shenzhen Morlab Communications Technology Co. Ltd.Mr. Su Feng
[email protected]+86 755 36698566

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.51 mW
Confidentiality
Long Term
Grant Notes
Output power is maximum peak conducted.

Other Applications from Zhejiang Unionx Electric Machinery Technology Co., LTD.

2A5TU-XCMT01

Automatic Key Cutting Machine

Feb 04, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter