FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. International Precision Instrument Corp/
  3. 2A5UB100-700-B06

2A5UB100-700-B06Digital Caliper Absolute Origin Smart Bluetooth Connectivity

International Precision Instrument Corp
Digital Caliper Absolute Origin Smart Bluetooth Connectivity - FCC ID 2A5UB100-700-B06 - International Precision Instrument Corp
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 07, 2022
Application Purpose
Original Equipment
Date of Application
Apr 07, 2022
Equipment Note
Digital Caliper Absolute Origin Smart Bluetooth Connectivity
Frequency Range
2402.00000000 - 2480.00000000
Company
International Precision Instrument Corp
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

**Please read through this owner’s manual carefully before using the gauge. Use the tool properly and only for its intend use. This digital caliper uses the highly accurate ABSOLUTE encoder technology. It memories its origin zero position at all time. When turned on, it will display its actual position and ready to use without any additional set ups or calibration. IP54 protective rating. Wireless data output function is compatible with most Bluetooth enabled electronic digital devices. 3 4 5 6 7 8 9 10 1 2 11 Parts: 1. Outside measuring surfaces 7. Wireless Data Output 2. Inside measuring surface 8. Function keys 3. Caliper body9. Wireless Data Indicator 4. Battery Compartment 10. Adjustment Roller 5. Locking screw11. Depth Bar 6. LCD Display Specification: Measuring speed: Unlimited Protection rating: IP54 Power: Battery 3V, CR2032; Storage temperature: 0-40°c Operating environment: 0-40°c; humidity: <80% Operations: - Press Power key to switch unit on or off. To conserve power, please turn the unit off when not in use. - Press UNIT key to select desired measurement unit (inch or mm). - Press ABS/0(zero) key to switch between absolute measure and incremental zero measure. Absolute measure is based on the Origin setting zero. Relative zero gives the user the ability to set incremental zero. Short press to enter incremental mode; INC will display. Long press for 3 seconds to exit. - Press ORIGIN key to reset origin zero. Manufacture pre-set Origin at zero position where the two outside measuring surfaces gently touched. If Origin needs to be reset, press Origin key for 5 seconds and display will show “0.00mm” and a new origin zero has been set. - Battery: When battery sign starts flashing or no display, a new battery is needed. Remove the old battery by removing the battery cover with the rubber insert; Install a new 3V CR2032 battery with “+” side facing out. Please recycle responsibly. Turn on the display and follow the instruction to reset Origin. Please keep the battery compartment sealed at all time. instruction Item# 100-700-B04,B06,B08,B12 Item#RangeResolutionAccuracy 100-700-B04 0-4” / 0-100mm 0.0005”/0.01mm 0.001”/0.02mm 100-700-B06 0-6” / 0-150mm 0.0005”/0.01mm 0.001”/0.02mm 100-700-B08 0-8” / 0-200mm 0.0005”/0.01mm 0.0015”/0.03mm 100-700-B12 0-12” / 0-300mm 0.0005”/0.01mm 0.0015”/0.03mm T his product will work with most of the electronic devices with Bluetooth connectivity. * It is recommended not to turn on or use the data output option within the first 10 seconds of usage. - First time use : turn on Bluetooth discovery feature on your electronic device. Press and hold Data Button on the caliper for 5 seconds, or until your device discoveries “Bluetooth Keyboard”; release the Data Button. Please confirm by choose “Bluetooth Keyboard” on your device. Open a program or an APP, short press the Data Button to export data. Wireless Data Output Indicator will continue to flash in slow sequence during the time of use. To output data in a program like Excel, please make sure to format the number display to at least 5 decimals. For some IOS applications, please make sure to switch off “Caps Lock Latin Switch” in Hardware Keyboard under Keyboard setup. - Reconnect : If the “Bluetooth Keyboard” is already registered with your electronic device previously, hold Data Button for 3 seconds and release for reconnecting. Depending on the receiving device, it maybe necessary to reconnect after a 5 minutes of none usage. - Switch between programs : If user is switching programs, “Bluetooth Keyboard” should be able to access all applications freely. In the event if the data would not transmit to a different application, please use “disconnect” or “forget” device option from your Bluetooth setup, and reconnect. - Connect to another device: Temporarily turn off the Bluetooth on your first device. Follow the “First time use” steps to establish Bluetooth connectivity on the second device. - Wireless connectivity will stop operating after 5 minutes of none usage to conserve power. Data transmitting frequency: approximately 1.5 second per one data output. Trouble shooting: If gauge is not functioning correctly, remove the battery for master reset. Wireless Data Outputs www.iGAGING.com S mart phone scan �Use soft cloth to clean instrument before and after usage. Never use organic solvents such as acetone or benzene to clean. �Please check with iGAGING for most updated product information. IGAGING® 2022 www.iGAGING.com San Clemente, California Manufacture supplied information. Information may change without notice. FC C CAUTION. TH IS D EVIC E C OMPLIES WITH PART 1 5 OF THE FC C RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS D EVICE MAY NOT CAUSE HARMFUL INTERFER EN CE, AN D (2) THIS D EVIC E MUST ACCEPT ANY INTERFEREN CE R EC EIVED, INCLUDING INTERFER EN CE TH AT MAY CAU SE UNDESIRED OPERATION. ANY CHAN GES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY R ESPONSIBLE FOR COMPLIANCE C OU LD VOID THE USER'S AUTHOR ITY TO OPERATE THE EQUIPMENT. NOTE: THIS EQUIPMENT HAS BEEN TESTED AND FOUN D TO COMPLY WITH THE LIMITS FOR A CLASS B DIGITAL DEVICE, PURSUANT TO PART 15 OF THE FC C RULES. THESE LIMITS ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST HARMFUL INTERFER EN CE IN A RESID EN TIAL INSTALLATION. TH IS EQUIPMENT GENERATES USES AND CAN RADIATE RADIO FREQUENCY ENER GY AND, IF NOT INSTALLED AND U SED IN ACCORDAN CE WITH THE INSTRUCTIONS, MAY CAUSE HAR MFU L INTERFER EN CE TO RAD IO C OMMUNICATIONS. HOWEVER, THER E IS NO GU AR AN TEE THAT INTERFER EN CE WILL NOT OCCUR IN A PARTICULAR INSTALLATION. IF TH IS EQUIPMENT D OES CAU SE HARMFUL INTERFER EN CE TO RAD IO OR TELEVISION RECEPTION, WH ICH CAN BE DETERMINED BY TURNING THE EQUIPMENT OFF AND ON, THE U SER IS ENCOURAGED TO TRY TO COR REC T TH E INTERFER EN CE BY ONE OR MORE OF THE FOLLOWING MEASURES: -R EOR IENT OR RELOCATE THE R EC EIVIN G AN TEN NA. -INCREASE THE SEPARATION BETWEEN THE EQUIPMENT AND REC EIVER. -CONNEC T …

Text truncated - open the document above for the full version.

Attestation Statements

Page1of1 Declarationonmodeldifference We,InternatinalPrecisionInstrumentCorp,theundersignedhereby confirmthatthesemodelsareidentical,andallmodelshavethesameRF moduleandAntenna,exceptforthesize. ProductnameDigitalCaliperAbsoluteOriginSmartBluetoothConnectivity ModelNo. 100-700-B06 100-700-B04,100-700-B08,100-700-B12 TradenameiGAGING FCCID2A5UB100-700-B06 INPUTBattery Confirmedby: Client’ssignature: Client’sname/title:WilliamZhang/Manager Date:2022-03-24

Cover Letter(s)

C5266091_X8_Ed.1 1/1 LetterofAuthorization InternatinalPrecisionInstrumentCorp Company:InternatinalPrecisionInstrumentCorp Address:1206PuertaDelSol,SanclementCA92673USA ProductName:DigitalCaliperAbsoluteOriginSmartBluetooth Connectivity ModelNumber:100-700-B06 100-700-B04,100-700-B08,100-700-B12 WeauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdelCarme,s/n, 08193Bellaterra,Spain,toactonourbehalfonallmattersconcerningthe abovenamedequipment. AnyindividualwithinLGAITechnologicalCenterS.A.isauthorizedtoactonour behalfandtakeactionontheapplication. WedeclarethatauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdel Carme,s/n,08193Bellaterra,Spain,isallowedtoforwardallinformation relatedtotheapprovalprojecttotheFederalCommunicationCommissionand todiscussanyissuesconcerningtheapprovalapplication.Anyandallacts carriedoutbyLGAITechnologicalCenterS.A.onourbehalfshallhavethe sameeffectasactsofourown. Name:WilliamZhangDate:2022-03-24 Title:Manager Signatureofapplicant:

Cover Letter(s)

C5266091_X10_Ed.2 1/1 InternatinalPrecisionInstrumentCorp OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:2022-03-24 Subject:RequestforConfidentiality FCCID:2A5UB100-700-B06 ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality NOTE2 IDLabel/LocationNoNo AttestationStatementNoNo ExternalPhotosNo ☐ BlockDiagram ☒☐ Schematics ☒☐ TestReportNoNo TestSetupPhotosNo ☐ User’sManual ☐ NOTE 1 ☐ InternalPhotos ☐ NOTE 1 ☐ PartsList/TuneUp ☐☐ RFExposureInfoNoNo OperationalDescription ☒☐ CoverLetter(s)NoNo SDRSoftware/SecurityInfo ☐ No NOTE1:Long-TermConfidentialitymaybepermittedunderspecialconditions(SeeII.LONG-TERMCONFIDENTIALITY,Section3of KDB726920,uselastinforce) NOTE2:Short-TermConfidentialitycanberequestedforamaximumof180daysfromthedateofthegrant. Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. Incaseofshort-termConfidentiality,theapplicantrequeststheexhibitsselected abovearewithheldfrompublicviewforaperiodofdaysfromthedateofthe GrantofEquipmentAuthorizationandpriortomarketing. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. Sincerely, C5266091_X10_Ed.2 1/1 Signature: Name: WilliamZhang Title:Manager

External Photos

FCC ID: 2A5UB100-700-B06

Internal Photos

FCC ID: 2A5UB100-700-B06

RF Exposure Info

1 / 2 RFEXPOSUREEVALUATION ProductName:DigitalCaliperAbsoluteOriginSmartBluetoothConnectivity ModelName:100-700-B06 Additionalmodel: 100-700-B04,100-700-B08,100-700-B12 Note:Therearedifferencesinsize BluetoothVersion:BT4.2BLE Operatingfrequency:2402-2480MHz NumbersofChannel:40channelsForBLE TypeofModulation:GFSk AntennaType:PCBAntenna AntennaGain:0dBi Powersupply:DC3V,30uA HardwareVersion:N/A SoftwareVersion: N/A 2 / 2 StandardRequirement Accordingto§15.247(i)and§1.1307b(1),systemsoperatingundertheprovisionsofthis sectionshallbeoperatedinamannerthatensuresthatthepublicisnotexposedtoradio frequencyenergylevelsinexcessoftheCommission’sguidelines.SeeKDB447498D01 GeneralRFExposureGuidancev06,section4.3.1. The1-gand10-gSARtestexclusionthresholdsfor100MHzto6GHzattestseparation distances≤50mmaredeterminedby: [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparationdistance, mm)]*[√f(GHz)]≤3.0for1-gSARand≤7.5for10-gSARextremitySAR,where f(GHz)istheRFchanneltransmitfrequencyinGHz PoweranddistanceareroundedtothenearestmWandmmbeforecalculation Theresultisroundedtoonedecimalplaceforcomparison. Thetestexclusionsareapplicableonlywhentheminimumtestseparationdistanceis≤ 50mmandfortransmissionfrequenciesbetween100MHzand6GHz.Whentheminimumtest separationdistanceis<5mm,adistanceof5mmisappliedtodetermineSARtestexclusion. RoutineSARevaluationreferstothatspecificallyrequiredby§2.1093,usingmeasurements orcomputersimulation.WhenroutineSARevaluationisnotrequired,portabletransmitters withoutputpowergreaterthantheapplicablelowthresholdrequireSARevaluationtoquality forTCBapproval. Channel (MHz) Maximum output power (dBm) Tuneup tolerance (dBm) MaxTuneUp Power(mW) Distance (mm) Calculation results Limit Operating Mode 2440 2.512.51±1 2.24388250.7010113BLE AccordingtoKDB447498,SARmeasurementisnotrequired. Signature WuWeimin EMCManager Date:2022-03-16

Test Report

Page 1 of 46 FCCTESTREPORT FCCID:2A5UB100-700-B06 Product:DigitalCaliperAbsoluteOriginSmartBluetoothConnectivity ModelName: 100-700-B06 100-700-B04,100-700-B08,100-700-B12 Brand:iGAGING ReportNo.:PTC22022303801E-FC01 Preparedfor InternatinalPrecisionInstrumentCorp 1206PuertaDelSol,SanclementCA92673USA Preparedby PreciseTesting&CertificationCo.,Ltd. Building1,No.6,TongxinRoad,DongchengStreet,Dongguan,Guangdong,China ReportNo.:PTC22022303801E-FC01 Page 2 of 46 1TESTRESULTCERTIFICATION Applicant’sname:InternatinalPrecisionInstrumentCorp Address:1206PuertaDelSol,SanclementCA92673USA Manufacture'sname:DONGGUANCITYTERMAELECTRONICSCO.,LTD Address:No.595,JienanRoad,Xiaojiejiao,HumenTown,DongguanCity Productname: No.101,building28,No.25,DongkeRoad,DongchengDistrict, DongguanCity,GuangdongProvince Modelname: 100-700-B06 100-700-B04,100-700-B08,100-700-B12 Standards:FCCCFR47Part15Section15.247 Testprocedure:ANSIC63.10:2013 TestDate:Mar.2,2022toMar.16,2022 DateofIssue:Mar.16,2022 TestResult:Pass ThisdevicedescribedabovehasbeentestedbyPTC,andthetestresultsshowthatthe equipmentundertest(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonly tothetestedsampleidentifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofPTC,this documentmaybealteredorrevisedbyPTC,personalonly,andshallbenotedintherevisionof thedocument. TestEngineer: AbelYu/Engineer TechnicalManager: WuWeimin/Manager ReportNo.:PTC22022303801E-FC01 Page 3 of 46 Contents Page 1TESTRESULTCERTIFICATION................................................................................................................................2 2TESTSUMMARY...........................................................................................................................................................5 2.1TESTSITE.............................................................................................................................................................6 3GENERALINFORMATION..........................................................................................................................................7 3.1GENERALDESCRIPTIONOFE.U.T.....................................................................................................................7 3.2CHANNELLIST......................................................................................................................................................8 4EQUIPMENTDURINGTEST.......................................................................................................................................9 4.1EQUIPMENTSLIST................................................................................................................................................9 4.2MEASUREMENTUNCERTAINTY..........................................................................................................................11 4.3DESCRIPTIONOFSUPPORTUNITS....................................................................................................................12 5CONDUCTEDEMISSION...........................................................................................................................................13 5.1E.U.T.OPERATION............................................................................................................................................13 5.2EUTSETUP........................................................................................................................................................13 5.3TESTSET-UP(BLOCKDIAGRAMOFCONFIGURATION)..................................................................................14 5.4MEASUREMENTPROCEDURE............................................................................................................................14 5.5CONDUCTEDEMISSIONLIMIT............................................................................................................................14 5.6MEASUREMENTDESCRIPTION...........................................................................................................................14 5.7CONDUCTEDEMISSIONTESTRESULT..............................................................................................................14 6RADIATEDSPURIOUSEMISSIONS.......................................................................................................................15 6.1EUTOPERATION...............................................................................................................................................15 6.2TESTSETUP.......................................................................................................................................................16 6.3SPECTRUMANALYZERSETUP...........................................................................................................................17 6.4TESTPROCEDURE.............................................................................................................................................18 6.5SUMMARYOFTESTRESULTS...........................................................................................................................20 7CONDUCTBANDEDGEANDSPURIOUSEMISSIONSMEASUREMENT....................................................27 7.1TESTPROCEDURE.............................................................................................................................................27 7.2TESTRESULT.....................................................................................................................................................28 86DBBANDWIDTHMEASUREMENT.......................................................................................................................31 8.1TESTPROCEDURE.............................................................................................................................................31 ReportNo.:PTC22022303801E-FC01 Page 4 of 46 8.2TESTRES…

Text truncated - open the document above for the full version.

Test Report

ReportNo.:PTC22022303801E-FC01 Page 41 of 46 12TestSetup RadiatedSpuriousEmissions From30M-1GHz TestfrequencyfromAbove1GHz ReportNo.:PTC22022303801E-FC01 Page 42 of 46 APPENDIXII--EXTERNALPHOTOGRAPH ReportNo.:PTC22022303801E-FC01 Page 43 of 46 ReportNo.:PTC22022303801E-FC01 Page 44 of 46 ReportNo.:PTC22022303801E-FC01 Page 45 of 46 ReportNo.:PTC22022303801E-FC01 Page 46 of 46 ******THEENDREPORT******

Test Setup Photos

RadiatedEmissions From30MHz-1000MHz TestfrequencyfromAbove1GHz FCC ID: 2A5UB100-700-B06

Contact Information

Applicant

William Zhang(manager)
[email protected]949 3669466Fax: 949 3669466

Technical Contact

Internatinal Precision Instrument CorpWilliam Zhang
[email protected]949 3669466

San clement, California · United States

Test Firm

Precise Testing & Certification Co., LTD.Chris Du
[email protected]+86-769-38808222

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.78 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.